Loading...
HomeMy WebLinkAboutS-418805O 73 N N 0 N (O CD N / Q0 N / 0 0 CD M I. N 0 5' 10' 20' SCALE: 1 "=10' i-i-j_i71 SITE MAP KEY PLAN ASBUILT SEWER PLAN AND PROFILE - ACCESS ROAD OF EDENFIELD (SUMPTER) SHORT PLAT A PORTION OF SECTION 14, TOWNSHIP 23 N., RANGE 05 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON • I � 1 12" STORM \ � • � .................� ; MINIMUM ROOT •................................... v:............................I............................, 3 ��\ I� \. ..... Iy..................PROTECTION ZONE 378.90 O\ EX TREES TO BE I "' 11 10' UE ado TREE PROTECTION FENCE AND SAVED TYP EASEMENT INSTALLED PER TREE RETENTION PLAN ON SHEETS 37 TO 39 �\ 68 LF 8" SS BOLLAR S SHALL BE PER....................................................................................... I Q. U3 �� COR STD. PLAN H022 w a i (FIXED) I .......1. 8" WATER J \ 0 o a :.., ...:.... • '..:. BOLLARDS SHALL BE PER.. a COR STD. PLAN H021 88MH#64 (REMOVABLE) 129 •. _ : } :.. �•3e SS ��6 .. 0 ,- 1 SSMF1#7 . g BOLLARDS SHALL BE PER PLAT BOUNDARY o 0000 ..............376....... . COR STD. PLAN H022 > o w — — — — °,° (FIXED) Q� Ww N N 37 °°° w ogog ,° / 3�8...........................................................:� cn I CO Lg U EX FIRE HYDRANT a ASSEMBLY I " WATER I I I 375 370 .e >02 0 _Q w 0 SECTION LINE Ulm a is �� R TYPE 1-4 " = " 0 SECTION LINE 00 p N I� � N M m (gyp r co 00 ^ 00 00 cd 0)rn of 06 06 1 RECORD DRAWINGS AS BUILT TJS 0/10/2 BJT S"l DESIGN RK BENCHMARK DRAWN: RK DATUM DOMEDIN CONCRETE MONUMENT IN BRASS DOMESS FOUND�INARK 4X41 0.4 Cll HORIZONTAL DATUM: VERTICAL DATUM: CASE 0.5" BELOW GRADE OBSERVED BELOW GRADE OBSERVED 37555 BJT NAD '83/'91 NAVD '88 N: 175866.55, E: 1319201.78 N: 175852.22, E: 1319809.82 N0. REVISION BY DATE APPR APPROVED: JT 380 375 370 360 HORIZONTAL 0 10' 20' 40' SCALE: 1 "=20' VERTICAL 0 2.5' 5' 10, SCALE: 1 "=5' SEWER NOTES: 1. SEWER PIPE SHALL BE 8" PVC SDR-35 UNLESS NOTED OTHERWISE. 2. SIDE SEWERS ARE PRIVATE AND SHALL BE 6" PVC SDR-35 ® 2.0% OR GREATER SLOPE. 3. SIDE SEWERS SHALL BE INSTALLED PER COR STD. PLAN 406.1. 4. SIDE SEWERS SHALL BE CONSTRUCTED OF THE SAME MATERIAL AS THE SEWER MAIN 5. ALL MANHOLES SHALL BE PER COR STD. PLAN 400.1 6. ALL MANHOLE FRAME AND COVER SHALL BE PER COR STD. PLAN 401.1 7. HORIZONTAL SEPARATION BETWEEN SEWER AND WATER SHALL BE A MINIMUM OF 10' AND 7' FOR STORM. scALE PLAN: 1 "=10' VERTICAL: NAw 19r18 PROF: H 1 "=20' HORIZONTAL: NAD 1983/1991 V1 "=5' ONE INCH DATU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CALL BEFORE YOU DIG: 1-800-424-5555 . k CITY OF RENTON Planning/Building/Public Works Dept. F. TAL� 0 Z 1423 ��F F S T NA L 0/10/20 J E C v O 5 m C � C LJ.I c � N M a0�1N �a CN 0) 75 L\ Ll i C O 1-0 4-7 f V Ln /c�v W U r a) Y �,t S-418805 IN COMPLIANCE WITH CITY OF RENTON STANDARDS ASBUILT SEWER PLAN AND PROFILE - ACCESS ROAD EDENFIELD (SUMPTER) SHORT PLAT MAINVUE WA LLC 1110112TH AVE NE, SUITE 202 BELLEVUE, WA 98004 M I` r— O CD 0 6) ccc O J !Z ~ N 0) O T N �O z 10/10/2022 LL-i m 0 FIELDBOOK: PAGE: DRAWING NO, �w cn w 011 `loll M