HomeMy WebLinkAboutMFP21005797.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP21005797
IVR Number: 21005797
Permit Information
Permit Name: ExteNet Systems - Fiber - SOUTH RENTON - PHASE 2 - SEG 13 - S-007397
P-023584 - NW-WA - WINONASC-00236Address/Location:12/02/2021Application Date:1253600030Parcel Number: 3751 EAST VALLEY RD
Permit Type:01/03/2022Issue Date:Franchise
Permit Work Class:01/03/2023Expiration Date:Minor Utility
Job Number: S-007397 P-023584 - NW-WA - WINONASC-00236Franchise Type:Telephone
Description: ExteNet Systems Inc. master franchise agreement, ORD 6013 PHASE 2 SEG 13 S 007397 P 023584 NW WA
WINONASC 00236 FROM VAULT PLACE UNDER SOUTH RENTON PHASE 2 SEG 11 S 007397 P 023584 CTL
PLANS, ON THE WEST SIDE OF E VALEY RD, TRENCH (1) 4" CONDUIT SOUTH TO PROPOSED VAULT. PULL
INNERDUCT AND FIBER THROUGH. RESTORATION PER CITY OF RENTON STANDARDS.
Contacts
Name Address PhoneTypeBilling
MGC Permits
MGC Technical
6244 185th AVE NE, STE 250
REDMOND, WA 98052
ApplicantX
Michael Smith
North Sky Communications
21320 84th Ave S
Kent, WA 98032
Applicant
Rachel Fenton
Extenet Systems LLC
3030 Warrenville Road Warrenville
Rd, Suite 340
Lisle, IL 60532
Applicant
Michael Smith
Dycom Industries dba North Sky
11818 SE Mill Plain Blvd, SUITE 410
Vancouver, WA 98684
C: (206) 305-5881Contractor
Business License Number: 36846Construction Contractor: NORTHSC857Q4
CARMAX TAX DEPT PO BOX 29965
RICHMOND , VA 23242
Owner
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
MFP21005797
Monday - Friday 8:00AM - 3:00PM
Scott Warlick CED 1/3/2021
NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 2 - SEG 13NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 3751 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTH SKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 13 - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 11Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE WITH PEDESTRIAN ESCORT (FOR URBAN ARTERIAL ROADWAY'S)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYEAST VALLEY RDTRAFFIC CONTROL PLAN #1 - USE SET-UP WHERE APPLICABLE ALONG EAST VALLEY RD (SOUTH BOUND LANE)WORKVEHICLE2' MINW20-13750 EAST VALLEY RDPARCEL NO.30230590823820 EAST VALLEY RDPARCEL NO.30230590923751 EAST VALLEY RDPARCEL NO.1253600030WORK AREA1705 SQ FTFLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLSPOTTER ON SITETO ESCORT PEDESTRIANSTHROUGH WORK ZONESPOTTER ON SITETO ESCORT PEDESTRIANSTHROUGH WORK ZONENOTESPOTTER FLAGGERS TO PLACETEMPORARY ADA RAMPS/HARDSURFACES TO MAINTAIN 5' MINPEDESTRIANS ESCORT PATHACCESS ROAD W20-1W20-5RW4-2RXXX3701 EAST VALLEY RDPARCEL NO.1253600020W20-5RW20-1X
50'-100'MFP21005797
NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 13NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 3751 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 13 - PLANS.dwgPERMIT NUMBER: RSITE LOCATIONSHEET INDEXSCOPE OF WORK:FROM VAULT PLACE UNDER SOUTH RENTON -PHASE 2 - SEG 11 - S-007397 P-023584 - CTLPLANS, ON THE WEST SIDE OF E VALEY RD,TRENCH (1) 4" CONDUIT SOUTH TO PROPOSEDVAULT. PULL INNERDUCT AND FIBER THROUGH.Know what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 16ADDRESS: 3751 EAST VALLEY RD, RENTON, WA 98057PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 13 - S-007397 P-023584 - NW-WA - WINONASC-00236 - PLANS1. COVER SHEET / SITE LOCATION2. LEGEND3. GENERAL NOTES4. DESIGN VIEWS A5. UNDERGROUND DETAILS6. SITE PHOTOSCONTACTSMATT FRASERMGC TECHNICAL CONSULTING, INC.6244 185TH AVE NEREDMOND, WA 98052C.206.618.5254MATT@MGCTECHNICAL.COMNORTH SKY COMMUNICATIONS,LLC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C.206.305.5881MSMITH@NORTHSKY.COMSHEET 4STARTENDMFP21005797
NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 13NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 3751 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 13 - PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 26#F#F#F##LEGENDMFP21005797
NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 13NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 3751 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 13 - PLANS.dwgPERMIT NUMBER: RGENERAL NOTESKnow what'sbelow.before you dig.CallRGENERAL NOTES:UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTINGAND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTINGTHE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THEDISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK ISFOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALLOTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THECONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.SPECIFICALLY STATED OTHERWISE.CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCHALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF RENTON ENGINEERINGALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTHCONFIDENTIAL/PROPRIETARYSHEET: OF 36The locations of utilities shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. hereby disclaims any responsibilityto third parties for the accuracy of this information. Persons working in the area covered by this drawing must contact the statewideCall-Before-You-Dig System to ascertain the location of underground utilities prior to performing any excavation.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF RENTON REGULATIONS AND APPLICABLE STATEAND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIREINSPECTED AND APPROVED BY THE CITY OF RENTON INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TOBE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONTHESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THEFIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCALUTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTSUTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.CONTRACTOR SHALL NOTIFY THE CITY OF RENTON INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHTHE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF RENTON AND ALL UTILITY COMPANIES WITH REGARDACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLETHE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSTIMES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, ORALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESSFOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF RENTON, THE CONTRACTOR SHALL SUBMIT ATRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIESWITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH CITY OF RENTON.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THEINTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVEDOR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALLCONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT ATTHE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF RENTON INSPECTOR AT ALL TIMES.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATIONALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TOTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THETIME PERIOD APPROVED BY THE CITY OF RENTON.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.MFP21005797
NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 13NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 3751 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 13 - PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 46DESIGN VIEW A Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #---- FOR SITE PHOTOGRAPHS.3750 EAST VALLEY RDPARCEL NO.30230590823820 EAST VALLEY RDPARCEL NO.30230590923751 EAST VALLEY RDPARCEL NO.1253600030CONSTRUCTION NOTES1EXTENET VAULT PLACED UNDER, SOUTH RENTON - PHASE2 - SEG 11 - S-007397 P-023584 - CTL PLANS. CORE VAULTAND PLACE CONDUIT FROM TRENCH. PULL (1) 144F CABLETHROUGH. CONTRACTOR TO VERIFY CORRECT VAULTPRIOR TO START OF CONSTRUCTION.RESTORATION NOTESARESTORE LANDSCAPE PER CITY OF RENTONSTANDARDS.GRESTORE SIDEWALK PANEL PER CITY OFRENTON STANDARDS.E VALLEY RDACCESS ROAD
1MATCH TO
SOUTH RENTON -
PHASE 2 - SEG 11 -
S-007397 P-023584 -
CTL PLANS
12A3A2G5'164'4'6'4'3'1'2'
78'
38'40'
12'11'13'11'
10'
6'2PROPOSED OPEN TRENCH (1) 4" CONDUIT, REPAIRSURFACE AS PER CITY OF RENTON STANDARDS. PULL(3)1.25 INNERDUCT AND (1) 144F CABLE THROUGH.3PROPOSED (1) 233LA VAULT, CORE VAULT AND PLACECONDUIT. REPAIR SURFACE AS PER CITY OF RENTONSTANDARDS. COIL (1) 144F CABLE THROUGH.MFP21005797
NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 13NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 3751 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 13 - PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 56233LA VAULT DETAILSCALE: NTSNo. 23-2436PVAULTNo. 233-BLCOVERMANHOLE COVER AND FRAMELOADING: BUILT TO AN H2O RATING UP TO 150 KIPTYPICAL TRENCH IN SOIL DETAILSCALE: NTSEXISTING GROUNDWARNING TAPEBACKFILL(8" LAYERS)6" MIN.12"36" MIN. DEPTH4"BACKFILL(COMPACTED @ 90%)HDPE DUCTCLEAN BACKFILLBACKFILL(COMPACTED EARTH @ 90%)6" MNRL AGG TYPE 2(COMPACTED AS SPECIFIEDIN CONTRACT DOCUMENTS)TYPICAL CONCRETE SIDEWALK PANEL CROSS SECTION DETAILSCALE: NTSNEW PANEL-MATCH EXISTINGEXPAND TO JOINTMATCH EXISTING24"12"6"6"6" MIN. TYPE 2 CRUSHEDROCKCOMPACTED BACKFILL6" SAND COVER6" SAND BEDDINGUNDERGROUND TYPICALSMFP21005797
NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 13NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 3751 EAST VALLEY RD RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 13 - PLANS.dwgPERMIT NUMBER: RSITE PHOTOGRAPHSCONSTRUCTION NOTESKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 66PHOTO #1: FACING NORTH ON WEST SIDE OF EAST VALLEY RDPHOTO #2: FACING NORTH ON WEST SIDE OF EAST VALLEY RD123231EXTENET VAULT PLACED UNDER, SOUTH RENTON - PHASE2 - SEG 11 - S-007397 P-023584 - CTL PLANS. CORE VAULTAND PLACE CONDUIT FROM TRENCH. PULL (1) 144F CABLETHROUGH. CONTRACTOR TO VERIFY CORRECT VAULTPRIOR TO START OF CONSTRUCTION.2PROPOSED OPEN TRENCH (1) 4" CONDUIT, REPAIRSURFACE AS PER CITY OF RENTON STANDARDS. PULL(3)1.25 INNERDUCT AND (1) 144F CABLE THROUGH.3PROPOSED (1) 233LA VAULT, CORE VAULT AND PLACECONDUIT. REPAIR SURFACE AS PER CITY OF RENTONSTANDARDS. COIL (1) 144F CABLE THROUGH.MFP21005797