Loading...
HomeMy WebLinkAboutW-421406N 1 N 1 GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET. 2. FOR STORMWATER IMPROVEMENTS SEE GRADING AND DRAINAGE PLANS. 3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR RELOCATED, WORK SHOULD BE COORDINATED WITH EACH UTILITY. UTILITY NOTES OREMOVE EXISTING HYDRANT OR STAND PIPE rE(rvW)a21 RrM1224 Rc O REMOVE EXISTING METER L S LE(NE)=b 3- 12 _ / / v o L IDP o)r sEoz19 RCP O3 ADJUST EXISTING VAULT y 9yi _ °^0 O4 INSTALL WATER METER a 2 v SO SD a / 5 INSTALL HYDRANT ASSEMBLY xBzr' RrMa /� '� rv0 O6 ADJUST EXISTING METER .8' 12" RCP / (��J P N0 PARKING SUMPz20.3' �..1 U o / O ADJUST EXISTING VALVE BOX A� V� rr 20 ADJUST EXISTING HANDHOLE OR MANHOLE / L ♦ [- ,ES E):2132. 2. / u VVV uMa�19 g, 1 4pcp I I I o P oHP OM 21 REMOVE EXISTING VAULT — HP P HIP OHP HP oHP TO BE RELOCATED BY OTHERS' HF OH o P HP ON O REMOVE UTILITY POLE (BY PSE) 0 OHP —OHP OHP CHIP OH � OHP o P OHP HE � = v °gRREN'°N 5� s(s g *z RrM� Pon+oLE ROW H" 23 RELOCATE UTILITY POLE (BY PSE) / L O 1 3x8" °Ns 3 r22iry PpV✓ER pap/ — — zo93 oP 0RELOCATE EXISTING VAULT _ �U2 _ —o oI - T --- oHP off a°N,roRw Ed0RELOCATE EXISTING JUNCTION BOX OR SERVICE CABINET L s''� _ LL L1— _ T N c 0RELOCATE HANDHOLE OR MANHOLE � v o Lv 27 UNDERGROUND ELECTRICAL SERVICE (BY PSE) MWEL LEJ ( 2 U) 28 UNDERGROUND TELECOM SERVICE ❑+00 50 27 o — 28 TO BE RELOCATED BY OTHERS SO I O UNDERGROUND GAS SERVICE v� x _ ( 11+00 12+00 _ 14 0 O INSTALL 463-LA SERVICE VAULT 18+2� 40 ADJUST GAS VALVE (BY PSE) /� of ❑ S GRADY WAY ❑ Q (D PROTECT EXISTING FEATURE IN PLACE o r e v p d 2 El P - - ❑ J LEGEND EXISTING WATER METER O EXISTING WATER METER 592 5D Oro" —w— EXISTING WATER LINE 6 ro^ �D• r6^ ro" 3• '• `V r" — 5 — EXISTING SEWER LINE o /'V 18^ O re RO I / ARPLEBEES / RP UNE MITURN RT MCDONgL — G — EXISTING GAS LINE (�.�NV-o R EXISTING FIRE HYDRANT I i +se/ 16A PARawc I SD 5D SD soCO T EXISTING GATE VALVE I[D )x 72 RrMa22 I © SUMPa2i.9 rM RCP ®MWEL MONITORING WELL LE(Fls+s• r�2RCPa �� / N GATE VALVE / Z 2 SuaP 1y.0- 12'PCP / soce ii / o gp — 5 EP Rr 12. )R FIRE HYDRANT SocB T SD — / �G \ roP SE0az9.o P ■ WATER METER E(NW):22R1M'24.68, SD— 5� I THRUSTBLOCK ■ RECOMMENDED POTHOLE LOCATION RECOMMENDED POTHOLE -I 1 2TELELINE 0' 20' 40' 3WATER LINE 4GAS SERVICE 5STORM DRAIN 6SANITARY SEWER LINE SCALE: 1"=40' o DEsicNEn A`PRI METRO TRANSIT CAPITAL DIVISION DATE. 60 �O SUBMITTAL Jacobs D PENG NOVEMBER 2021 DRAM RAPIDRIDE 1 LINE kg King County CHHECKED: PROJECTwJ: METRO RENTON SEGMENT DMfflNGNC: xxxx E00S 1e UTILITY PLAN 1UT.05 No. RE: sion Pr acv0 DATE CHECKED: CONnuCTND. GRA 10+00 TO GRA 14+00 sHEETND: OF METROPRWECTENGINEER CXNXXYYX% 268 XXXX W-421406 S-421406 R-4214268