Loading...
HomeMy WebLinkAboutP_Elevations_Crown Castle_211201_v2.pdf22"x34" SCALE: 1/8" = 1'-0" 11"x17" SCALE: 1/16" = 1'-0"8' 6' 4'8'2' 0' 22"x34" SCALE: 1/8" = 1'-0" 11"x17" SCALE: 1/16" = 1'-0"8' 6' 4'8'2' 0' INFINIGY FROM ZE RO IOT NF I IN GY the solutions are endless 2 1 PROPOSED SOUTHEAST ELEVATIONPROPOSED SOUTHWEST ELEVATION TOP OF FOUNDATION ELEV. = ±0'-6" AGL GRADE AT MONOPINE ELEV. = 0'-0" AGL (±363.5' AMSL) PROPOSED CROWN CASTLE MONOPINE PROPOSED 6'-0" HIGH WOOD FENCE NOTES: THESE DRAWINGS ARE NOT INTENDED TO BE A VERIFICATION THAT THE STRUCTURE OR MOUNTS ARE ADEQUATE TO SUPPORT THE PROPOSED LOADING. VERIFICATION THAT THE STRUCTURE AND MOUNTS CAN SUPPORT THE PROPOSED LOADING SHALL BE PERFORMED BY A REGISTERED PROFESSIONAL ENGINEER PRIOR TO CONSTRUCTION. CONTRACTOR TO REFER TO THE STRUCTURAL ANALYSIS AND MOUNT ASSESSMENT AND VERIFY LOADING WITH THE MOST RECENT RFDS PRIOR TO CONSTRUCTION. PAINT NOTE PROPOSED ANTENNAS, MOUNTS, & HARDWARE TO BE PAINTED TO MATCH THE MONOPINE. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. TOP OF FOUNDATION ELEV. = ±0'-6" AGL GRADE AT MONOPINE ELEV. = 0'-0" AGL (±363.5' AMSL) OF PROPOSED AT&T PANEL ANTENNAS ELEV. = ±90'-0" AGL TOP OF PROPOSED AT&T PANEL ANTENNAS ELEV. = ±94'-0" AGL PROPOSED CROWN CASTLE MONOPINE TOP OF PROPOSED MONOPINE ELEV. = ±94'-0" AGL PROPOSED AT&T ANTENNAS WITH ASSOCIATED EQUIPMENT MOUNTED TO MONOPINE OF PROPOSED T-MOBILE PANEL ANTENNAS ELEV. = ±80'-0" AGL PROPOSED T-MOBILE ANTENNAS WITH ASSOCIATED EQUIPMENT MOUNTED TO MONOPINE TOP OF PROPOSED MONOPINE BRANCHES ELEV. = ±99'-1" AGL OF FUTURE CARRIER PANEL ANTENNAS ELEV. = ±70'-0" AGL FUTURE CARRIER ANTENNAS WITH ASSOCIATED EQUIPMENT MOUNTED TO MONOPINE PROPOSED 6'-0" HIGH WOOD FENCE EXISTING TREE, TYP. EXISTING TREE, TYP. PROPOSED AT&T ANTENNAS WITH ASSOCIATED EQUIPMENT MOUNTED TO MONOPINE PROPOSED T-MOBILE ANTENNAS WITH ASSOCIATED EQUIPMENT MOUNTED TO MONOPINE FUTURE CARRIER ANTENNAS WITH ASSOCIATED EQUIPMENT MOUNTED TO MONOPINE BOTTOM OF TOWER STEEL ELEV. = ±0'-0" REF., ±1'-0" AGL BOTTOM OF TOWER STEEL ELEV. = ±0'-0" REF., ±1'-0" AGL NOTE: THE CROWN CASTLE SCOPE OF WORK INCLUDES ITEMS THAT ARE TO BE USED BY MULTIPLE CARRIERS OR ARE CALLED OUT AS "CROWN CASTLE". ITEMS CALLED OUT AS "AT&T" OR "T-MOBILE" ARE TO BE INSTALLED UNDER SEPARATE SCOPES OF WORK. OF PROPOSED AT&T PANEL ANTENNAS ELEV. = ±90'-0" AGL TOP OF PROPOSED AT&T PANEL ANTENNAS ELEV. = ±94'-0" AGL TOP OF PROPOSED MONOPINE ELEV. = ±94'-0" AGL OF PROPOSED T-MOBILE PANEL ANTENNAS ELEV. = ±80'-0" AGL TOP OF PROPOSED MONOPINE BRANCHES ELEV. = ±99'-1" AGL OF FUTURE CARRIER PANEL ANTENNAS ELEV. = ±70'-0" AGL