HomeMy WebLinkAboutP_East_SFR-Architectural_Set-R1_220124_v1N 35TH STREET8"20'-0"MIN REAR YARD5'-0"MIN SIDEYARD20'-0" MIN FRONT YARD 5'-0"MIN SIDEYARDDNDNDNEXISTING HOUSE TOBE DEMOLISHEDCOVERED PATIO166.47'PROPOSEDSINGLE-FAMILYRESIDENCEENTRYPROPOSED2-CARGARAGE1ST FLOOR166.67'COVEREDPORCH166.47'GARAGE163.0'PROPOSED WALKWAY EXISTING DETACHEDGARAGE TO BEDEMOLISHEDPROPOSED DRIVEWAY(APPROX. 7.8% SLOPEDOWN TO ROW)4'-012"3'-8"FIREPLACEBAY2'-0"6'-818"1'-1112"DOWNSPOUTS,TYP.DOWNSPOUTS,TYP.166.1' N166.1' E165.0' N165.0' E164.7' N164.7' E165.8' N165.8' E162.7' N162.7' E6'-0"166.3' E164.0' E165.2' E6" EXISTING TREE TOBE REMOVEDPROPOSED 2 NEWSIGNIFICANT TREESEXISTINGCONCRETE SLAB TOBE REMOVED162.0' E6'-0"6'-0"6'-0"DASHED LINE 6' AWAY FROM EXTERIORWALL TO DETERMINE GRADE PLANEELEVATION, TYP.ROOFABOVEROOF ABOVEINCLUDING GUTTERS17'-6"RED LINES INDICATEREQUIRED YARDS, TYP.1'-6"REQUIRED 1.5'ROW DEDICATIONROW CENTERLINE(TO BEREMOVED, TYP.)NEW SIDEWALKNEWPLANTINGSTRIPPROPOSEDNEW CURBEXISTING CONCRETESURFACE TO BE REMOVEDEXISTING EDGEOF ASPHALTEXISTING CONCRETEWALKWAY TO BEREMOVED, TYP.CONCRETECONCRETEPORCHADJACENT HOUSEADJACENT RESIDENCEPROPOSED UNDER ASEPARATE PERMITAPPLICATION27'-812"PROPOSEDREAR YARD5'-012"(E) BLOCKWALL TO BEREMOVED58'-6"40'-0"5'-0"NEW ROW TREEPER LANDSCAPEPLAN16'-0"SITE ADDRESS1218 N 35TH STREETRENTON, WA 98056OWNERSTRAIGHT ARROW HOMES, LLC12015 NE 8TH STREET SUITE 5BELLEVUE, WA 98005BRANDON SHIMIZU- MEMBER425-443-5458brandon@meadinvestments.comSCOPE OF WORKDEMOLITION OF AN EXISTING HOUSE & DETACHEDGARAGE, CONSTRUCTION OF A NEW SINGLE-FAMILYRESIDENCE, WITH ATTACHED GARAGECONSTRUCTION TYPEV-B, WOOD FRAMEOCCUPANCYR-3ZONER-8FRONT YARD SET BACKREQUIRED: MIN. 20'-0"PROPOSED: 20'-0"REAR YARD SETBACKREQUIRED: MIN. 20'-0"PROPOSED: 27'-8 1/2"SIDE YARD SETBACKREQUIRED: MIN. 5'-0"PROPOSED: 5'-0" EAST SIDE & 5'-0 1/2" WEST SIDEHEIGHT LIMITMAXIMUM WALL PLATE HEIGHT IS 24' MEASURED FROM THE GRADEPLANE (AVERAGE GRADE). ROOF PITCH EQUAL OR GREATER THAN4:12 MAY PROJECT AN ADDITIONAL 6' FROM THE MAX. WALLPLATE HEIGHT.SEE GRADE PLANE CALCULATIONS BELOW & ELEVATIONS ONSHEET A-5.LEGAL DESCRIPTIONHILLMANS LK WN GARDEN OF EDEN #1 LOT27 TGW PORTION OF VACATED ALLEYADJOININGPLAT BLOCK: 20PLAT LOT: 27TAX PARCEL NUMBER334210-2885A-1SURVEYA-2A-3A-4A-5A-6A-7A-8A-9A-10A-11SITE PLAN/ PROJECT DATASURVEYARCHITECTURAL NOTESFLOOR PLANSROOF PLAN & SECTIONSELEVATIONS3D VIEWSENERGY WORKSHEETSARCHITECTURAL DETAILSARCHITECTURAL DETAILSBUILDING ENCLOSURE DETAILSBUILDING ENCLOSURE DETAILSMAXIMUM BUILDING COVERAGELOT SIZE: 5,405 SF-MAX BUILDING COVERAGE: 50% 5,405 x 0.5 = 2,702.5 SF MAX ALLOWEDPROPOSED: -HOUSE GROUND FLOOR: 1,968 SF -COVERED FRONT PORCH: 49 SF -COVERED BACK DECK: 234 SF-2ND FLOOR CANTILEVER: 78 SF TOTAL: 2,329 SF = 43.08%-MAX IMPERVIOUS SURFACE: 65%5,405 x 0.65 = 3,513 SF MAX ALLOWEDPROPOSED: -BUILDING LOT COVERAGE (SEE ABOVE): 2,329 SF-DRIVEWAY, STEPS, WALKWAY: 558 SF TOTAL: 2,887 SF = 53.41%-MIN TREE DENSITY: 2 SIGNIFICANT TREES PER 5,000 SF5,405 / 5,000 = 1.08 X 2 = 2 SIGNIFICANT TREES REQUIRED/ PROPOSED.1ST FLOOR 1,500 SF2ND FLOOR 1,857 SFTOTAL 3,357 SFCONDITIONED AREAGARAGE462 SF -462 SFDRAWING INDEXFLOOR AREA CALCS.VICINITY MAPPROJECT DATASTRAIGHT ARROW N 35TH ST RENTON@A.B.AS REQ'DBDRMBWPC.B.CLCONT.dDADUDBLDIAD.F.DWEXIST.FACE OF STUDGYPSUM WALL BOARDHEADERF.O.S.G.W.B.HDRHEM-FIRHEIGHTINSULATIONNUMBER OF JACK STUDS (BEARING)OVER HANGON CENTERPLYWOODPRESSURE TREATEDREFRIGERATORSINGLE-FAMILY RESIDENCETO BE DETERMINEDTYPICAL IN THIS APPLICATIONUNLESS NOTED OTHERWISEWITHWALK-IN CLOSETWATER HEATEREXISTINGNEWH.F.HT.INSUL.NJO.H.O.CPLYWDP.T.REFSFRTBDTYP.U.N.O.w/W.I.C.WH(E)(N)ATANCHOR BOLTAS REQUIRED BY CODE, MANUFACTURER'SRECOMMENDATIONS OR GOOD PRACTICEBEDROOMBRACED WALL PANELCATCH BASINCENTER LINECONTINUOUSPENNY WEIGHT FOR NAILSDETACHED ACCESSORY DWELLING UNITDOUBLEDIAMETERDOUGLAS FIRDISH WASHEREXISTINGABBREVIATIONSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINK TEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUESAFETY PRECAUTION SHALL BE IMPLEMENTED BY CONTRACTOR(S) AT ALL TRENCHING INACCORDANCE WITH CURRENT OSHA STANDARDSCall 2 Working Days Before You Dig1-800-424-5555Utilities Underground Location Center(ID,MT,ND,OR,WA)EXISTING CONTOURLINE TO REMAINNEW CONTOUR LINEEXISTING CONTOUR LINE TOBE MODIFIEDLEGEND236EXTERIOR LIGHTINGEXTERIOR LIGHTING SHALL BE SHIELDED AND DIRECTED AWAY FROM RESIDENTIALLYZONED LOTS. THE DIRECTOR MAY REQUIRE THAT THE INTENSITY OF ILLUMINATION BELIMITED AND THAT THE LOCATION OF THE LIGHTING BE CHANGED.SITE PLANSCALE: 1/8" = 1'-0"NLOT SIZE5,405 SFENERGY CODEPROJECTSITEAVERAGE GRADE ELEVATION AT EACH EXTERIOR WALL:NORTH: (164.0+166.1)/2= 165.05WEST: (164.0+162.0)/2= 163.00SOUTH: (162.0+165.0)/2= 163.50EAST:(165.0+166.1)/2= 165.55TOTAL: 657.10 / 4 = 164.28 = ELEVATION OF GRADE PLANETHIS PROJECT: MEDIUM DWELLING UNIT- 6 CREDITS REQUIRED.PROPOSED:Table R406.2 - Fuel Normalization CreditsOption 4: ELECTRIC RESISTANCE W/ DUCTLESS MINI-SPLIT HEAT PUMPPER R403.7.1 - 0.5 CREDITTable R406.3 - Energy CreditsOption 1.3: EFFICIENT BUILDING ENVELOPE - 0.5 CREDITSOption 2.3: AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION - 0.5 CREDITOption 3.4: HIGH EFFICIENCY HVAC EQUIPMENT - 1.5 CREDITSOption 5.5: EFFICIENT WATER HEATING - 2.0 CREDITSTotal of 6.0 credits proposed(REFER TO SHEET A-2 FOR THE DESCRIPTION OF EACH OPTION)PROJECT IS REQUIRED TO HAVE A BLOWER DOOR TEST TO VERIFYCONFORMANCE WITH AIR LEAKAGE LIMITS.SITE PLAN/ PROJECT DATA A-1SHEET TITLE: PROJECT:SHEET NUMBER:STRAIGHT ARROW N 35TH ST RENTON 1218 N 35th Street Renton, WA 98056 COPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" x 36"NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEET 1951.07209 Greenwood Avenue NorthSeattle, Washington 98103206-782-2911Fax 782-5624CLIENT:CONSULTANT:REVISIONS:DATE: JOB NUMBER: SCALE:DRAWN BY:01 OCTOBER 2021AMStraight Arrow Homes, LLC12015 NE 8th Street Suite 5Bellevue, WA 98005AS SHOWNEquilibria StructuralEngineering9999 Harbour Place, Suite 107Mukilteo, WA 98275360-386-9476PR21000259B2100526727 DECEMBER 20211 GENERAL REQUIREMENTS A. Provide all required temporary facilities and all temporary utilities as required to keep facility in operation during construction. Contractor is responsible for all costs associated with temporary facilities and temporary utilities. B. Construction Barricades: Provide construction barricade as required to keep Public and Employees safe, following all applicable federal, state and city codes and regulations. DRAWINGS / PERMITS BY OTHERS: It is the contractor's responsibility to provide additional drawings and permits as required to complete this project. The following list is by no means meant to be comprehensive, rather suggestive of the possible types of additional permits, drawings, and submittals that may be required during the course of the project. Depending on the project, some of the following permits, drawing, and submittals could come up including others not listed below: Provide Drawings / obtain Permit for Plumbing Work, Mechanical / Furnace Work, Electrical Work. Any deferred submittals shall be submitted to the Building Department for review and approval (if any). FRAMING (Project specific structural engineering shall govern) A. All materials and workmanship shall conform to the requirements of the drawings. notes, specifications, and all applicable codes and ordinances. See structural drawings. B. Columns and posts located on concrete or masonry floors or decks exposed to the weather or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used. The pedestals shall project at least 6 inches above exposed earth and at least 1 inch above such floors. Section R317.1.4 I.R.C. GENERAL NOTES 2018 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) with Washington State Amendments A. These notes are in abbreviate form. The intent is to further define those areas of work not clearly delineated on the drawings. The quality of workmanship throughout shall be first class and all materials shall meet or exceed the normal industry standards applicable in each case. B. All work is to be performed in strict compliance with the 2018 International Residential Code (I.R.C.) with Washington State Amendments, the 2018 Washington State Energy Code and all applicable provisions of prevailing local, state, and federal codes and ordinances, including appropriate licensing laws including any local amendments and compliance with the Land Use code / Zoning Ordinance. C. Notify and consult with Architect if discrepancies are found between drawings an site conditions and/or building or zoning requirements prior to start of Work. Any consequences resulting from these discrepancies will be the Contractors sole responsibility and expense if Architect is not consulted before area in question is constructed. D. Contractor shall verify field conditions prior to start of work. If measurements or conditions differ from drawings, notify Owner prior to start of work. Bring any conflicts to the attention of the Architect whereupon a final decision will be made. E. Dimensional strings are generated by a computer drafting program that usually rounds the dimension to the nearest 1/8 of an inch. Therefore, it would be possible that a string of multiple dimensions and an overall dimensions of the same string could vary by 1/8 of an inch. Please notify the Architect whether a verification of a dimension is needed or dimensions to 1/16" are required. F. Unless noted otherwise, dimensions are to face of studs, face of foundation walls, centerline of columns, face of window openings and inside of door jambs. G. Do not scale drawings. During the reprographic process, proportions may have been altered. Use written dimensions. Where conflicts exist, notify the Architect immediately. H. The details shown are typical and shall be used for like or similar conditions not shown. I. Contractor to maintain in force at all times, insurance as required by Article 11 of the General Conditions of the Contract for Construction, AlA Document A201. Certificates evidencing said insurance shall be provided to the Owner, prior to commencement of any work. J. Contractor is solely responsible for all construction means and methods and shall maintain the structural integrity of any construction until all final lateral and vertical load carrying systems are completed - approvals from the architect do not extend to approval of construction means and methods. K. Drawings are for a complete installation with fully-functional assemblies - contractor is to field verify all dimensions and conditions prior to any work and shall be responsible for all work and materials including those finished by subcontractors. L. The Contractor shall coordinate with the Building Department for all Building Department required inspections. ELECTRICAL A. Electrical work shall be performed in a "BIDDER-DESIGN" manner. The Contractor shall submit such systems separately for permit. It is the Contractors responsibility to design systems that meet all requirements and codes. Contractor shall submit drawings, pay for, and obtain permit and perform work in a manner that meets or exceeds the recognized workmanship standards for the industry. B. All drawings are to be submitted for review and approval to the Owner before performing Work. Specific attention is to be paid regarding Owner requested locations of electrical, phone and computer cabling port locations. C. Proper protection shall be provided around recessed light fixtures per manufactures recommendations so that overheating will not occur. Recessed light fixtures to be I.C. rated. D. Light switches and outlets to be away from jambs and corners 8" min. to allow for trim. SMOKE ALARM/DETECTORS per I.R.C. R314 and CARBON MONOXIDE ALARMS per I.R.C. R315 A. Smoke alarms shall be installed in the following locations (R314.3): 1. Inside each sleeping room or sleeping loft (see 4) 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms (see 4) 3. On each additional story of the dwelling, including basements and habitable attics (see 4 & B) 4. NOT within 3' of a door or opening of a bathroom that contains a bathtub or shower, unless that is the only available location. 5. In napping areas in family home childcare B. Interconnection (R314.4): Where more than one smoke alarm is required to be installed within an individual dwelling unit in accordance with Section R314.3, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the individual dwelling unit. Where an accessory dwelling unit is created within an existing dwelling unit all required smoke alarms, in the accessory dwelling unit and the primary dwelling unit, shall be interconnected in such a manner that the actuation of one alarm will activate all alarms in both the primary dwelling unit and the accessory dwelling unit. Physical interconnection of smoke alarms shall not be required where listed wireless alarms are installed and all alarms sound upon activation of one alarm. Exception: if existing smoke alarms are not interconnected, or new and existing alarms are not capable of being interconnected. C. Where alterations, repairs or additions requiring a permit occur, where one or more sleeping rooms are added or created in existing dwellings, or where an accessory dwelling unit is created within an existing dwelling unit, each dwelling unit shall be equipped with smoke alarms as required for new dwellings. D. All smoke alarms shall be listed in accordance with UL 217 and installed in accordance with the provisions of the I.R.C. Heat detectors and heat alarms shall be listed for the intended application. Combination smoke and carbon monoxide alarms shall be listed in accordance with UL 217 and UL 2034. Smoke alarms, heat detectors and heat alarms shall comply with NFPA 72 and I.R.C. R314 . E. Fire alarms systems shall be permitted to be used in lieu of smoke alarms and shall comply with the provisions of the I.R.C. and the household fire warning equipment provisions of NFPA 72, and shall be listed in accordance with UL 268. F. A heat detector or heat alarm shall be provided in new attached garages, and shall be rated for the ambient outdoor temperatures and humidity shall be installed in new garages that are attached to or located under new and existing dwellings, shall be installed in a central location in accordance with the manufacturer's instructions. Heat detectors and heat alarms shall not be required in dwellings without commercial power. Heat detectors and heat alarms shall be connected to an alarm that is installed in the dwelling unit, and shall be located in a hallway, room, or other location that will provide occupant notification. G. Carbon Monoxide Alarm locations shall be installed OUTSIDE of each separate sleeping area in the immediate vicinity of bedrooms (on each level of the dwelling unit), and on each level of the dwelling (R315.2.1) and WITHIN a bedroom that has a fuel-burning appliance (such as a gas fireplace) per R315.3. H. Single station carbon monoxide alarms shall be listed as complying with UL 2034 and shall be installed in accordance with the I.R.C. and manufacturer's installation instructions. DRYWALL FINISH A. Provide 1/2" gypsum wall board for non-rated assemblies and 5/8" type "X" gypsum wall board for 1-hour rated assemblies with all exposed joints and fastener heads smooth and flush with surface of board. Joints taped and prepared for application of finish. B. Per I.R.C. Section R302.7 enclosed space under stairs that is accessed by a door or access panel shall have walls, under stair surface and any soffits protected on the enclosed side with 1/2" GWB. C. "Recommended Specifications for the Application and Finishing of Gypsum Board," latest edition, as published by the Gypsum Association (also published as ANSI 97.1 and "Using Gypsum Board and Ceilings", latest edition). Install for 1 hour fire-rating as governed by local codes. F. All GUARDRAILS to be 36" high minimum from finished floor line. Openings in railing assemblies are to be less than 4" in one direction. Guard Live Load Requirements per I.R.C. Table R301.5: for guardrails and handrails 200 lbs (a single concentrated load applied in any direction and at any point along the top) and for guardrail in-fill components 50 lbs (guard-rail infill components except the handrail, balusters and panel fillers shall be designed to withstand a horizontally applied normal load of 50 lbs on an area equal to 1 SF. This load need not be assumed to act concurrently with any other live load requirements.) Glazing used in handrail assemblies and guards shall be designed with a safety factor of 4. The safety factor shall be applied to each of the concentrated loads applied to the top of the rails, and to the load on the in-fil components. These loads shall be determined independent of one another, and loads are assumed not to occur with any other live load. Handrails to be between 1 1/2" dia. and 2" dia., with clearance of 1 1/2" between rail and wall surface. Mount between 34" and 38" off stair nosing. G. DECKING: All wood exposed to weather, such as wood used for deck framing including, decking, railings, joists, beams, and posts shall be pressure treated or of wood with natural resistance to decay. H. SIDING RELATIVE TO EARTH OR CONCRETE PATIOS, ETC: Clearance between wood siding and earth on the exterior of a building shall not be less than 6 inches. Clearance between wood siding and concrete steps, slabs, patios, and similar shall not be less then 2 inches. Exception: when such siding is naturally resistant or P.T. 317.1 I.R.C. CEILING HEIGHT per I.R.C. R305 A. Habitable space, hallways and portions of basements containing these spaces shall have a ceiling height not less than 7 feet measured from FINISH floor to FINISH ceiling. Beams can NOT project below the required ceiling height. B. Bathrooms, toilet rooms and laundry rooms shall have a min. ceiling height of 6'-8" at the center of the front clearance area for fixtures. C. Sloped Ceilings: For rooms with sloped ceilings at least 50% of the REQUIRED floor area of a room/space must have a ceiling height of 7'-0" with no ceiling height less than 5'-0" (i.e. minimum REQUIRED bedroom is 70 SF per R304.1, so at least 35 SF of a bedroom needs to have ceiling heights over 7 feet and the other 35 SF over 5 feet). D. Portions of the basement that do not contain habitable space or hallways shall have a ceiling height of not less than 6'-8". At beams, girder, ducts or other obstructions, the ceiling height shall be not less than 6'-4" from the finished floor. E. Minimum areas for habitable rooms per I.R.C. R304: Habitable rooms shall have a floor area of not less than 70 SF, and not lest than 7' in any horizontal dimension. Kitchens are exempt from minimum area and dimensions. F. I.R.C. Definition of Habitable Space: A space in a building for living, sleeping, eating or cooking. Bathrooms, toilet rooms, closets, halls, storage or utility spaces and similar areas are not considered habitable spaces. STAIRS A. I.R.C. R311.7 , MIN 36" WIDE, MAX. RISER = 7 3/4", MIN. TREAD = 10". Clear width of stairs shall not be less than 31 1 2" where there is handrail on one side, and not less than 27" where handrails are on both sides. Handrails shall not project more than 4 1/2" on either side of the stairway. B. Landings: There shall be a floor or landing at the top and bottom of each stairway except a door swinging away from the stairs is OK for interior stairs. The width of each landing shall not be less than the width of the stairway served, min. 36" in the direction of travel. Max. 2% slope. C. Handrails: 34" to 38", min 1 1/2" clear from wall, continuous from full-length of flight where risers are. Handrail ends shall be returned or terminate in newel posts or safety terminals. New posts can interrupt handrails at a turn in a flight with winders, at a landing, or over the lowest tread . The lowest tread may have a volute, turnout or newel. Handrails shall be of the two types listed in I.R.C. 311.7.8.5. or provide equivalent graspability. D. The minimum headroom at stairs shall be 6'-8" measured vertically from a sloped plane adjoining the tread nosing (if applicable). EXTERIOR WALLS, ROOF ASSEMBLIES & WEATHER PROTECTION A. Building Enclosure Design: For Building Enclosure Notes sheets at near end of the set. EXHAUST A. RANGE EXHAUST & DRYERS: Domestic kitchen range ventilation and domestic clothes dryers ducts shall have smooth interior surfaces, shall be substantially airtight, shall be equipped with a back-draft damper and shall comply with the provisions of Chapter 15, sections M1502 and M1503 I.R.C. The exhaust system shall be independent of all other systems. . B. Moisture exhaust ducts for clothes dryers shall terminate on the outside of the building and shall be equipped with a back-draft damper. Screens shall NOT be installed at the duct termination. Ducts for exhausting clothes dryers shall NOT be connected or installed with sheet metal screws or other fasteners which will obstruct the flow. . C. Unless otherwise permitted or required by the dryer manufacturer's installation instructions and approved by the building official, dryer exhaust ducts shall have a 4 inch diameter; the maximum length of the exhaust duct shall be 35' from the connection to the transition duct from the dryer to the outlet terminal. Where fittings are used, the maximum length of the exhaust duct shall be reduced in accordance with I.R.C Chapter 15, Table M1502.4.5.1. The maximum length of the exhaust duct does not include the transition duct. FIRE-RESISTIVE REQUIREMENT NOTES A. CONSTRUCTION TYPE V-B (Table 601 I.B.C) Interior & Exterior Bearing Walls, & Non-Bearing Walls to be Type V-B construction as required. NOTE: All voids under stairs shall be 1-Hour Rated Construction per plans and details. . B. TYPES OF CONSTRUCTION: Standards of Quality - Construction materials shall be labeled appropriately, as required by the local municipality, showing that they comply with local code standards for such materials as building paper, decking material, foam plastics, wall and roofing materials. VENTILATION and INDOOR AIR QUALITY A. SOURCE SPECIFIC VENTILATION REQUIREMENTS per I.R.C. Chapter 15, M1505 Local exhaust fans are required in each bathroom, toilet room and kitchen and shall have the capacity to exhaust the minimum airflow rate in accordance with Table M1505.4.4: - Kitchens = 100 cfm intermittent, or 30 cfm continuous - Bathrooms and toilet rooms = 50 cfm intermittent, or 20 cfm continuous WATER CONSERVATION NOTES A. Water Heating is per 'F' under ENERGY CODE NOTES DOORS AND WINDOWS A. Doors as selected by Owner, but must meet code, egress, hardware requirements. All exits shall be operable from the inside without the use of a key or special knowledge. Doors leading into the living area from the garage shall be self-closing and self-latching. B. See Floor Plans for Sizes of doors and windows. Rating and Required U-Values shall be per plan and as set forth on this sheet. See schedules attached or in drawings. All exterior doors, windows and skylights shall be NFRC certified. C. All Glazing within 24" of a door to be tempered, including any glass shower or tub doors. Additionally, glazing within 5 feet of the bottom or top of stairways where the sill is less than 60" AFF shall be Safety Glazed. I.R.C. R308.4 specifies other hazardous locations also requiring safety glazing. D. Egress windows from sleeping rooms and basements with habitable space w/o sleeping room to have a minimum net clear opening of 5.7 SF, minimum of 24" clear height, 20" minimum clear width, with maximum sill height of 44" above finished floor. Exception: Grade floor or below grade openings can have a minimum net clear opening of 5.0 SF per Exception under I.R.C. R310.2.1 . E. Window Well: Egress windows with a finished sill height that is below the adjacent grade level shall be provided with window wells that allow the window to be fully opened and provide a minimum clear opening of 9 SF, with a minimum dimension of 36". Window wells with a vertical depth of more then 44" shall be provided with an approved permanently affixed ladder w/ minimum inside width of 12" complying w/ R311.7 , or stairs that are accessible with the window in the fully open position. The ladder shall not encroach into the 36" dimension by more than 6" per I.R.C. R310.2.3 Exception . Window wells shall be designed for proper drainage by connecting to building's foundation drainage system or by an approved alternate method, unless the foundation is on a well-drained soil or sand-gravel mixture soils as described in Table R405.1 . C. Wood framing members, INCLUDING wood sheathing, that are in contact with exterior foundation walls and are less than 8 inches from exposed earth shall be of naturally durable or preservative-treated wood (P.T. wood). Section R317.1 I.R.C. D. Fire-blocking, draft-stops, and fire-stops to be per I.R.C. Ensure Fire Blocks meet I.R.C. Sections 302.11 and 602.8 requirements at horizontal & vertical within framing, and for all areas including furred spaces, concealed spaces at stairs, openings around vents, ducts & other penetrations, soffits, drop & cove ceilings. E. Where installation includes manufactured products, comply with the manufacturer's applicable instructions and recommendations for installation. Verify rough-in dimensions for equipment and provide buck-outs, backing and jacks as required F. ENERGY CREDITS: (R406) Additional Energy Efficiency Requirements: 1. Small Dwelling Unit (dwelling units less than 1,500 sf w/ less than 300 sf of fenestration, or addition between 500 - 1500sf): 3.0 credits 2. Medium Dwelling Unit (all dwelling units not small or large): 6.0 credits 3. Large Dwelling Unit (units over 5,000sf): 7.0 credits 4. Dwelling units serving R-2 occupancies: 4.5 credits 5. Additions less than or equal to 500 sf: 1.5 credits Main House 3,357 SF: MEDIUM DWELLING UNIT- 6 CREDITS REQUIRED. PROPOSED: Table R406.2 - Fuel Normalization Credits Option 4: ELECTRIC RESISTANCE W/ DUCTLESS MINI-SPLIT HEAT PUMP PER R403.7.1 - 0.5 CREDIT Table R406.3 - Energy Credits Option 1.3: EFFICIENT BUILDING ENVELOPE - 0.5 CREDITS Prescriptive compliance is based on Table 402.1.1 with the following modifications: Vertical fenestration U = 0.28 / Floor R-38 / Slab on grade R-10 perimeter and under entire slab / Below grade slab R-10 perimeter and under entire slab Option 2.3: AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION - 1.5 CREDIT Compliance based on R402.4.1.2: Reduce the tested air leakage to 1.5 air changes per hour maximum at 50 Pascals, and; All whole house ventilation requirements as determined by Section M1505.4 of the International Residential Code or Section 403.4.4 of the International Mechanical Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.75. Option 3.4: HIGH EFFICIENCY HVAC EQUIPMENT - 1.5 CREDITS Ductless mini-split system heat pump system. Zonal control: In homes where the primary space heating system is zonal electric heating, a ductless mini-split heat pump system with a minimum HSPF of 10.0 shall be installed to provide heating to the largest zone of the unit. Option 5.5: EFFICIENT WATER HEATING - 2.0 CREDITS Electric heat pump water heater meeting the standards for Tier III of NEEA's advanced water heating specification Total of 6.0 credits proposed A.ENERGY CODE NOTES 2018 WASHINGTON STATE ENERGY CODE B.BUILDING AIR LEAKAGE SEALS & WEATHER STRIPPING: (R402.4) Exterior joints around windows door frames, openings between walls and foundation, walls or roofs and all penetrations shall be sealed, caulked, gasket or weather stripped to limit air leakage. Other exterior joints shall be similarly treated, taped or covered with moisture vapor permeable house wrap. . C.BUILDING AIR LEAKAGE TESTING: (R402.4.1.2 TESTING): As coordinated with inspector, verify with each project. Dwelling units shall be tested and verified as having an air leakage rate of not exceeding 1.5 air changes per hour per energy credit 2.3 below, testing shall be conducted by an approved 3rd party. Perform testing per code requirements. . D.HVAC CONTROLS: Each dwelling unit is required to be provided with at least one programmable thermostat for the regulation of temperature (R403.1). . E.DUCT TESTING: (R403.3.3) Ducts shall be leak tested in accordance with WSU RS-33, if ducts are not entirely within building thermal envelope, they shall be insulated minimum R-8, and when ducts are within a concrete slab or in the ground shall be insulated with minimum R-10 (R403.3.1). Contractor to follow all other instructions per SEC for the duct testing and required insulation. . F.LIGHTING: (R404.1) A minimum 90% of permanently installed lamps shall be high-efficacy. . G. MOISTURE VAPOR RETARDERS: Per I.R.C. Section R702.7 install a vapor retarder (such as craft paper faced insulation, a special interior paint, vapor retardant foil or other approved vapor retarders) in all framed walls, floors and roof ceiling elements of the building thermal envelope on the warm-in-winter side of the insulation, except at unvented roof assemblies. In wet areas such as shower stalls install vapor barrier behind cement backer board or install a waterproof membrane such as Schluter-Kerdi or approved equal over cement backer board. Install vapor barrier behind tubs and fiberglass tub-shower surrounds. . I. INSULATION GLAZING/ VAPOR RETARDER: Residential Spaces are to follow the below Envelope Criteria: 2018 WA STATE Energy Code, Table R402.1.1, "Insulation and Fenestration Requirements by Component" for Climate Zone Marine 4: (R-values are minimums, U-factors are maximums) - Fenestration U-Factor: 0.30 --> This project 0.28 per energy credit 1.3 above - Skylight U-Factor: 0.50 - Ceiling R-Value: R-49, for single rafter- or joists- vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth extends over the top plate of the ext. wall. - Wood Frame Wall R-Value: 21 int - Floor R-Value: R-30 --> This project R-38 per energy credit 1.3 above - Below-Grade Wall R-Value: R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus an R-5 thermal break between the slab and the basement wall at the interior of the basement wall (or R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall.) - Slab R-Value & Depth: R-10, 2 ft --> This project both slab on grade and below grade shall have min R-10 continuous insulation under entire slab per energy credit 1.3 above - Headers shall be insulated with a minimum of R-10 insulation (See Glazing Schedule and Heating Equipment Sizing forms.) MECHANICAL A. HVAC and Plumbing work shall be performed in a "BIDDER-DESIGN" manner. The Contractor shall submit such systems separately for permit. It is the Contractors responsibility to design systems that meet all requirements and codes. Contractor shall submit drawings, pay for, and obtain permit and perform work in a manner that meets or exceeds the recognized workmanship standards for the industry. . B. All drawings are to be submitted for review and approval to the Owner before performing Work. . C. Heating for this project is ductless split system heat pump with zonal control to provide heating to the largest zone of the dwelling unit where the rest of unit heated with zonal electric heating, per F under ENERGY CODE NOTES. . . B. WHOLE HOUSE VENTILATION Whole House Ventilation using an ERV system with integral fans per I.R.C. M1505.4.1. Continuous whole house ventilation system shall comply with the following: ·Exhaust fans shall be ducted directly to the outside ·Exhaust fans shall be designed to limit the pressure difference to the outside ·Shall be equipped with backdraft damper or motorized damper complying with WSEC ·Shall be tested and rated in accordance with the airflow and sound rating procedures as described in section M1505.4.4.2 ·Bathroom fans with intermittent exhaust airflow rates higher than the continuous exhaust airflow rates in Table M1505.4.4(1) shall be provided with occupancy sensors or humidity sensors to automatically override the fan to the highest speed airflow rate. ·Whole house mechanical ventilation system shall be tested, balanced and verified to provide a flow rate not less than the minimum required by Section M1505.4.3 and M1505.4.4 . Testing shall be performed according to the ventilation equipment manufacturer's instruction, or by using a flow hood, flow grid, or other airflow measuring device at the mechanical ventilation fans inlet terminal, outlet terminals or grills or in the connected ventilation ducts. Where required for the building official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the tests and provided to the building officials and be posted in the dwelling unit per M1505.4.1.7 . ·The whole house ventilation system shall be controlled with manual switches, timers or other means that provide for automatic operation of the ventilation system that are readily accessible by the occupant. ·Whole house mechanical ventilation system shall be provided with the controls that enable manual override off of the system by the occupant during periods of poor air quality. Control show include permanent text or a symbol indicating their function. ·Whole house ventilation systems shall be configured to operate continuously except intermittent off controls and sizing are provided per Section M1505.4.3.2 . ·Fresh air inlets shall be screened and away from any hazardous fumes. Doors shall be undercut 1/2" min above surface of finished floor. ·Undercut door or provide transfer grill if Whole House Fan is located in Laundry/Utility Room. ·HVAC contractor shall comply with proper sizing of supply ducts, damper size, minimum ventilation rate, fan noise and all other requirements in Section M1505 of I.R.C. Continuously Operating System Per I.R.C. Table M1505.4.3 (1): The Main House, 3,357 sf 5 bedroom, fan = min 90 cfm located in Laundry Room. Square Footage Bedrooms 0-1 2-3 4-5 6-7 > 7 < 1,500 30 45 60 75 90 1,501-3,000 45 60 75 90 105 3,001-4,500 60 75 90 105 120 4,501-6,000 75 90 105 120 135 6,001-7,500 90 105 120 135 150 > 7,500 105 120 135 150 165 D. Appliances intended for installation in closets, alcoves or confined spaces shall be so listed per code, I.M.C. and Chapter 13 of I.R.C. . E. Appliances installed in garages or other areas where they may be subject to mechanical damage shall be suitably guarded against such damage by being installed behind protective barriers or by being elevated or located out of the normal path of vehicles. Equipment located in a garage and capable of igniting flammable vapors shall be installed with the pilots and burners or heating elements and switches at least 18 inches above the floor level. F. Appliances designed to be in a fixed position shall be securely fastened in place. Supports for appliances shall be designed and constructed to sustain vertical and horizontal loads within the stress limitations in the building code and I.M.C. and Chapter 13 of I.R.C. . G. Verify types, Manufacturer, and locations of all Plumbing Fixtures, Faucets with Owner prior to purchasing and / or installing. H. Vent outlet for gas appliances shall be 3' minimum away from door opening, or operable or fixed windows, and 10' minimum away from fresh air intakes per Washington State EC and I.R.C. Chapter 24. D. Per I.R.C. Section R702.3.7 Water resistant gypsum backing board shall NOT be installed over a Class I or II vapor retarder in a shower or tub compartment. Water resistant gypsum backer board shall NOT be used where there will be direct exposure to water or in areas of high humidity. Per Table R702.4.2 the use of cement backer board is allowed in these areas. Glass mat (ASTM C 1178) or fiber-reinforced gypsum panels (ASTM C 1278) are also allowed.ARCHITECTURAL NOTESA-2SHEET TITLE:PROJECT:SHEET NUMBER:STRAIGHT ARROW N 35TH ST RENTON1218 N 35th StreetRenton, WA 98056COPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" x 36"NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEET1951.0 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CLIENT: CONSULTANT: REVISIONS: DATE: JOB NUMBER: SCALE: DRAWN BY: 01 OCTOBER 2021 AM Straight Arrow Homes, LLC 12015 NE 8th Street Suite 5 Bellevue, WA 98005 AS SHOWN Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 PR21000259 B21005267 UP SMOKE DETECTOR EXHAUST FAN WITH CFM CALL-OUT BELOW SD EGRESS WINDOW MIN. 5.7 SF NET OPENING (MIN. 24" HIGH, 20" WIDE) E SAFETY GLAZINGSG CLOSETCLST. SDC COMBINED SMOKE DETECTOR & CARBON MONOXIDE ALARM HEAT DETECTORHD60' - 0"50' - 0"7' - 0"26' - 6"13' - 6" 19' - 0 1/2"8' - 3 1/2"6' - 8 1/2"11' - 5 1/2"5' - 6"7' - 3 1/2"3' - 6"3' - 6"22' - 8 1/2"7' - 7"4' - 6"9' - 0"16' - 11"9' - 0"7' - 0" 40' - 0"12' - 0"5' - 11"6' - 0"29' - 1"1' - 0" 1' - 6" 4' - 3"12' - 0"4' - 3" 2' - 3"9' - 0"2' - 3" 1' - 4" GARAGE OFFICE/ JUNIOR SUITE LIVING DINING KITCHEN UP UP 6R DN COAT 5' - 6"4' - 6" 4' - 8 1/2" BATHROOMPOWDER 2' - 1"2' - 7" COVERED PATIO 3' - 7"19' - 1 1/2"STORAGE 19' - 6 1/2"17' - 7"30" PANTRY A A-4 COV. PORCH CABINETRYCONCRETE 36" REF.30" DW13' - 6"5' - 0"1' - 0" WOOD FRAME ROOF ABOVE DECORATIVE OR STRUCTURAL BEAMS ABOVE CONCRETE 3' - 6"1/4" / FOOT SLOPEDECK EDGE ABOVE 1' - 6"20' - 1"8' - 2 1/2"28' - 8 1/2"1' - 6"2' - 6"6' - 0"10' - 11"4' - 0"5' - 3 1/2"1' - 7 1/4"5' - 0"1' - 7 1/4"2' - 6"2' - 6"6' - 7"5' - 0"3' - 6"1' - 6"6' - 0"1' - 6" 2' - 0"16' - 0"2' - 7 1/2"5' - 3"7 1/2" 2' - 0"8' - 0"2' - 0" 3' - 3 3/4"3' - 0"3 1/2"3' - 0"3 1/2"3' - 0"3 1/2"3' - 0"3' - 3 3/4"1' - 4"6' - 0"1' - 8"1' - 3"3' - 0"1' - 8"10' - 6"5' - 0"9' - 4"3' - 0"1' - 3"4' - 0"WHTANKLESS WATER HEATER 50 FACTORY BUILT FIREPLACE TO BE UL LISTED, LABELED AND INSTALLED WITH CONDITIONS OF LISTING. FACTORY BUILT FIREPLACE MUST BE TESTED IN ACCORDANCE WITH UL 127, WASHINGTON CERTIFIED GAS FIREPLACE. SEPARATE GARAGE FROM LIVING SPACE WITH * NOTE THIS SHEET. R-21 INSUL. AT WALL AND R-38 INSUL. AT CEILING BTWN. GARAGE & HEATED SPACE, TYP. * SLAB ON GRADE 1/8" SL/FT.EXHAUST DUCT OUTLETS AT 1ST FLOOR TERMINATE OUT WALL, TYP. CRAWL SPACE ACCESS, MIN OPENING OF 18" X 24", WITH 16"X8" CRAWL SPACE VENT IN DOOR 50 100 2'10X6'8 2'6x6'82'6x6'82'6x6'8 3'0x8'01'0x8'0 16'0x8'0 6'0x5'0 5'0x3'05'0x3'03'0x5'03'0x5'04'0x4'62'6x6'88'0x6'0 6'0X4'02'6x3'02'6x6'86'0x8'01'0x8'0 3'0x5'0 3'0x5'0 3'0x5'0 3'0x5'0 3' sill @ landingCLST. *SGSGSGSG SGE SDC SD MIN 36" HIGH GUARDRAIL, TYP. SG B A-4 19' - 6"1/4" / FT. SLOPE16"x8" CRAWL SPACE VENT, TYP. 1-HOUR RATED WALL ASSEMBLY WITHIN 2-5' FROM PROPERTY LINE 1-HOUR RATED WALL ASSEMBLY WITHIN 2-5' FROM PROPERTY LINEPRE-CAST CONCRETE STAIR TREADS, WOOD STRINGERS PER STRUCTURAL, TYP. 16"x8" CRAWL SPACE VENT, TYP. 6' - 5"3' - 10" WALL ABOVE A-8 10 A-8 9 A-9 3 A-9 7 A-8 11 HD 5'0x4'0 SGA-8 10 TYP.3' - 0"DN 14' - 4 1/2"19' - 2 1/2" 12' - 7 1/2"11' - 5 1/2"5' - 6"WD19' - 6"9' - 3"9' - 0"2' - 3"1' - 6"MASTER BEDROOM COVERED DECK BEDROOM 38' - 0"13' - 11"5' - 0"7' - 3 1/2"BATHR. W.I.C. MASTER BATHROOM LINEN 2' - 1"6' - 8"7' - 0"5' - 6"5' - 8 1/2" 13' - 3 1/2" 5' - 0"8' - 3 1/2"11' - 8 1/4"2' - 1"2' - 1"11' - 8 1/4"4' - 6" 3' - 0"4' - 6" LINEN BEDROOM 2 CLOSET CLOSET BEDROOM 1 LAUNDRY CLOSET COMMON SPACE/ DEN3' - 6"6' - 0"10' - 2"DN 3' - 1"6' - 4"5' - 0"4' - 0" A A-4 60" TUB 4'X6' SHOWER 5' - 0"7' - 7 1/2"10' - 1 1/2"3' - 6"2' - 1"1' - 9" WALL BELOW 3' - 6"5' - 0"6' - 7"2' - 6"2' - 6"1' - 7 1/4"5' - 0"1' - 7 1/4"4' - 3 1/2"5' - 0"10' - 11"5' - 0"3' - 6"1' - 6"20' - 1"8' - 2 1/2"28' - 8 1/2"58' - 6"1' - 6"4' - 0"3' - 6"8' - 0"3' - 6" 19' - 6"20' - 6" 1' - 9"5' - 0"12' - 9"3' - 6"8' - 0"16' - 10"4' - 0"1' - 8"40' - 0" 1' - 5"5' - 0"2' - 10"1' - 6"6' - 0"1' - 6"11' - 0"34' - 0"1' - 5"5' - 0"2' - 7"9' - 0"2' - 0"9' - 0"8' - 6" E 2'8x6'8 2'6x6'8 2'4x6'8 2'4x6'85'0x3'05'0x5'0 5'0x2'08'0x5'0 8'0x4'62'6x6'8 5'0x6'82'6x6'82'6x6'82'6x6'82'8x6'85'0x6'8 5'0x6'8 2'6x6'8 2'10x6'85'0x3'0 5'0x5'02'4x6'8 4'0x4'6 4'0x3'03'0x7'0 9'0x7'0 SG SG2'6x3'0SG SG SGSGE EE 50 90 50 50 CONTINOUS WHOLE HOUSE FAN EXHAUST DUCT OUTLETS AT 2ND FLOOR TERMINATE OUT ROOF, TYP. SDC SD SD SD SD MIN 22"X30" ATTIC ACCESS W/ R-38 INSULATION PER DETAILS MIN 36" HIGH GUARDRAIL, TYP. ROOF ABOVE ROOF ABOVE 1' - 4" 6'0x5'03' - 5"5'0x4'0B A-4 1-HOUR RATED WALL ASSEMBLY WITHIN 2-5' FROM PROPERTY LINE 1/4" / FT. SLOPE5" FASCIA GUTTER, TYP. FACE-MOUNTED METAL GUARDRAIL PER STRUCTURAL, MIN 36" ABOVE FFE, TYP. MEMBRANE DECKING PER DETAILS, SLOPE 1/4"/ FT. , TYP. 1-HOUR RATED EAVE REQ'D WHEN LESS THAN 5' FROM PROPERTY LINE, TYP. 7' - 4"3' - 10" 5" DN A-9 5 A-10 2 CODE COMPLIANT PREFAB METAL SPIRAL STAIRS BY OTHERS, INSTALL PER MANUFACTURER, SEE NOTES ON SHEET A-43 1/2" / 1'-0"2'X4' SKYLIGHTS 5'0x2'0MIN R-38 INSULATION REQUIRED @ ROOF A-8 7 DATE: PROJECT NO: SCALE: DRAWN BY: 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CB ANDERSON ARCHITECTS SHEET TITLEREVISIONS: PLLC.NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEETCOPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" X 36".CLIENT: CONSULTANT: Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 Straight Arrow Homes, LLC 12015 NE 8th Street, Suite 5 Bellevue, WA 98005 PR21000259 B21005267 1/4" = 1'-0" A-3 AMSTRAIGHT ARROW N 35TH ST RENTONFLOOR PLANS1951.0 01 OCTOBER 20211218 N 35th StreetRenton, WA 98056LEGEND NORTH SCALE: 1/4" = 1'-0" 1ST FLOOR SCALE: 1/4" = 1'-0" 2ND FLOOR NORTH WHOLE HOUSE FAN VENTILATION CONTINUOUS WHOLE HOUSE FAN MIN 90 CFM SEE SHEET A-2 VENTILATION & AIR QUALITY NOTES GUARDRAIL NOTE: - GUARDS DESIGNED TO RESIST A 200 LB CONCENTRATED LOAD ON THE TOP RAIL AND 50 PSF ON ALL GUARDRAIL INFILL COMPONENTS, TYP. - PROVIDE GUARD RAIL IF THERE IS MORE THAN 30" LEVEL CHANGE, GUARD RAIL HEIGHT TO BE 36" MIN. W/ LESS THAN 4" BTWN BALUSTERS, TYP. EXHAUST DUCT OUTLETS MUST TERMINATE NOT LESS THAN 3' FROM OPENINGS INTO BUILDINGS, TYP. SMOKE ALARMS: - SMOKE ALARMS SHALL NOT LOCATED WITHIN 3' OF A DOOR OR OPENING OF A BATHROOM OR SHOWER ROOM. - IONIZATION SMOKE ALARMS SHALL NOT BE INSTALLED WITHIN 20 FEET OF A PERMANENT INSTALLED COOKING APPLIANCE. THE DISTANCE IS CUT IN HALF TO 10 FEET FOR IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH. - PHOTOELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED WITHIN 6 FEET OF A PERMANENT INSTALLED COOKING APPLIANCE. ENERGY CODE NOTES: PER ENERGY CREDIT OPTION 5.5: ELECTRIC HEAT PUMP WATER HEATER MEETING THE STANDARDS FOR TIER III OF NEEA'S ADVANCED WATER HEATING SPECIFICATION CRAWL SPACE VENT CALCULATION: 1500 SF / 300 = 5 SF X 144 IN. = 720 SQ IN / 72.5 SQ. IN. (16"X8" VENT) = 9.93 PROPOSED: (10) 16"X8" VENTS GARAGE AREA SEPARATION NOTES 1. GARAGE SHALL BE SEPARATED FROM RESIDENCE BY 1/2" TYPE 'X' GWB @ WALLS. 2. GARAGE BELOW HABITABLE ROOM SHALL BE SEPARATED BY (2 LAYERS) 5/8" TYPE 'X' GWB FOR TJI FRAMING, (1 LAYER) 5/8" TYPE 'X' GWB FOR SOLID LUMBER. 3. STRUCTURE SUPPORTING FLOOR-CEILING ASSEMBLY SHALL BE PROTECTED BY 1/2" TYP 'X' GWB. 4. 20 MINUTE OR SELF-CLOSING, TIGHT FITTING, 1 3/8" SOLID CORE DOOR, TYP. AT GARAGE TO LIVING SPACE. NOTES: R303.7 INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS OF NOT LESS THAN 1 FOOT- CANDLE (11 LUX) AS MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. R303.8 EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. R303.7.1 WHERE LIGHTING OUTLETS ARE INSTALLED IN INTERIOR STAIRWAYS, THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHTING OUTLET WHERE THE STAIRWAY HAS SIX OR MORE RISERS. THE ILLUMINATION OF EXTERIOR STAIRWAYS SHALL BE CONTROLLED FROM INSIDE THE DWELLING UNIT. STAIR NOTE: 7-3/4" MAX. RISER HEIGHT AND MIN. 10" TREAD DEPTH CONTINUOUS 1.5" DIA. HANDRAIL ON ONE SIDE HANDRAIL NOTE: 1) LOCATION AT 34-38 INCHES ABOVE THE STAIR NOSING. 2) GRASP DIMENSION BETWEEN 1-1/4-2 INCHES. 3) PROVIDE CONTINUOUS HANDRAIL OR TERMINATE AT NEWEL POSTS OR SAFETY TERMINAL. * NOTES: R314.2.3 A HEAT DETECTOR OR HEAT ALARM RATED FOR THE AMBIENT OUTDOOR TEMPERATURES AND HUMIDITY SHALL BE INSTALLED IN NEW GARAGES THAT ARE ATTACHED TO OR LOCATED UNDER NEW AND EXISTING DWELLINGS. HEAT DETECTORS AND HEAT ALARMS SHALL BE INSTALLED IN A CENTRAL LOCATION AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. DN 4" / 1'-0"ROOFTOP DECK 19' - 0 1/2"44' - 1"A A-4 CONTRACTOR TO RUN PLUMBING & DRAIN FOR FUTURE ROOF DECK KITCHEN 1' - 7"1' - 0"2' - 0"2' - 6"1' - 7" SOLAR READY ZONE 304 SF NO ROOF PENETRATION IS ALLOWED IN SOLAR READY ZONES, TYP. 13' - 6"22' - 6"B A-4 1/4" / FOOT SLOPE 1/4" / FOOT SLOPE TRANSPARENT FASCIA-MOUNT CABLE RAILING, MIN 3' ABOVE FINISHED FLOOR, TYP. UNVENTED ROOF ASSEMBLY PER DETAILS PROVIDE PROPER CRICKETS, ENSURE WARRANTED INSTALLATION TO DIRECT THE WATER TO THE PROPOSED SCUPPERS, TYP. SCUPPER W/ OVER FLOW, TYP. MIN 36" HIGH GUARDRAIL, TYP. 5" FASCIA GUTTER, TYP. PROVIDE CONTINUOUS SNOW & ICE SHIELD FLASHING AT ALL CRICKETS & SIDE WALLS, OVERLAP MIN 8", TYP. CROSSHATCH INDICATES 1-HOUR RATED EAVES WHEN LESS THAN 5' FROM PROPERTY LINE, TYP. (EAST SIDE EAVES ONLY) A-8 4 A-8 2 A-8 2 A-8 1 PATIO ROOF BELOW 1ST FLOOR 166' - 8" 2ND FLOOR 176' - 9 3/4" AVG GRADE 164' - 3 3/8" MAX RIDGE HT 194' - 3 3/8" MAX PLATE HT 188' - 3 3/8" PLATE HT 184' - 9 3/4" ROOF DECK 186' - 3" UNVENTED, VAULTED MONO TRUSS ROOF W/ ENERGY HEEL PER STRUCTURAL TRANSPARENT FASCIA-MOUNT CABLE RAILING, MIN 3' ABOVE FINISHED FLOOR, TYP.8' - 0 1/4"1' - 5 1/4"PLATE HT. 8' - 0"10' - 1 3/4"6' - 0"24' - 0"4" / 1'-0"1'-6" MIN9' standard studs9' - 1 1/4"CRAWLSPACE 2" / 1'-0" 11 7/8" TJI FLOOR FRAMING PER STRUCTURAL UNVENTED ROOF DECK ASSEMBLY W/ PRE-FAB 16" TOP CHORD SLOPED TRUSSES PER STRUCTURAL 8" 1' - 7" B A-4 MIN R-38 INSULATION @ FLOOR ABOVE NON-CONDITIONED AREA, TYP.LOWER PLATE HT.20' - 6 1/2"UPPER PLATE HT.24' - 1 3/4"36" MIN.MIN HEADROOM, CLR, TYP.6' - 8"MIN 36" HIGH GUARDRAIL, TYP. GARAGE MASTER BEDROOM 1/4" / FOOT SLOPE 8' - 0"PROVIDE 5/8 TYPE "X" DRYWALL AT CEILING BELOW THE HEATED AREA, R-38 INSULATION IS REQUIRED, TYP. PROVIDE 1/2 TYPE "X" DRYWALL AT WALLS BETWEEN THE GARAGE & HEATED AREA, R-21 INSULATION IS REQUIRED, TYP.3' - 3 1/4"FOOTING & FOUNDATION PER STRUCTURAL STAIRS- 11" TREAD 17 RISERS @ 7.16" VERIFY THE HEIGHTS IN THE FIELD A-8 4 A-8 11 A-8 9 A-8 1SIM. LOWER WALL PLATE HT: 20'-6 1/2" UPPER WALL PLATE HT: 24'-1 3/4" AVERAGE WALL PLATE HT: 22.3' --> OKHEEL HT.4' - 6"SIM. 1ST FLOOR 166' - 8" 2ND FLOOR 176' - 9 3/4" AVG GRADE 164' - 3 3/8" MAX RIDGE HT 194' - 3 3/8" MAX PLATE HT 188' - 3 3/8" PLATE HT 184' - 9 3/4" ROOF DECK 186' - 3" A A-4 1/8" / 1'-0" MASTER BEDROOM W.I.C. MASTER BATHROOM LIVING GARAGE PORCH DECK ROOFTOP DECK R-38 INSULATION R-38 INSULATION R-21 INSULATIONR-21 INSULATION R-10 INSULATION AT HEADERS, TYP. FACE-MOUNT METAL GUARDRAIL TO BE MIN 36" ABOVE FINISHED FLOOR ELEVATION, TYP. PRE-CAST CONCRETE STAIR TREADS, WOOD STRINGERS PER STRUCTURAL, TYP. MEMBRANE DECKING PER DETAILS, SLOPE 1/4"/ FT. 2x12 WOOD FRAMING PER STRUCTURAL TOTAL OF R-38 INSULATION REQUIRED 11 7/8" TJI FLOOR FRAMING PER STRUCTURAL A-8 2 A-9 6 CRAWLSPACE DRIVEWAY BEYOND DATE: PROJECT NO: SCALE: DRAWN BY: 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CB ANDERSON ARCHITECTS SHEET TITLEREVISIONS: PLLC.NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEETCOPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" X 36".CLIENT: CONSULTANT: Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 Straight Arrow Homes, LLC 12015 NE 8th Street, Suite 5 Bellevue, WA 98005 PR21000259 B21005267 1/4" = 1'-0" A-4 AMSTRAIGHT ARROW N 35TH ST RENTONROOF PLAN & SECTIONS1951.0 01 OCTOBER 20211218 N 35th StreetRenton, WA 98056NORTH ROOF INSTALLATION NOTE PER SBC 1507.2.2 FOR ASPHALT SHINGLE INSTALLATIONS BETWEEN 2:12 AND 4:12 SLOPES, PROVIDE (2) LAYERS UNDERLAYMENT MEETING AND CONFORMING TO CODE STANDARDS. FASTENERS & FLASHING TO BE PER SBC 1507. SOLAR-READY NOTES: A - SEE STRUCTURAL FOR ROOF DESIGN, WHICH INCLUDES A MINIMUM OF 300 SF AREA RESERVED FOR PHOTOVOLTAIC PANELS WEIGHING A MINIMUM OF 4 PSF. B - SEE ROOF PLAN FOR BOUNDARIES. PERMANENTLY INSTALLED OBJECTS ADJACENT TO THE SOLAR-READY ZONE SHALL BE LOCATED SO THAT THEY DO NOT CAST SHADOWS ON THE SOLAR-READY ZONE WHEN THE SUN IS DIRECTLY EAST, WEST, OR SOUTH OF THE SOLAR-READY ZONE AT 45 DEGREES ABOVE THE HORIZON. C - "THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW INSTALLATION OF A DUAL POLE CIRCUIT BREAKER FOR FUTURE SOLAR ELECTRIC INSTALLATION AND SHALL BE LABELED 'FOR FUTURE SOLAR ELECTRIC.'" D - "A PERMANENT CERTIFICATE, INDICATING THE BOUNDARIES AND STRUCTURAL PROVISIONS OF THE SOLAR-READY ZONE, SHALL BE POSTED NEAR THE ELECTRICAL DISTRIBUTION PANEL, WATER HEATER OF OTHER CONSPICUOUS LOCATION." TYPICAL ABOVE GRADE EXTERIOR WALL - SIDING PER ELEVATIONS - WATER RESISTANT BARRIER - SHEATHING PER STRUCTURAL - FRAMING PER STRUCTURAL - R-21 BATT INSULATION - 1/2" GWB - VAPOR BARRIER - PRIMER AND PAINT WINDOW NOTE 1. WINDOWS ARE TO BE NFRC CERTIFIED. 2. MAXIMUM U-VALUE ALLOWED OF 0.28 FOR THIS PROJECT PER ENERGY CREDITS SHEET A-2.0. ENERGY NOTE: ALL EXTERIOR DOOR & WINDOW HEADERS SHALL BE INSULATED W/ A MINIMUM OF R-10 INSULATION. TYPICAL NON-RATED UNVENTED MAIN ROOF - COMPOSITION ROOFING - 2 LAYERS OF 30# ROOF UNDERLAYMENT - SHEATHING & NAILING PER STRUCTURAL - VAULTED MONO TRUSS ROOF W/ ENERGY HEEL PER STRUCTURAL - UNVENTED ROOF PER IRC 806.5.5.1.3 WITH CLOSE CELL SPRAY-IN FOAM INSULATION W/ 2" SPRAY FOAM AT R-14 (HEATLOK ECO PER ICC-ES REPORT) APPLIED DIRECTLY UNDER ROOF SHEATHING, & 10 1/4" BATT INSULATION @ R- 38, TOTAL OF R-52 INSULATION (MIN R-49 REQUIRED) - 1/2" GWB - PRIMAR AND PAINT (NO VAPOR RETARDER ALLOWED) (SEE 8/A-8 REGARDING SPRAY APPLIED INSULATION) TYPICAL NON-RATED UNVENTED ROOP TOP DECK - WARRENTED ELASTROMERIC WATERPROOFING COATING (POLYUREA OR APPROVED EQ.) - (2) LAYERS PLYWOOD SHEATHING PER STRUCTURAL - ROOF TRUSSES PER STRUCTURAL W/ TOP CHORD SLOPED @ 1/4" PER FT. - UNVENTED ROOF PER IRC 806.5.5.1.3 WITH CLOSE CELL SPRAY-IN FOAM INSULATION, W/ 2" SPRAY FOAM AT R-14 (HEATLOK ECO PER ICC-ES REPORT) & 8" BATT INSULATION @ R-25, TOTAL OF R-39 INSULATION (MIN R- 38 REQUIRED) - 1/2" GWB - PRIMAR AND PAINT (NO VAPOR RETARDER ALLOWED) (SEE 8/A-8 REGARDING SPRAY APPLIED INSULATION) SCALE: 1/4" = 1'-0" ROOF DECK SCALE: 1/4" = 1'-0" SECTION A SCALE: 1/4" = 1'-0" SECTION B SPIRAL STAIRWAY NOTES: PER IRC R311.7.10.1. THE CLEAR WIDTH AT AND BELOW THE HANDRAILS AT SPIRAL STAIRWAYS SHALL NOT BE LESS THAN 26" AND THE WALKLINE RADIUS SHALL NOT BE GREATER THAN 24 1/2". EACH TREAD SHALL HAVE A DEPTH OF NOT LESS THAN 6 3/4 INCHES AT THE WALKLINE. TREADS SHALL BE IDENTICAL, AND THE RISE SHALL BE NOT MORE THAN 9 1/2". HEADROOM SHALL BE NOT LESS THAN 6'-6". 1ST FLOOR 166' - 8" 2ND FLOOR 176' - 9 3/4"8' - 0"10' - 1 3/4"PLATE HT 184' - 9 3/4" ROOF DECK 186' - 3" 5'0x3'0 5'0x3'0 4'0x4'6 6'0X4'02'6x3'0 5'0x2'0 2'6x3'0 SG SG SG 5'0x4'0 E 16"x8" CRAWL SPACE VENT, TYP.5' - 0"7' - 0"4' - 0"3' - 0"5' - 0"8' - 0"5' - 0"5' - 0"3' - 6"4' - 0"EXISTING GRADE 3' - 0"5'0x4'0 18' - 1 3/4"8' - 2 1/2" WALL AREA: 18.1' x 8.2' = 148.4 SF PER IRC R302.1(1), 25% MAX OPENING IN WALL ALLOWED WHEN WALL IS 3-5' TO PROPERTY LINE. MAX ALLOWED: 148.4 X 0.25 = 37.1 SF PROPOSED OPENING AREA: (5' x 4') + (5' x 3') = 35 SF --> OK 5'0x2'0 R 3' - 0"R 3' - 0"R 3' - 0" 1ST FLOOR 166' - 8" 2ND FLOOR 176' - 9 3/4" PLATE HT 184' - 9 3/4"10' - 1 3/4"8' - 0"ROOF DECK 186' - 3" 4 " / 1 '-0 " 8'0x6'0 8'0x5'0 5'0x3'04'0x4'6 3'0x5'0 3'0x5'0 3'0x5'0 3'0x5'0 SG E 1' - 10"TRANSPARENT FASCIA-MOUNT CABLE RAILING, MIN 3' ABOVE FINISHED FLOOR, TYP.8' - 0"3' - 0"3' - 6"4' - 0"2' - 0"3' - 0"EXISTING GRADE 1ST FLOOR 166' - 8" 2ND FLOOR 176' - 9 3/4" AVG GRADE 164' - 3 3/8" MAX RIDGE HT 194' - 3 3/8"8' - 0 1/4"1' - 5 1/4"8' - 0"10' - 1 3/4"MAX PLATE HT 188' - 3 3/8"6' - 0"24' - 0"PLATE HT 184' - 9 3/4" ROOF DECK 186' - 3" 3 1 /2 " / 1 '-0" 5'0x3'0 3'0x5'0 3'0x5'0 8'0x4'6 6'0x8'0 5'0x5'0 4'0x3'0 3'0x7'0 SG SG SG SG CRAWL SPACE ACCESS, MIN OPENING OF 18" X 24", WITH 16"X8" CRAWL SPACE VENT IN DOOR8' - 0"3' - 0"7' - 0"4' - 0"2' - 6"5' - 0"8' - 0"3' - 0"PROPOSED DOWNSPOUT TO THE APPROVED POINT OF DISCHARGE, TYP. EXISTING GRADE R 3' - 0" R 3' - 0" 1ST FLOOR 166' - 8" 2ND FLOOR 176' - 9 3/4" AVG GRADE 164' - 3 3/8" MAX RIDGE HT 194' - 3 3/8" MAX PLATE HT 188' - 3 3/8"6' - 0"24' - 0"PLATE HT 184' - 9 3/4"9' - 5 1/2"8' - 0"10' - 1 3/4"ROOF DECK 186' - 3" 4" / 1'-0" 3 1 /2 " / 1'-0 " 3'0x8'01'0x8'0 16'0x8'0 6'0x5'0 5'0x5'09'0x7'0 1'0x8'0 EXISTING GRADE PROPOSED GRADE SG SG SG SG SG E E 6'0x5'0 E 3' - 0"8' - 0"3' - 0"8' - 0"3' - 0"1' - 6" METAL SIDING HARDIE PANEL SIDING, TYP. HARDIE LAP SIDING, TYP.36" MIN., TYP.36" MIN., TYP.COMPOSITE SHINGLE ROOF OVER (2) LAYERS 30# BLDG PAPER, TYP. WINDOWS TO HAVE U-FACTOR 0.28 FIELD VERIFY THIS HIGHER STANDARD 1 DATE: PROJECT NO: SCALE: DRAWN BY: 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CB ANDERSON ARCHITECTS SHEET TITLEREVISIONS: PLLC.NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEETCOPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" X 36".CLIENT: CONSULTANT: Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 Straight Arrow Homes, LLC 12015 NE 8th Street, Suite 5 Bellevue, WA 98005 PR21000259 B21005267 1/4" = 1'-0" A-5 AMSTRAIGHT ARROW N 35TH ST RENTONELEVATIONS1951.0 01 OCTOBER 20211218 N 35th StreetRenton, WA 98056SCALE: 1/4" = 1'-0" EAST ELEVATION SCALE: 1/4" = 1'-0" NORTH ELEVATION SCALE: 1/4" = 1'-0" WEST ELEVATION SCALE: 1/4" = 1'-0" SOUTH ELEVATION ROOF INSTALLATION NOTE PER IBC 1507.2.2 FOR ASPHALT SHINGLE INSTALLATIONS BETWEEN 2:12 AND 4:12 SLOPES, PROVIDE (2) LAYERS UNDERLAYMENT MEETING AND CONFORMING TO CODE STANDARDS. FASTENERS & FLASHING TO BE PER SBC 1507. E EGRESS WINDOW MIN. 5.7 SF NET OPENING (MIN. 24" HIGH, 20" WIDE) SG SAFETY GLAZING LEGEND SIDING MATERIAL AND COLORS: MANUFACTURED SIDING TO BE INSTALLED PER INDUSTRY BEST PRACTICE AND MANUFACTURER’S RECOMMENDATIONS. FLATNESS TOLERANCE TO BE < 1/8” OVER 10’. LAP SIDING · 5/16” SMOOTH FIBER CEMENT LAP SIDING · MANUFACTURER: JAMES HARDIE · 4” EXPOSURE · PAINT: BENJAMIN MOORE CHELSEA GRAY HC-168 PANEL SIDING W/ REVEALS · 5/16” SMOOTH FIBER CEMENT PANELS · MANUFACTURER: JAMES HARDIE · PAINT: BENJAMIN MOORE BLACK IRON 2120-20 · PANEL TRIM BY FRY REGLET, OR APPROVED EQUAL PER OWNER PLATE HEIGHT NOTES: MAX HEIGHT FROM AVERAGE GRADE LEVEL (SEE CALCULATIONS SHEET A-1.0) TO PLATE HEIGHT IS 24'-0" PLUS 6' ADDITIONAL FOR A PITCHED ROOF W/ MIN 4:12 SLOPE. CONTRACTOR IS RESPONSIBLE TO MONITOR CONSTRUCTION & COMPLETION TO ENSURE COMPLIANCE. ELEVATION NOTES: 1. PROVIDE FLASHING AT ALL DOORS, WINDOW AND HORIZONTAL TRIM TRANSITIONS, TYP. FLASH AT ALL ROOF VALLEY CONDITIONS, ALL WALL TO ROOF AND WALL TO DECK CONDITIONS, DECK WATERPROOFING TO BE WARRANTED, TYP. 2. INSTALL MANUFACTURED SIDING PER MANUFACTURER'S GUIDELINES AND CEDAR SIDING PER WESTERN RED CEDAR LUMBER ASSOCIATION GUIDELINES, TYP. 3. GUTTERS & DOWNSPOUTS TO LEAD TO TIGHTLINE CONNECTION TO CITY APPROVED DRAINAGE SYSTEM CASEMENT OR AWNING WINDOWS USED FOR EGRESS MUST INCLUDE HARDWARE THAT ALLOWS THE WINDOW TO OPEN A MINIMUM OF 90 DEGREES AND PROVIDES FULL WIDTH CLEARANCE IN FULLY OPEN POSITION. GUARDRAIL NOTE: - GUARDS DESIGNED TO RESIST A 200 LB CONCENTRATED LOAD ON THE TOP RAIL AND 50 PSF ON ALL GUARDRAIL INFILL COMPONENTS, TYP. - PROVIDE GUARD RAIL IF THERE IS MORE THAN 30" LEVEL CHANGE, GUARD RAIL HEIGHT TO BE 36" MIN. W/ LESS THAN 4" BTWN BALUSTERS, TYP. EXHAUST DUCT OUTLETS MUST TERMINATE NOT LESS THAN 3' FROM OPENINGS INTO BUILDINGS, TYP. METAL SIDING · 24 GAUGE STEEL, FLAT SHEET · MANUFACTURER: THE BRYER COMPANY · PAINT: NIGHT SKY, NATURAL FX COATING SOFFIT · CEDAR T&G W/ CLEAR COAT FASCIA · PAINT: BENJAMIN MOORE BLACK IRON 2120-20 Notes: - Follow all installation instructions per manufactures. 1 27 DECEMBER 2021 DATE: PROJECT NO: SCALE: DRAWN BY: 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CB ANDERSON ARCHITECTS SHEET TITLEREVISIONS: PLLC.NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEETCOPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" X 36".CLIENT: CONSULTANT: Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 Straight Arrow Homes, LLC 12015 NE 8th Street, Suite 5 Bellevue, WA 98005 PR21000259 B21005267 A-6 AMSTRAIGHT ARROW N 35TH ST RENTON3D VIEWS1951.0 01 OCTOBER 20211218 N 35th StreetRenton, WA 980563D View 3 3D View 1 3D View 2 3D View 4 MINISPLIT HEAT PUMP:DAIKIN 4MXS36RMVJUDAIKIN 5MXS48TVJUWATER HEATER:RUUD PROH80 T2 RU310UM11ENERGY WORKSHEETS A-7SHEET TITLE: PROJECT:SHEET NUMBER:STRAIGHT ARROW N 35TH ST RENTON 1218 N 35th Street Renton, WA 98056 COPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" x 36"NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEET 1951.07209 Greenwood Avenue NorthSeattle, Washington 98103206-782-2911Fax 782-5624CLIENT:CONSULTANT:REVISIONS:DATE: JOB NUMBER: SCALE:DRAWN BY:01 OCTOBER 2021AMStraight Arrow Homes, LLC12015 NE 8th Street Suite 5Bellevue, WA 98005AS SHOWNEquilibria StructuralEngineering9999 Harbour Place, Suite 107Mukilteo, WA 98275360-386-9476PR21000259B2100526727 DECEMBER 20211 5 DOWNSPOUT DRAIN GUARD 3X4 OR 2X3 GUTTERDRAIN GUARD DOWNSPOUT PROTECTOR W/ REMOVABLE SCREENED LEAF CATCHER BY www.bestdownspoutguard.com OR EQUAL SCALE: 1"=1'-0" 3 NOTE: PER I.R.C. SECTION R807 1. ATTIC ACCESS REQUIRED TO AREA THAT EXCEEDS 30 SF AND HAS A VERTICAL HEIGHT OF 30" OR MORE 2. ROUGH FRAMED OPENING MINIMUM 22"X30", 30" UNOBSTRUCTED HEADROOM, AND ATTIC ACCESS SHALL BE LOCATED IN A HALLWAY OR ACCESSIBLE LOCATION. FRAMING AND INSULATION PER PLANS & SECTIONS 2X12 FRAMING TO RESTRAIN INSULATION PLYWOOD ATTIC ACCESS DOOR & FRAME WITH RIGID INSULATION 1X2 TRIM AT ATTIC ACCESS OPENING WEATHER STRIPPING, TYP. RUBBER GASKET PRE-MANUFACTURED ATTIC ACCESS DOOR: BATTIC DOOR ENERGY (www.batticdoor.com), MODEL 22X30-R42 1/2" GWB SCALE: 1"=1'-0" ATTIC ACCESS ROOF DECK SCUPPER4 SHEAR WALL PER PLAN & SCHEDULE R-21 INSUL, TYP. 4" DIA PERF SMOOTH WALL FTG DRAIN SLOPED TO APPROVED DRAINAGE SOURCE SEE STRUCTURAL DETAIL FOR REINFORCING R-38 INSUL, TYP. TIGHT-LINE STORM DRAIN TO APPROVED DRAINAGE SOURCE, TYP. NOTE:PER SRC CRAWL SPACE VENTILATION SHALL BE 1 SF PER 300 SF OF UNDER FLOOR SPACE, AND ONLY 1 SIDE OF BUILDING ALLOWED TO HAVE NO VENTILATION. SCALE: 1"=1'-0"9 FOUNDATION W/ VENTING 20" W x 12" D x 12" H VENT WELL BY WINDOWWELLCOVERS.COM OR EQUAL.18" MIN.18" MIN.CRAWL SPACE NORWESCO DLX 8 PLASTIC FOUNDATION VENT 16"x8"x 6", OR EQ. 72.5 SQ. IN. NFVA8" MIN6 MIL. VAPOR BARRIER EXTEND UP SIDES 8", TYP. FLOOR FRAMING PER STRUCTURAL, TYP. PROVIDE BUILDING PAPER BETWEEN FOUNDATION WALL & FLOOR JOISTS, TYP.TIGHT-LINE STORM DRAIN TO APPROVED DRAINAGE SOURCE, TYP. 4" CONC. S.O.G. OVER GRANULAR FILL PER STRUCTURAL (NO INSULATION AT GARAGE)8"MIN.SCALE: 1"=1'-0" GARAGE SLAB ON GRADE PRESSURE TREATED PLATE (OR SILL GUARD) & ANCHOR BOLTS W/ PLATE WASHER PER STRUCTURAL AND SHEAR WALL SCHEDULE, TYP. SHEAR WALL PER STRUC. PLANS & SCHEDULES TYP. NON- RATED EXT. WALL SIDING PER ELEVATIONS OVER RAIN SCREEN PER BUILDING ENCLOSURE DETAILS OVER WATER RESISTANT BARRIER OVER 1/2" SHEATHING PER STRUCTURAL OVER 2x6 STUDS @ 16" O.C. 1/2" (NO INSUL. AT GARAGE) G.W.B. AT INTERIOR SIDE REINFORCING AND DIMENSIONS PER STRUCTURAL4" DIA PERFORATED SMOOTH WALL FTG DRAIN SLOPED TO APPROVED DRAINAGE SOURCE 11SCALE: 1"=1'-0"10 FOUNDATION AT FRONT PORCH SEE STRUCTURAL DETAIL FOR REINFORCING 6 MIL. VAPOR BARRIER EXTEND UP SIDES 8", TYP. CRAWL SPACE SILL PLATE PER STRUCTURAL OVER SILL-GUARD, ANCHOR BOLTS & PLATE WASHERS PER STRUCTURAL R-38 INSUL, TYP. THRESHOLD SET IN CONTINUOUS BED OF WATERPROOFING CAULKING COMPATIBLE W/ FLASHING SYSTEM OVER 'L" SHAPED 26 GAUGE BONDERIZED SHEET METAL FLASHING PER WESTCOAT WATERPROOF MEMBRANE VERIFY THRESHOLD WITH OWNER FLEXIBLE FLASHING, TYP. JOIST HANGER PER STRUCTURAL 18" MIN18" MINPROVIDE BUILDING PAPER BETWEEN FOUNDATION WALL & FLOOR JOISTS, TYP. SCALE: 1"=1'-0"2 ROOF EAVE @ SIDE SECTION FRAMING PER STRUCTURAL FLASHING OVER 1x6 COMPOSITE FIBER TRIM SHEAR WALL PER SCHEDULE CEDAR SOFFIT PER OWNER, ALIGN SOFFITS AROUND ROOF, PROVIDE PERIODIC VENTS IN NON-RATED SOFFITS 2X BLOCKING PER STRUCTURAL PER ELEV. TYP. NON-RATED EXTERIOR WALL TYP. NON- RATED EXT. WALL ·SIDING PER ELEVATIONS ·RAIN SCREEN & WEATHER RESISTANT BARRIER PER BUILDING ENCLOSURE DETAILS ON SHEETS A-10 & 11 ·1/2" SHEATHING PER STRUCTURAL ·2X6 STUDS W/ R-21 INSULATION ·1/2" G.W.B. AT INTERIOR WITH VAPOR BARRIER PRIMER SCALE: 1"=1'-0" FIRE PLACE BAY_ 1-HOUR RATED6 FLASHING PER 2/A-10 FLASHING OVER 1X4 OVER 2X10 CEMENT BOARD TRIM FLOOR FRAMING PER STRUCTURAL W/ R-38 INSULATION R-21 INSULATION R-49 INSULATION PER PLAN SRC R302.1 1/HR FIRE RATING WITHIN 5' OF PROPERTY LINE USING TYPE 'X' 5/8" GWB ALL SIDES OF WALLS AND INTERIOR AND EXTERIOR FOR SYMMETRICAL ASSEMBLY TYPE 'X' 5/8" GWB FOR 1-HR FIRE RATING TYPE 'X' 5/8" GWB FOR 1-HR FIRE RATING 36" MIN ABOVE DECK2'-0"VERIFY PER ELEV2 LAYERS 3/4" PLYWOOD DECKING WARRANTED ELASTOMERIC SKIN OVER (2) LAYERS 3/4" PLYWD DECKING THROUGH WALL DRAIN TO BE FULLY FLASHED WATERPROOFED AND WARRANTED INSTALLATION, DRAIN TO OPEN TOP COLLECTOR BOX AND DOWNSPOUT WITH SCREEN 1/4"/ FT. SLOPE FLANGED METAL SCUPPER INSERT WITH COLLECTOR BOX: 4" DEEP, 8" WIDE AND 6" HIGH, TYP212"CONTINUOUS SLOPED BLOCKING & METAL FLASHING WITH DRIPS METAL RAILING, CONTINUOUS 2 14" x 114" TOP RAIL, 112" SQUARE POSTS WITH 3/16" INTERMEDIATE STAINLESS STEEL CABLE RAILING, SPACED EVENLY, LESS THAN 4" SPACE IN BETWEEN UNVENTED ROOF DECK ASSEMBLY W/ PRE-FAB TOP CHORD SLOPED TRUSSES PER STRUCTURAL FASTENERS WITH NEOPRENE GASKETS, SET BASE PLATE IN SEALANT OVER FLASHING, TYP. 2"2"MAX1"CONTINUOUS CANT STRIP BEYOND, TYP KERF 2X TOP CAP TO RECEIVE STANCHION, FILL GAP WITH SEALANT, TYPCONTINUOUS 2" VENT STRIP BEHIND FLASHING DOWNLEG 5"CONTINUOUS SEALANT & BACKER ROD AT SCUPPER PERIMETER & FLANGES BALLOON FRAMED PARAPET (SEE STRUCT.) W/ NON CONT. BLOCKING FRAMIG SCUPPER OPENING, TYP. SCALE: 1"=1'-0" SPRAY APPLIED FOAM INSULATION *SPRAY-APPLIED FOAM INSULATION The roof insulation for an un-vented roof assembly shall be a spray-applied foam insulation. The un-vented roof assembly shall comply with 2015 IRC R806.5. 1. Un-vented assembly shall be contained within thermal envelope 2. No interior vapor retarder installed on inside 3. NA 4. Any air-impermeable insulation shall be a Class II vapor retarder, or shall have a Class III vapor retarder coating or covering in direct contact with the underside of the insulation. 5. Either items 5.1, 5.2, or 5.3 shall be met depending on the air-permaeability of the insulation directly under structural roof sheathing. THIS PROJECT: 5.1.3 Air-impermeable and air-permeable insulation. The minimum R-10 air-impermeable insulation shall be applied in direct contact with the underside of the structural roof sheathing for condensation control. The air-permeable insulation shall be installed directly under the air-impermeable insulation. Air-impermeable Insulation Product: HEATLOK ECO SERIES, Manufacturer: Demilec (USA) LLC, 2925 Galleria Drive, Arlington, Texas 76011 (817) 640-4900. ICC-ES Evaluation Report ESR-3198. SPRAY-APPLIED INSULATION TO BE INSTALLED BY CERTIFIED INSTALLER. HEATLOK ECO is a spray-applied rigid-medium density polyurethane closed cell foam insulation with a nominal density of 2.0 pcf. The insulation is air-impermeable when installed in accordance with the iCC-ES Evaluation Report. The insulation, at a maximum thickness of 4", has a flame-spread index of 25 or less and a smoke-developed index of 450 or less when tested in accordance with ASTM E84. Thicknesses of 5 1/2" for wall cavities and 9 1/2" for ceiling cavities are recognized, based on testing in accordance with NFPA 286, when the insulation is covered with a min. of 1/2" thick GWB installed in accordance with the applicable code. A COPY OF THE ICC REPORT FOR THE PRODUCT MUST BE PROVIDED ON THE JOB SITE FOR FIELD INSPECTOR VERIFICATION. 8 SEE SHEETS A-10 & A-11 FOR BUILDING ENCLOSURE DETAILS 5/4x10 COMPOSITE FIBER TRIM NOTE: CRYSTALITE STANDARD FRAME SKYLIGHT, TOTAL U-VALUE OF 0.55, INSTALL PER MANUFACTURER'S RECOMMENDATIONS www.crystaliteinc.com 7 SCALE: 3"=1'-0" SKYLIGHT CURB PROVIDE COMPLETE WARRANTED INSTALLATION USING MANUF. & INDUSTRY STANDARD FLASHING & METHODS. 1" O.A. GLASS RECOMMENDED: SILICONE SEALANT CURB TAPE OR SEAL AS REQ., N.B.C. CURB N.B.C. 1/16" GLAZING TAPE 1/8" GLAZING TAPE AL. RIVETS 12" O.C. MAX WEEP HOLES FIELD FASTENERS N.B.C. REF DIM 1.572.0724 GA FLASHING ALL SIDES, COLOR PER OWNER SELF ADHERING FLEXIBLE FLASHING OVER TOP OF OUTER CURB AND ONTO ROOF SHEATHING 18" ALL SIDES CEDAR BOARDS BER OWNER 1 1-HR RATED ROOF EAVE SCALE: 1"=1'-0" PER ELEVATIONS FLASHING 2x BLOCKING PER STRUCTURAL R-49 INSUL. IS REQ'D, 2" SPRAY FOAM (R-14) PLUS 10 1/4" BATT INSULATION (R-38), TOTAL OF R-52 PROVIDED, TYP. VAULTED MONO TRUSS ROOF FRAMING W/ ENERGY HEEL PER STRUCTURAL, TYP. TYPICAL NON-RATED UNVENTED MAIN ROOF - COMPOSITION ROOFING - 2 LAYERS OF 30# ROOF UNDERLAYMENT - SHEATHING & NAILING PER STRUCTURAL - VAULTED MONO TRUSS ROOF W/ ENERGY HEEL PER STRUCTURAL - UNVENTED ROOF PER IRC 806.5.5.1.3 WITH CLOSE CELL SPRAY-IN FOAM INSULATION W/ 2" SPRAY FOAM AT R-14 (HEATLOK ECO PER ICC-ES REPORT) APPLIED DIRECTLY UNDER ROOF SHEATHING, & 10 1/4" BATT INSULATION @ R-38, TOTAL OF R-52 INSULATION (MIN R-49 REQUIRED) - 1/2" GWB - PRIMAR AND PAINT (NO VAPOR RETARDER ALLOWED) 5/4x10 COMPOSITE FIBER TRIM (1) LAYER EXTERIOR 58" TYPE X GYPSUM DRYWALL FOR ALL OVERHANGS WITHIN 5' OF PROPERTY LINE, TYP., PROVIDE PERIODIC VENTS IN NON-RATED SOFFITS TYP. NON-RATED EXTERIOR WALL PER DETAIL 2 THIS SHEET FASCIA GUTTER STYLE, COLOR PER OWNER CEDAR SOFFIT PER OWNER ARCHITECTURAL DETAILSA-8SHEET TITLE:PROJECT:SHEET NUMBER:STRAIGHT ARROW N 35TH ST RENTON1218 N 35th StreetRenton, WA 98056COPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" x 36"NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEET1951.0 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CLIENT: CONSULTANT: REVISIONS: DATE: JOB NUMBER: SCALE: DRAWN BY: 01 OCTOBER 2021 AM Straight Arrow Homes, LLC 12015 NE 8th Street Suite 5 Bellevue, WA 98005 AS SHOWN Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 PR21000259 B21005267 SCALE: 1"=1'-0"2 GAS APPLIANCE - HORIZONTAL CLEARANCES HEAT SHIELD * CLEARANCE BOTTOM & SIDES * CLEARANCE TOP WALL SHIELD FIRESTOP*NON-CONBUSTIBLEZONE* NOTE: VERIFY INSTALLATION AND ALL CLEARANCES WITH MANUFACTURES VENT TERMINATION MIN. 12" CLEARANCE TO OPERABLE WINDOWS , DOORS & OPENED PERMANENTLY CLOSED APPLIANCE EXTERIORINTERIOR SCALE: 1"=1'-0" RECESSED DRYER VENT BOX1 MIN. 36" WIDE MAX. STAIR SECTION RISE: 12'3 INTERIOR STAIRS 2X4 THRUST BLOCK 2X12 STRINGERS @ 16" OC 2X FIREBLOCK'G @ TOP & BOTTOM OF EA. RUN & @ WALL ALONG STRINGER BTWN. STUDS (1) LAYER 1/2" "TYPE X" GWB AT ENCLOSED ACCESSIBLE SPACE UNDER STAIRS PER R311.2.2 OR (1) LAYER 5/8" "TYPE X" GWB @ GARAGE 2X4 STRONG BACK MAX34" - 38" ABOVE NOSING6'-8" MIN. HEADROOMPER SRC R311.5.3 10" TREAD RISER7.75" MIN 36" MIN. 3/4"-1 1/4" NOSING RETURN HANDRAIL TO WALL or TERMINATE AT NEWEL or SAFETY TERMINAL R311.5.6FLOOR FINISH: WOOD 4/A-9@ WALLPAINTED METAL RAILING W/ 1 3/4" ROUND WOOD TOP RAIL MOUNTED ON 1/4"X1" FLAT BAR W/ 1" SQUARE POSTS @ TOP & BOTTOM AND 1/2"X1" INTERMEDIATE FLAT BARS, 1/2" ROUND RAILS RUNNING BY POST ON OUTSIDE, TYP. ARTIFICIAL LIGHTING REQUIRED AT EACH LANDING OR STAIRWAY SECTION PER IRC R306.6 NOSING:RADIUS OF CURVATURE SHALL BE NO GREATER THAN 9/16". NOSING MIN 3/4" AND MAX 1 1/4". GREATEST PROJECTION NOT TO EXCEED SMALLEST BY 3/8" PER SRC R311.5.3 SCALE: 1"=1'-0" DRYER DRYER BOX FLEX TRANSITION HOSE PRE-MANUFACTURED RECESSED DRYER VENT BOX BY "THEDRYERBOX" (www.dryerbox.com), MODEL 350 FOR 2X4 WALL FRAMING OR APPROVED EQUAL, INSTALL PER MANUFACTURER'S RECOMMENDATIONS 2"RIGID PIPE NOT TO EXCEED 2" THROUGH DRYER BOX MOUNT DRYERBOX AS LOW AS POSSIBLE UNLESS A STACKABLE WASHER/DRYER IS USED NOTE: CLOTHES DRYER EXHAUST PER I.R.C. M1502 1. MAX 35' LENGTH OF DUCT FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL, REDUCED 2.5' FOR EA. 45-DEGREE TURN AND 5' FOR EA. 90-DEGREE TURN, NOT INCLUDING TRANSITION DUCT. 2. FLEXIBLE TRANSITION DUCT SHALL NOT BE CONCEALED WITHIN CONSTRUCTION, SHALL NOT EXCEED 8' AND SHALL BE A SINGLE LENGTH. 3. DUCT TERMINATION SHALL NOT BE LESS THAN 3' IN ANY DIRECTION FROM OPENINGS INTO BUILDING AND SHALL BE TERMINATED WITH A BACK DRAFT DAMPER SCALE: 1"=1'-0" PRE-CAST CONCRETE STAIR TREADS BY 'DIAMOND CONCRETE PRODUCTS, www.diamondconcreteproducts.com (1-800-655-7010)' STAIR TREADS TO BE CLOSED RISERS WITH INTEGRAL AGGREGATE WARNING DETAIL.MAX.7.75"SPACE BALUSTERS/NEWELS SO THAT A 4" DIAMETER SPHERE CANNOT PASS THROUGH AT ANY POINT 34" -38" ABV. NOSING12" MIN4" CONC. LANDING W/ INTEGRATED FOOTING METAL RAILING PER STRUCTURAL W/ INTERMEDIATE RAILS, SPACED EVENLY, LESS THAN 4" BETWEEN BALUSTERS REF PLAN ALL DECK LUMBER TREATED PER STRUCTURAL NOTES WOOD STRINGER PER STRUCTURAL BRACKETS PER MANUFACTURES INSTRUCTIONS Slope 14" / Ft, typ. NEOPRENE STANDOFF TO KEEP STRINGER ABOVE SLAB FOUNDATION PER STRUCTURAL PROVIDE FLASHING OVER TOP OF STRINGER MIN. 10" EXTERIOR STAIRS @ FRONT PORCH 1/4" / FT. SLOPE SLAB ON GRADE PER STRUCTURAL W/ 1/4" SLOPE PER FT, TYP. 7 SEE SHEETS A-10 & A-11 FOR BUILDING ENCLOSURE DETAILS 34"-38"FROM SLOPED PLANE OFTREAD NOSINGMIN. 11 2" CIRCULAR HANDRAIL 1/4" DIA TO 2" DIA. VERIFY WITH IRC FOR OTHER HANDRAILS CONFIGURATIONS ALLOWED PROVIDE 2X6 BLOCKING AT ALL LOCATIONS TO RECEIVE HANDRAIL BRACKETS NOTE: 1. ALL STAIRS TO HAVE HANDRAILS ON AT LEAST ONE SIDE OF STAIRS, TO BE CONTINUOUS WITH EXCEPTION OF NEWEL POSTS AT TOP AND BOTTOM OF STAIRS, HANDRAILS SHALL TERMINATE IN WALL OR NEWEL POST. 2. STAIRWAYS SHALL NOT BE LESS THAN 36" CLEAR ABOVE THE HANDRAIL. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5" ON EITHER SIDE OF STAIRWAY AND MIN. CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL SHALL NOT BE LESS THAN 31.5" WITH HANDRAIL ON ONE SIDE AND 27" WITH HANDRAIL ON 2 SIDES. VERIFY HANDRAIL BRACKET WITH OWNER OR ARCHITECT 4 SCALE: 3"=1'-0" STAIR HANDRAIL CONT GWB AT HEADER & JAMBS, NO TRIM, USE GWB CORNER GUARDS 5/4" SILL PROJECTS 5/8" BEYOND APRON 1/2"X2" APRON 11 4" 5/8" SCALE: 1"=1'-0" INTERIOR WINDOW TRIM8 (2) LAYERS 34" PLYWOOD W/ WARRANTED WATERPROOF ELASTOMERIC DECKING FLASHING 36" MIN ABOVE DECK, TYP.COMPOSITE TRIM BOARD 3 A-10 SECURE LEDGER PER STRUCTURAL DECK INTERIOR GARAGE FRAMING PER STRUCTURAL SLOPE 1/4" / FT CEDAR CEILING WITH 1/4" GAPS W/ BLACK INSECT SCREEN STAPLED TO FRAMING FOR VENTING 5 DECK DETAIL @ UPPER FLR SCALE: 1"=1'-0"ALL DECK LUMBER TREATED PER STRUCTURAL TYPICAL GUARDRAIL DETAIL SCALE: 1"=1'-0" POWDER COATED ALUMINUM RAILINGS BY "RAILCRAFT INTERNATIONAL" www.railcraftintl.com RAIL SPACING, FASTENERS & OVERALL DESIGN TO MEET INTERNATIONAL RESIDENTIAL CODE FOR TOP FORCE RESISTANCE. CONTRACTOR TO MEASURE EXISTING CONDITIONS & OBTAIN SHOP DRAWINGS FROM MFR., OR OWNER APPROVED EQUAL. STAINLESS STEEL CABLE RAILING BY "JOHNSON ARCHITECTURAL" OR APPROVED EQUAL. www.csjohnson.com GUARDRAIL TO BE DESIGNED PER SRC TABLE R301.5 FOR 200 lb HORIZONTAL POINT LOAD AT TOP OF GUARDS AND HANDRAILS, AND 50 lb FOR INFILL COMPONENTS +36" MIN. ABOVE FINISHED FLOOR 2 1/4" x 1 1/4" STAINLESS TOP BAR 1 1 2" SQUARE STAINLESS POSTS, 36" MAX SPACING PER MANUFACTURER <4"MaxClear3/16" INTERMEDIATE STAINLESS STEEL CABLE RAILING <4" Max Clear RAILING CONNECTION AND BOLTS PER STRUCTURAL DECK FRAMING PER STRUCTURAL PROVIDE 1/2" TREX SKIRT BOARD (2) LAYERS 3 4" PLYWOOD W/ WARRANTED WATERPROOF ELASTOMERIC DECKING 1/4" SLOPE PER FT, TYP. DRIP FLASHING & TRIM PER 12/A-10 1/4" / FT. SLOPE 6 ARCHITECTURAL DETAILSA-9SHEET TITLE:PROJECT:SHEET NUMBER:STRAIGHT ARROW N 35TH ST RENTON1218 N 35th StreetRenton, WA 98056COPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" x 36"NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEET1951.0 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CLIENT: CONSULTANT: REVISIONS: DATE: JOB NUMBER: SCALE: DRAWN BY: 01 OCTOBER 2021 AM Straight Arrow Homes, LLC 12015 NE 8th Street Suite 5 Bellevue, WA 98005 AS SHOWN Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 PR21000259 B21005267 1 SCALE: 3"=1'-0" EAVE FLASHING 4 SCALE: 3"=1'-0" EXTERIOR WALL - VENT PENETRATION ROOFING 2X PURLIN PER FRAMING PLAN6"3" LEDGER FLASHING ROOF FRAMING PER STRUCTURAL WALL CONSTRUCTION PER PLAN BUILDING PAPER BUILDING PAPER OVER SHEATHING SIDING * RAINSCREEN AIR GAP BETWEEN SIDING & ROOFING FOR VENDING AND TO AVOID SOAKING SIDING 3"INSECT SCREEN 2"2 SCALE: 3"=1'-0" ROOF TO WALL FLASHING 5 SCALE: 3"=1'-0" DECK FLASHING DETAIL @ DOOR 4" MINFLASHING4"X4" 'L" SHAPED 26 GAUGE BONDERIZED SHEET METAL FLASHING LEDGER FLASHING, STRAIGHT PIECE OVER 'L' SHAPED WITH DRIP2" MIN.DECK CONSTRUCTION PER PLAN WARRANTED ELASTOMERIC MEMBRANE OVER DECKING AND FLASHING PER MANUFACTURERS RECOMENDATIONS (UP TO 6" ON SIDEWALL TOO) WATER RESISTANT BARRIER- GREENGUARD RAINDROP, OR EQ. VERTICAL TRANSVENTED-FURRING STRIPS: "ELDORADO BATTENS" @ 16" O.C. W/ 3/8" VENTING AIR GAP SLOPE 1/4" per FOOT SHEATHING, 2 LAYERS, OVERLAP SEAMS FIBER CEMENT PANEL INSECT SCREEN @ 3/8" VENTING AIR GAP 3 SCALE: 3"=1'-0" DECK FLASHING AT WALL 9"9"C.L.EXTERIOR SHEATHING VENT HOOD W/ BACK-DRAFT FLAP 18"X18" PIECE OF 30 MIL FASATAN EDPM RUBBER CUT HOLE FOR PENETRATION (60% SMALLER THAN PENETRATION FOR SNUG FIT) & NAIL TO SUBSTRATE SIDING, INSTALL PER MANUF. INSTRUCTIONS FLASHING ACROSS TOP OF BLOCK * RAIN SCREEN WATER RESISTANT BARRIER INSECT SCREEN 14" AIR GAP CEDAR SQUARE TRIM BLOCK CAULC ON SIDES AND BOTTOM OF BLOCK EPDM GASKETEPDM GASKETVERIFY THRESHOLD THRESHOLD SET IN CONTINUOUS BED OF WATERPROOFING CAULKING COMPATIBLE W/ FLASHING SYSTEM OVER 26 GAUGE BONDERIZED SHEET METAL PAN FLASHING. FOLLOW MANUFACTURES INSTALLATION INSTRUCTIONS, TYP. SECONDARY FLASHING OR WATERPROOF DECK MEMBRANE (IF EXISTS) FOR WARRANTED INSTALLATION, TYP DOOR PER PLAN DIMS AND PER SCHEDULE KICK TRIM TO MATCH HOUSE TRIM WALL SHEATHING OVER WRB PER WALL DETAILS FINISHED FLOOR PROVIDE CONTINUOUS SNOW & ICE SHIELD FOR ANY CONCRETE PORCH THAT ABUTS WOOD FRAMING, TYP. DECK FRAMING PER STRUCTURAL FIBER CEMENT PANEL NOTES, TYP.: 1.USE CORROSION-RESISTANT FASTENERS, RECOMMENDED GALVANIZED, OR STAINLESS STEEL, TYP. 2.DO NOT BRIDGE FLOORS WTH SIDING OR FURRING 3.USE AN ELASTOMERIC JOINT SEALANT COMPLYING WITH ASTM C920 GRADE NS, CLASS 25 OR HIGHER, OR A LATEX JOINT SEALANT COMPLYING WITH ASTM C834, DO NOT CAULK HORIZONTAL JOINTS BETWEEN HORIZONTAL FLASHING & UPPER PANEL 4.INSTALL PER MANUFACTURES INSTRUCTIONS. * NOTE: RAIN SCREEN SIDING INSTALLATION IS RECOMMENDED WITH ONE LAYER BUILDING PAPER UNDER, BUT IS NOT CODE REQUIRED. CAVCLEAR ® RAINSCREEN MAT, 2 COMPONENT 95% OPEN MAT IS SUGGESTED, OR EQUAL. IF RAINS SCREEN IS NOT USED, THEN USE 2 LAYERS OF BUILDING PAPER MINIMUM, OR USE HIGH PERFORMANCE HOUSE WRAP AS WEATHER RESISTANT BARRIER WITH INTEGRATED DRAIN PATH: HYDROGAP HOUSEWRAP BY BENJAMIN OBDYKE WITH CAP FASTENERS, OR EQUAL. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION, TYP. FLOOR SYSTEM & FRAMING PER STRUCTURAL, TYP. PAN FLASHING, TURN UP ON SIDES, TYP. * L-METAL FLASHING 6" 4" VERIF Y D O O R DEPT H 5/8 "4"24 GA G-90 GALV. METAL PAN; SOLDER ALL JOINTS; PROVIDE HEMMED EDGE, AS SHOWN; SECURE PAN AT END DAMS NOTE: DOOR, THRESHOLD, COATING, AND OPENING WRAP NOT SHOWN FOR CLARITY S/S OR GALV. NAILS 3" O.C,. IN STAGGERED PATTERN SET SILL PAN IN BEAD OF NON-SKINNING BUTYL SEALANT EXTERIOR SHEATHING FASTEN END DAMS WITH SS/ OR GALV. NAILS 6 SCALE: 3"=1'-0" SILL PAN @ BALCONY DOORS ROOFING ROOF SHEATHING COMPOSITE FIBER FASCIA BOARD GUTTER UNDERLAYMENT LAPS EAVE FLASHING LOCATE GUTTER RELATIVE TO SLOPE LINE ACCORDING TO LOCAL PRACTICE GUTTER 1/2" MIN. HIGHER AT REAR EDGE THAN AT FRONT EDGE AIR SPACE BEHIND GUTTER FLASHING VENTED SOFFIT BOARD HORIZONTAL TRIM FIBER CEMENT PANEL WALL CONSTRUCTION PER PLAN WALL SHEATHING 14" AIR GAP (DO NOT SEAL) 1 4" AIR GAP SCALE: 3"=1'-0" PANEL SIDING - HORIZONTAL JOINT SCALE: 3"=1'-0" PANEL SIDING -VERTICAL JOINT 2 PANELS MAY BE REQUIRED FOR NAILING SHEATHING FIBER CEMENT PANEL VERTICAL MOLDING FLASHING TAPE WATER RESISTANT BARRIER WATER RESISTANT BARRIER AIR GAP 16d @ 4" OC 16d @ 4" OC BEARING WALL SHEARWALL FIELD NAILING PER SCHEDULE 2X STUD (TYP) INSIDE CORNER INTERIOR INTERIOR EXTERIOR FIBER CEMENT PANEL WATER RESISTANT BARRIER AIR GAP WALL SHEATHING SCALE: 3"=1'-0" OUTSIDE CORNER FIBER CEMENT PANEL WATER RESISTANT BARRIER WALL SHEATHING SHEARWALL EDGE NAILING PER SCHEDULE (TYP) 2X STUD , TYP. SCALE: 3"=1'-0" AIR GAP WALL CONSTRUCTION PER PLAN WALL SHEATHING WATER RESISTANT BARIER BASE TRIM SCALE: 3"=1'-0" INTERIOR EXTERIOR EXTERIOR EXTERIOR INTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR BATTON ELDORADO BATTON @ 16" O.C ELDORADO BATTON @ 16" O.C ELDORADO BATTON @ 16" O.C FIBER CEMENT PANEL PANEL SIDING -INSIDE CORNER PANEL SIDING -OUTSIDE CORNER PANEL SIDING -BASE TRIM 7 8 9 10 11 WARRENTED ELASTOMERIC MEMBRANE OVER DECKING AND FLASHING PER MANUFACTURER'S RECOMMENDATIONS. FLASHING W/ DRIP EDGE SHEATHING 2XTRIM COMPOSITE TRIM DECK CONSTRUCTION PER PLAN MIN. SLOPE 1/4" PER FOOT SCALE: 3"=1'-0" DECK EDGE FLASHING12 BUILDING ENCLOSURE DETAILSA-10SHEET TITLE:PROJECT:SHEET NUMBER:STRAIGHT ARROW N 35TH ST RENTON1218 N 35th StreetRenton, WA 98056COPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" x 36"NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEET1951.0 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CLIENT: CONSULTANT: REVISIONS: DATE: JOB NUMBER: SCALE: DRAWN BY: 01 OCTOBER 2021 AM Straight Arrow Homes, LLC 12015 NE 8th Street Suite 5 Bellevue, WA 98005 AS SHOWN Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 PR21000259 B21005267 ROUGH OPENING 1 2 2 4 SILL FLASHING - CUT THE SILL FLASHING (WIDTH OF ROUGH OPENING PLUS 2X WIDTH OF FLASHING) AS SHOWN, FOLD INTO OPENING, AND MECHANICALLY ATTACH THE FLASHING ALONG THE BOTTOM OF THE ROUGH OPENING. STAPLE UPPER EDGE SO BUILDING PAPER CAN BE SLIPPED UNDERNEATH. SHEATHING JAMB FLASHING - CUT JAMB FLASHING (HEIGHT = ROUGH OPENING PLUS 2X WIDTH OF THE FLASHING MINUS 1") TO FIT INTO ROUGH OPENING AND FOLD OVER TO EXTERIOR SIDE. ATTACH MECHANICALLY. BOTTOM END OF JAMB FLASHING IS TO OVERLAP THE SILL FLASHING. CORNER PROTECTION - PROTECT INTERIOR CORNERS AT SILL WITH ADDITIONAL FLASHING AS SHOWN. 1 2 3 NOTES: 1. INSTALLATION OF INTEGRAL FLANGED VINYL WINDOWS AND THE WATER RESISTANT BARRIER SHALL MEET THE MINIMUM REQUIREMENTS SET FORTH BY ASTM E 2112-01, 8.1.1.3.2, METHOD B, UNLESS APPROVED OTHERWISE BY ARCHITECT. 2. INSTALL WINDOWS PER MANUFACTURER'S RECOMMENDATIONS. IN CASE OF CONTRADICTORY INSTALLATION METHODS, CONTACT THE ARCHITECT. 3. FOR WINDOW FLASHING, USE A FLEXIBLE SELF ADHESIVE WINDOW FLASHING SUCH AS: 14 MIL GRACE VYCOR PLUS® POLYPROPYLENE BACKING FILM WITH INTEGRATED NON-ASPHALTIC, BUTYL-MODIFIED ADHESIVE, OR EQUAL. 4. PROVIDE SIMILAR FLEXIBLE FLASHING AT VENTS AND DOOR OPENINGS, AS WELL AS METAL HEAD FLASHING SIMILAR TO WINDOW DETAILS, TYP. WINDOW WEATHER RESISTANT BARRIER OVER WALL SHEATHING & OVER WINDOW HEAD FLEXIBLE FLASHING SEQUENCE OF WINDOW INSTALLATION FOR INTEGRAL FLANGED VINYL WINDOWS FLASHING BEHIND BUILDING PAPER HEAD FLASHING - INSTALL HEAD FLASHING OVER THE EXPOSED HEAD FLANGE OF THE INSTALLED WINDOW. EXTEND THE ENDS OF THE HEAD FLASHING 6" BEYOND THE ROUGH OPENING OVER THE TOP OF THE JAMB FLASHING. ATTACH TOP OF HEAD FLASHING MECHANICALLY. APPLY A CONTINUOUS BEAD OF SEALANT HORIZONTALLY ACROSS THE FACE OF THE EXPOSED FLANGE AT THE HEAD OF THE INSTALLED WINDOW AND PRESS BOTTOM OF HEAD FLASHING INTO SEALANT. 4 WATER RESISTANT BARRIER - IN WATER SHEDDING FASHION, START AT THE BASE OF THE WALL WHEN INSTALLING THE WEATHER RESISTANT BARRIER. CONTINUE TO APPLY THE WEATHER RESISTANT BARRIER IN WATER SHEDDING FASHION OVER THE JAMB FLASHING AND OVER THE HEAD OF THE WINDOW. 5 3 9"FOLD LINEFOLD LI N E 5 BUILDING ENCLOSURE NOTES The following notes and attached details shall help prevent water induced damage to buildings during and after the construction process. These notes and details are intended for smaller residential construction such as single-family, duplexes and town home buildings. For special situations and more complex buildings contact the Architect. When details are not practical to build, contact the Architect to resolve problems. The intent is to manage moisture intrusion or build-up. Developer to check the components meet all codes, specifications and the design intent. The Developer shall check all workmanship including but not limited to below-grade drainage, capillary breaks, vapor retarders, flashing, window & skylight installation, roof/wall joints and ductwork. MEASURES TO PREVENT MOIISTURE UP-TAKE CLOSE TO THE GROUND: 1.The ground surface around buildings shall be graded to slope away from the building so that rain water will run-off and will not pond near foundation walls. If this is not possible (e.g. drive way) provide a sufficient number of catch basins or trench drains. 2.Roof drains, downspouts, catch basins, foundation drains, etc. shall be tight lined and connected to a City approved discharge system to ensure that any rain water is carried away from the building. 3.An appropriate vapor retarder shall be laid on exposed earth to prevent water evaporation from soil moisture into crawl spaces. The crawl space shall be vented according to the Residential Building Code Section R408. 4.The use of a vapor retarder under concrete slabs is recommended as a capillary break to prevent moisture seepage from underlying soil into the concrete. Care should be taken not to damage the membrane during the concrete pour. 5.Perimeter foundation walls for habitable spaces shall receive a coating or a membrane system per drawings to serve as a capillary break and prevent moisture seepage into the concrete. The use of a sill sealer between concrete foundation walls and framing is recommended. MEASURES TO PREVENT MOISTURE INTRUSION / BUILD-UP, OR AIR LEAKAGE ABOVE GROUND: 1.Developer is solely responsible to ensure that all building materials are protected from moisture. Developer shall check moisture content of materials during construction.Generally the use of dry building materials is preferable but if this is not completely possible the building components shall be allowed to dry out before closing any cavities where moisture could be trapped. 2.Vinyl windows with integral flanges and doors shall be installed per ASTM E 2112-01, Method B. For other window types Developer shall choose the appropriate installation method from ASTM E 2112-01. 3.Weather barriers and flashing are always to be lapped in a water shedding fashion. Flashing shall be installed in such a manner so as to prevent moisture from entering the wall or to redirect it to the exterior. Flashing shall be installed at the perimeters of exterior doors and window assemblies, exterior wall intersections with roofs, chimneys, porches, decks, balconies and similar projections and at built-in gutters and similar locations where moisture could enter the wall. Flashing with projecting flanges shall be installed on both sides and the ends of copings, under sill and continuously above projecting trim. 4.All decks and balconies shall be sloped away from the building at a minimum rate of a quarter inch per foot. Thresholds of doors that open onto decks and balconies shall be set in sealant and curbed. 5. In exterior walls of buildings or structures, wall pockets or crevices in which moisture can accumulate shall be avoided or protected with caps or drips, or other approved means shall be provided to prevent water damage. 6. Walls between heated and unheated space shall be constructed to reduce air leakage through the use of tape, caulk, gaskets, or expanding foam sealants in conjunction with sheet membrane or panel materials. 7. Penetrations in walls and ceilings for plumbing and electrical systems with the potential of creating a path for air-leakage shall be sealed before closing walls. 8. Exhaust ducting that passes through unconditioned or unheated space shall be insulated to prevent condensation in the ducting. MEASURES TO KEEP BUILDING DRY AFTER OCCUPANCY: A part of the Developer's hand-off to the Owner shall be written information about maintenance of the building. The Developer shall encourage the Owner to keep a record book of building use, maintenance and performance problems and responses to those problems. The written information shall include but is not limited to the following notes: 1.After occupying the building the Owner should have conditions of windows and sealant joints checked yearly. 2.Attic spaces, roofs and especially roof penetrations should be inspected yearly for leaks. 3.The building should be inspected twice yearly for plumbing leaks at sinks, toilets, showers and bathtubs. 4.Check gutters and downspouts yearly (or more often if needed) and clean out as necessary. 5.In general, drainage around the building should be checked. Water ponding close to the building due to changes in landscaping should not be allowed. Also check landscaping irrigation, it should not come in contact with the building. 6 SCALE: 3"=1'-0" 4 SCALE: 3"=1'-0" SCALE: 3"=1'-0"2 FIBER CEMENT PANEL NOTES, TYP.: 1.USE CORROSION-RESISTANT FASTENERS, RECOMMENDED GALVANIZED, OR STAINLESS STEEL, TYP. 2.DO NOT BRIDGE FLOORS WTH SIDING OR FURRING 3.USE AN ELASTOMERIC JOINT SEALANT COMPLYING WITH ASTM C920 GRADE NS, CLASS 25 OR HIGHER, OR A LATEX JOINT SEALANT COMPLYING WITH ASTM C834, DO NOT CAULK HORIZONTAL JOINTS BETWEEN HORIZONTAL FLASHING & UPPER PANEL 4.INSTALL PER MANUFACTURES INSTRUCTIONS. * NOTE: RAIN SCREEN SIDING INSTALLATION IS RECOMMENDED WITH ONE LAYER BUILDING PAPER UNDER (SUPER JUMBO TEX 60 MINUTE WEATHER RESISTIVE BARRIER, OR EQ.), BUT IS NOT CODE REQUIRED. CAVCLEAR ® RAINSCREEN MAT, 2 COMPONENT 95% OPEN MAT IS SUGGESTED (WWW.CAVCLEAR.COM), OR EQUAL. IF RAINS SCREEN IS NOT USED, THEN USE 2 LAYERS OF #30 TYPE 2 BUILDING PAPER MINIMUM, OR USE HIGH PERFORMANCE HOUSE WRAP AS WEATHER RESISTANT BARRIER WITH INTEGRATED DRAIN PATH: HYDROGAP HOUSEWRAP BY BENJAMIN OBDYKE WITH CAP FASTENERS, OR EQUAL. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION, TYP. WINDOW SILL SECTION WINDOW JAMB FLASHING WINDOW HEAD SECTION INSULATE AND SHIM PERIMETER AS REQUIRED WALL CONSTRUCTION PER PLAN CEMENT BOARD SIDING, INSTALL PER MANUF. INSTRUCTION SILL FLASHING FOLDED OVER ROUGH OPENING WINDOW JAMB W/ FLANGE SHEATHING WINDOW SILL W/ NAIL FLANGE WALL CONSTRUCTION PER PLAN FLEXIBLE SILL FLASHING FOLDED OVER ROUGH OPENING SHIM PERIMETER AS REQUIRED SHEATHING FRAMING PER PLAN SHIM PERIMETER AS REQUIRED SHEATHING 1/4" AIR GAP (DO NOT SEAL) WINDOW HEAD W/ FLANGE BACKER ROD & SEALANT DRYWALL EXTERIOR INTERIOR 24 GA HEAD FLASHING R-10 INSUL CEMENT BOARD SIDING, INSTALL PER MANUF. INSTRUCTION CEMENT BOARD SIDING, INSTALL PER MANUF. INSTRUCTION * RAIN SCREEN * RAIN SCREEN * RAIN SCREEN WATER RESISTIVE BARRIER HEAD FLASHING, SEALED INSECT SCREEN WATER RESISTIVE BARRIER INSECT SCREEN 14" AIR GAP WATER RESISTIVE BARRIER EXTERIOR INTERIOR INTERIOR EXTERIOR BUILDING ENCLOSURE DETAILSA-11SHEET TITLE:PROJECT:SHEET NUMBER:STRAIGHT ARROW N 35TH ST RENTON1218 N 35th StreetRenton, WA 98056COPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" x 36"NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEET1951.0 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CLIENT: CONSULTANT: REVISIONS: DATE: JOB NUMBER: SCALE: DRAWN BY: 01 OCTOBER 2021 AM Straight Arrow Homes, LLC 12015 NE 8th Street Suite 5 Bellevue, WA 98005 AS SHOWN Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 PR21000259 B21005267