HomeMy WebLinkAboutR-420307M C) N 1 Uj ''r•1 T w O a THIRD DAY DESIGN CIVIL ENGINEERING 5918 WALLER RD E TACOMA, WA 98443 (253) 256-1812 DocuSlgn Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 ------------ ��� EX. SEWER MAIN I I I I l PROPERTY LINE F�IEWESR I I I Z I ---SPOOL NEEDED) I I I I S-0" MIN I I I O I R STUB I I 1 'Y FUTURE 4" SIDE SEWER M I I 1 I 2"x 4" STUD MARKING POST PAINTED I I I I 6" CAP/ WHITE WITH THE WORD "SEWER" STENCILED E X 6" TEE i i i I IN 3" HIGH BLACK LETTERS AND N6 WIRE SIDEWALK i ? WRAPPED AROUND THE STUD AND I I I I I EXTENDED TO THE TOP OF THE STUD COUPLING TVP I I I I ( ) L_J_L--------- J < crJ 13 1 6"X6"X6" SURFACE CLEANOUT NTH CAST IRON RING AND COVER O (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR 1 APPROVED EQUAL, SPECIFY "SEWER" ON LID), 2 CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD I CONCRETE PAD TO BE 8" IN DEPTH rT_________ __-____________________T_� F_ -J .•T -- BEND AS . B" REQUIRED EXISTING SANITARY _ SEWER MAIN 3 --2.09. MIN SLOPE \ ` FUTURE 4" SIDE SEWER '1-6" SEWER STUB 6"X6"X6" WYE FUTURE 6"x 4" REDUCER `SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL) C PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED NTH A ROMAC SADDLE (OR APPROVED EQUAL) D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F HOPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL NOTES 1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHALL HAVE A MINIMUM 2 7. SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE, THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RICHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 110 2 6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405 7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON SIDE SEWER STUB STD: PLAN -406.1 PUBLIC WORKS INSTALLATION APP '1C DEPARTMENT Martin PaStuChOV26/202 (SEWER MAIN TO PROPERTY LINE) B0. DATE 40 .le/ J CEMENT CONCRETE � SIDEWALK 1 !` \ / i CEMENT CONC7iETt- i ctlRe a GUTTER j (BEE NOTE 3) 11 a IT r molsou NC cum aOUTTER (BEE DETAILTNa SHEET) �9 TYPE C26 - ISOMETRIC VIEW (COMMERCIAL, WITH eUFTTei) NOTES 1. When a driveway width exceeds 15 feet, construct a fun depth axpana]on lot rdwith 318" Joint Biter abng th9 driveway lane IInas (se0 std. plan 102). Construct expansion Joints parallel with the cen•.erllne as required at 19 maximum Spacing vlAlan driveway widths exceed Yr. 2. See aid. plan 102 for sidewsk details. 3. Curb and gutter shown, other curb designs may be spadled. See std. plan 101 for curb details. 4. Not used. 5. The engineer will design all driveways to Include elevations at a1 points marked with symbol')'. All elevations sre st the back of curb top on uphil side. 6. Not used. 7. For Driveway Widths see DRIVEWAY STANDARDS (See NOTE 10). The expansion joints (see old. plan 102) shall be spaced as shown In the corresponding harrletrlc New. FAkECIFdaE M DEPRESSED raW OF TAT CONTRACTION JOI�c six ON THIS IIHT ETD PLAN 102 - SVE•. r b - 1?R IOPOF I.- __ - • _ I _ - ROADWAY k 1� I-r V.r NDr@ OM MYLONWnMPftWVW ION JOEIIaOVALMFIaJ.OBIM DEPREWWPAONOLrrHIC CURB a GUTTER DETAA 8. Slopes shall comply with sections R303.2.1 or R30322 or - FAM OF ADJACENT CUM R3032.3 of the Revised Draft GuldoUna For Acomible Public 1' Rigbts-of-Way of November 23, 2005 (PROWAG). 9. Curb returns for any Type C-MAX Driveway may be approved an a ca9e•byCBQe basis. , - . '--aurtER SURFACE 10. STREET STANDARDS . Renton Municipal Code (RMC) P R. Title IV Development RegulaVorls CHAPTER 6 STREET AND UTILITY STANDARDS =� - Section 4-6r060STREET STANDARDS DEPRESSED CURB DETAIL AT RESIDENTULL OR COIMERCIItI DRIVEWAYS, AND ALLEY5 DRIVEWAY STANDARDS ■ Renton Municipal Cade (RA4C) Title IV Development Regulations DdveWay Example: TYPE C1 B CHAPTER R-RoWdWed, C CWraWCW ---- 1 Ii CITY-WIDE PROPERTY DEVELOPMENT STANDARDS NLmewrorLr . — -- Section 4-4-080 PARKING, LOADING AND DRIVEWAY (MI taro CAN REGULATIONS 6.eMrrar(Prra(taSMF). BIm11•N &ffw 1 /27/2022 CEMENT CONCRETE DRIVEWAY " y PLAN - 1042 ENTRANCES - NOTES AND DETAILS }�[ �L_ NO. REVISION 1 12 011 DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 ALL 90 TURNS SMALL BE ACCOMPLISHED BY M EANS OF A WYE WITH CLEANOUT AND a" BEND AS REQUIRED (NO GREATER 45 BEND TWO 45' BENDS SHALL NOT BE THAN 45- BEND) EVERY 2ND CHANGE 4" CLEANOUT WYE PATH ACCEPTABLE (SEE NOTE 11) IN DIRECTION OR GRADE WILL REQUIRE 45 BEND AND PLUG A CLEANOUT WYE (SEE NOTE 11) I (SEE NOTE 11) z J J z HOUSE gl a HOUSE ill d HOUSE of HOUSE a 1 3 -0" MIN 4" SEWER PIPE SURFACE CLEANOUT 4" SURFACE 'a (TYPICAL) 6"x 6"x6" WYE CLEANOUT 4" SEWER PIPE, SEE NOTES 2 (SEE STp PLAN - 407) WYE �4" 4" TEST TEE WITH AND 3 MINIMUM LINE SIZE FOR 1 WYE WITH PLUG FACE UP OTHER THAN SINGLE FAMILY IS 6" R 0 W LINE CLEANOUT (TYPICAL) I _ROW LINE 3' MIN 6"x 4" REDUCER U F N F z V V (TYPICAL) G _ MAIN SEWER LINE , , x NOTES z IF THE BUILDING SEWER SERVES ANY FIXTURE HAVING x i FLOOD LEVEL RIMS LOCATED BELOW THE ELEVATION 1 PRIOR TO INSTALLATION OF A SANITARY SEWER CONNECTION, A o OF THE NEXT UPSTREAM MANHOLE COVER OF THE SIDE -SEWER PERMIT MUST BE PURCHASED FROM THE CITY OF U PUBLIC SEWER SYSTEM, A BACKFLOW PREVENTION RENTON PUBLIC WORKS DEPARTMENT. 0 13 DEVICE SUCH AS CLEAN CHECK EXTENDABLE o '� BACKWATER VALVE OR APPROVED EQUAL SHALL BE 2 FOR INSPECTION OF S1DE SEWER, CALL 24 HOURS IN ADVANCE 2 m INSTALLED THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER PERMIT 4" FLEXIBLE COUPLING (FERNCO OR EQUAL) SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE 0 ON SITE WHEN INSPECTOR ARRIVES AT APPOINTED TIME DO NOT o BACKRLL THE DITCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR rn SURFACE CLEANOUT m 4"x 4•'x4" WYE 3 SIDE SEWER PIPE AND FITTINGS SHALL BE PVC SDR 35 WITH RUBBER 4" PIPING GASKET JOINTS UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT PLAN BUILDING DRAIN FOR 4 A MINIMUM GRADE OF 2% (1/4" PER FOOT) MUST BE MAINTAINED LOW ELEVATION HOUSE WITH A 4" PIPE IN THE EVENT A 2% GRADE CANNOT BE MAINTAINED WITH THE APPROVAL OF THE PUBLIC WORKS INSPECTOR, THE MAIN TO CONTRACTOR MAY INSTALL A 6" DIAMETER SIDE SEWER AT NO LESS R 0 W LINE 5 FEET R 0 W. LINE TO CLEANOUT I MAX THAN i.L SIDE SEWER STUB BUILDING SEWER BUILDING DRAIN 5 INSTALL SIDE SEWER WITH 2' MINIMUM COVER 18" COVER IS ALLOWED J FEET MIN (— AT THE HOUSE IF OUTLET IS SHALLOW `\\ 6 ALL BUILDING SEWER AND SIDE SEWERS SHALL HAVE BEDDING IN \ ACCORDANCE WITH STANDARD PLAN 405 `•� m - + �rN �I c �' x - s = . n, cy a 7 WHENEVER FEASIBLE, THERE SHALL BE A MINIMUM 5 FOOT z o N g o # ? m+ v F % j i o HORIZONTAL SEPARATION BETWEEN SANITARY SIOE SEVERS AND ALL `Q^ � � � m C v C x = 10o+, �, o x - OTHER UTILITIES rn` ,41„ mm D� 0 2 m m. �Ati °v o m m 0 z n 8 SIDE SEWER TESTING SHALL CONSIST OF PLACING A PLUG IN THE y z Au z o A �m �� z0 0 TEST TEE AND INSTALLING A 4-FOOT RISER PIPE ON THE CLEANOUT m0 0 ti C > = AT THE BUILDING. THE SIDE SEWER PIPE SHALL BE FILLED TO WITH ♦ r. : i y - ram C WATER TO THE TOP OF THE RISER PIPE NO LOSS OF WATER SHALL mi ^' I �' ,Q ^t 0 OCCUR FOR A PERIOD OF 10 MINUTES. THE SIDE SEWER MAY BE v z 0 CONNECTED TO THE BUILDING FOLLOWING THE SUCCESSFUL m a m COMPLETION OF THE LEAK TEST Z, 9 THE CLEANOUT AT THE RIGHT-OF-WAY SHALL BE INSTALLED PER m PLAN STANDARD PLAN 4061 THE CLEANOUT AT THE BUILDING SHALL BE DIN BUILPL SEWER INSTALLED TO SURFACE GRADE ALL OTHER CLEANOUTS SHALL BE INSTALLATION INSTALLED TO WITHIN 12" OF THE SURFACE 10 IF SIDE SEWER STUB IS NOT AVAILABLE THE OWNER SHALL BE RESPONSIBLE FOR ITS INSTALLATION PER STANDARD PLAN 406 1 ALL WORK WITHIN STREET RIGHT-OF-WAY SHALL BE DONE BY A LICENSED AND BONDED CONTRACTOR CALL 811 BE FORE YOU DIG 11 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC OF t0 RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102 www collbeforeyoud;g Ong 12 ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT (WISHA) TYPICAL BUILDING SEWER STD. PLAN -406.2 PUBLIC WORKS APP°^etlby DEPARTMENT FROM PROPERTY LINE TO Martin PaStUCffW26/202 BUILDING CONNECTION DB DATE _VAR (SEE NOTE E) (SEE NOTE EI tE LF Of PAVED DRIVEWAY REWIRED 33 EXPANSION JOW nYRI CE (SEE $TO PUN ID11 CO i St 1 NOTE E Z m u -" SEE NOTE 1 CEWNI CONCRETE , RJJ.W WITH SLOPE ITYF_I 1JN TWJ a cLgw SSEE GurrER NOTE ]I JE- CONTRACTION JOINT GYP, (SEE SrO, PUN 1St1 PLAN NEW VARIES "' 13'EE ridfF t41 S ]% LW SEE NOTE S ITYPI e• kW DEPRESSED CUN M GUTTER CEMENT CONGIETE 741 EXPMSON JOINT rIN NIN TYP 1 IEEE MOTE II SIOEVI RE STD.PUN wE; 9 SECTION A ,.._— -- --, ,n R(TYPI YTEWMSNIDM tD� o•rERENCE W noPE Tux - _ � 1- - -DRVEWAY WdaSITNE SLOPE (SLOPE SIK7IYN F,TAr.9EMTE01 T 1E!• NEw�REuI' D • D D • 11- NEGATIVE XOff SE N SHOWN 7EG1 MIN CEMENT ALX :® PUBLIC WORKS DEPARTMENT SURVEYED: TERRANE DESIGNED: AE DRAWN: CHECKED: AE DATE APPR APPROVED: AE CEMENT CONCRETE CURS S GUTTER ISER MOTE 31 TYPE R 1 B - ISOMETRIC VIEW (RESIDENTIAL. WITH BUFFER) For NOTES STD. PLAN 104.2 STD. PLAN - 104.3 CEMENT CONCRETE DRIVEWAY pV ppRF,D: Ir ENTRANCE - TYPE RIB L...�eJa�N�e_ 11/' SCALE. NTS ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 1 12 13"x24" PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC, INC. BCF SERIES MSBCF 1324-18 WITH 1.75" THICK DUCTILE IRON DIAMOND PLATE COVER EQUAL TO MID -STATES PLASTICS, INC. MSCBC-1324-R WITH READER LID AND 2" DRILLED HOLE FOR TOUCHREAD PIT LID (SEE DETAIL A -A) 9" MIN 12" MAX FINISH GRADE 711. Q w �> 36" MIN COVER O N 0 -1/2 NEW DUCTILE IRON WATERMAIN CITY PIPING z I IN UNIMPROVED RIGHT OF z J WAY INSTALL METER BOX AT J >- PROPERTY LINE WITH 12" >- w LONG COPPER TAILPIECE. w SIDEWALK 0 TOUCHREAD WATER METER TO BE PRIVATE PIPING SUPPLIED BY THE 12 Z "� FMW CITY <> TYPE "K" SOFT .00 / COPPER TUBING IF SERVICE LINE TO HOUSE IS 3/4" OR 1" TO BE INSTALLED IN THE FUTURE GALVANIZED INSTALL FORD C14-33 OR 44 FIPT PLUG x COMPRESSION COUPLING / Z- LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN COPPER COPPERSETTER FOR 5/8%3/4" METER: FORD SERVICE LINE TO METER. VBH72-15W-44-33G, OR McDONALD BRASS: 21-215WCQ033, OR MUELLER: 3/4-8-2470-2 WITH ANGLE BALL VALVE ON INLET AND SINGLE CHECK VALVE ON OUTLET CORPORATION STOP WITH BALL VALVE. FORD COPPERSETTER FOR 1" METER: FORD VBH72-15W-44-44G, OR TAPERED THREAD (CC). QUICK JOINT McDONALD BRASS: 21-415WCQQ44, OR MUELLER: 1-B-2470-2 (3/4" FB1000-3-0) OR AY MCDONALD 4701B BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON (1" FB1000-4-Q) OR AY MCDONALD 4701B INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET. ALL FITTINGS SHALL BE WITH QUICK JOINT. NOTE: ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUSH BE INSTALLED ON BOTH SIDES OF METER BOX. A— A DRILL 2" DIA. HOLE FOR AMR (AUTOMATIC METER READ) TOUCHREAD DEVICE L 4i 2-1/2" MIN. FROM NEAREST AND FRONT EDGE OF PIT LID TYPICAL RIB NOTE: THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE RIB. Y GtiT ° PUBLIC WORKS 34" AND 1" WATER SERVICE STD. PLAN - 320.1 �s DEPARTMENT �N �p NOVEMBER 2009 Know what's below. Call before you dig. VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 CITY OF RENTON DATUM Planning/Building/Public Works Dept. 0 L�J N� Lei LL R-420307 L' M IN COMPLIANCE WITH CITY OF RENTON STANDARDS W 2 DEVELOPMENT ENGINEERING c Ao*'U 0 Ar Brianne Bannwarth 02/07/2022 ' 00 I..L Q DATE: STRAIGHT ARROW HOMES 35TH ST SFRS 1127/2022 = OFFSITE IMPROVEMENTS FIELDBOOK C� PAGE: ---- DRAWING N0: R2.03 STANDARD DETAILS SHEET? of 7 (�