ASBUILT SEWER DETAILS
OF
EDENFIELD �SUMPTER) SHORT PLAT
A PORTION OF SECTION 14, TOWNSHIP 23 N., RANGE 05 E., W.M.
CITY OF RENTON, KING COUNTY, WASHINGTON
MANHOLE FRAME AND COVER
SEE STD PLAN 401
ADJUSTMENT RINGS AND MORTAR JOINTS
SEE NOTE 3
FIRS( STEP SHALL BE A MAXIMUM OF 18"
BELOW THE COVER
CONE (ECCENTRIC)
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
RUBBER GASKETED JOINTS SEE NOTE 5
IF REQUIRED, LADDER -POLYPROPYLENE
SHALL BE ATTACHED TO MANHOLE
MAX PIPE SIZE - 'E'
SHELF AND CHANNEL SHALL BE
3000 PS1 CONCRETE
PRECAST BASE SECTION
OR CAST IN SHELF
COMPACTED SUBGRADE WITH 6"
CRUSHED ROCK OR ADDITIONAL
NOT TO SCALE
MA-ERIAL SUITABLE TO
SUPPORT STRUCTURE
A'
'8'
'C' I
'D'
'E'
48" MH
48"
6" MIN.
5"MIN
24" MIN.
21" ID
54" MH
54
1
8" MIN
5 b" MIN
24" MIN
24" 1 D
60" MH
60"
8" MIN
6" MIN
42" MIN
30" 1 D
NOTES,
1 STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED
2 MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE IN CONFORMANCE WITH ASTM C-478.
3 ADJUSTMENT OF THE CASTING TO GRADE SHALL BE PER STD PLAN 106 THE USE OF SHIMS IS PRO-11 ITED.
SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
FACTORY-COA-ED (SEALED) WITH A HIGH SOLIDS URETHANE COATING, WASSER MC-SHIELDCOAT '00 OR
APPROVED EQUAL. CO -OR OF COATING SHALL BE WHITE
5 RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443
6 CHANNEL WIDTH AND -IECHT SHALL EQUAL THE INSIDE DIAMETER OF THE LARGEST PIPE
7 CONNECTIONS TO MANHOLE SHALL BE MADE USING KOR-N-SEAL BOOTS OR APPROVED EQUAL
8 IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12"
ABOVE FINISHED GRADE OR MUST HAVE AN AT -GRADE, MINIMUM 2'-WIDE CONCRETE WNG POURED ARDJNi7
THE COVER IN PAVED AREAS, COVER MUST SLOPE TO MATCH PAVING.
9 MANHOLES OVER 20' DEEP SHALL BE A MIN MUM OF 60" IN DIAMETER
STD. PLAN - 400.1
•n PUBLIC WORKS -sppIl d v
'!C DEPARTMENT STANDARD SANITARY MANHOLE 26/202
Martin Pastuci��
PkNOTTE
T
ACOVER PER STD PLAN 401
SEAL WITH AR 4000 OR APPROVED
EQUAL AND DRY SAND AFTER PLAN
PATCHING
TUTS
OUTSIDE DIAMETER OF
(SEE NOTE 9) ADJUSTMENT RNG AND Y SEE NOTE 2
X I BOTTOM OF FRAME
MORTAR JOINT(S) (3/8" MIN -2" MAX) ADJUSTMENT RING (1" MIN.) SEE
SEE NOTE 3 AND SPECIAL PROVISION NOTE 6.
SECTION A -A
NOT-
1 REMOVE PAVEMENT AND BASE MATERIALS FORA DISTANCE 5- CONSTRUCTION AND ADJUSTMENT" SHALL BE PERFORMED
WHICH IS EQUAL TO THE DIAMETER OF THE FRAME PLUS ONE ONLY BY A JOURNEYMAN MASON.
FOOT (MIN ) ADJUST CASTING FRAME TO PAVEMENT
SURFACE USING RISER RINGS AND MORTAR. 6. ADJUSTMENT OF THE FRAME TO GRADE SHALL BE
ACCOMPLISHED WITH ADJUSTMENT RINGS AND MORTAR ONLY
2. REPLACE EXCAVATED MATERIAL WITH A MINIMUM Or a, or THE USE OF SHIMS IS PROHBRED.
HMA CLASS j PG 64.22 (OR TO A DEPTH THAT IS Y BELOW
THE BOTTOM OF THE UPPER ADJUSTMENT RING WHICHEVER 7. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
IS GREATER) OR AS APPROVED BY THE ENGINEER. TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH
3. ADJUSTMENT RINGS AND FRAME SHALL BE FULLY BEDDED IN
MORTAR. MORTAR SHALL BE ASTM C270 FOR TYPE S 8. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN
VISIBLE UPON COMPLETION.
4 MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURERS DIRECTIONS. 9 X= 1'4r MIN. TO 2'-6' MAX_ - PER ENGINEER'S INSTRUCTION
STD. PLAN - 106
• PUBLIC WORKS TYPICAL CONSTRUCTION G ,sovio
DEPARTNIENT AND ADJUSTMENT OF
MANHOLE RISERS
Utility Specifications
Sanitary Sewer Notes and Specifications
THESE NOTES SHALL APPEAR ON PROJECTS FOR THE WASTEWATER UTILITY.
1. All work and work material shall be in conformance with the standards and specifications
of the City of Renton Planning/Building/Public Works Department and the latest edition
of the WSDOT/APWA Standards and Specifications, as approved and modified by the
City of Renton in the Renton Standard Plans & Specifications. A set of approved plans
I
shall be kept on site at all times during construction.
I
2. The hours of work in the street right of way shall be per City specifications on weekdays
I
unless otherwise approved in writing by the Planning/Building/Public Works Department.
An approved traffic control plan must be obtained prior to beginning any work within
i
public right of way.
x
3. All locations of existing utilities shown are approximate and it shall be the contractor's
DO
responsibility to verify the true and correct location so as to avoid damage or
Y
disturbance.
Q
=D
4. A pre -construction conference and a 24 hour notice shall be required prior to starting
new construction. It shall be the contractor's responsibility to secure all necessary
permits prior to starting construction. (Inspection will be accomplished by a
representative of the City of Renton.) It shall be the contractor's responsibility to notify
ai
the Public Works inspector 24 hours in advance of backfilling all construction.
0
U
(n
5. Contractor is solely responsible for the means, methods and sequences of construction
and for the safety of workers and others on the construction site.
mi
a-
6. It shall be the responsibility of the contractor to obtain street use and any other related
rn
permits prior to any construction.
N
N
7. Plans approved by the City of Renton, Public Works Department shall take precedence
0
over all other plans.
N
8. A copy of these approved plans must be on the job site whenever construction is in
N
progress.
rn
E
E
9. The contractor shall provide the City of Renton with an as -built drawing of the sanitary
sewer system, which has been stamped and signed by a licensed professional engineer
a,
or licensed professional surveyor.
0
10. Backfill shall be placed equally on both sides of the pipe in layers with a loose average
6
depth of 6 inches, maximum depth of 8 inches, thoroughly tamping each layer to 95
percent of maximum density. These compacted layers must extend for one pipe
LO
diameter on each side of the pipe or to the side of the trench. Materials to complete the
fill over pipe shall be the same as described.
a)
a)
U)
11. Open cut road crossings for utility trenches on existing traveled roadway shall be
backfilled with crushed rock and mechanically compacted unless otherwise approved by
N
a)
1 RECORD DRAWINGS AS BUILT
N
BENCHMARK
CD
CD
CD
SS
DATUM
FOUND "
N
DOMEDIN CONCRETE MONUM NT IN
BRASS DOME�INARK 4X41 0.4
HORIZONTAL DATUM: VERTICAL DATUM: CASE 0.5" BELOW GRADE OBSERVED
BELOW GRADE OBSERVED 37555
NAD '83/'91 NAVD '88 N: 175866.55, E: 1319201.78
N: 175852.22, E: 1319809.82 N0. REVISION
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
WASTEWATER_ UTILITY STANDARD NOTES
1 ALL WORK AND MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY
OF RENTON PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOTlAPWA STANDARDS AND
SPECIFICATIONS. AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS & SPECIFICATIONS
A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION
2 DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 HORIZONTAL CONTROL
SHALL BE NORTH AMERICAN DATUM 1983/1991 UNLESS OTHERWISE APPROVED BY THE CITY BENCHMARKS
AND MONUMENTS SHALL BE REFERENCED ON THE APPROVED PLANS
3 A PRE -CONSTRUCTION CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW
CONSTRUCTION IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS,
INCLUDING STREET USE PERMITS, PRIOR TO STARTING CONSTRUCTION INSPECTION WILL BE ACCOMPLISHED
BY A REPRESENTATIVE OF THE CITY IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC
WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION
4 THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS
UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC
CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY
5 CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS. METHODS AND SEQUENCES OF CONSTRUCTION AND
FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL,
STATE AND FEDERAL REQUIREMENTS
6. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE
THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF RCW 19 122 A DIG TICKET SHALL BE
OBTAINED A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION THE CONTRACTOR
SHALL HAVE A COPY OF THE DIG TICKET ON SITE AT ALL TIMES
7. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH
OF 12-INCHES, MAXIMUM DEPTH 18-INCHES, THOROUGHLY COMPACTING EACH LAYER TO 95 PERCENT OF
MAXIMUM DENSITY THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE
PIPE OR TO THE SIDE OF THE TRENCH MATERIALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE
EQUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19)
8 SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER-GASKETED ASTM D 3034. SCR 35.
C900/C905 OR DUCTILE IRON CLASS 50. UNLESS OTHERWISE APPROVED BY THE CITY
9 SANITARY SEWER PIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC)
UNLESS APPROVED BY THE CITY IF A SANITARY SEWER IS TO BE LOCATED UNDER ANY STRUCTURE (WALL,
BUILDING FOUNDATION. ETC ), IT SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE
OF WASHINGTON IN ACCORDANCE WITH STANDARD DETAIL 412
10 OPEN -CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAYS SHALL BE
BACKFILLED WITH CRUSHED SURFACING AGGREGATE (WSDOT SPECIFICATION 9-03 9(3) AND MECHANICALLY
COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY
11 ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH
THE STANDARDS AND SPECIFICATION OF THE CITY AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS
AND SPECIFICATION AS APPROVED AND MODIFIED BY THE CITY IN THE RENTON STANDARD PLANS &
SPECIFICATIONS THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE
FOUNDATION MATERIAL TO A UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED
ON A UNIFORMLY DENSE, UNYIELDING BASE PIPE BEDDING SHALL BE IN ACCORDANCE WITH STANDARD PLAN
405
12 ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF
THE CITY FOR THE PREVENTION OF ON -SITE EROSION BOTH DURING CONSTRUCTION AND AFTER THE
COMPLETION OF CONSTRUCTION IN ACCORDANCE WITH THE CURRENT SURFACE WATER DESIGN MANUAL
13 THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH A RECORD DRAWING OF THE SANITARY SEWER
SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED
PROFESSIONAL SURVEYOR
. PUBLIC WORKS
DEPARTMENT
STQ. PLAN - 413
WASTEWATER UTILITY °"'"�& r- -
Martin Pastuchao/26/2
STANDARD NOTES _
Wt
���
F TA`y
C.;-
Utility Specifications
1423
/STE���
NA L
o/so/zoz
12. Datum for Vertical Control shall be North American Vertical Datum 1988 Meters, and for
Horizontal Control shall be North American Datum 1983/1991 Meters unless otherwise
approved by the City of Renton Public Works Department. Reference benchmark and V IE
elevations are noted on the plans. V
13. All disturbed areas shall be seeded and mulched or otherwise stabilized to the
satisfaction of the Department for the prevention of on -site erosion after the completion L
of construction.
a)m--+
14, All pipe and appurtenances shall be laid on a properly prepared foundation in : i
accordance with the standards and specifications of the City of Renton O
Planning/Building/Public Works Department and the latest edition of the WSDOT/APWA m
Standards and Specifications, as approved and modified by the City of Renton in the N .0
Renton Standard Plans & Specifications. This shall include necessary leveling of the W Z3
trench bottom or the top of the foundation material, as well as placement and O M
compaction of required bedding material, to uniform grade so that the entire length of
the pipe will be supported on a uniformly dense, unyielding base. Pipe bedding shall be iii Q op N
pea gravel 6 inches above and below the pipe. dl (N
c Q IN
1.0
15, Sanitary sewer pipe shall be polyvinyl chloride (PVC) rubber gasketed ASTM D 3034, N � r
SDR 35, or ductile iron class 50, unless otherwise approved by the Wastewater Utility. 0) Lr7
I. � a-' N
16, In unimproved areas, manhole to extend minimum 6 inches and maximum 12 inches M 0 N C: Lo
above finished grade or must have minimum 2' diameter concrete ring poured at grade. m V QO ) �
In paved area, cover must slope in all directions to match paving. r
TJS
10/10/22
BJT
suwEYED:
SCALE:
N/A
DESIGNED.
K
DRAWN:
RK
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
CHECKED.BJT
BY
DATE
I APPR
�� BJT
VERTICAL NAw 1980
HORRONrAL' NAD 1983 1991
DATU M
CALL BEFORE YOU DIG:
1-800-424-5555
CITY OF
RENTON
Planning/Building/Public Works Dept.
S-418806
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
ASBUILT SEWER DETAILS
EDENFIELD (SUMPTER) SHORT PLAT
MAINVUE WA LLC
1110112TH AVE NE, SUITE 202
BELLEVUE, WA 98004
M
I,
Q
J
~
N
0)
O
T
N
�O
z
10/10/2022
LL_J
m
0
FIELDBOOII
PAGE
DRAWING NO:
Ill
�
cn
SFIEET: 35 OF: 47