HomeMy WebLinkAboutT-4214139GENERAL NOTES
1. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM
CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS).
2. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE.
3. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA
STANDARDS (I. E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS).
4. ALL TRANSPORTATION ASSETS THAT ARE TO BE REMOVED AND THEN REINSTALLED AT A LATER DATE DURING CONSTRUCTION SHALL BE RE
- INSTALLED TO CURRENT STANDARDS.
5. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE.
6. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION
BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO
COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS
MAINTENANCE REPRESENTATIVE.
7. MINIMUM GROUND WIRE SIZE SHALL BE#8. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN# B, THE MINIMUM GROUND WIRE SIZE
SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS.
` 8. EQUIPMENT GROUND WIRE& BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING
x & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE.
a 9. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN INSULATED WIRE OF THE
0
SAME SIZE SHALL RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE HANDHOLE. IF THE FIXTURE MANUFACTURER HAS A
F I GROUND LUG A# 8 GREEN INSULATED WIRE SHALL BE RUN FROM THE FIXTURE GROUND LUG TO THE POLE GROUND LUG
10. THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM SHALL MEET THE REQUIREMENTS OF CITY OF RENTON STANDARD PLAN 119.
11, THE CONSTRUCTION PLANS DO NOT SHOW ALL UNDERGROUND UTILITIES. THE CONTRACTOR SHALL INVESTIGATE UTILITIES PRIOR TO ANY
FOUNDATION EXCAVATION AND CONDUIT TRENCHING TO AVOID DAMAGE TO ANY UNDERGROUND UTILITIES. HAND DIGGING MAY BE
REQUIRED IN AREAS WHERE EXISTING UNDERGROUND UTILITIES CONFLICT WITH POLE FOUNDATION INSTALLATION. ALL EXISTING UTILITIES
SHALL BE LOCATED AND MARKED IN THE FIELD BEFORE PERFORMING ANY UNDERGROUND WORK. CARE SHALL BE EXERCISED WHEN
EXCAVATING, TRENCHING, OR BORING NEAR ANY EXISTING UTILITIES. UTILITY COMPANIES SHALL BE CONTACTED THROUGH THE ENGINEER
IF PROPOSED CONSTRUCTION CONFLICTS WITH ANY EXISTING UTILITIES. ALL EXISTING UTILITY INFRASTRUCTURE TO BE PROTECTED AT
ALL TIMES THROUGHOUT CONSTRUCTION.
12. ALL CONDUIT ROUTES SHOWN IN PLANS ARE TO BE FIELD VERIFIED. CONDUIT ROUTES ARE SHOWN SCHEMATICALLY.
13. NEW POLE LOCATIONS SHALL BE APPROVED BY THE ENGINEER BEFORE EXCAVATION WORK BEGINS.
14. EXISTING ROADWAY ILLUMINATION SYSTEMS WITHIN THE PACKAGE LIMITS WILL BE MAINTAINED AND PROTECTED UNLESS OTHERWISE
NOTED ON THESE PLANS.
15. LIGHT POLES IN CITY OF RENTON RIGHT-OF-WAY WILL BE LOCATED ACCORDING TO CITY OF RENTON STANDARD PLANS 117.1. 117.2 AND 124.
CONSTRUCTION NOTES
OINSTALL NEW STREET LIGHT POLE AND FOUNDATION WITH NEW LED FIXTURE PER
CITY OF RENTON STANDARD PLAN 117.1.
OINSTALL TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J40.10-04.
OREPLACE EXISTING LUMINAIRE ON THE EXISTING POLE.
(D REMOVE EXISTING STREET LIGHT POLE, FOUNDATION, BRACKET ARM, LUMINAIRE
AND ASSOCIATED WIRING.
(D INSTALL TYPE 8 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.30-04,
OSERVICE CABINET. SEE SIGNAL DRAWINGS FOR DETAILS.
OINSTALL NEW STREET LIGHT POLE AND FOUNDATION WITH STREET AND
PEDESTRIAN COMBO LIGHT PER CITY OF RENTON STANDARD PLAN 117.1.
OINSTALL PEDESTRIAN SCALE LUMINAIRE POLE AND FOUNDATION WITH NEW LED
FIXTURE PER CITY OF RENTON STANDARD PLAN 117.2.
OINSTALL NEW CONDUITS INTO EXISTING JUNCTION BOX.
10 SPLICE NEW LIGHTING CONDUCTORS WITH EXISTING LIGHTING CONDUCTORS IN
EXISTING JUNCTION BOX.
LEGEND:
EXISTING NEW
JB❑ ® 916111
P
(D
ROADWAY LUMINAIRE AND POLE
PEDESTRIAN LUMINAIRE AND POLE
JUNCTION BOX
CONDUIT
SERVICE CABINET
LUMINAIRE POLE NUMBER
' METRO TRANSIT CAPITAL DIVISION � 60% SUBMITTAL �ti.E C XCHEN PENG RAPIDRIDE I LINE NovEMBERzoz1
� c�� DRAWN
Jacobs:
q g W. DING � King County
CHECKED PRWECTN°, RENTON SEGMENT DRAWING NO
°°E N �p METRO
'^gss mg.EaE°°l�� X��NANG E00588E18 ILLUMINATION GENERAL NOTES, 1L1.N1
No. REvrION BY nPvo -ATE `a CHECKED
`°N`RNGTN° CONSTRUCTION NOTES AND LEGEND NHUTN° °E
METRO PROJECT ENGINEER C)JOOD)0( 439 XXXX
T-4214139
R-4214439