HomeMy WebLinkAboutR-399807INSIDE HOUSE PREFERRED CONFIGURATION s s 0 2 3 10 8 10 4 2 FLOW ITEM AMT 1 90' GALVANIZED STEEL ELBOW 4 EA. 2 3/4" PACKING JOINT COUPLING W/MALE IRON PIPE 2 EA. THREAD FOR COPPER PIPE SERVICE: FORD C84-33 OR EQUIVALENT FOR GALVANIZED PIPE SERVICE: FORD C85-33 OR EQUIVALENT 3 PRESSURE REDUCING VALVE W/STRAINER - 3/4• 1 EA. WITH UNION COUPLINGS AT INLET AND OUTLET, WILKINS 500 SERIES OR EQUAL (WITH INTERNAL BYPASS AND STRAINER) 4 3/4" CLOSE UNION - BRASS (M X F) 1 EA. 5 3/4" BRASS VALVE VARIABLE 6 12' STANDARD METER BOX W/SOLID COVER 1 EA, CONCRETE: 17 1/4 X 28 5/8 INSIDE DIMENSIONS, EQUAL TO FOC TITE METER SEAL CO_ +2 PLASTIC: 13 X 24 1 INSIDE DIMENSIONS, EQUAL TO BROOKS METER BOX 7 3/4" GALVANIZED STEEL PIPE, THREADED, LENGTH AS VARIABLE REQUIRED B 3/4" X 1/4• X 3/4• STD. BRASS TEE I EA. 9 1/4" PETCOCK (M X F) 1 EA. 10 3/4• BRASS NIPPLE VARIABLE ADJACENT TO WATER METER PROPERTY LINE SAWDUST 5 6 9 5 FILL 7 24" MIN 7 7 G. v 1 FROM 6• P A A L WATER METER 1 10 09 B 10 4 OFLOW 2 FUNCTION THE FUNCTION OF A PRESSURE REDUCING VALVE IS TO REDUCE HIGH-WATER PRESSURES IN THE SERVICE CONNECTION TO AN ACCEPTABLE RANGE OF 55 TO 75 PSI INSTALLATION OF A PRESSURE REDUCING VALVE IS REQUIRED WHERE THE SERVICE CONNECTION PRESSURE EXCEEDS 80 POUNDS PER SOUARE INCH IN ACCORDANCE TO THE UNIFORM PLUMBING CODE. INSTALLATION THE PRESSURE REDUCING VALVE SHALL BE LOCATED ON THE CUSTOMER'S PROPERTY "DOWNSTREAM" OF THE METER BOX. RESPONSIBIUTY FOR PROPER INSTALLATION, OPERATION, AND MAINTENANCE OF THE VALVE SHALL BE ASSUMED BY THE CUSTOMER. THREE POSSIBLE CONFIGURATIONS FOR INSTALLATION OF THE VALVE ARE SHOWN ABOVE_ A BUILDING DEPARTMENT PLUMBING PERMIT IS REQUIRED PRIOR TO INSTALLATION PUBLIC WORKS 3/4" & 1" INDIVIDUAL PRESSURE REDUCING STD. PLAN - 340.5 DEPARTMENT VALVE ASSEMBLY MAtiC1I 201[) � EX, SEWER MAIN PROPERTY UNE F LENGTH AS NEEDED) ? = I EWER STUOEin -1 I I FUTURE 4' SIDE SEWER OC--===_____�12"x 4" STUD MARKING POST PAINTED AIN TEE X G" TEE I 6" CAP J WHITE WITH THE WORD 'SEWER" STENCILED IN 3" HIGH BLACK LETTERS AND #6 WIRE WRAPPED AROUND THE STUD AND 3 EXTENDED TO THE TOP OF THE STUD. COUPLING (TYR) i I ' 6"X6'X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER I (EAST JORDAN IRON WORK5 PRODUCT NO. 00307502 OR APPROVED EQUAL, SPECIFY "SEVER" ON LID), I (5EE STD. PLAN 403.1 FOR INSTALLATION) I ____ -------------- ---- -T_-_J JM EAGLE THREADED CLEAN -OUT ADAPTER NUB -� & PLUG 6END AS (OR APPROVED EQUAL) REquIRED EXISTING SANITARY _ SEWER MAIN �-26X IN. SLOPE �\-FUTURE 4- SIDE SEWER 6" SEWER STUB 6"XB"XB" WYE FUTURE 6"x 4" REDUCER `SEWER MAIN SIZE X 13- TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNFCTONS TD FXISnNG SEVIER MAIN A. VIT im CLAY MAIN - CUT IN A NEW PVC "TEE" USING 'STRONG -BACK' FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B. CONCRETE MAIN - CUT IN A NEW PVC "TEE' USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED E4UAL). C. PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL). D. DUCTILE IRON MAIN - CORE -DRILLED WTH A ROMAC SADDLE (OR APPROVED EQUAL) E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED. 0S, 3000 PSI MIX /h`� `IN G CONCRETE ' �a BLOCKING T• 5 � M Z i __G_____27i MIN SCOPE L HORIZONTAL 6' TEE 6" MIN. SEWER SEWER MAIN MAIN CONCRETE BLOCKING ANGLE OF TEE AT MAIN BETWEEN 25' AND 45' TYPICAL SIDE SEWER NOTE; UNLESS OTHERWISE SHOWN ON PLAN, SIOE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5 LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. STANDARD SIDE SEWER STD. PLAN - 406.1 PUBLIC WORKS INSTALLATION AP VEo: DEPARTMENT (SEWER MAIN TO PROPERTY LINE) M1I4 MVila M Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • IssaQuah, WA 98027 • Phone: (425) 392-0250 • Fax: (425) 391-3055 Eastern Washington Division 407 Swiftwater Blvd. ■ Cle Elum, WA 98922 ■ Phone: (509) 674-7433 ■ Fax. (509) 674-7419 RECESSED Not to Scole n LIFT POCKET FRAMEIJ 3/4• LETTERING "SEWER" 2`0� DIAMETER 2'_D" SEWER (2) BOLT SOC. (ALLEN HEAD) 5/8" - 11 X 1,5 STAINLESS STEEL REF. PART #00081177 1-3j16" 10-1/2"-r 8" CLASS "B6" SANO OR ASPHALT EXPANDA L 1/4" 2-•1/4" BOLT DETAIL 45' (1 /6) BEND BEND 0. FOAM PIPE MATERIAL AS SPECIFIED BY THE ENGINEER NOTES! 1. 8" AND 6" CLEAN --OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC. No. 3698 (PRODUCT NO. 00359803) OR APPROVED EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. 2. IN UNIMPROVED AREAS, POUR A V-0" THICK, 2'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER, STD. PLAN - 403.1 PUBLIC WORKS I 8" OR 6" CLEANOUT DEPARTMENT FOR SANITARY SEWER MAIN CEMENT CONCRETE SIDEWALK AND RAMP SECTION A Department Transportation Road Services Division 2016 Design and King County Construction Standards 2 1 U,�)7ii7Ty NO. L 7S. FMFNTMq-I' aiys/T/O/y CID �C MATCH EXISTING OR PROPOSED SURFACE ASPHALT CONCRETE SHOULDER W (SEE NOTE 7) LIMITS OF PIPE ZONE 1 01? BEDDING MATERIAL FOR SANITARY SEWER PIPE O.D. OF PIPE (SEE NOTE 5) FOUNDATION LEVEL 5, Ir BEDDING FOR SANITARY SEWER PIPE OTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2, HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS. 5. PIPE ZONE MATERIAL SHALL BE PER SECTION 9--03.12(3)' OF THE STANDARD SPECdFICATIONS OR PEA GRAVEL. B. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. 7. TRENCH WIDTH SHALL 13E PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS, ,ate PUBLIC WORKS ❑EPARTMFNT NOTES: 1. SEE SEC. 3.02 FOR SIDEWALK WIDTHS. 2. SEE SECS. 2.02 AND 2.03 FOR PAVEMENT AND SHOULDER WIDTHS. 3. SHOULDER SHALL BE SURFACED AS REQUIRED BY SECS. 3.07 AND 4.01. PAVED SHOULDER SLOPE SHALL MATCH CROWN SLOPE OR 0.02 FT./FT. 4. SEE FIG. 3-001 FOR CURB AND SIDEWALK JOINTS. 5. THIS DETAIL APPLIES TO ROLLED AND VERTICAL CURB ROADWAYS. CEMENT CONCRETE SIDEWALK TRANSITION TO ASPHALT SHOULDER PER CITY OF RENTON COMMENTS PER CITY OF RENTON COMMENTS REVISION FIG. 3-014 STD. PLAN - 405 PIPE BEDDING FOR SANITARY SEWERS FIGURE C.2A.0 SCHEMATIC REPRESENTATION OF A 10-FOOT DISPERSION TRENCH CROSS- SECTION AND ROOF APPLICATION MAX20SLOpe � -� LEVEL OUTLET MAXX 15=PE 6" MIN. RIGID PERFORATED 18"MIN. PIPE, 4" MIN. DIA. 3/4" TO 1-1/2" WASHED 24" MIN, DRAIN ROCK TRENCH SECTION NTS 10-FOOT-LC NG DISPERSION TRENCH I EDGFOFUNDISTURBED I NATIVE VEGETATION I � � MIN. 100-FT--LONG NVFS --- SMALL CATCH BASIN --==_K---_-_--_---- I ' OR YARD DRAIN I 1 , I 50' SEPARATION BETWEEN 1 s 1,400 SO FT FORA 100-FT NVFS , FLOWPATH SEGMENTS, TRENCHES j 5 2.800 SO FT FOR A 200-FT NVFS .I r ; TYPE1 __==EFTATED cc❑ NATIVE VEGETATED _S CB--==,:FLOWPATHSEGMFNT=,== ' ----T---------------F-- I I 100 FEET MINIMUM_;,; 1 FOR A 100-FT NVFS 1 <-10,000SOFT , -_=_ =51S $LOPli:-. FOR A 200-FT NVFS t, zzz=v� -t-------------�_-� 1 5 I 1 • ' 50-FOOT-LONG ' PLAN VIEW OF ROOF MIN 6" DIA. DISPERSION TRENCH NTS RIGID PIPE WITH NOTCH EOARD SEE FIGUREC.2.1D 2017 City of Renton Surface Water Design Manual C-39 SURVEYED: SDM DESIGNED: NEM AAD 05117119 NEM DRAWN: LFM NEM 03129118 CHECKED: NEM BY DATE APPR APPROVED: CJA 12i1? 2016 TEE OF APPROPRIATE SIZE r ; tir SEE NOTE 6 '• =. :r =-... I V. . U - "RELINER" BRAND STAINLESS STEEL ADJUSTABLE CLAMPING BRACKETS OR APPROVED EQUAL 90' BEND 3/4 THE DIAMETER OF THE DOWNSTREAM PIPE N OTES: 1. SANITARY SEWER MANHOLE DROPS ARE ONLY TO BE USED UPON APPROVAL BY THE WASTEWATER UTILITY SECTION, 2. ALL PIPES AND FITTINGS SHALL BE SIMILAR SIZE AND MATERIAL AS INCOMING MAINLINE. 3. MINIMUM SIZE MANHOLE FOR INSIDE DROP CONNECTION SHALL BE 60" DIAMETER. 4. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR. KOR-N-SEAL BOOTS OR APPROVED EQUAL. 5. WITHIN A 60" DIAMETER MANHOLE, THE MAXIMUM ALLOWABLE DIAMETER OF THE INSIDE DROP PIPING IS 12". INSIDE DROPS EXCEEDING 12" IN DIAMETER OR MULTIPLE DROPS SHALL BE REVIEWED BY THE WASTEWATER UTILITY AND MAY REQUIRE A LARGER DIAMETER MANHOLE. 6. "RELINER" BRAND STAINLESS STEEL ADJUSTABLE CLAMPING BRACKETS OR APPROVED EQUAL SHALL BE INSTALLED WITHIN 6" OF BOTH BELL AND SPIGOT ENDS OF EACH DROP PIPE. IF DROP PIPE LENGTH EXCEEDS 5 FEET THEN CENTER STRAPS SHALL BE INSTALLED WITH A MAXIMUM SPACING OF 4 FEET ON CENTER. BRACKETS SHALL BE ATTACHED UTILIZING STAINLESS STEEL EXPANSION BOLTS, MIN. 2 EACH AT CONNECTION POINTS. PUBLIC WORKS DEPARTMENT RECORD DRAWING Know what's below. Call before you dig. SCALE: VERTICAL:• CITY 0 F 1 u_2Or HORIZONTAL::NAD AD 1983/183/1991 OR) RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY INSIDE DROP CONNECTION FOR SANITARY MANHOLE STD. PLAN - 402.2 RANDOM FILL 6" FILTER FABRIC 18" min 6" PERF PIPE 3,1 - 1 2 " WASHED ROCK 24" MIN. TRENCH X-SECTION slope to road drainage system x 10' el trench wl perf pipe PLAN VIEW OF ROOF PERFORATED PIPE CONNECTION DETAIL NTS R-399807 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q J DEVELOPMENT ENGINEERING a T swarlick 07/24/2019 C MA TVEYEV SHORT PLAT LUA17-000503 CONSTRUCTION DETAILS r- O DATE: 05117119 I FIELDBOOK: N/A PAGE: NIA DRAWING NO: 16645 Q SHEET: OF: 7 7