Loading...
HomeMy WebLinkAboutR-4170051 7 4 3 1n REMOVE ROOF DRAIN LEADERS AND REDIRECT DOWNSPOUTS TO DRAIN OVERLAND ON SEVERED PROPERTY D REMOVE ASPHALT AND DISPOSE OF OFF -SITE SASE" EXCLUSIVE 'I EASEMENT FOR GRANTEE PURPOSE f:7 W EXISTING - BUILDING T REMAIN FOR INTERIM REMOVE ASPHALT AND DISPOSE OF OFF -SITE REMOVE GATE VALVE AND PIPE AS NECESSARY TO RECONNECT STORM LINE REMOVE OIL STOP VALVE FROM MANHOLE AND RECONFIGURE FOR STORMWATER FLOW -THROUGH ®8A REMOVE 3 ABOVE GRADE, SITE PROPERTY FENCE TO 2 BELOW GRADE OIL TANKSREMAIN UNTIL CONSTRUCTION OIL PUMP HOUSE. FOUNDATIONS. IS COMPLETE W — SPCC AND VAULT CAP AND DISPOSE OF OFF —SITE 1 `�— TO BE REMOVED 4'_0" N RETAINING WALL RETAINING ii !/ O U REMOVE p EXISTING FENCE II VA' PIPE TO BE REMOVED (TYP) II NA II EXISTING FOUNDATIONS ITEL \\ GAL TO BE REMOVED c = NEW OIL \� M 1 � \ II 1-F 14:; EXISTING CEXST OMM II� 11 III- VACANT 1 - - BUILDING BLDG EXISTING BUILDING TO REMAIN I I FOR INTERIM OIL TAN L 1_I I. _I IIL (TO REMAIN) (TO 11 300E GAL _ - I-L _1 II _ _I� REML IN NEW OIL NOT IN I_J L--, iII - - 11 SERVICE 11 --_- L � I I 10000 GAL NOT IN 1 '— A SERVICE, IN BELOW GRADE VAULT II _ ..I I 1 I --I I`.J I 3000 GAL N1011 IN II I 1--I I I I I SERVICE. IN BELOW 4 I .—I I;_ ;_ I;_I GRADE VAULIT—I I — I I I I 1 .—I 1 I 1 _I = II ESTIMATED FOOTPRINT OF _ _ _ _ _ _ UNDERGROUND VAULT - SAWCUT II _ _ _ I° "I I' 'I I'OR BREAK OFF TOP 12' OF'IWALL _ _ II I" 1 I" 1 I' _I II L -.I L -.I LAND BACKF ILL PER INOTES I2-4 11 L _:I L - - STATION SERVICE ON GRADING PLAN. REMOVE VAULT - II I TRANSFORMER TO BE WALL AS NECESSARY FOR NEW C RELOCATED BY PSE CATCH BASIN CB-47 II TREE STUMP AND ROOT BALL TO BE REMOVED TONREMAINCE ON TOP OF WALL 4'-0" RETAINING WALL EASEMENT REMOVE A�26 PIP EOF / Eh _— _— — --_ %% / L --1 L --1 L --1 L -'I 111 L --1 L --1 L EMOVE _ I I _ I I _ I I - I I I _ I _ I I I I B IIL--:I IIL---1 IIL_ II It - II __ I� - =I l�--- -- L-_:I I� __I L_ I __ L__:I ------------- -------------�'1 F0 / REMOVE EXISTING REMOVE AND CATCH BASIN AND STOCKPILE STORM LINE TO YARD ROCK / PROPERTY LINE AND PLUG WITH CONCRETE EXISTING FENCE / TO BE REMOVED (TYP) REMOVE I / --r---- PIPE I 55 ss UTILITY EASMENT #20010629002927 REMOVE EXISTING ECO-BLOCK WALL TO PROPERTY LINE. BACK UP GENERATOR / RETAIN ECO BLOCKS FOR NEW _ TO REMAIN '! I RETAINING WALL IF IN SERVICEABLE CONDITION W W >_ — w N a w - 0 15'-0" FIRE p MAIN EASEMENT rc #8407260401 ----------------------------------- 20 0 20 40 80 GRAPHIC SCALE IN FEET) / — W SAWCUT ASPHALT REMOVE ASPHALT CLEAN LINE AT AND DISPOSE OF PROPERTY LINE OFF —SITE F 15'-0" FIRE MAIN EASMENT $41407260401 I — — — — — PROPERTY LINE — — — — — EASEMENT LINE SCH 80 PVC PERFORATED PIPE RETAINING WALL O 13 CATCH BASIN 0 GATE VALVE _ EXISTING FOUNDATION TO REMAIN (� EXISTING FOUNDATION TO BE REMOVED EXISTING ASPHALT TO BE REMOVED -. WATER LINE g GAS LINE —ss SANITARY SEWER L POWER LINE Fo FIBER OPTIC LINE �Q 1 SANITARY SEWER MANHOLE NOTES 1. DEMOLITION SHALL NOT BEGIN UNTIL TESC MEASURES ARE INSTALLED PER TEMPORARY EROSION/SEDIMENTCONTROL PLAN. REFERENCE DRAWINGS D-20894 GRADING AND FENCING PLAN D-20895 DRAINAGE PLAN WO NUMBER: 141005363 REVISION DESCRIPTION: REVISED PER CITY PERMIT REVIEW COMMENTS ENGINEER REVIEWED APPROVED 3 2 i aIwill$]6y 4 0 lul KNOW what'sbelow Callbefore you dig. CITY OF RENTON R-417005 DEMOLITION PLAN SHUFFLETON SUBSTATION PUGET SUBSTATION DRAWING NO D -2 08 9 • SOUND ENGINEERING ENERGY DEPARTMENT sxEET:i OF 1 OGLE: 1":20,-0" CLASS: $ITE FILE '.ADD NO: D-20893_otdgn CODE SHU 1 C C D A 7 1 6 5 T 4