Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutT-4214511
r
NOTES
iQ 3 SECTION, 4 SECTION AND GREATER SIGNAL HEADS SHALL USE TYPE M MOUNTING COUPLING
INSTALLED AT OFFSET INDICATED IN PLANS.
O FIELD INSTALLED. SIGN SIZES SHALL NOT EXCEED THE MAXIMUM VALUES LISTED AT RIGHT.
0 LOCATION SHALL BE APPROVED BY CITY OF RENTON ENGINEER PRIOR TO INSTALLATION.
VIDEO DETECTION CAMERA LOCATED BETWEEN THROUGH AND LEFT TURN LANE, OR CENTERED
® ON APPROACH IF LEFT TURN LANE DOES NOT EXIST.
© l'-0"MIN. TO Z-6"MAX. FROM POLE CENTERLINE TO SIGN EDGE.
O FOR POST MOUNTED SIGNS THERE SHALL BE 2'-0" MIN. FROM THE FACE OF CURB OR THE EDGE
OF THE SHOULDER TO THE EDGE OF THE SIGN.
© PLACEMENT SHALL BE 2'-0" MIN. FROM FACE OF CURB OR EDGE OF SHOULDER; T-0" MIN. FROM
FACE OF GUARDRAIL; 4' - O" MIN. FROM CONIC. BARRIER TYPE 2 (MEASURED FROM A POINT WHERE
THE BARRIER BASE MEETS THE SHOULDER SURFACE (TOE). MEASUREMENT TAKEN FROM TRAFFIC
SIDE OF BARRIER; TO FACE OF POLE. INSTALL POLE TAG IN FOUNDATION PER RENTON STANDARD
PLAN 139.
a. VEHICLE DISPLAY
b. MAST ARM MTD. SIGN
C. STREET NAME SIGN
d. PRE-EMPT DETECTOR
E. POST MTD. SIGN
f. LUMINAIRE
g. PEDESTRIAN DISPLAY
h. TERMINAL CABINET
I. APB PUSH BUTTON
j. HANDHOLE
k. VIDEO DETECTION CAMERA
1. PTZ CAMERA
SIGNAL DISPLAY VERTICAL CLEARANCE TO ROADWAY
MIN.
I MAX.
HORIZONTAL DISTANCE
ALL
40'
1 45'
1 50'
53'-180'
FROM STOP LINE
3 SECTION 12'
16.5'
17.5'
19.2'
20.9'
22.0'
5 SECTION CLUSTER 12"
4 SECTION 12"
16.5'
17.0'
18.0'
19.T
20.8'
MEASURED FROM
BOTTOM
OF SIGNAL
HEAD
HOUSING
TO
ROADWAY
MEASURE ATTACHMENT POINT ANGLES CLOCKWISE
FROM POLE ORIENTATION LINE (El ATTACHMENT
POINT) TO THE ATTACHMENT POINT LOCATION
E2
POLE AND ALL RELATED HARDWARE I
COMPONENTS SHALL BE PAINTED RAL
9005TS "JET BLACK" UNLESS OTHERWISE
SPECIFIED BY CITY OF RENTON
TRANSPORTATION ENGINEERING.
STANDARD
TYPE
WSDOT
STANDARD PLAN REFERENCES
POLE
FOUNDATION
ELECTRICAL
STANDARD
CURB
PPE
FIXED
BREu WAY
J-20.10
J-20.15
J-20.10
J-20.15
d
J-20.10
J-20.15
PS
J-20.16
J-21.10
J-20.20
I
J-21.15
J-21.10
J-21.20
II, III, SO
WA
J-26.10
J-26.1�
NIA
N/A
90°
ATTACHMENT
``POINT
m
ALL HANDHOLES AT 180A
El
FROM El
POLE ORIENTATION LINE
(El ATTACHMENT POINT)
pANCHOR
BOLT PLATE
LOCATION STATION
n0-
POLE ORIENTATIONANGLE
(P.O.A.)DEGREES
CLOCKWISEv�
FROM OFFSET LINE TO
POLE ORIENTATION LINE
POLE ORIENTATION AND ATTACHMENT POINT
(El ATTACHMENT POINT)
i
OT-6" MEASURED FROM®T
SIDEWALK SURFACE
TO CENTER OF
PEDESTRIAN PUSH TYPE PPB
BUTTON PPB POST
XYZ 83
MASTARM
LENGTH
X Y Z (fta)
6'
19.8
8'
26.4
10,
33.0
12'
39.6
14'
46.2
16,
52.8
9 9
i
O
TYPE PS
PEQ HEAD
STANDARD
a
LUMINAIRE, MOUNTING, SHROUD AND ARM
PER STD PLANS 117.1 AND 117.3. LUMINAIR
ARM LENGTH PER DESIGN PLANS
SIGN
HEIGHT
WIDTH
AREA
b
3.0 FT
I N/A
7.5 SQ. FT.
c
3.0 FT
I N/A
36.0 SQ. FT.
e
I N/A
13.0FTI15.OSCLFT.
b
J
0
27"
0 © 0
OW
I J,
POLE AND MAST ARM PER MANUFACTURER'S PLANS. MANUFACTURER'S
PLANS SHALL BE SIGNED AND STAMPED BY A WASHINGTON STATE
THICKENED EDGE FOR FOUNDATIONS LOCATED WITHIN SIDEWALK: LICENSED STRUCTURAL ENGINEER.
ANCHOR BOLTS, PROVIDE ADEQUATE ADDITIONAL LENGTH
TO ACCOMMODATE SIDEWALK THICKNESS WHILE
MAINTAINING EMBEDMENT REQUIREMENTS. AT LEAST
TWO FULL THREADS SHALL EXTEND ABOVE THE TOP
HEAVY -HEX NUT. ANCHOR BOLTS MAY BE CUT TO
ACCOMMODATE ANCHOR BOLT COVER
45Q
SIDEWALK & THICKENED EDGE, SIDEWALK THICKNESS
DEFINED IN CONTRACT PLANS, PLACE _
ABOVE AND AROUND PERIMETER OF TOP OF FOUNDATION
6"
J' MINIMUM SPACE BETWEEN BOTTOM OF HEAVY -HEX NUT
AND CONCRETE
J- DMS OR VMS IS NOT
TYPE 1 ® ALLOWED ON THESE POLES.
VEHICLE HEAD
STANDARD
Nil
TYPE II, III & SO ASSUMES ADDITIONAL 500 FT' FOR FUTURE EQUIPMENT ON
SIGNAL STANDARD NEW SIGNAL STANDARDS.
SIGNAL STANDARD CHART
SIGNAL MAST ARM DATA
FIELD LOCATION
MAST
ARM
MOUNTING
HEIGHT (FT)
LUMINAIRE
ARM (FT)
POLE ATTACHMENT POINT ANGLES (deg)"'
FOUNDATION
DEPTHS (FT)
N(Y)(Z) -
TYPE
OFFSET DISTANCE - Z(FT) (POLE CENTERLINE TO ATTACHMENT POINT)
WINDLOAD AREAS -XY (FT)'
TOTAL
REMARKS
LENGTH
(FT)
(FT)3
POLE#
STATION
OFFSET
LT.
RT.
P.O.A.
Al
A2
B1
B2
B3
B4
B5
B6
B7
B8
39
B10
Ell
B1
B2
B3
B4
B6
B7
B9
B10
B11
B12
**
C
D
E1
F1
F2
F3'"'
G1
G2
H
11
12
TRQ
TSQ.
4'RD.
OXXXX
XXXX
X
0
LP
40
0
180
1A
XXXX
XXXX
X
0
PS
0
270
270
1B
XXXX
XXXX
X
0
PPB
0
2A
XXXX
>Q=
X
0
1
90
90
90
180
180
OXXXX
XXXX
X
LP
40
0
90
270
270
OXXXX
XXXX
X
0
1
90
180
OXXXX
XXXX
X
0
PPB
270
6A
XXXX
XXXX
X
0
PPB
270
'FOUNDATION DEPTH IS BASED ON DESIGN LATERAL BEARING PRESSURE OF 1,500-2,500 FTA3 BASED ON TBD.
"ASSUMES ADDITIONAL 500 FT' FOR FUTURE EQUIPMENT ON NEW SIGNAL STANDARDS.
"`P.O.A. MEASURED FROM "2ND-LINE".
""SIGNAGE MOUNTED TO POLE.
60% SUBMITTAL vaC�bS
3�F WEr,� J.DAMS P. ENG
F H/
Q4R�,0 ,yCTay�� JDRAWNDAM � King County
J. DAMS
CHECKE
PROJECTNO
M.WEG E00566E18 METRO
�'$'RFCC�yggF�� M. WEGENER E00558E18
`'sYpA,Ay E15G CHECKED COMRACTNO
No. REVGIOv BY APPD GATE
METRO PROJECT ENGINEER CXX%RRRRX
METRO TRANSIT CAPITAL DIVISION
RAPIDRIDE I LINE
RENTON SEGMENT
POLE SCHEDULE
S 2ND ST & MORRIS AVE S
NOVEMBER 2021
1 TS 1.02C
351351 XXXX
T-421451
R-4214351