ILLUMINATION GENERAL NOTES
1. THE LOCATION OF ALL CONDUIT, JUNCTION BOXES, AND CABINETS SHOWN ON THIS PLAN ARE APPROXIMATE ONLY. FINAL LOCATION SHALL BE
DETERMINED BY THE CONTRACTOR AND CONFIRMED IN THE FIELD BY THE ENGINEER.
2. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, CITY OF RENTON STANDARDS AND WSDOT STANDARDS AND SPECIFICATIONS, CURRENT
EDITION.
3. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY.
4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE.
5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48
HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY
COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE.
7. POLE FOUNDATIONS SHALL NOT BE EXCAVATED AND POURED BEFORE POLE LOCATIONS ARE APPROVED BY THE ENGINEER.
8. ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS, BASE BOLTS, AND CABINET
FOUNDATION.
9. CONTRACTOR TO CONTACT CITY ELECTRICAL INSPECTOR FOR UNDERGROUND/ROUGH-IN INSPECTION.
10. CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL 425-430-7423, FOR STREET LIGHTING COMPLIANCE TO
STANDARDS INSPECTION PRIOR TO ENERGIZING.
11. FOLLOWING THE TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR SERVICE
INSPECTION.
12. FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR, ELECTRICAL CONTRACTOR SHALL SUBMIT APPLICATION TO PSE TO ENERGIZE
THE STREET LIGHTING.
13. ELECTRICAL CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL INSPECTION AFTER STREET LIGHTING HAS BEEN ENERGIZED.
14. CONTRACTOR SHALL POTHOLE ALL POLE LOCATIONS TO CONFIRM THAT THERE ARE NO UNDERGROUND CONFLICTS. IF A CONFLICT IS DISCOVERED, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION.
15. THE CONTRACTOR SHALL CONFIRM THAT THE APPROPRIATE MINIMUM CIRCUMFERENTIAL CLEARANCE IS PROVIDED BETWEEN LUMINAIRE POLES AND
OVERHEAD POWER LINES. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION.
ASBUILT ILLUMINATION PLAN
OF
SUMPTER SHORT PLAT
A PORTION OF SECTION 14, TOWNSHIP 23 N., RANGE 05 E., W.M.
CITY OF RENTON, KING COUNTY, WASHINGTON
ILLUMINATION WIRING DIAGRAM
EX E POWERED BY EX SERVICE N
AT THE NE CORNER OF
NE 6TH ST & 156TH AVE SE cL
O
Q
EX E 3 1
EX SERVICE
P� AT 158TH & 142ND
E�X AZNO EX ILLUM A
S ILLUM B
EX N N 2
6 3
Q
NOT TO SCALE 4 N
5 5 00
Q
ILLUMINATION POLE SCHEDULE
LUM.
POLE ID
*OFFSET
*
**
**
MOUNT.
ARM
WATTAGE
INITIAL
LUMINAIRE TYPE -
POLE NO.
NUMBER***
STREET
STATION
LATITUDE
LONGITUDE
HEIGHT
LENGTH
VOLTAGESERVICE/
CIRCUIT
ITYPE
LUMENS
DISTRIBUTION
BASE
COMMENT
O
WAPATO PL SE
1 1 +94.0
17.5' RT
N47.4756423
W122.1300143
14'
---
240
NEW
34W LED
3,060
CYCLONE PRESTIGE
FIXED
NEW FOUNDATION AND POLE PER RENTON
CY1 7T4-VS3AR-SKY-3-34W-4K-240-EA 1
STD PLAN 116.1.
0WAPATO
PL SE
11+42.5
17.5' LT
N47.4754705
W122.1300251
14'
---
240
NEW
34W LED
3,060
CYCLONE PRESTIGE
FIXED
NEW FOUNDATION AND POLE PER RENTON
CY1 7T4-VS3AR-SKY-3-34W-4K-240-EA 1
STD PLAN 116.1.
0WAPATO
PL SE
1 1 +01.5
19.0' RT
N47.4754234
W122.1298157
14'
---
240
NEW
34W LED
3,060
CYCLONE PRESTIGE
FIXED
NEW FOUNDATION AND POLE PER RENTON
CY1 7T4-VS3AR-SKY-3-34W-4K-240-EA 1
STD PLAN 116.1.
0WAPATO
PL SE
10+ 14.5
17.0' LT
N47.4751980
W 122.1298401
14'
---
240
NEW
34W LED
3,060
CYCLONE PRESTIGE
FIXED
NEW FOUNDATION AND POLE PER RENTON
CY1 7T4-VS3AR-SKY-3-34W-4K-240-EA 1
STD PLAN 116.1.
35'
6'
8OW LED
9,466
CYCLONE DOMIA
O5
156TH AVE SE
30+35.0
27.0' RT
N47.4752482
W 122.1321300
240
NEW
CY55P1B-FGC-3-80W-4K-240
FIXED
NEW FOUNDATION AND POLE PER RENTON
16.5'
4'
F40W LED
4,733
CYCLONE DOMIA
STD PLAN 1 17.1.
CYM55P 1 -FGC-3-40W-4K-240
0156TH
AVE SE
30+93.5
54.5' RT
N47.4754124
W 122.1320203
16.5
4'
240
NEW
40W LED
4,733
CYCLONE DOMIA
FIXED
NEW FOUNDATION AND POLE PER RENTON
CYM55P 1-FGC-3-40W-4K-240
STD PLAN 117.2.
* STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIOR TO IMPLEMENTING.
** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS.
*** POLE ID NUMBERS SHALL BE PROVIDE BY ERIC CUTSHALL (CITY OF RENTON) FOR INCORPORATION INTO AS -BUILT PLANS AND INSTALLED BY THE
CONTRACTOR IN ACCORDANCE WITH COR STD. PLAN 121.
BENCHMARK
FOUND PUNCHMARK IN 1%4" BRASS FOUND PUNCHMARK IN 1%4" BRASS
DATUM DOME IN CONCRETE MONUMENT IN DOME IN 4X4
CASE 0.5' BELOW GRADE OBSERVED 0.4' BELOW GRADE 37555
HORIZONTAL DATUM: VERTICAL DATUM: (NAD 83/1 1) (NAD 83/1 1)
NAD '83/'91 NAVD '88 N:175866.55, E:1319201.78 N:175852.22, E:1319809.82 FN 0. REVISION BY DATE APPR
CONSTRUCTION RECORD
DRAWING
THIS CONSTRUCTION RECORD DRAWING IS A COPY
OF THE APPROVED CONSTRUCTION DRAWINGS
PREPARED BY BARGHAUSEN CONSULTING
ENGINEERS, INC AND HAS BEEN EDITED TO
REFLECT ASBUILT CONDITIONS. THE INFORMATION
PROVIDED ON THESE RECORD DRAWINGS IS A
COMBINATION OF FIELD SURVEYED INFORMATION
AND DOCUMENTED FIELD REVISIONS.
SURVEYED: I SCALE:
DESIGNED:
GRL/TDR
DRAWN:
GIRL
ONE INCH
CHECKED:
TDR
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
APPROVED:
CTB
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 1 16. 1. FURNISH AND INSTALL
NEW NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER
ILLUMINATION POLE SCHEDULE, SHEET IL-03 & IL-04, AND PER CITY OF RENTON STD PLANS
116.1, 116.2, 119, 120 & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE
ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD DETAIL 121.
D
CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 1 17. 1. FURNISH AND INSTALL
NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER
ILLUMINATION POLE SCHEDULE, SHEET IL-03 & IL-04, AND PER CITY OF RENTON STD PLANS
117.1, 117.3, 119, 120 & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE
ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD DETAIL 121.
O3 EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN.
40 EXISTING ARTERIAL STREET DECORATIVE LUMINAIRE POLE TO REMAIN.
50 EXISTING NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE POLE TO REMAIN.
6)THROUGH
EXTEND NEW CONDUIT AND CONDUCTORS TO EXISTING JUNCTION BOX. ROUTE NEW CONDUCTORS
EXISTING CONDUIT AND EXISTING JUNCTION BOX TO EXISTING SERVICE CABINET. CONNECT
NEW CONDUCTORS TO SPARE CONTACTOR IN EXISTING SERVICE CABINET. IF SPARE CONTACTOR
DOES NOT EXIST, FURNISH AND INSTALL NEW CONTACTOR AND CONNECT NEW CONDUCTORS TO
NEW CONTACTOR.
OEXISTING SERVICE CABINET TO REMAIN. CONTRACTOR SHALL FURNISH AND INSTALL NEW
CONTACTOR AND CONNECT NEW ILLUMINATION CONDUCTORS TO IT.
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 117.2. FURNISH AND INSTALL
NEW ARTERIAL STREET DECORATIVE PEDESTRAIN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX
PER ILLUMINATION POLE SCHEDULE, SHEET IL-03 & IL-04 AND PER CITY OF RENTON STD PLANS
117.2, 117.3, 119, 120 & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE
ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD DETAIL 121.
9)THROUGH
EXTEND NEW CONDUIT AND CONDUCTORS TO EXISTING JUNCTION BOX. ROUTE NEW CONDUCTORS
EXISTING CONDUIT AND EXISTING JUNCTION BOXES TO EXISTING SERVICE CABINET AT THE
CORNER OF NE 6TH ST & 156TH AVE SE. CONNECT NEW CONDUCTORS TO SPARE CONTACTOR IN
EXISTING SERVICE CABINET. IF SPARE CONTACTOR DOES NOT EXIST, FURNISH AND INSTALL NEW
CONTACTOR AND CONNECT NEW CONDUCTORS TO NEW CONTACTOR.
CALL BEFORE YOU DIG:
1-800-424-5555
CITY OR + R
RENTON
Planning/Building/Public Works Dept.
70--79 2027
4- O 0.
00
C) 00
DN
D_N Lu
o`q-
4- 06 N a-
�
0 u O
z QO N M
p co
o CD
L 00 1
()NO
Q j Lr)
3 O CN
LD)m ~ CV
LuC�>U
Lu Q
O
- �C4 U
U
0 Ln
�
C9% V) Q fn O
L
n
O 00
Q
w
�o
o
T-418803
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
ASBUILT ILLUMINATION PLAN
SUMPTER SHORT PLAT
KIM GREER
5007 E CORAL LANE
SPOKANE, WA 99223
T
O
06
T
AN
H
H
H
H
H
H
J
O�
N
=
w 0
DATE:
Z
10/19/2021
w m
O
FIELDBOOK:
PAGE:
C
G�
DRAWING NO:
1 L-02
�ui
� v
m
SHEET: w w OF: 47
(�(F