HomeMy WebLinkAboutPN_Project Narrative_Crown Castle_211201_v2.pdfAdministrative Conditional Use Permit – Project Narrative
Crown Castle 831070 A-Team / 816039 Sunset Relo
PROPOSAL SUMMARY INFORMATION
Site Name: 831070 A-Team (816039 Sunset Relo)
Applicant: Crown Castle
2055 S Stearman Dr
Chandler, AZ 85286
Carriers: New Cingular Wireless PCS LLC (AT&T)
T-Mobile
Representative: Lynx Consulting
Jennifer Taylor
17311 135th Ave NE Suite A-100
Woodinville, WA 98072
(206) 228-2127
jtaylor@lynxconsulting.org
Property Owner: Renton Housing Authority
Scope of Work: Proposal to construct monopine and fenced compound for minor
communication facility for collocation by two (2) wireless carriers.
Parcel: 722780-2040
Address: 2902 NE 12th Street
Jurisdiction: City of Renton
Zoning: R-14
Estimated Project Cost: $185,000.00
Amount of cut/fill: 230 CY Cut & 230 CY Fill
7,060 sq ft of new & replaced impervious surface
12,300 sq ft of disturbed area for clearing for utilities, grading, and
construction access.
Trees to be removed: 6 within lease area
3 within access road
Crown Castle 831070 A-Team / 816309 Sunset Relo
Administrative Conditional Use Permit Application
1
PROPOSAL DESCRIPTION
Crown Castle is a wireless communications tower company operating in the City of Renton. Crown
Castle proposes to construct a new minor communication facility tower to replace an existing
communication tower on adjacent property that will be removed. AT&T and T-Mobile will collocate
on the proposed replacement communications tower.
The proposed wireless communication tower is a monopine (a stealth tower designed to appear as a
tree). The tower will be 94’ tall with branches extending to 99’1” tall. The structure will be located
within a 34’ x 50’ fenced equipment compound. This will be an unmanned facility, does not require
water or sewer, and will not generate a significant traffic impact on the surrounding road system.
Existing access roads and driveways will be used and upgraded as needed. Access will be from
Harrington Ave NE.
The subject parcel is zoned (R-14). Adjacent zoning to the north, east, and west of the site is also
Residential (R-14). Adjacent zoning to the south is Center Village (CV). The site was previously used
for a library and is now Renton Housing Authority health services building. Adjacent properties are
primarily multi-family residential. There are no critical areas in the vicinity of the proposed site.
Per the following in Renton Municipal Code 4-2-060 Zoning Use Table, this proposal for a stealth
tower requires an Administrative Conditional Use Permit. Additionally, as the proposed tower
exceeds 60 feet, a SEPA Review is required. Accordingly, this application package includes an
Administrative Conditional Use application and Environmental Checklist. This application
previously was submitted with a requested height waiver included. That has been removed as the
structure height has been reduced.
Crown Castle has designed this project to meet City of Renton local ordinances and zoning
regulations while providing the wireless communications coverage that is necessary for the carriers
to provide service and enhance their network in the City of Renton.
CRITERIA COMPLIANCE NARRATIVE:
For Wireless Communication Facilities:
Renton Municipal Code (RMC) 4-4-140 D. COLLOCATION REQUIRED:
Crown Castle 831070 A-Team / 816309 Sunset Relo
Administrative Conditional Use Permit Application
2
RESPONSE: This project is a relocation of a facility due to an existing tower being
removed for property redevelopment. There will be two carriers on the proposed
replacement tower. There are no existing tower or support structures within the geographic
area that meet the applicant’s engineering requirements for height or structural capacity to
provide antenna collocation for two carriers.
RMC 4-4-140-F STANDARDS AND REQUIREMENTS FOR ALL TYPES OF WIRELESS
COMMUNICATION FACILITIES:
RESPONSE: Ground equipment for the proposed carriers cannot be placed underground.
The project proposes to place equipment within a wood fence and landscaped area for
screening. Sheet A-3 of the submitted plan set demonstrates that the compound is only large
Crown Castle 831070 A-Team / 816309 Sunset Relo
Administrative Conditional Use Permit Application
3
enough for the two proposed carriers and a third future collocator. No generators are
proposed.
RESPONSE: The maximum height allowed for a stealth tower is 150’. A faux tree has
additional height limitations related to the average height of existing trees. This proposed
monopine tower will be 99’1” including branch height and does not exceed this criteria. The
complete tree survey is discussed in a later section of this narrative. The site does not fall
within the Airport Influence Area. Crown Castle will verify the tower height meets FAA
regulations.
RESPONSE: This proposal includes a stealth structure designed to appear as a tree in order
to better meet the character of the site which includes numerous trees. Existing vegetation
and trees are being retained as much as possible and supplemented with additional
landscaping. The base of the structure will be enclosed within a wood fence that fits the
character of the site.
RESPONSE: The applicant is requesting a reduction in the setback requirement. Due to
the shape of the property and the layout of the existing building and parking lot, the
property cannot accommodate a one-to-one setback. The proposed tower will be 99’1”
including branches and will be engineered to meet all code requirements. The project has
been designed with tower setbacks of 75’ from the north property line, 60’ from west
Crown Castle 831070 A-Team / 816309 Sunset Relo
Administrative Conditional Use Permit Application
4
property line and 57’11” from the east property line. Crown Castle is requesting approval of
this reduced setback.
RESPONSE: All equipment will comply with the noise standards in compliance with this
section. No generator is proposed.
RESPONSE: A six-foot wood fence surrounding the facility is proposed.
RESPONSE: No lighting of the stealth tower is proposed. No advertising is proposed. A
site identification placard will be placed on the security fence. The proposed stealth tower
will be designed to meet code criteria. Engineering documentation will be provided with
building permit application associated with this land use application. The proposed facility
will comply with all FCC regulations and standards.
RMC 4-4-140-I STEALTH TOWER STANDARDS:
Crown Castle 831070 A-Team / 816309 Sunset Relo
Administrative Conditional Use Permit Application
5
RESPONSE: This proposal for a faux tree (monopine) will be located less than 100 feet
from existing trees. The enclosed survey and tree survey map shows that there are a number
of trees directly adjacent to the compound and include cedars, fir, maples and more.
RESPONSE: A tree survey was completed and is submitted with this application. It shows
heights of mature trees in the general vicinity, both on the property and on adjacent
properties that fall within sight lines of the tower. The average of 37 trees with heights
ranging from 30’ to 100’ was 69.1 feet. Each of the carriers that will collocate on the proposed
replacement tower requested additional height originally for coverage objectives. Due to
concerns with aesthetics the proposed tower has been reduced in height to meet the
maximum allowed per the tree survey which is 30’ in additional to the average of 69.1 feet.
The proposed monopine is 99’1” which meets this requirement.
RESPONSE: The proposed monopine will be ordered from Valmont. Included with the
application is a brochure on their pine tree tower solutions. The monopine will be designed
to be as natural in appearance as is feasible. Valmont proposes 3 branches per foot ranging
in length from 4’ to 10’ and starting at 20 feet in height. Please see enclosed brochure and
photo renderings.
RESPONSE: All items affixed to the exterior of the tower will be painted/colored to match
to ensure they blend with the structure.
Crown Castle 831070 A-Team / 816309 Sunset Relo
Administrative Conditional Use Permit Application
6
RMC 4-4-140-L. APPLICATION SUBMITTALREQUIREMENTS:
RESPONSE: Included with this application is an RF justification letter from each wireless
carrier describing the relocation of the tower, the need for the site in this area, and the
coverage loss without replacement. No generator is proposed therefore no noise report is
included.
RESPONSE: Photo simulations are provided with views from four (4) vantage points and a
map demonstrating where each image was taken from.
RESPONSE: Due to this proposed tower being a stealth monopine, the type of attachments
is set by the manufacturer. Visual mitigation is achieved through use of the stealth tower
which are depicted in the development plan set, photo simulations, and manufacturer
brochure. The plan set also references the proposed wood fence to screen views of ground
equipment and proposed landscaping around the base of compound.
Crown Castle 831070 A-Team / 816309 Sunset Relo
Administrative Conditional Use Permit Application
7
RMC 4-9-030. DECISION CRITERIA – WIRELESS COMMUNICATION FACILITY
RESPONSE: Crown Castle is proposing a 99’1” monopine structure in order to better blend
with existing trees in the surrounding multi-family residential and commercial
neighborhood. The location chosen has a building the screens the facility from the south.
The use of wood fences, additional landscaping and stealth design allow it to better blend
with the existing vegetation of the neighborhood.
RESPONSE: The site and the surrounding properties are zoned residential. The
surrounding properties have multi-family structures and the subject site is housing authority
building/community health center. Due to the shape of the parcel and location available
onsite for placement of the monopine, the applicant is requesting reduced setbacks to the
property lines. The proposed tower will be 57’11” from the east property line which is the
smallest setback. Landscaping and a wood fence are proposed around the base of the tower
to blend better with residential style.
This site will not generator traffic or noise to a degree that makes it incompatible with the
adjacent uses. The location and type of communication facility will not impact circulation
or use of neighboring properties. The facility will have no effect on development and use of
neighboring properties.
It is necessary for this type of facility to be located in the region it will serve which is
recognized by the Comprehensive Plan in Chapter 9 the Utility section. This project is
necessary due to the required removal of existing communication site nearby and will not
introduce a new use to the vicinity or result in an increase in the total number of
communication sites.
Crown Castle 831070 A-Team / 816309 Sunset Relo
Administrative Conditional Use Permit Application
8
RESPONSE: The proposed communication facility replaces an existing communication
facility on adjacent property. Other development in the area includes multi-family
residential properties, government services, and commercial uses. This is a replacement
facility and is not a new use being introduced to the area and therefore not outside the
character of the neighborhood. The communication facility is a passive use that will not
affect use of the housing authority/community services property.
RESPONSE: The topography of the site is generally flat. The proposal does not involve
significant amounts of ground disturbance or increases in paved surfaces. There are
numerous trees and plants that will be retained and supplemented with additional
vegetation. A total of 6 trees are proposed to be removed that are within the leased area. An
additional 3 trees will be removed in order to complete an access route. The design of the
stealth tower was selected to blend in with the surrounding tree. Please see tree retention
and landscape plan and photo simulations.
The site will be accessed from Harrington Ave NE via the parcel to the north. That existing
route will be upgraded and extended as needed to reach the facility.
RESPONSE: The project will need all noise requirements. No generators are proposed. No
light or glare impacts are anticipated as no lighting is proposed and only non-glare colors
are used. The proposed fence will be wood and the tower is a monopine to reduce visual
impacts.
RESPONSE: This project is a relocation of an existing site that will be removed. There are
no available towers in the area that are feasible for maintaining current coverage and can
accommodate the equipment needed. There are two proposed carriers (AT&T and T-
Mobile) and the site has been designed with space for future collocation.
RESPONSE: The proposed facility is compatible with the general purpose, goals, and
standards of the Comprehensive Plan Utilities Element Goal U-Q: “Promote timely and
orderly expansion of all forms of telecommunications service within the City and its
planning area.” Without a replacement communication facility in place when existing
Crown Castle 831070 A-Team / 816309 Sunset Relo
Administrative Conditional Use Permit Application
9
facilities are removed, service for wireless users in the surrounding area would be negatively
affected. The proposed facility is allowed in the zone and falls within the height allowed for
stealth towers.
RESPONSE: Supplemental landscaping is proposed. See Landscaping Plan.
RMC 4-9-250. MODIFICATION PROCEDURES:
RESPONSE: This proposal and requested modification meets with the goals of the
Comprehensive plan Land Use Element such as Goal L-D to provide essential facilities,
Policy L-6 for efficient design of essential facilities which this project fits as it allows for the
continued service from two wireless carriers with space for a third and Goal L-BB in the use
of a monopine design for the new communication facility to have reduce aesthetic impact.
Crown Castle has removed the request for a modification of the stealth tower limit due to
review comments concerning aesthetics of the facility.
RESPONSE: The tower will be engineered by the manufacturer to ensure safety and
function of the facility. The additional height requested above the average tree height in the
area will not reduce the safety of the facility.
RESPONSE: Although the tower will be taller that other structures and the trees in the area
the height meets the code requirements and is not a significant difference that would lead to
substantial impact. The facility does not lead to increased traffic or other changes to
neighborhood uses.
Crown Castle 831070 A-Team / 816309 Sunset Relo
Administrative Conditional Use Permit Application
10
RESPONSE: The Code encourages stealth facilities and allows for monopines to be at 120
feet. The code suggests the type of stealth tower should be chosen to fit in with the
surroundings. In this case there are numerous trees in the area and a monopine is the best
option to provide collocation for multiple carriers with multiple antennas as well as fit with
the neighborhood.
RESPONSE: Crown Castle is requesting to place a new communication facility because of
redevelopment of a nearby property which requires the removal of an existing facility. The
new location is closer to tall trees. This allows for the use of a monopine design to fit in with
the neighborhood but also requires that the antenna locations extend above tree heights for
coverage. This application request places the top height of the monopine at 30’ above the
average tree height in the area. The photo simulations submitted with the application
document the proposed tower will still fit within in the area.