HomeMy WebLinkAboutP_Elevations_Crown Castle_211201_v2.pdf22"x34" SCALE: 1/8" = 1'-0"
11"x17" SCALE: 1/16" = 1'-0"8' 6' 4'8'2' 0'
22"x34" SCALE: 1/8" = 1'-0"
11"x17" SCALE: 1/16" = 1'-0"8' 6' 4'8'2' 0'
INFINIGY
FROM ZE RO IOT NF I IN GY
the solutions are endless
2 1 PROPOSED SOUTHEAST ELEVATIONPROPOSED SOUTHWEST ELEVATION
TOP OF FOUNDATION
ELEV. = ±0'-6" AGL
GRADE AT MONOPINE
ELEV. = 0'-0" AGL (±363.5' AMSL)
PROPOSED CROWN CASTLE
MONOPINE
PROPOSED 6'-0" HIGH
WOOD FENCE
NOTES:
THESE DRAWINGS ARE NOT INTENDED TO BE A
VERIFICATION THAT THE STRUCTURE OR
MOUNTS ARE ADEQUATE TO SUPPORT THE
PROPOSED LOADING. VERIFICATION THAT THE
STRUCTURE AND MOUNTS CAN SUPPORT THE
PROPOSED LOADING SHALL BE PERFORMED BY
A REGISTERED PROFESSIONAL ENGINEER
PRIOR TO CONSTRUCTION.
CONTRACTOR TO REFER TO THE STRUCTURAL
ANALYSIS AND MOUNT ASSESSMENT AND
VERIFY LOADING WITH THE MOST RECENT RFDS
PRIOR TO CONSTRUCTION.
PAINT NOTE
PROPOSED ANTENNAS, MOUNTS, & HARDWARE
TO BE PAINTED TO MATCH THE MONOPINE.
"LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT:
THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF
THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES
OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION,
MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS
SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF
THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING
FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE
LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE
ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY
TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT
TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS
INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING
EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO
YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO
GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR
NOTICE TICKET.
TOP OF FOUNDATION
ELEV. = ±0'-6" AGL
GRADE AT MONOPINE
ELEV. = 0'-0" AGL (±363.5' AMSL)
OF PROPOSED AT&T PANEL ANTENNAS
ELEV. = ±90'-0" AGL
TOP OF PROPOSED AT&T PANEL ANTENNAS
ELEV. = ±94'-0" AGL
PROPOSED CROWN CASTLE
MONOPINE
TOP OF PROPOSED MONOPINE
ELEV. = ±94'-0" AGL
PROPOSED AT&T ANTENNAS
WITH ASSOCIATED EQUIPMENT
MOUNTED TO MONOPINE
OF PROPOSED T-MOBILE PANEL ANTENNAS
ELEV. = ±80'-0" AGL PROPOSED T-MOBILE ANTENNAS
WITH ASSOCIATED EQUIPMENT
MOUNTED TO MONOPINE
TOP OF PROPOSED MONOPINE BRANCHES
ELEV. = ±99'-1" AGL
OF FUTURE CARRIER PANEL ANTENNAS
ELEV. = ±70'-0" AGL FUTURE CARRIER ANTENNAS
WITH ASSOCIATED EQUIPMENT
MOUNTED TO MONOPINE
PROPOSED 6'-0" HIGH
WOOD FENCE
EXISTING
TREE, TYP.
EXISTING
TREE, TYP.
PROPOSED AT&T ANTENNAS
WITH ASSOCIATED EQUIPMENT
MOUNTED TO MONOPINE
PROPOSED T-MOBILE ANTENNAS
WITH ASSOCIATED EQUIPMENT
MOUNTED TO MONOPINE
FUTURE CARRIER ANTENNAS
WITH ASSOCIATED EQUIPMENT
MOUNTED TO MONOPINE
BOTTOM OF TOWER STEEL
ELEV. = ±0'-0" REF., ±1'-0" AGL
BOTTOM OF TOWER STEEL
ELEV. = ±0'-0" REF., ±1'-0" AGL
NOTE:
THE CROWN CASTLE SCOPE OF WORK
INCLUDES ITEMS THAT ARE TO BE
USED BY MULTIPLE CARRIERS OR ARE
CALLED OUT AS "CROWN CASTLE".
ITEMS CALLED OUT AS "AT&T" OR
"T-MOBILE" ARE TO BE INSTALLED
UNDER SEPARATE SCOPES OF WORK.
OF PROPOSED AT&T PANEL ANTENNAS
ELEV. = ±90'-0" AGL
TOP OF PROPOSED AT&T PANEL ANTENNAS
ELEV. = ±94'-0" AGL
TOP OF PROPOSED MONOPINE
ELEV. = ±94'-0" AGL
OF PROPOSED T-MOBILE PANEL ANTENNAS
ELEV. = ±80'-0" AGL
TOP OF PROPOSED MONOPINE BRANCHES
ELEV. = ±99'-1" AGL
OF FUTURE CARRIER PANEL ANTENNAS
ELEV. = ±70'-0" AGL