HomeMy WebLinkAboutT-41880500 T I T O OC U) W I— n o U 0 N N 0 N Cn 0 E L N U) 0 a E Z3 / 0 Q U a E D In m N O N N 0 N 0 a_ r- 0 In a E 3 In r-� U 0 a_ DocuSign Envelope ID: F4136C70-1A89-4D3E-83C3-E2FO224FAF95 POLE & BRACKET CABLE, #12 AWG. SPLICES BETWEEN FUSE HOLDER AND LUMINAIRE FIXTURE SHALL NOT BE ALLOWED FUSE KITS QUICK REFER TO WSROT LOCKING DISCONNECT 3 AMP IN LINE LID STANDARD DUTY FUSE KITS S.E.C. OR EQUAL JUNCTION BOX TYPES 1 do 2 STANDARD PLAN J-40.10 SPLICE KITS CLEAR EPDXY SPLICE KITS ON ALL THRU WIRE RUNS — CONCRETE PAD DR SIDEWALK PER STD PLAN 120 24 (MIN) COVER 18 BARE COPPER GROUND WIRE 1 -#8 EQUIPMENT GROUND WIREW/GREEN INSULATION FROM SERVICE CABINET 2 - LIGHTING SYSTEM WIRES TO CONTACTOR (SIZED AS REQ'D.) GROUND LUG eZ GROUND CLAMP 2tl PVC CONDUIT 5/8'xB' COPPER CLAD GROUND ROD rO LUMINAIRE #$ GREEN INSULATED WIRE TO FIXTURE GROUND LUG CONCRETE FOUNDATION NOTES: 1. THIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM, ADDIMNAL ELECTRICAL EQUIPMENT MAY VARY. 2. MINIMUM GROUND WIRE SIZE SHALL BE #8, AS SHOWN ABOVE. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN #8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS. 3. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 4. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN INSULATED WIRE OF THE SAME SIZE SHALL RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE: POLE HANDHOLE. IF THE FIXTURE MANUFACTURER HAS A GROUND LUG A 08 GREEN INSULATED WIRE SHALL BE RUN FROM THE FIXTURE GROUND LUG TO THE POLE GROUND LUG. LUMINAIRE ELECTRICAL STD. p1,p,N _ 119 .` I+ PUBLIC WORKS WIRING SYSTEM DEPARTMENT GAZ 5/22JZ019 ii BENCHMARK FOUND PUNCHMARK IN 1y4" BRASS DATUM DOME IN CONCRETE MONUMENT IN CASE 0.5' BELOW GRADE OBSERVED HORIZONTAL DATUM: VERTICAL DATUM: (NAD 83/1 1) NAD '83/'91 NAVD '88 N:175866.55, E:1319201.78 DocuSigm Envelope ID: 5D3DBAIA-2D4D-18E8-BB23-8A2834885ME -• 1,47 LI-IMI • LIK P!JL JUNCTION BCX CCIN.CRETE PAD PLAN VIEW LUVINAIRE PnLE CONCRETE PAD r JiIIII:TiflIJ UL .Ii. .. LUMINAIRE CONCRETE PAD DETAIL GENERAL NOTES, 1 LUMINAIRE FQNCRETE FAD SHALL 13E USED IN AREAS OUTS+DE OF 51DfWA K C4ACRETE C-A55 FUR LUUINAIRE. CONCRETE PAD yIAII BE PER STU FLAN 135. 3 TQP OF LHUINAIP.E FOUNDATION ELEVATION 5HALL BE LOCATED AT BOTTOM OF LUMINAIRE CONCRETE PAD ELVATIDN OR BC]TTOM OF SIDEWALK ELEVATIUM - LUMINAIRE POLE AND AAFTION 13OX TYPE PER PLAN LUMINAIRE r, NCRETE PAP ACCAWOCATES TYPE 1 AND TYK 2 JJNGnON EOXES 1)KY A SB UILT ILLUMINATION DETAILS OF SUMPTER SHORT PLAT A PORTION OF SECTION 14, TOWNSHIP 23 N., RANGE 05 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON LUMINAIRE. POLE f IUNCTION BOX CONREr SDEWALk PLAN VIEW PER STD PLAN 102 LUMINAIRE POLL GONCRETr: SIDEWALK fi PER 5TD PLAN 102 1UNCTION BOX ~-LIJMryAIRk CONCRETE FOUNDATION SIDE VIEW LUMINAIRE WITH SIDEWALK DETAIL CONCRETE PAD L' JUNCTION BOY PLAN v3EV1 i4 COKCRETE PAD JUNCTION Box V1T:lr INDIVIDUAL JUNCTION BOX PAD DETAIL. LUMINAIRE CONCRETE STD. PLAN - I?C1 It PUDL.IC WORKS PAD/SIDEWALK AND XrP"VED 3/ 3 DEPARTMENT JUNCTION BOX CONCRETE PAD Gregg A. Zirnmd i11 6Z❑ x9 14. ec-a�c�:a�esa�E. FOUND PUNCHMARK IN 1y4" BRASS DOME IN 4X4 0.4' BELOW GRADE 37555 (NAD 83/11) N:175852.22, E:1319809.82 TIN REVISION FOR STD PLAN 117.1 - 3 4" TO 2" A- o �N rti c. .M DECAL: BEFLEC UR12ED GOT WC GOLD OR WHITE LEGEND ON BLACK BACKGROUND INSTALL DECAL KUM 3ERS VERTICALLY. INSTALL IN PRY WEATHER, 50' F OR ABOVE N[J?A8ERR4G EXAMPLES CURB FOR SMPI.AN ilb.1,1172,117.4- STREET LIGHT STANDARD PI;DL,IC WORKS DECAL NUMBERING SYSTEM D>;PAR MENT LED TYPE WATTAGE STD. PLAIN-- 121 _ PROV A-1r. CONSTRUCTION RECORD DRAWING THIS CONSTRUCTION RECORD DRAWING tS A COPY OF THE APPROVED CONSTRUCTION DRAWINGS PREPARED BY BARGHAUSEN CONSULTING ENGINEERS, INC AND HAS BEEN EDITED TO REFLECT ASBUILT CONDITIONS. THE INFORMATION PROVIDED ON THESE RECORD DRAWINGS IS A COMBINATION OF FIELD SURVEYED INFORMATION AND DOCUMENTED FIELD REVISIONS. SURVEYED: DESIGNED: GRL/TDR DRAWN: GIRL CHECKED: TDR BY DATE AP P R APPROVED: CTB SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M rn T co O O M W 1 LJ H H i 1 /4„ LOAD LINE 1 /4" FUSE I CUTTING RINGS FUSE KIT rnnvv rrr i VVTt JrLlk t 70--79 2027 4— O 0� cn 00 SPLICE K I T FUSE KIT & SPLICE KIT DETAILS 3 CN O p� ADOPTED — o6 (1)CITY U1�Y OF RENTON O v= O U STANDARD PLANS 7 L O } E N SO LST DATE: 04/04 Q ^` M 00 • CD CD L 00 0, 1 CD Q > Lr) 3 O CV L ~ N Lu�� C) � U Lu 0 0 0 O gm � CD O � U-c — tz U 0 09%Q 0 �> _ O = n O GO Q w L cN �CD �CD T-418805 IN COMPLIANCE WITH CITY OF RENTON STANDARDS J CALL BEFORE YOU DIG: 0 N 1-800-424-5555 DATE: Z 10/19/2021 w m It CITY OF ASBUILT ILLUMINATION DETAILS FIELDBOOK: 0 R RENTON PAGE: 7 • S U M P ER K M G R ESE R RT PLAT DRAWING N0: 2 W Planning/Building/Public works Dept. 5007 E CORAL LANE I L-04 D SPOKANE, WA 99223 SHEET: 46 OF:4/ (n m