HomeMy WebLinkAboutT-418803ILLUMINATION CONSTRUCTION NOTES 00 T T O rr I- 11 c/) rr Lu ��, 0 N N O N 0 N E a 3 Z3 U) Q E D 73 m U) Q N N 0 N rn a 0 i rn 0 N O N N 0 N a a_ 0 V) ILLUMINATION GENERAL NOTES 1. THE LOCATION OF ALL CONDUIT, JUNCTION BOXES, AND CABINETS SHOWN ON THIS PLAN ARE APPROXIMATE ONLY. FINAL LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND CONFIRMED IN THE FIELD BY THE ENGINEER. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, CITY OF RENTON STANDARDS AND WSDOT STANDARDS AND SPECIFICATIONS, CURRENT EDITION. 3. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. 7. POLE FOUNDATIONS SHALL NOT BE EXCAVATED AND POURED BEFORE POLE LOCATIONS ARE APPROVED BY THE ENGINEER. 8. ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS, BASE BOLTS, AND CABINET FOUNDATION. 9. CONTRACTOR TO CONTACT CITY ELECTRICAL INSPECTOR FOR UNDERGROUND/ROUGH-IN INSPECTION. 10. CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL 425-430-7423, FOR STREET LIGHTING COMPLIANCE TO STANDARDS INSPECTION PRIOR TO ENERGIZING. 11. FOLLOWING THE TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR SERVICE INSPECTION. 12. FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR, ELECTRICAL CONTRACTOR SHALL SUBMIT APPLICATION TO PSE TO ENERGIZE THE STREET LIGHTING. 13. ELECTRICAL CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL INSPECTION AFTER STREET LIGHTING HAS BEEN ENERGIZED. 14. CONTRACTOR SHALL POTHOLE ALL POLE LOCATIONS TO CONFIRM THAT THERE ARE NO UNDERGROUND CONFLICTS. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION. 15. THE CONTRACTOR SHALL CONFIRM THAT THE APPROPRIATE MINIMUM CIRCUMFERENTIAL CLEARANCE IS PROVIDED BETWEEN LUMINAIRE POLES AND OVERHEAD POWER LINES. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION. ASBUILT ILLUMINATION PLAN OF SUMPTER SHORT PLAT A PORTION OF SECTION 14, TOWNSHIP 23 N., RANGE 05 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON ILLUMINATION WIRING DIAGRAM EX E POWERED BY EX SERVICE N AT THE NE CORNER OF NE 6TH ST & 156TH AVE SE cL O Q EX E 3 1 EX SERVICE P� AT 158TH & 142ND E�X AZNO EX ILLUM A S ILLUM B EX N N 2 6 3 Q NOT TO SCALE 4 N 5 5 00 Q ILLUMINATION POLE SCHEDULE LUM. POLE ID *OFFSET * ** ** MOUNT. ARM WATTAGE INITIAL LUMINAIRE TYPE - POLE NO. NUMBER*** STREET STATION LATITUDE LONGITUDE HEIGHT LENGTH VOLTAGESERVICE/ CIRCUIT ITYPE LUMENS DISTRIBUTION BASE COMMENT O WAPATO PL SE 1 1 +94.0 17.5' RT N47.4756423 W122.1300143 14' --- 240 NEW 34W LED 3,060 CYCLONE PRESTIGE FIXED NEW FOUNDATION AND POLE PER RENTON CY1 7T4-VS3AR-SKY-3-34W-4K-240-EA 1 STD PLAN 116.1. 0WAPATO PL SE 11+42.5 17.5' LT N47.4754705 W122.1300251 14' --- 240 NEW 34W LED 3,060 CYCLONE PRESTIGE FIXED NEW FOUNDATION AND POLE PER RENTON CY1 7T4-VS3AR-SKY-3-34W-4K-240-EA 1 STD PLAN 116.1. 0WAPATO PL SE 1 1 +01.5 19.0' RT N47.4754234 W122.1298157 14' --- 240 NEW 34W LED 3,060 CYCLONE PRESTIGE FIXED NEW FOUNDATION AND POLE PER RENTON CY1 7T4-VS3AR-SKY-3-34W-4K-240-EA 1 STD PLAN 116.1. 0WAPATO PL SE 10+ 14.5 17.0' LT N47.4751980 W 122.1298401 14' --- 240 NEW 34W LED 3,060 CYCLONE PRESTIGE FIXED NEW FOUNDATION AND POLE PER RENTON CY1 7T4-VS3AR-SKY-3-34W-4K-240-EA 1 STD PLAN 116.1. 35' 6' 8OW LED 9,466 CYCLONE DOMIA O5 156TH AVE SE 30+35.0 27.0' RT N47.4752482 W 122.1321300 240 NEW CY55P1B-FGC-3-80W-4K-240 FIXED NEW FOUNDATION AND POLE PER RENTON 16.5' 4' F40W LED 4,733 CYCLONE DOMIA STD PLAN 1 17.1. CYM55P 1 -FGC-3-40W-4K-240 0156TH AVE SE 30+93.5 54.5' RT N47.4754124 W 122.1320203 16.5 4' 240 NEW 40W LED 4,733 CYCLONE DOMIA FIXED NEW FOUNDATION AND POLE PER RENTON CYM55P 1-FGC-3-40W-4K-240 STD PLAN 117.2. * STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIOR TO IMPLEMENTING. ** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS. *** POLE ID NUMBERS SHALL BE PROVIDE BY ERIC CUTSHALL (CITY OF RENTON) FOR INCORPORATION INTO AS -BUILT PLANS AND INSTALLED BY THE CONTRACTOR IN ACCORDANCE WITH COR STD. PLAN 121. BENCHMARK FOUND PUNCHMARK IN 1%4" BRASS FOUND PUNCHMARK IN 1%4" BRASS DATUM DOME IN CONCRETE MONUMENT IN DOME IN 4X4 CASE 0.5' BELOW GRADE OBSERVED 0.4' BELOW GRADE 37555 HORIZONTAL DATUM: VERTICAL DATUM: (NAD 83/1 1) (NAD 83/1 1) NAD '83/'91 NAVD '88 N:175866.55, E:1319201.78 N:175852.22, E:1319809.82 FN 0. REVISION BY DATE APPR CONSTRUCTION RECORD DRAWING THIS CONSTRUCTION RECORD DRAWING IS A COPY OF THE APPROVED CONSTRUCTION DRAWINGS PREPARED BY BARGHAUSEN CONSULTING ENGINEERS, INC AND HAS BEEN EDITED TO REFLECT ASBUILT CONDITIONS. THE INFORMATION PROVIDED ON THESE RECORD DRAWINGS IS A COMBINATION OF FIELD SURVEYED INFORMATION AND DOCUMENTED FIELD REVISIONS. SURVEYED: I SCALE: DESIGNED: GRL/TDR DRAWN: GIRL ONE INCH CHECKED: TDR AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY APPROVED: CTB VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 1 16. 1. FURNISH AND INSTALL NEW NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL-03 & IL-04, AND PER CITY OF RENTON STD PLANS 116.1, 116.2, 119, 120 & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD DETAIL 121. D CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 1 17. 1. FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL-03 & IL-04, AND PER CITY OF RENTON STD PLANS 117.1, 117.3, 119, 120 & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD DETAIL 121. O3 EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. 40 EXISTING ARTERIAL STREET DECORATIVE LUMINAIRE POLE TO REMAIN. 50 EXISTING NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE POLE TO REMAIN. 6)THROUGH EXTEND NEW CONDUIT AND CONDUCTORS TO EXISTING JUNCTION BOX. ROUTE NEW CONDUCTORS EXISTING CONDUIT AND EXISTING JUNCTION BOX TO EXISTING SERVICE CABINET. CONNECT NEW CONDUCTORS TO SPARE CONTACTOR IN EXISTING SERVICE CABINET. IF SPARE CONTACTOR DOES NOT EXIST, FURNISH AND INSTALL NEW CONTACTOR AND CONNECT NEW CONDUCTORS TO NEW CONTACTOR. OEXISTING SERVICE CABINET TO REMAIN. CONTRACTOR SHALL FURNISH AND INSTALL NEW CONTACTOR AND CONNECT NEW ILLUMINATION CONDUCTORS TO IT. OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 117.2. FURNISH AND INSTALL NEW ARTERIAL STREET DECORATIVE PEDESTRAIN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL-03 & IL-04 AND PER CITY OF RENTON STD PLANS 117.2, 117.3, 119, 120 & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY OF RENTON STANDARD DETAIL 121. 9)THROUGH EXTEND NEW CONDUIT AND CONDUCTORS TO EXISTING JUNCTION BOX. ROUTE NEW CONDUCTORS EXISTING CONDUIT AND EXISTING JUNCTION BOXES TO EXISTING SERVICE CABINET AT THE CORNER OF NE 6TH ST & 156TH AVE SE. CONNECT NEW CONDUCTORS TO SPARE CONTACTOR IN EXISTING SERVICE CABINET. IF SPARE CONTACTOR DOES NOT EXIST, FURNISH AND INSTALL NEW CONTACTOR AND CONNECT NEW CONDUCTORS TO NEW CONTACTOR. CALL BEFORE YOU DIG: 1-800-424-5555 CITY OR + R RENTON Planning/Building/Public Works Dept. 70--79 2027 4- O 0. 00 C) 00 DN D_N Lu o`q- 4- 06 N a- � 0 u O z QO N M p co o CD L 00 1 ()NO Q j Lr) 3 O CN LD)m ~ CV LuC�>U Lu Q O - �C4 U U 0 Ln � C9% V) Q fn O L n O 00 Q w �o o T-418803 IN COMPLIANCE WITH CITY OF RENTON STANDARDS ASBUILT ILLUMINATION PLAN SUMPTER SHORT PLAT KIM GREER 5007 E CORAL LANE SPOKANE, WA 99223 T O 06 T AN H H H H H H J O� N = w 0 DATE: Z 10/19/2021 w m O FIELDBOOK: PAGE: C G� DRAWING NO: 1 L-02 �ui � v m SHEET: w w OF: 47 (�(F