HomeMy WebLinkAbout28 - MaxiForce Collapsible Bollard - approvedTo:SUBMITTAL #28 - Collapsible Bollard DATE:1/20/2022 Attention:Michael Sippo PHONE: Project:Forest Terrace (Pulte Homes) 2611 Union Ave NE, Renton, WA 98059 We are enclosing: Submittal Application Supplier MaxiForce Collapsible Bollard Access Road Bollards MaxiForce Traffic Control Bollards (A) For approval or corrections - Return (B) For review and comment (C) Approved as corrected - Return (D) Approved - Work may proceed (E) Revise and resubmit - Work may proceed (F) Revise and resubmit - Work MAY NOT proceed ACTION REQUIRED ACTION REQD. Product 1 MCSW-SS3-EZ A City of Renton 1055 S. Grady Way Renton, WA 98057 ITEM #DESCRIPTION DEVELOPMENT ENGINEERING msippo 01/20/2022 11223344AABBCCDDMaxiForceâ„¢ Traffic Control Bollards7560 Main StreetSykesville, MD 21784410-552-9888 (phone) - 410-552-9939 (fax)www.maxiforcebollards.com - sales@maxiforcebollards.comScaleNAMCSW-SS3-EZ1 Of1 DO NOT SCALE DRAWINGSheetFile NameCSizeCreatedModel1Drawing Rev. PROPRIETARY AND CONFIDENTIAL THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF BLUE EMBER TECHNOLOGIES, LLC. ANY USE OF THIS DRAWING OR THE INFORMATION CONTAINED HEREIN FOR OTHER THAN THE PURPOSE FOR WHICH THIS DRAWING IS FURNISHED IS FORBIDDEN.11/2/2009Base WeightBollard Assy. WeightMCSW-SS3-EZ56 lbs 5 lbsMaxiForceâ„¢ Collapsible BollardStandard Body, Wrench Operated, Standard Style 3 Head, EZ Base- Low Maintenance / Durable steel construction- One year warranty / Protected by $1,000,000 in liability insurance- No complex assembly required in the field- Custom sizes, options, colors and finishes available upon request- Finish options available (add code to the end of the model number) - Powder coated (PC) - Powder coated with DRYZINC primer (PCZ) - Hot dip galvanized (G) - Hot dip galvanized & powder coated (GPC)- Reflective tape available upon requestAHJ approved in many cities / counties / campuses foruse in fire lanes per International Fire Code (IFC) 503Patented fire hydrant wrenchoperation works with any standardfire hydrant wrench by turning thenut 1/4 turn to unlock and lowerthe bollard. (1-3/8" nut standard)*Free standard hydrant wrenchincluded with each orderPatented break-awaydesign allows instant emergency access without a key. This unitcan be pushed over withthe bumper of a vehicle.6"32"Above Grade3 5/8"Clearance3"39 5/8"Overall Height4 1/4"ClearanceEZ Base may be cast in place(no tripping hazard)- or - installed in epoxy filled holes.SS3 Head7 5/8"Below GradeShallow installation depth isgreat for use in parking decks,over shallow utilities or rocks,in foundations or anywhereminimal ground penetrationis required.