Loading...
HomeMy WebLinkAboutR-417006I 7 I 5 4 3 1 1 1 1n D I:7 m W 9'-91�1 = 5'-0" GRAVEL SHOULDER C 7' + RESERVED FOR 4'-0" RETAINING 21.40 (TYP AROUND SUBSTATION). LANDSACPE SCREENING WALL EASEMENT 22.10 SEE SHEET 2, DETAIL 1 2 21.40 W W 21.20 r \E -_ \ II -22J o r -/ L 22 / I II u• 22.85 N // ?r,\ `I// 21.40 2w �T, 11 _ _ OA O A I II ____P3.______��__-__-_ - _ -- _11 _____�� 21 .58 0 � 6'-0" 1 22.23 q -1 I111 22.00 1 22.17 \ LANDSCAPE II �c° 1 `J "I I-T "I `II' EXST \ SCREENING 11 S_ /� L I - - EXISTING gyp. i B / - - .. COMM VACANT 22.5711 ice/ 2 /b'D/ J -1 1'-1 I_J 1'-1 III---1�7 1 BUILDING BLDG / EXCLUSE II: i ♦ ♦ 22.62 EASEMENT 1y�� amea W: +� a ea a ea a / _'jl1 : FOR '1 M 1:: 1I .I GRANTEE 11 II -- ♦♦ i / ---..1 w ryryI-1-:I L---- \21.93 / PURPOSE IR� 23.00 ♦ / 1 TT 1 \ II II v3 �_--�---------__� `-Ir- , I 22. 68 II /� I_I II �I 1 .II. /R.2 ( II II II II II I_-1 II 1..1 1 8 I ._I ._I ._I 1 ._1 1 ._1 I: ::1 :_1 :_I 1 II 23.00 I'_I 15,151.07 SF -1 / I j n 22. 68 L__:I L__I L _:I II L__I L__:I L__:I II I 23- 22. 07 11 0 EXISTING I 1 \ CATCH BASIN (TYP). 11 7 BUILDING II 23. 00 1 1 \ II SEE SHEET 2, DETAIL 2 I FQ TO REMAIN FOR INTERIM I _a 0 0 22.68 II 23. OO I- I IJ 'I =-I I IL 00 I 11 w IL =II IL .:II IL_ II IL IL__II IL_ :II IL__II I / „01 III ^� J I II I II •• II II .. II II .. II II .. II III II II .. II II .. II II .. II I / --- --- --- III --- --- --- II / 0 a m I 11 "I "I F "I - "I I" ''I "I ___I _ ___I p:_ -::1 III___I _I f 0 aLL I k/ \ 11 I I___ L__:I I____I L__:I I_ _I L_ :I I___ -[--I L__I I____I L_ :I I____I L__I I____ �0 ^' ft 'ao 22.68 �y1 III 23.14 om / I 11 23. 00 II II II II II I'-''1 II I-:I-:1 II _ Ih 23.69 _ _ - - - - _ �II i - ♦ I - - - - - JI -1 l :_I I H- ♦ 23 / / It \ NEW 35' X 2' I I 1 / 22.49 RETAINING 1 WALL USING Q / 1 EXISTING 1 1 I ZR=25' 25' j�----� J 1.1 I ECO BLOCKS 111 1/ 1 m�- �\ // 1I' I 22.00 I 1/ �c y �1 RbS--{ I 1 0m__ __-_-__22.94 EXISTING I81\pBUILDING I1_ _ - _ - - _ zTO REMAIN /. STATION RELOCATED STATION r -�F[� FOR INTERIM1P 2 PLACES). SERVICE TRANSFORMER I I` �'y �0r+iI381 (REFERENCE ONLY) _ _ _I ` 0- i,w~-Q 23.86 m1 23.67 23.51 23.34 ' , �00,4If 23.72 -'24-- `I/ 23.27 23.91 23.92 ' - - -- mob' _`1�_�I�_ �k_-♦Ic-AIL -�I! -vJG- �- Ji -J!- J! - J/ 1J/� J/i� J/ 23.28 i 24.21 IW W - W C' ------------- W E I 24.15 23.90 23.86 \ // 15•_p•• 23. 68 23.10 o L - - 24.16 LANDSCAPE / 23.20 0 SCREENING 0 N 0 \ \ / 15'-0" FIRE MAIN EASEMENT ZAP #840T260401 a i / I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 0" / \ 29 EQUAL SECTIONS 20•_0.. 20, _0" \ ¢ 9'-91�2 = 284, _0„ 10'-0" 20 01� 4' -0"- 5' -0"- 20 0 20 40 so GRAPHIC SCALE (IN FEET) LEGEND F -_-_- PROPERTY LINE EASEMENT LINE - VV - - -21- - - EXISTING MINOR CONTOURS 42rfoo- n -25- - EXISTING MAJOR CONTOURS - -21- - - PROPOSED CONTOURS SUBSTATION FENCE EXISTING STORM DRAINAGE PIPE (REF ONLY) II • - - _ _ _ = PROPOSED STORM DRAINAGE PIPE (REF ONLY) 'l\ w WATER LINE (REF ONLY) w F o GAS LINE (REF ONLY) NEW 7' HIGH CHAIN TLINK STATION FENCE ss SANITARY SEWER (REF ONLY) (TYP). SEE D-18381 �\ E POWER LINE (REF ONLY) T TELEPHONE LINE (REF ONLY) 22.85 ro FIBER OPTIC LINE (REF ONLY) I 22.47 \ [� EXISTING RETAINING WALL 22.04 O PROPOSED RETAINING WALL 22.55 n CATCH BASIN (REF ONLY) LI 22 37 e• GATE VALVE (REF ONLY) I' 4'-0" RETAINING 23. 03 SPOT ELEVATION �j J'7 WALL EASEMENT EXISTING FOUNDATION (REF ONLY) l 22.65 GRAVEL DRIVEWAY 22.53 EAST -WEST BASELINE LANDSCAPE BUFFER 71'.22.50 S 46'43'23" w \ �_ I SANITARY SEWER MANHOLE (REF ONLY) GRADING NOTE: y.` \ 1. FOR AREAS OF THE SITE THAT DO NOT REQUIRE CUT IN EXCESS OF THE REQUIRED 9" OF BASE MATERIAL (AS PER \ DETAIL 1 ON SHEET 2): REMOVE EXISTING ASPHALT, GRADE TO BASE COURSE FINAL GRADE AND ADD YARD ROCK PER PSE STANDARD DETAIL. FOR AREAS REQUIRING FILL OR CUT IN EXCESS OF 9": 23.02 REMOVE EXISTING ASPHALT, GRADE TO SUB -BASE FINAL 23.00/ GRADE AND ADD 9" BASE COURSE AND YARD ROCK (AS / PER DETAIL 1 ON SHEET 2). 2. ALL FILL OR BACKFILL SHALL BE COMPACTED TO 95% OF \ MAXIMUM DENSITY IN ACCORDANCE WITH ASTM D1557 FOR COHESIVE FVE OASTMSD4254RTCOHEDSIONLESSI ACCCORDANCEOWITH FOR SOILS. / 3 / 3. REMOVE ALL DEBRIS FROM THE AREA TO BE BACKFILLED D / PRIOR TO BACKFILLING. / 2 4. PLACE LOAD BEARING BACKFILL IN LAYERS NOT MORE THAN 8" THICK, LOOSE MEASUREMENT. SPREAD AND COMPACT / EACH LAYER UNIFORMLY TO THE REQUIRED DENSITY. / ! 4 I' L1-01 ANDSCAPE SCREENING } UTILITY EASMENT iC #20010629002927 -15'-0" FIRE MAIN EASMENT #8407260401 THIS DRAWING SUPERSEDES D-5423_01 WO NUMBER: 141005363 REVISION DESCRIPTION: REVISED PER CITY PERMIT REVIEW COMMENTS ENGINEER APPROVED 3 REFERENCE DRAWINGS D-20891 SITE PLAN D-20892 TEMPORARY EROSION/SEDIMENT CONTROL PLAN D-20895 DRAINAGE PLAN D-20896 FOUNDATION PLAN D-20897 STRUCTURAL PLAN D-18381 CHAIN LINK FENCING SECTIONS AND DETAILS R-417006 a DEVELOPMENT ENGINEERING Know what's below. jchavez 07/26/2021 01 CBII before you dig. CITY OF RENTON R-417006 GRADING AND FENCING PLAN SHUFFLETON SUBSTATION PUGEDRAWING NO SOUND SUBSTATION • SOUND ENGINEERING D -2 08 9 4 ENERGY DEPARTMENT SHEET:1 OF 2 OGLE: 1":20f0" CLASS: SITE FILE '.ADD NO: D-20994_01.d9" CODE' SHU 1 C D 0 A i 7 I 5 4 2