Loading...
HomeMy WebLinkAboutR-4170168 I 7 I 6 I 5 I 4 I 3 I 2 I 1 HOM E I] rc w F1 N w SYMBOL MANUFACTURER/MODEUDESCRIPTION QTY ® ® ® HUNTER MP STRIP PROS-12-PRS40-CV 34 LIST RST SST SHRUB ROTATOR, 12" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE. LST=IVORY LEFT STRIP, SST=BROWN SIDE STRIP, RST=COPPER RIGHT STRIP, ON PRS40 BODY. 1j4„ ®0 00 HUNTER MP815 PROS-12-PRS40-CV 48 z• 4 SHRUB ROTATOR, 12" POP-UP WITH CHECK VALVE, tY4• y` PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE. 3 1 r M=MAROON AND GRAY ADJ ARC 90 TO 210, L=LIGHT BLUE Yz' 1a.3 I , AND GRAY 210 TO 270 ARC, O=OLIVE AND GRAY 360 ARC ON PRS40 BODY. SYMBOL MAN U FACTU RER/MODEUDESCRIPTION QTY RAIN BIRD FEB 3 1-1/2" PLASTIC INDUSTRIAL VALVES. LOW FLOW OPERATING CAPABILITY, GLOBE CONFIGURATION. 0 RAIN BIRD 44-LRC 1 1" BRASS QUICK -COUPLING VALVE, WITH STAINLESS STEEL SPRING, LOCKING THERMOPLASTIC RUBBER COVER, AND 2-PIECE BODY. Z SHUT OFF VALVE 3 BRASS BALL VALVE SIZED TO MATCH LINE MV RAIN BIRD EFB-CP 1-1/2" 1 1-1/2" BRASS MASTER VALVE, THAT IS CONTAMINATION PROOF W/SELF-FLUSHING FILTER SCREEN. GLOBE CONFIGURATION. z DRAIN VALVE 1 MANUAL GATE VALVE, BRASS, SIZED TO MATCH LINE APOLLO VALVES 3610701 1 PRESSURE LIMITED TO 70.64 PSI PRESSURE REDUCING VALVE, SINGLE UNION NPT CONNECTION, SIZE 1-1/211, 25-75 PSI PRESSURE RANGE, BRONZE ASTM B584 BODY CONTRACTOR TO PROVIDE 120 VAC POWER TO BF WATTS 007 1-1/2" 1 CONTROLLER AND VERIFY CONTROLLER LOCATION MAX. FLOW RATE IS 7.5 FT/S. © RAIN BIRD ESP12LXMEF 1 12 STATION COMMERCIAL CONTROLLER. PLASTIC WALL MOUNT. FLOW SENSING 2 1 IN,Yi Cl1 FS RAIN BIRD FS1 1Yz' zo.s 1 2 1yz, 2 3 2' D 1y+" z. 1-1/2" FLOW SENSOR FOR USE WITH RAIN BIRD MAXICOM, y. SITECONTROL, AND ESP-LXD CENTRAL CONTROL Y' SYSTEMS. BRASS MODEL. SUGGESTED OPERATING 4 ° 1Yd' 1Y°• RANGE OF 4.0 GPM TO 80.0 GPM. SENSORS SHOULD BE Yi I --- — FS Ya" . 1. 3S' 30'. Y' 1. �.. 1Yi BF Y'" Y' 1'4' -ye Yi 3/a- Y4" 21 WATER METER 1" 1 NEW 1.0" METER IRRIGATION LATERAL LINE: PVC SCHEDULE 40 1,029 L.F. OONStRUCTION NOTES Qi INSTALL SCHEDULE 40 MAINLINE PIPE PER DETAIL 6, SHEET 2. PIPE SIZE AS SHOWN ON PLAN. O2 INSTALL SCHEDULE 40 PVC LATERAL PER DETAIL 6, SHEET 2. PIPE SIZE AS SHOWN ON PLAN. O INSTALL IRRIGATION SLEEVE PER DETAIL 5, SHEET 2. O4 INSTALL BALL VALVE PER DETAIL 4, SHEET 2. O INSTALL QUICK COUPLING VALVE PER DETAIL 9, SHEET 2. O INSTALL AUTOMATIC CONTROL VALVE PER DETAIL 3, SHEET 2. 1. THE IRRIGATION PLAN IS DIAGRAMMATIC. INSTALL MAINLINE, VALVES, PIPE, AND ASSOCIATED EQUIPMENT IN PLANTER BEDS AND WITHIN PROPERTY. 2. ENSURE IRRIGATION HEADS ARE ADJUSTED SO AS NOT TO DIRECT TOWARD BUILDINGS OR SPRAY ONTO THE BUILDINGS. 3. ENSURE IRRIGATION HEADS ARE ADJUSTED SO AS NOT TO CREATE SPRAY SHADOWS ON ADJACENT TREES AND SHRUBS. 20 0 20 40 860 0 NORTH GRAPHIC SCALE (IN FEET) GENERAL NOTES: 1. SEE IRRIGATION NOTES, SHEET 2. 2. SEE IRRIGATION DETAILS, SHEET 2. 3. SEE LANDSCAPE PLAN, SHEETS 1-3. CURRENT PLANNING O Clark Close 07/21/2021 POC IS NEW 1" METER TO BE CONNECTED AND INSTALLED BY CITY AND PAID BY OWNER DAVID EVANS ANDASSOCIATESINc. IN 14432 SE Eastgate Way, Suite 400 Bellevue Washington 98007 Phone: 425.519.6500 IRRIGATION MAINLINE: PVC SCHEDULE 40 547.4 L.F. PIPE SLEEVE: PVC SCHEDULE 40 Valve Callout J__ Valve Number Valve Flow Valve Size WO NUMBER: 141005363 REVISION DESCRIPTION: ORIGINAL USE CADD 1 GREGORY KING ENGINEER JON GAGE REVIEWED 22.3 L.F. * CONTRACTOR TO VERIFY QUANTITIES R-417016 4 Know what's below. Call before you dig. IRRIGATION PLAN SHUFFLETON SUBSTATION �n PSI- , o . 1"=20'-0" NO: D-20899 01.M SUBSTATION ENGINEERING DEPARTMENT CLASS: SITE SHU