SE 7 /4 OF THE N/W 7 /4, SEC. 10, TWP. 23 N., RGE. 5 E., W.M.
FIND 4"X4" CONC.
MON WITH
FIND 4"X4"
CONC. MON WITH 2" BRASS DISC LOCATED
7-21 -20 FIND 4"X4" CONC.
MON WITH
2" BRASS
DISC LOCATED
2" BRASS DISC LOCATED
7-21-ED
_
79 _ z
7-21-20
_
479.
7s
_ - -ST
9 s
L=1ss. oz S
89°51 03 E 130.00
Cc
0 i
CQ
FIND 4"X4" CONC. MON WITH
2"
o
BRASS DISC LOCATED 7-21-20
0
00LO
to
co
0
30' o
10
0
0
N89°51'03"W
178.00 BM
"A"
24'
1
CD
CD
o
o
Ln
/
PROJECT
U�
co
LO
1 0
w
SITE
w
w
/
o
00
Q
00
P
CD
/
0
z
o
W
1
N89°51'03"W
178.00
U
co
j
� I
Mo �
0
N FOUND MON IN CASE
1 1 /2" BRASS DISK
WITH PUNCH MARK CALC CTR OF
CITY OF RENTON #1848 SECTION NOT FND
00 N: 1 83691 .4502
E: 1 31 1 377.410 __
0 - -
I FOUND MON IN CASE
2" BRASS DISK WITH
PUNCH MARK
CITY OF RENTON #1849
N: 183615.5055
E: 1313987.638
HORIZONTAL CONTROL DIAGRAM.
1" = 60'
CONDITIONS OFAPPROVAL
0
I�
ILO
00 30' 0
0
THE HARDY SHORT PLAT, F/LE NO.. LUA21-000169, SHPL-A, AS DEPICTED /N EXHIBIT 2, IS APPROVED AND /S SUBJECT TO THE FOLLOWING
CONDITIONS.-
1. THE APPLICANT SHALL SUBMIT A REVISED SHORT PLAT LA POUT W/TH THE C/V/L CONSTRUCAON PERMIT APPL/CAT/ON THAT PROVIDES TRACT A
WITH A W/OTH OF 24.5 FEET THAT WOULD INCLUDE 16-FOOT W/DE PAINED DRIVf'AA Y, A 6-INCH INERT/CAL CURB, AND 8-FOOT WIDE PLANTER
STRIP AND TO PROVIDE LOT 2 W/TH A WIDTH OF 61 FEET. THE REVISED SHORT PLAT LA POUT SHALL BE REVIEWED AND APPROVED BY THE
CURRENT PLANNING PROJECT MANAGER PR/OR TO PERM/T ISSUANCE.
2. A DENOL/T/ON PERMIT SHALL BE OBTAINED AND THE REMOVAL OF EX/SANG STRUC7URES AND ALL REWIRED INSPECTORS BE COMPLETED PR/OR
TO THE RECORDING OF THE SHORT PLAT.
3. A DETAILED LANDSCAPE PLAN SHALL BE PROVIDED AT THE AUE OF CONSTRUCT/ON PERM/T REVIEW. THE DETAILED LANDSCAPE PLAN SHALL
INCLUDE AN 8-FOOT WIDE LANDSCAPE STRIP WITH TREES, SHRUBS AND GROUNDCOW_R BETWEEN THE SHARED DRIVf'HA Y AND SOUTH PROPERTY
LINE ALONG THE FULL LENGTH OF THE SHARED DR/VEW,4 Y TRACT (TRACT A) THE LANDSCAPE STRIP BETWEEN THE SHARED DR/VEWA Y AND
SOUTH PROPERTY LINE SHALL BE SEPARA TED WITH A VERACAL CURB. A TOTAL OF 2 TREES SHALL BE PROVIDED W/TH/N THE FRONT YARD OF
LOT 1. STREET TREES SHALL BE SELECTED FROM THE CITYS APPROVED STREET LIST AND SPACING GUIDELINES OR OTHERWISE APPROVED BY THE
CITY ARBOR/ST. THE DETAILED LANDSCAPE PLAN SHALL BE SUBMITTED WITH THE CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND
APPROVAL.
4. A FINAL TREE RETENAON PLAN SHALL BE SUBMITTED AT THE AME OF CONSTRUCAON PERMIT REVIEW. THE FINAL TREE RETENAON PLAN SHALL
INCLUDE TREE PROTECTION MEASURES, FOR TREES TO BE RETAINED ON AND OFF SITE, THE BE IMPLEMENTED DURING CONSTRUCAON OF THE
SHORT PLAT AND THE FUTURE HOME IN ACCORDANCE WITH RUC 4-4-130H.9. THE FINAL TREE PROTECTON PLAN SHALL BE SUBMITTED TO THE
CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND APPROVAL PR/OR TO PERMIT ISSUANCE.
5. AN ARBOR/ST SHALL BE PRESENT ONS/TE DURING THE INS TALLA AON OF THE STORM L/NE TO ENSURE PRO TECTON OF ON AND OFF S/TE TREES
DURING CONSTRUCAON.
6. DR/VEWA Y ACCESS FOR LOT 2 SHALL BE PROVIDED OFF OF THE SHARED DRIVEWA Y TRACT (TRACT A) A NOTE TO THIS EFFECT SHALL BE SHOWN
ON THE FINAL SHORT PLAT SUBMITTAL TO BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER AND RECORDED ON THE
FACE OF THE FINAL SHORT PLA T.
7. A SHARED MAINTENANCE AGREEMENT SHALL BE ESTABL/SHED FOR THE MAINTENANCE OF COMMON /UPROVEUENTS WITH/N THE SUBD/V/S/ON,
INCLUDING, BUT NOT L/U/TED TO THE STORMWATER FACILITY AND SHARED DRIVEWAY TRACT (TRACT A) A NOTE TO THIS EFFECT SHALL BE
RECORDED ON THE FACE OF THE SHORT PLAT.
8. BOTH HOMES SHALL BE CONSTRUCTED WITH APPROVED FIRE SPRINKLER SYSTEMS. A NOTE TO THIS EFFECT SHALL BE SHOWN ON THE FINAL
SHORT PLAT SUBMITTAL TO SE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER AND RECORDED ON THE FACE OF THE
FINAL SHORT PLAT.
9. THE FRONT ENTRY FOR THE NEW HOME TO BE CONSTRUCTED ON PROPOSED LOT 2 SHALL BE REQUIRED TO FACE TO THE EAST TO F/ELD
A VE NE.
C
RT
ClVIL CONSTRUCT/ON PERM/T
r'/TY nF RFIV TnA1 W,4 SH/lVn TnIV
RECORD DRA WINGS
SITE INFORMA T/ON
ADDRESS.• 857 FIELD A Vf- NE, RENTON WA 98059
PARCEL NO. 1437650040
PROPERTY OWNER- ALEXANDER WENZL
SITE INFORMA TION
✓UR/SD/CT/ON.-
PARCEL NUMBERS -
GROSS SITE AREA:
EX/STING ZONING:
VOLUME
PROPOSED NUMBER OF LOTS
PROPOSED SQUARE FOOTAGE /N
EACH LOT
SQUARE FOOTAGE OF LAND /N STREET
AND OPEN SPACE
SQUARE FOOTAGE OF LAND /N
PUBL/CL Y DEDICATED STREET
SQUARE FOOTAGE OF LAND /N
PR/VA TE ACCESS EASEMENT/TRACT
DENSITY PROPOSED AND DENSITY
PERMITTED BY CODE
CITY OF RENTON
14.37650040
15,130 SF (0.35 AC)
R-8
CUT 90 CY
FILL J40 CY
NET 250 CY (CUT)
2
LOT 1 7,565 SF
LOT 2 5,264 SF
2,277 SF
170 SF
2,132 SF
GROSS DENSITY 5.76 DU/AC (2 LOTS/0.347 AC)
NET DENSITY 5.86 DU/AC (2 LOTS/0.341 AC)
BASIS OF BEARINGS
BASIS OF BEARINGS /S NAD83191 (CITY OF RENTON)
NA VD 88
LEGAL DESCRIPTION
LOT 4, CASTLEWOOD RANCHETTES, ACCORDING TO THE PLAT THEREFORE RECORDED /N
VOLUME 129 OF PLATS, PAGE 13, IN KING COUNTY, WASH/NGTON
BENCHMARK
SOURCE • GPS OBSERVA AON NORTH ZONE
DA TUM.• NA VD88
C/TY OF RENTON CONTROL POINT 1848 1 1/2" BRASS DISC W/TH PUNCH MARK ON A 4'X4"
CONCRETE POST DOWN 0.4' IN CASE AT THE CONSTRUCTED INTERSECT/ON OF NE 87H COURT AND
UN/ON A Vf-NUE NE
BENCHMARK 'A "
SET PK 13.0'f/- EAST OF NORTHEAST CORNER OF SUBJECT PROPERTY.
ELEVA T/ON = 472.18 FEET
BENCHMARK 19"'
SET PK 8.0'f/- NORTH AND 14.0'4/- EAST OF THE SOUTHEAST CORNER OF SUBJECT PROPERTY.
ELEVA AON = 471.81 FEET
SURVEYOR'S NOTES
1. INS TRUMENTA T/ON FOR THIS SURVf Y WAS A TOPCON 1 SECOND TOTAL STA T/ON AND A
SPECTRA SP80 DPS UNIT. PROCEDURES USED /N THIS SURVEY WERE FIELD TRAVERSE,
MEETING OR EXCEED/NG STANDARDS SET BY HA 332-130-090.
2. THE /NFORUA AON DEPICTED ON THIS MAP REPRESENTS THE RESUL TS OF A SURVf-Y MADE
IN ✓UL Y, 2020, AND SHOWS THE GENERAL CONDITION EXISTING AT THAT AUE.
3. CONTOURS DERtVf-D FROM FIELD OBSERVATIONS.
4. THE UNDERGROUND UAL/AES SHOWN HERON ARE BASED UPON PA/NTUARKS AND F/ELD
OBSERVATIONS AND ARE NOT GUARANTEED TO BE CORRECT, NOR ALL /NCLUSIVf. ALL
UAL/AES MUST BE VfR/F/ED PR/OR TO CONSTRUCT/ON. CALL 1- 800- 424 - 5555 FOR
UAL/TY LOCATORS.
DESIGN STANDARDS
M/N LOT AREA:
5, 000 SF (ONE LOT MA Y BE 4,500 SF)
M/N LOT W/D171-
50' 60' CORNER
M/N LOT D6,0N.-
80'
FRONT SETBACK.•
20' (SECONDARY FRONT YARD 15)
SIDE YARD SETBACK-
5'
REAR YARD SETBACK-
20'
MAX HEIGHT
30'
MAX IMPERVIOUS-
659
MAX BLDG. COVERAGE.'
509
UTILITY CONTACTS
ELECTRICITY/NATURAL GAS.•
PUGET SOUND ENERGY
P 0 BOX 97034
BELLEV!Jf,, WASHINGTON 98009
1-800-.321-7890
WATER.•
KING COUNTY WA TER D/STR/CT 190
15606 SE 128TH STREET
RENTON, WASHINGTON 98059
425-255-9600
CABLE
COUCAST
14870 NE 95TH STREET
REDMOND, WASHINGTON 98052
1-877-824-2288
TESC SUPERVISOR
T.B.D.
SHEET INDEX
C/VlL PLANS.•
C1. 01
ATLE SHEET / HORIZONTAL & VERACAL CONTROL PLAN
C1.02
SITE & COMPOSITE UTILITY PLAN
C2.01
TEMPORARY EROSION & SEDIMENT CONTROL PLAN
C2.31
TEMPORARY EROSION & SEDIMENT CONTROL DETAILS & NOTES
C3 01
ROAD & GRADING PLAN
C3.31
ROAD DETAILS
C4.01
UALITY PLAN
C4.21
UALITY PLAN & PROFILE
C4.22
UALITY PROFILE
C4.31
DETENAON VAULT DETAILS
C4.32
UALITY DETAILS
C4.33
UALITY DETAILS
LANDSCAPE PLANS.•
L 1.01
TREE RETENAON PLAN
L2.01
LANDSCAPE PLAN
L2.31
LANDSCAPE DETAILS AND NOTES
PERMIT NUMBER
CIVIL CONSTRUCAON.• C21-004477
4-26-2023
SURVEYED: XXX SCALE:
DESIGNED: SHY
DRAWN: SES
ONE INCH
CHECKED: SHY AT FULL SCALE
IF NOT ONE INCH
NO. REVISION BY DATE AP P R APPROVED: SHY
SCALE ACCORDINGLY
E 10TH S
zz
J
CL
J J
D >
o o
z
w
Z
Q
7
O
_
NE 10TH ST
w
z
E 9TH ST
U
E g� ST
o
P�NE.71T;
NE 8TH P
NE 8THSTSIT
w
J
o
a
w_
o
m
NE 7TH P
J
D
O
Uj
=
z
y
v
a
z
>
r
m
y
NE 6TH
�
v
O
VICINITY MAP
NOT TO SCALE
STORM LEGEND
STORM PIPE
® STORM STRUCTURE (W/INLET PROTECTON)
STORM SERVICE
STORM PIPE FLOW ARROW
STORM VAUL T EXTERIOR WALL
- - - - - - - STORM VAULT INTERIOR WALL
STORM VAUL T WATER LEVEL
STORM EASEMENT
EXISTNG STORM PIPE
EXISTNG STORM PROFILE
SEWER LEGEND
0 SPIER PIPE
SEVER STRUCTURE
SEVER SERVICE
SEIER PIPE FLOW ARROW
SEHER EASEMENT
EXISTNG SEHER PIPE
EXISTNG SEHER PIPE PROFILE
WA TER LEGEND
T TT WATER METER
- - WATER EASEMENT
EXIS17NG WATER PIPE
EXISTNG WATER PROFILE
ROAD LEGEND
CURB LINES
GUTTER LINES
ASPHAL T ROAD
0
ASPHAL T ROAD PATTERN
SIDEWALK
SIDEWALK PATTERN
DRII/_WA Y
DRII/_WA Y PATTERN
GRA I/EL
GRA I/EL PATTERN
ADA RAMP
ADA RAMP PATTERN
ROAD MARKINGS
- -
SAWCUT
01/ERLAY
- - - -
ROAD EASEMENT
SURFACE LEGEND
190
EXISTNG GROUND SURFACE TEXT (CONTOUR LABELS)
EXISTNG GROUND CONTOUR UA✓OR
EXISTNG GROUND CONTOUR UINOR
FINISH GRADE SURFACE TEXT (CONTOUR LABELS)
FINISH GRADE CONTOUR UA✓OR
FINISH GRADE CONTOUR UINOR
EROSION CONTROL LEGEND
CLEARING LIMITS LINE
CLEARING LIMITS LINE
xxx- SILT FENCE
TREE RETENAON FENCE
- 0- 0- 0- CONSTRUCAON FENCE
PROJECT NO. 21019
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
�zw�
DESIGN SURVEYING
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
com
HORIZV ONTAL: NAD 1983/1991 CITY OF
RENTON
DATUM
Planning/Building/Public Works Dept.
S-419301
RECORD DRAWING R-419301
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TITLE SHEET/HORIZONTAL &
VERTICAL CONTROL PLAN
NOV 2021
PAGE:
Cl. Ol
T: ' OF: 15
O
O
O
1
N
Cx
CL
I
N
V
cn I NE r 0:— 3 9 . (-0 2�/ —
1 \
I 1
O 2» II 00
° I 1 1
D I I 1 11
0 _ �avc
SD-
:4 v °
v
X__// X
/ SDMH /
RIM=459i2'6
X \ / / NV. 8"(-I)-456.71
\ N�.12 (E)=456.51 /
`—
1 -�NV.6"(S)-456.44 /
/ NV.12"(W)=456.31 /
I
I I I
/ TREE TO BE PUGET POWER ESM'T REC. I
I I NO. 8404060488 COMMUNICATION o
RETAINED (TYP)
/ PUGET POWER ESM'T REC. NO. ESM'T REC. NO. 8405040925
8404060488 DRAINAGE & UTILITY
X ESM'T REC. NO. 8411060415 L/M/TS OF S/LT FENCE PER \
i \ DISTURBANCE COR STD PLAN
\ �`, 214.00 I
(f 15, 718 SF) o
---� —�---- —---------J
N89°51'03"W 178.00
I T
/I � � . 1 —x x —x —x — 5��— x x —x —x x —x —x —x — x 2� ..-----------
6' WOOD FENCE ; ` - - - - -
0.5' S & 0.7' E I iI 3D FENCE WOOD FENCE v BM A'
2 \ / 1 EX/STING STRUCTURE
//� TO BE REMOI/ED D ) v / a
5 DRAINAGE & UTILITY \ \ / 1� / / • m , / /
ESM'T REC. NO. 8411
A
TREE PROTECT/ON
FENCE SEE DETAIL EX/STING WOOD n4.7'
I � \ � � ON SHEET C2.31 � STAIRS TO BE / I v \
Ii I REMOVED 1 \ I
/
1 I I SE9TlC TANK & DRAIN FIELD TO BE CONC. WA F K
REMOVED PER KING COUNTY
I I l /DEPARTMENT OF HEALTH STANDARDS l / 2 EXISTING HAND o
5,264f SF 1 RAI �
J 00
10\ I I I I // I HOUSE 1 \
I WOICD STAIRS / �� � \
1 472-,' LLJ a
\� GARAGE FF=470.200
° L�
04 ly
MAIN FF=475.2 0 ;
\ CD v
ROOF PEAK=492.2
I — 7 �65f SF I o
O ---
0� I ; �I<\ I �I \ -- I \ CONCRETE WALK &HAND 1 I 00 o
p I I I I v 1 -T A\--RAII —
w RD SF I
v �>
10/ I ' I 1 / STAGING AREA I I I I I
TO BE 00
VED (TYP) CD
e
� � � � CONC. PAV R � � � � � • ' I
°
�Z / \ WAFKWA I 1 I I
-
------------------------------------ ------ U-.,o� o� �� ww
I
I
/ ,/ \ �� o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ----------------------------------
o 0 0 0 0 0 0 0 0 0 0 0 0 0 0
oil\ 1---------------- ` M IB
I I
6' WOOD EENCE-_ i�7��A� INKNE -- -------------------- ---�- - - - - - - - - �� ------ -- ��j
4' CHAIN LINK FENCE — o I — — — — — — — — — — — — — —
00 0. 2' (E) — N89.51'03"W 178.00 . - ----�---
---- ----
�' 4' CHAIN LINK
PUGET POWER ESM'T REC. N0. SET LEAD &
0.4' N CONSTRUCT/ON ENTRANCE 1
o O 8404060488 DRAINAGE & UTILITY TA
N i ESM'T REC. NO. 8411060415 PER COR STD PLAN 215.10
I
N
SCALE: 1" = 10'
0 5 10 20
"O!!�
CATCH BASIN
INSERT PER COR
STD PLAN 216.30
(TYP)
% GCB
RIM=471.88
1 INV. 12"(N)-470.42
INV. 12"(S)-470.36
a_
Z
W �
EXISTING ASPHAL T DRIVf-WA Y
TO BE USED FOR TEMPORARY
CONSTRUCTION ENTRANCE
LOT 3 SOUTH EDGE i,
MOW CURB 0.1' (S) I
j
R RDbRA wING R-4 7 9303
PROJECT NO. 21019 IN COMPLIANCE WITH CITY OF RENTON STANDARDS
\,ZDEKO
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
•�
PLANNING
a,
o'•• P 41846
DESIGN SURVEYING
N
�PONAL ENVY
0
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
N
4-26-2023
Q
SURVEYED:
XXX
SCALE:
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
CITY 0 F
DESIGNED: SHM
RENT 0 N
U
DRAWN:
O
SES
ONE INCH
DATU M
CHECKED:
SHY
AT FULL SCALE
Planning/Building/Public Works Dept.
IF NOT ONE INCH
NO.
REVISION
BY
DATE
AP P R
APPROVED: SHM
SCALE ACCORDINGLY
TEMPORARY EROSION &
SEDIMENT CONTROL PLAN
Nov 2021
FIELDBOOK:
PAGE:
DRAWING NO:
C2. Ol
SHEET: j OF: 15
�0
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
DocuSign Envelope ID: 6EECF5B6-602A4E4A-B436-A317AA638878
DocuSign Envelope ID: 6EECF5B6-602A4E4A-B436-A317AA638878
Ful
EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES:
THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON THE
LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT
APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC
ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES.
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY
REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR.
2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL
PERMIT, IF IT IS REQUIRED FOR THE PROJECT, THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY
ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT.
3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION
COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS.
4. THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS
PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF
RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE
BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF
CONSTRUCTION.
5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT.
ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT
CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL
BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING
WATERS OF THE STATE.
6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE
TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE
WASHOUT AREAS.
7. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF
SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL
SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER
CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION,
MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT.
8. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY.
9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION
PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE
COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE
APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM
REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM.
10. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS,
CHANNELS, OR STORMWATER FACILITIES.
11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL.
12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1 ST
THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED
ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM.
13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1 ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY.
14. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS.
15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT.
INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY.
16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM
DRAIN INLETS DOWNSLOPE AND WITHIN 5D0 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED
TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING
CONDITION.
17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 213 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE
CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM.
18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL
PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE
TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT
FACILITY.
19. AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES OR ON -SITE BMPS (AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT,
ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION.
20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR
SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON.
AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW.
21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE,
ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE BMPS SHALL BE RESTORED TO THEIR FULLY
FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT MINIMUM,
DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH
WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST.
22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS
RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF
ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 268.00
,} IL PUBLIC WORKS EROSION AND SEDIMENT CONTROL STANDARD PLAN NOTES PPR °.
DEPARTMENT GAZ 9/28/2018 1
Nbk" k,Ad ,t, ro DATE
CONSTRUCT/ON SEQUENCE
1. SCHEDULE A PR'CONS TRUCTION CONFERENCE WITH THE CITY DEVELOPMENT ENGINEER. ONCE THE
MEETING /S HELD THE C1WL CONSTRUCTION PERMIT W/LL BE ISSUED.
2. FLAG THE LIMITS OF CLEARING, TREES TO BE SAVED AND INSTALL PROTECTIVE SILT FENCING WHERE
INDICATED.
3. POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR.
4. CONSTRUCT THE TEMPORARY ROCK -LINED CONSTRUCTION ENTRANCE.
5. CONSTRUCT THE SEDIMENT VAUL T, CONTROL STRUCTURE AND DOWNSTREAM CONVEYANCE SYSTEM.
6. ROUGH GRAD THE SITE AND DIRECT CONSTRUCTION RUNOFF TO THE VAUL T"
7. CONSTRUCT THE REMAINING STORM DRAINAGE FACILITIES PER THE ROAD & STORM DRAINAGE PLANS.
PROTECT THESE FACILITIES FROM DAMAGE AND SILTATION DURING CONSTRUCTION. INSTALL INLET
PROTECTION.
8. CONSTRUCT THE SEWER & WATER SERVICES PER THE APPROVED PLANS. PROTECT THESE
FACILITIES FROM DAMAGE DURING ON -GOING CONSTRUCTION.
9. CONSTRUCT THE REMAINING UNDERGROUND UTILITIES.
10. CONSTRUCT FRONTAGE IMPROVMENTS
11. HYDROSEED ANY REUA/N/NG DISTURBED SURFACES. REMOVE ALL TEMPORARY FACILITIES. PUMP
ANY COLLECTED DEBRIS FROM STORM DRAINAGE SYSTEM.
:45 An
2"x2" 14 GAUGE WIRE, OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
FILTER FABRIC
2' MIN.
I� 6' MAX. �l
SPACING MAY BE INCREASED
8' IF WIRE BACKING IS USED
I
I 711,
I4"x4" MIN. TRENCH
12"MITO
I
1POST
BACKFILL TRENCH WITH NATIVE SOI
OR 3/4" TO 1-1/2" WASHED GRAVEL
2"x4"
WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.)
NOTES:
1. CONDITIONS OF USE
1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED
FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE.
AOS (ASTM D4751)
30-100 SIEVE SIZE (0.60-0.15mm) FOR SILT FILM
50-100 SIEVE SIZE (0.30-0.15mm) FOR OTHER FABRICS
WATER PERMITTIVITY (ASTM D4491)
0.02 SEC'S MINIMUM
GRAB TENSILE STRENGTH (ASTM D4632)
180 LBS. MIN. FOR EXTRA STRENGTH FABRIC
100 LBS. MIN. FOR STANDARD STRENGTH FABRIC
GRAB TENSILE ELONGATION (ASTM D4632)
30% MAX. (WOVEN)
ULTRAVIOLET RESISTANCE (ASTM D4355)
70% MIN.
2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED
FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE.
2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 21HA V
2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND
SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE.
2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE.
3. MAINTENANCE STANDARDS
3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY.
3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING
CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT.
3.4. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH.
3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
"
Rq STD. PLAN - 214.00
PUBLIC WORKS SILT FENCE [11ROVED:
9/28/2018 1
PRDEPARTMENT GAZ
Public m Adm DATE
:45 AIN
5" MAX.
DRAINAGE GRATE TRIM
GRATE FRAME _
C- OVERFLOW BYPASS
BELOW INLET GRATE DEVICE
SEDIMENT AND DEBRIS
,A
FILTERED
WATER
SECTION VIEW
DRAINAGE GRATE
(RECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM (TYP.)
J
OVERFLOW BYPASS (TYP.)
BELOW INLET GRATE DEVICE
ISOMETRIC VIEW
NOTES:
1. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR
CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP.
2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM.
3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE.
4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE.
5. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS).
6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL.
7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15).
S. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE
STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 216.30
•�" PUBLIC WORKS APPR ED:
'"` DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 1
vlbogv Public Work,Adm iso-amr DATE
TREE PROTECT/ON MEASURES DURING CONSTRUCT/ON
PROTECTION MEASURES /N THIS SECTION SHALL APPL Y FOR ALL TRESS THAT ARE TO BE RETAINED ON
SITE AND OFF SITE. OFF SITE TREES CONTAINING DRIP LINES THAT ENCROACH ONTO THE SITE UNDER
CONSTRUCTION SHALL BE CONSIDERED PROTECTED TREES UNLESS IT /5 DETERMINED THE ABUTTING
PROPERTY OWNER /S /N COMPLIANCE WITH SUBSECTION C OF THIS SECTION, ALLOWED TREE REMOVAL
ACTIVITIES. ALL OF THE FOLLOWING TREE PROTECTION MEASURES SHALL APPL Y"
A. CONSTRUCTION STORAGE PROHIBITED: THE APPLICANT MAY NOT FILL, EXCAVATE, STACK OR STORE
ANY EQUIPMENT, DISPOSE OF ANY MATERIALS, SUPPLIES OR FLUIDS, OPERATE ANY EQUIPMENT,
INSTALL IMPERVIOUS SURFACES, OR COMPACT THE EARTH /N ANY WA Y WITHIN THE AREA DEFINED
BY THE DRIP L/NE OF ANY TREE TO BE RETAINED.
B. FENCED PROTECTION AREA REQUIRED.- PR/OR TO DEVELOPMENT ACPWRES, THE APPLICANT SHALL
ERECT AND MAINTAIN SIX --FOOT (6) HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND
THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING THE TREE EQUAL TO
ONE AND ONE QUARTER FEET (1-1/4) FOR EVERY ONE INCH (1') OF TRUNK CALIPER, WHICHEVER
/5 GREATER, OR ALON THE PER/METER OF A TREE PROTECTION TRACT. PLACARDS SHALL BE
PLACED ON FENCING EVERY FIFTY FEET (50)IND/CA77NG THE WORDS, 'NO TRESPASSING -
PROTECTED TREES" OR ON EACH SIDE OF THE FENCING IF LESS THAN FIFTY FEET (50) SITE
ACCESS TO INDIVVbALL Y PROTECTED TREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED.
INDIVIDUAL TREES SHALL BE FENCED ON FOUR (4) S/DES. IN ADDITION, THE APPLICANT SHALL
PROVIDE SUPERV/S/ON WHENEVER EQUIPMENT OR TRUCKS ARE MOVING NEAR TREES.
C" PROTECTION FROM GRADE CHANGES- IF THE GRADE LEVEL ADJOINING TO A TREE TO BE RETAINED
/5 TO BE RAISED THE APPLICANT SHALL CONSTRUCT A DRY ROCK WALL OR ROCK WELL AROUND
THE TREE. THE DIAMETER OF THIS WALL OR WELL MUST BE EQUAL TO THE TREES DRIP LINE.
D" IMPERVIOUS SURFACES PROH/SITED WITHIN THE DRIP LINE.• THE APPL/CANT MA Y NOT INSTALL
IMPERVIOUS SURFACE MA TER/AL WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE
RETAINED, UNLESS OTHERWISE APPROVED BY THE CITY. (ORD. 5958, 12-9-2019)
E. RESTRICTIONS ON GRADING WITHIN THE DRIP LINES OF RETAINED TREES- THE GRADE LEVEL AROUND
ANY TREE TO BE RETAINED MAY NOT BE LOWERED WITHIN THE GREATER OF THE FOLLOW/NG AREAS -
TOONE AND ONE THE AREA /NED BYHALF FEE (-112) IN DIAMETER F TREE,E DRIP LINE Of - THE EA CH ONE INCH (1') OFAN AREA D THE TREE TREE CALIPER.
LARGER TREE PROTECTION ZONE BASED ON TREE SIZE, SPECIES, SOIL, OR OTHER CONDITIONS MA Y
BE REQU/RED. (ORD. 5676, 12-3-2012)
F. MULCH LA YER REQUIRED. ALL AREAS WITHIN THE REQUIRED FENC/NG SHALL BE COVERED
COMPLETEL Y AND EVENL Y WITH A MIN/MUM OF THREE INCHES (3) OF BARK MULCH PR/OR TO
INSTALLATION OF THE PROTECTIVE FENC/NG. EXCEPTIONS MAY BE APPROVED If THE MULCH WILL
ADVERSELY AFFECT PROTECTED GROUND COVER PLANTS. (ORD. 5676, 12-3--2012)
G" MONITORING REQUIRED DURING CONSTRUCTION. THE APPLICANT SHALL RETAIN A CERTIFIED
ARBOR/ST OR LICENSED LANDSCAPE ARCHITECT TO ENSURE TREES ARE PROTECTED FROM
DEI/ELOPMENT ACTII/lTIES AND/OR TO PRUNE BRANCHES AND ROOTS, FERTILIZE, AND WATER AS
APPROPRIATE FOR ANY TREES AND GROUND COVER THAT ARE TO BE RETAINED.
H" AL TERNA T VE PROTECT/ON.• ALTERNATIVE SAFEGUARDS UA Y BE USED /F DETERMINED TO PROVIDE
EQUAL OR GREATER TREE PROTECTION.
:45 AP
THE APPLICANT SHALL ERECT AND MAINTAIN A SIX-FOOT (6) HIGH CHAIN
LINK TEMPORARY CONSTRUCT/ON FENCING AROUND THE DRIP LINES OF ALL
RETAINED TREES OR A T A D/STANCE SURROUNDING THE TREE EQUAL TO
ONE AND ONE -QUARTER FEET (1-1/4) FOR EVERY ONE INCH (1') OF
TRUNK CALIPER, WHICHEVER /S GREATER, OR ALONG THE PER/METER OF A
TREE PROTECTION TRACT. PLACARDS SHALL BE PLACED ON FENCING
EWRY FIFTY FEET (50) INDICATING THE WORDS, WO TRESPASSING -
PROTECTED TREES. " OR ON EACH 50f- OF THE FENCING /F LESS THAN
FIFTY FEET (50) SITE ACCESS TO ND/V/DUALL Y PROTECTED TREES OR
GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDN/DUAL TREES
SHALL BE FENCED ON FOUR (4) S/DES. IN ADDITION, THE APPLICANT SHALL
PROVIDE SUPERV/S/ON WHENEVER EQUIPMENT OR TRUCKS ARE MOVING
NEAR TREES.
NOTE-
1. MIN/MUM SIX (6) FOOT HIGH TEMPORARY CHA/NL/NK FENCE SHALL BE PLACED A,
FROM TREE DR/PL/NE OR DES/GNA TED L/M/T OF DISTURBANCE OF THE TREE TO B,
SA VED. FENCE SHALL COMPLETEL Y ENCIRCLE TREES). INSTALL FENCE POSTS US
PIER BLOCK ONLY MODIFICATIONS TO FENCING MA TER/AL AND LOCATION MUST B
APPROVED BY PLANNING OFF/C/AL.
2 TREATMENT OF EXPOSED ROOTS DURING CONSTRUCTION. FOR ROOTS OVER ONE (
INCH DIAMETER DAMAGED DURING CONSTRUCTION, MAKE A CLEAN STRAIGHT CU7
REMOVE THE DAMAGED PORTION OF ROOT. ALL EXPOSED ROOTS SHALL BE
TEMPORARIL Y COVERED WITH DAMP BURLAP TO PREVENT DRY/NG, AND COVERED
SOIL AS SOON AS POSSIBLE.
J. NO STOCKPILING OF MATERIALS, VEHICULAR TRAFFIC, OR STORAGE OF EQU/PMENi w
MACH/VERY SHALL BE ALLOWED W/TH/N THE L/M/T OF THE FENC/NG. FENC/NG SHALL
NOT BE MOVED OR REMOVED UNLESS APPROVED BY THE CITY PLANNING OFFICIAL.
WORK W 171IN THE PROTECT/ON Ff -NCf SHALL BE DONE MANUALL Y UNDER THE TREE DRIPLINE
SUPERVISION OF AN ON -SITE ARBOR/ST AND W/TH PR/OR APPROVAL BY THE CITY
PLANNING OFFICIAL.
4. ALL AREAS WITHIN THE REQU/RED FENCING SHALL BE COI/ERED COMPLETE,• Y AND
EVEAL Y WITH A MIN/MUM OF THREE (3) OF BARK MULCH PR/OR TO INSTALLATION OF
THE PROTECTIVE FENCING./ TREE PROTECT/ON FENCING
EX�SS\NO�,OPO
INSTALL DRIVEWAY CULVERT IF THERE
IS A ROADSIDE DITCH PRESENT, AS
PER CITY ROAD STANDARDS
DRIVEWAYS SHALL BE PAVED TO THE EDGE
OF R-O-W PRIOR TO INSTALLATION OF THE
CONSTRUCTION ENTRANCE TO AVOID
DAMAGING OF THE ROADWAY
IT IS RECOMMENDED THAT THE
ENTRANCE BE CROWNED SO THAT
RUNOFF DRAINS OFF THE PAD
12" MIN. THICKNESS
PROVIDE FULL WIDTH OF
NOTES INGRESSIEGRESS AREA
1. CONDITION OF USE
1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON
PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE.
GRABTENSILE STREBNGTH (ASTM D4751)
1200 PSI MIN.
GRABTENSILE ELONGATION (ASTM D4632)
30% MAX.
MULLEN BURSTSTRENGTH (ASTM D3786-80A)
1400 PSI MIN.
AOS (ASTM D4751)
20-45 (U.S. STAN DARD SIEVE SIZE)
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN ARES THAT WILL BOT BE USED
FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY
AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO
PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT.
2.2. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE.
2.3. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY
INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE.
3. MAINTENANCE STANDARDS
3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS.
3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE
STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE
ENTRANCE, OR THE INSTALLATION OF THE WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH
CRUSHED ROCK, AND WASHED WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY
SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET,
EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT NECESSARY TO WASH THE STREETS, A
SMALL SUMP MUST BE CONDUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND
DISCHARGED APPROPRIATELY.
3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY.
3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE
INSTALLED TO CONTROL TRAFFIC.
titY 0 STD. PLAN - 215.10
* PUBLIC WORKS STABILIZED
$ DEPARTMENT CONSTRUCTION ENTRANCE
MARCH 2O08
4-26-2023
SURVEYED: XXX SCALE:
DESIGNED: SHY
DRAWN: SES
ONE INCH
CHECKED: SHY AT FULL SCALE
IF NOT ONE INCH
NO. REVISION BY DATE APPR APPROVED: SHY
SCALE ACCORDINGLY
"T EX/STING TREE
CONTINUOUS CHAINLINK
FENCING
POSTS AT MAX. 8' 0. C"
NO SCALE
PROJECT NO. 21019 RECORD DRAWING R-4 19304
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
DESIGN SURVEYING
12700 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
CITY OF TEMPORARY EROSION &
RENTON SEDIMENT CONTROL DETAILS & NOTES
Planning/Building/Public Works Dept.
NOV 2021
PAGE:
C2.31
T: 3 OF: 15
L0
Ful
I 30'
/ EX SIDEWALK & CURB AT
/ CONNECTION POINT TO BE
REPLACED TO NEAREST JOINT
I I
PER COR STD PLAN 110.1
CURB TRANSITION, SEE DETAIL
/ I SHEET C3.31
/ PUGET POWER ESM'T REC.
/ NO. 8404060488 COMMUNICATION o
PUGET POWER ESM'T REC. NO. ESM'T REC. NO. 8405040925 21*33.67, 18.45' L
/ 8404060488 DRAINAGE & UTILITY d� END REMOVAL OF EX
ESM'T REC. NO. 8411060415 I \ CURB &GUTTER &
INS TALLA TION OF NEW
d CURB & GUTTER
--�- - ----- ---- ---- — — — — — — — ---- -- — / — — — — — /
\ ag' a�'\ 2' I I
_ _ _ _
BM A'
\------- ---� r-------- ,---------� I I I
5 DRAINAGE & UTILITY PLANTS
ESM'T REC. N0. 8411 I �� I / I / — _ r- / / 5' SIDEWALK
I , I, I I
2' ROW EX/STING 30 ROW I
I I I I I( DED/CAT/ON
II
SAWCUT I I
5 2sSF � 1 1 1
- / 1 SECTION B_ B ,n
PAD / 1 I THIS SHEET
469.7 <"' I o \
��.
CALL: 1" = 10'
0 5 10 20
CB
RIM=471.88
INV. 12"(N)=470.42
INV. 12"(S)-470.36
o
o I I I I I 7,561 SF I I 20' BSBL I I J \ I 20 BSBL- \ /
5 BSBL
I I PAD I / o oo I I I CEMENT CONCRETE TRAFFIC CURB
I I 467.0 (� ���� — & GUTTER PER COR STD PLAN
I p�6� I I \ I \ =101, SEE DETAIL SHEET C3.31
I I I PRIVATE STORM
I I I EASEMENT I I 10' PR/VA RO w\ o
= I I I I 1 I I I l UTILITY EASEMEN \ 170E SF \ I =
—�— — — W
I I / I \ I I A I\ V I
/ I I I al \ I — — — — — I I Pj
F.
\ / I
� J
12 08 2f0 I I i r----------------------------------�� i 11f00 RELOCATE EXELEPHONE d 10 0 9 5 \
I I I I \ I s TRACTA PEDESTAL COORD ATE WITH
i
i
I —
I ,' I
\ \`� ;
�`'
2,132E SF
UTILITY OMPANY
I
`
\
z�
I
..
d
•.I
----1-------------------------------------
I �
\
I
I
I
II
I \
Q
I
I
I
----------
\
ag
\
all
I
I
I
CL
- N89 51 '03"W 178.00 A -
------———
—— ----
— — — — ——PUGET POWER ESM'T REC. NO.
SET LEAD &
I
\
8404060488 DRAINAGE & UTILITY
SECTION A -A
TACK I
I I I
ESM'T REC. N0. 8411060415
THIS SHEET
I
I
I
i
LOT 3 CEMENT CONCRETE TRAFFIC CURB
& GUTTER PER COR STD PLAN
SOUTH E' ( E
MOW CURB 0.1' (S)
d I
I
I
PA
NW
24.5' ACCESS AND UT/L/TY EASEMENT
v 16'
0
8' 8' 8'
I
2X- 0. 5,
CEMENT CONCRETE TRAFFIC CURB
& GUTTER PER COR STD PLAN
101, SEE DETAIL SHEET C3.31
2" HMA CLASS 112" PG 64-22
- 4" HMA CLASS 112" OR 1 " PG 64-22
4"1 114" MINUS CRUSHED ROCK BASE COURSE
PER WSDOT STD SPEC. 9-039(3)
SECTIONA A
TRACTA
NO SCALE
101, SEE DETAIL SHEET C3.31 I � d . I
EX SIDEWALK &CURB A T I
CONNECTION POINT TO BE
REPLACED TO NEAREST JOINT
PER COR STD PLAN 110.1 o
I
I I I
I I
I I I
PUGET POWER ESM'T REC. NO.
8404060488 COMMUNICATION ESM'T
REC. NO. 8405040925 STUB
2' ROW RIW EX. 30' ROW EX. 30' ROW R/W I I
�D/CAT/ON 3' f 18.5' EX PA VfMEN T I I I
5' 8' SSMH ,
S/W LAN 2' 16' CB RIM472.11
11 RIM471.60 INV.8"(N)=463.01 ss
20f 65.17, 18.45' L
DRI VEWA Y CL
22' CEMENT CONCRETE DRIVE -HAY
ENTRANCE TYPE RIB PER COR
STD PLAN 104.3, SEE DETAIL
SHEET C3.,31
20f 48. 67, 18. 45' L
BEGIN REMOVAL OF EX
CURB & GUTTER &
INSTALLATION OF NEW
CURB & GUTTER
3' CURB TRANSITION, SEE DETAIL
SHEET C3.31
CONTRACTOR TO GRIND &
0VERLAY EX ROAD PER COR
TRENCH RESTORATION & STREET
0VERLAY REQUIREMENTS
2-1MAXSLOPE' 29 6) INV.12 (N)=468.97 (CTR. OF CHANNEL o0
__---
SLOPE VAR/ES
- RECORD DRAWING R-4 7 9305
SIDEWALK PER COR STD PLAN 102 !/��\��%�/��\��\�� �===T�T�TT�T---------=======-=� —
CEMENT CONCRETE TRAFFIC CURB & GUTTER PER
COR STD PLAN 101, SEE DETAIL SHEET C3 31
CURB & GUTTER REPLACEMENT PER COR STD
PLAN 103, SEE DETAIL SHEET C3.31
PROJECT NO. 21019
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
�,ZDEKp
M
�����F•wq�yjtic�P-110000
� CIVIL ENGINEERING
'y LANDSCAPE ARCHITECTURE
SECTION B-B o 41 41846 PLANNING
• SURVEYING
FIELD A VE NE �0��`��I�NAL EN*� �� DESIGN
1210O NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
4-26-2023
SURVEYED: XXX SCALE. HORIZONTAL: NAD 1983/1991 __ ' CITY 0 F
DESIGNED: SHY r ,-.�
DRAWN: SES R E N T O N ONE INCH DATUM ROAD & GRADING PLAN
CHECKED: SHY AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
NO. REVISION BY DATE AP P R APPROVED: SHY SCALE ACCORDINGLY
NO SCALE
NOV 2021
FIELDBOOK:
PAGE:
DRAWING NO:
C3. 01
SHEET: 5 OF: 15
�
O'D\
CI
7
En'
FACE OF CURB
- 6 1 n"=
-
5 1/2" 1'
1/2" R. - _ 1" R 1:24
1 1 TOP OF
in 1/2" R. ROADWAY
1
1 to
T
- 1 - 6"
CEMENT CONCRETE
TRAFFIC CURB AND GUTTER
FACE OF ADJACENT CURB
- 6 1n"^_ FLUSH WITH GUTTER
PAN AT SIDEWALK
RAMP ENTRANCE
1:12 1:24
TOP OF
1n"R. ROADWAY
1
io
1
1 - 6" `
DEPRESSED CURB SECTION
AT SIDEWALK RAMPS
I3/8
• N.
PREMOLDED
JOINT FILLER
E FULL -DEPTH
EXPANSION JOINT
6" _ CEMENT CONCRETE
112" R. - 1" R SIDEWALK RAMP
VARIES OR LANDING
FROM 1
6"TOO
1
318" PREMOLDED
JOINT FILLER
CEMENT CONCRETE
PEDESTRIAN CURB
AT SIDEWALK RAMPS AND LANDINGS
FACE OF ADJACENT CURB
- 6 1 n"_
SEE DEPRESSED CURB DETAIL THIS SHEET
1:24
TOP OF
1 T 1" 1/2"R. ROADWAY
2"
1
— 1
1D
I
1' 6"
DEPRESSED CURB SECTION
AT RESIDENTIAL DRIVEWAYS ONLY.
FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2
FACE OF ADJACENT CURB
GUTTER SURFACE
FACE OF CURB
- 6 1 n•_
112" R. - 1" R.
1 1
TOP OF
ROADWAY
`v T
I
8 1/4"
CEMENT CONCRETE
TRAFFIC CURB
DEPRESSED CURB DETAIL
AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS
GENERAL NOTES:
1. See standard plans 102 and 101.1 for curb expansion and contraction joint spacing.
2. Expansion joint shall be full depth, 3/8' (in.) premolded joint filler.
3. For Depressed Monolithic Driveway Curb & Gutter Section, see Standard Plan 104.2
PUBLIC WORKS
STD. PLAN — 101
DEPARTMENT
• CEMENT CONCRETE CURBS it
r
SEE NOTES. --/
NOTES:
1. 18 INCH
CURB TRANSITION
NTS
"EE NOTES.
E RAISED EDGE DETAIL 1 -0 5
LEVEL �J 1/2• E7tTENo SIDEWALK TRANSVERSE 1'-D' 1'-0'
12• (IN) R I JOINTS TO INCLUDE RAISED EDGE
ROU DING 2.0%
I
to •� ••• � P 4 r
1'QNJ R. i• .•.•. a• 5��., �
SEE RAISED EDGE
1'-D" SIDEWALK DETAIL-THISSHE
ALL CUT MIN.
ES `LOP`
12' (IN) R. (TYP.)
i' % 1 1.5% FOR CURB DETAILS
SEE STD PLAN 101
aN��cE� rf
318• (IN) PREMOLDED JOINT FILLER
TYPICAL WHERE APPLICABLE
I 12• (IN) R. (TYP.)
FOR CURB DETAILS
SEE STO PLAN 1111
i"'--' •.�?--^-:.•r— STING ROADWAY
�-J1--------�T CRUSHED ROCK BAS
TYPICAL
UNDER •CRUSHED SURFACING TOP COURSE (CSTC)
SIDEWALK OMPACT TO 95% MODIFIED PROCTOR
WITH RAISED EDGE (UNLESS REQUIREMENT WAIVED BY
ENGINEER) TYPICAL UNDER ALL CURB,
GUTTER & SIDEWALK CSTC UNDER
CURB & GUTTER TO BE 6 THICKNESS OR
MATCH EXISTING ROADWAY CRUSHED ROCK
BASE, WHICHEVER IS GREATER (TYP. FOR
ALL CURB & GUTTER).
1 FINISHED GRADE 1-(IN) BELOW
TOP OF CONCRFTF SLIRFACF
2'-0"
SIDEWALK
ADJACENT TO CURB 1 c 1 o
MIN
ROU
DING
12• (IN) R. (TYP.)
FOR CURB DETALS
_2.0%
159�Gt�,
�j
SEE STD PLAN 101
••'��(.. y. f
sY�}t5'
,
• lv •�
BRIDGE OR PEDESTRUW
RAILING�ylP.
>t�
TO CURB
BARRIER -SEE
FOR cuRe DETAILS
SIDEWALK SEE STD PLAN 101.
(STEEP
(STEEP FILL SLOPES)
CONTRACT PLANS
ALL OR BARRIER
mr (IN) R. UYP.)
SIDEWALK
FLUA318-
1.5%
VERTICAL WALLSEE
DETAIL
(IN) PREMOLDED
JOINT FILLER
ADJACENT TO CURB AND RAILING OR WALL
8 (IN)
PREMOLDED
JOINT FILLER
FOR SIDE
TREATMENT
slSIDEWALKBUFFER
STRIP SIDEWALK ADJACENT TO WALL DETAIL
bhh
(SEE NOTE 10)
SIDEWALK
SECTIONS
12• (IN) R
1
1.5% _
(TYP.)
1.5% MIN.
FOR CURB DETAILS
SEE STD PLAN 101
BROOMED FINISH
OR MATCH EXISTING
Or
S
4• WIDE. SMOOTH
TROWELED PERIMETER
FINISHED GRADE 1' (IN) BELOW TOP OF CONCRETE
SURFACE FOR PLANTING - FLUSH IF PAVED
_
0' Q/
to,,O /~\
CEMENT CONCRETE CURB
ADJACENT TO BUFFER STRIP
\
FOR cuRB DErats
FORCU CURB DETAILS
Or ��
SEE STD PLAN 101
5,.0"
\\
D\�
NOTES
/
\\-�
1/8• TO 1/4'
1. Four feel of the sidewalk width shall
©
%
I,
be the minimum pedestrian
accessible route (Ptru frees.
rating
and horizontal obstructions. Gratings,
Access Covers, Junction Boxes,
Cable Vaults, Pull Boxes and other
`r�o
appurtenances Within the sidewalk
F
must be flush with surface, and match
grade of the sidewalk.
2. Monolithic Cement Concrete Curb and
Sidewalk Is not permitted in new
For other referenced NOTES see
construction. When replacement work
STD PLAN 104.2.
necessitates a Monolithic Cement
Concrete Curb build per WSDOT
Standard Plan F-30.10-03.
Paved surfaces must comply With
3. Concrete to be 4,000 PSI.
STD PLAN 102.1 as applicable.
PUBLIC WORKS
DEPARTMENT
CONTRACTION JOINT
IN SIDEWALK ONLY • •' •!. � TO 'r
FULL -DEPTH
CURB AND SIDEWALK
EXPANSION JOINT IN BOTH
(SEE STU PUN 101.1)
•--- -
3(8•
C_ CONTRACTION JOINT
JOINT AND FINISH
DETAIL
PREMOLDE
JOINT FILLER
• t.Ir�.•
I.P
E_ FULL -DEPTH
EXPANSION JOINT
STD
PLAN — 102
CEMENT CONCRETE ,1kPPIO)"• 1.-:1)
SIDEWALK
r
7 n' LAIAI _--__
,EXISTING ASPHF
PAVEMENT
SAWCUT
(SEE NOTE 2)
RTERIAL STREET MINIM
7" HMA (or ACP Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
RESIDENTIAL STREET MINIMUM I
4" HMA (or ACP Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
NOTES:
1. MUST MATCH EXISTING THICKNESS IF GREATER.
2. SAWCUT SHALL BE POSITIONED 1' — 0" BEYOND EDGE OF
DAMAGED PAVEMENT,
3. THE INTENT OF THIS DESIGN IS TO DESCRIBE PAVEMENT
PLACEMENT AT 'THE GUTTER FACE. SEE STANDARD PLAN
FOR CEMENT CONCRETE CURBS.
I S. PLAN — 103
+ :� + PUBLIC WORKS CURB AND GUTTER PPRO D:
DEPARTMENT REPLACEMENT DETAIL Z
�Z•^O ATE
8ID:1E4 NRUDt5S0EWALKRAMPS
I (SEE NOTES',
I
(SEE NOTE c
191F Of PAVED
DRNEWAY REOWRED
It FxPANgxR1 ANT RYP-1
CE
(SEE ETD PLAN 19]1
CC
ISic
E
I
=
BEE NOTE A
i
lEE NOTEt cEIAENT coNcRETE J
RN.W Mr. 1T1.1V B CURS AGUTTER
!LOPE ITYP.) !SEE NOTE 11
Sa-CONTRACTION JONT (1YP 1 7
(SEE STU, PLAN I'M PLAN VIEW
VARIES
A 3% UO SEE NOTE S ITYP)
L ICE.
IN CAEIE aSUN 09PRESMD CW A GUTTER 7a•EAPM910N JOWrfM.! 13�NDrE I7
SECTION A (SEE ETD. PLAN 1074
� - trtRPY►.I �MawrorN .\
00%DIFFERENCE N SLOPE MAX
-aRNEWAY w!i�G`lITNE !LOPE ISLOIE lNOMN E%AG7ERATE01 }_ ,.. tE%
tat
txEvawAr-•T^'rawa• .,.,
DAIMMYORELATIVIE
N O
SHOWN . ME"TWBLCM>M
1
CEMENT
C ONCRE-E
SIDEWALK
TYPE R1 B — ISOMETRIC VIEW
(RESIDENTIAL WITH BUFFER)
CEMENT CONCRETE
cum a GUTTER
(Sea ROTE 3)
For NOTES STD. PLAN 104.2
o STD. PLAN — 104.3
+ + PUBLIC WORKS CEMENT CONCRETE DRIVEWAY PPIR Vi'D
DEPARTMENT ENTRANCE - TYPE RIB M
OT
PROJECT NO. 21019
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
DESIGN SURVEYING
12100 NE 195th St, Suite 300 Bothell, Washington 98017 425.885.7877
4-26-2023
SURVEYED: XXX SCALE: VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DESIGNED; SHM
DRAWN: SES
ONE IN DATU M
CHECKED: SHM AT FULL SCALE
IF NOT ONE INCH
NO. REVISION BY DATE APPR APPROVED; SHM SCALE ACCORDINGLY
CITY OF
RENTON
Planning/Building/Public Works Dept.
Gregg Zimmerman, Public Works Administrator
RECORD DRAWING R-419306
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
NOV 2021
ROAD DETAILS PAGE:
C3.31
T: 6
OF: 15
S
LN",
O
i
Q
M
N
CL
Ful
SEE SHEET C4.21
I /
I I /
I I
I /
I I
I I /
I
9303
z -93�F 12" PVC
CB ✓ 0 4-9B 0.0082 APPLICANTS ARBORIST
N.• 19879.15
E.• 19794.18
TYPE 2-48" \
SOLID LOCKING LID `
R/M-*2-06-462.15 - -
12" lE /N 4_459B-(SX6.05 -
12" If OUT 455 9&-(N)455.95
I � r-
I
I
I �
I�
a
---� ---- --�- -- -----J a
---- �----- N89°51'03"W 178.00
7 --- - - - - - - - - - - el
1
� I
2 1 I�1 � ,• I
11 CD
51264f SF 11 \ Lc)
00
66.43
F ®-e-eeVc� I I I / I I I \ \ i ROW
co
0.0065 i I I I I / I � I \ \ PROPOSED 1 " WA TER METERS TO BE o
co
INSTALLED BY D/STR/CT FORCES, A CD
CD I CD
I I I I 7,, $65f SF RN/SHM ADE 46Y 62 � I 6" IE 465. 00 � � WA TER METER PERMIT /5 REQUIRED
6.9 `�1466.12(AB) L- �- ----� \ 1
UTILITY CROSSI to P!7/I/d �
I I I CO I EX STORM P/PE
i I I I II 6" lE 464.44 I - - - - UTILITY EASEMENT - a
- - �11 RF RFMU1/£D
o I I �� / 1 I I SSCO 3 SSCO PER CO2R STD \
R/M 468 4-F 469.02 \ \ PLAN 403.1 & 406.1 1
6 /E 466�8- 465.90 SSCO 1
6" lE 462.54 I 6 /E 466-28-465.90 8� 472.17RIM V �
PRIVATE STORM I \ �I ® I F 1
/ 0------------------------------------- -- o--------p
/ EASEMENT "
------------------------------------ ------ 73LF 6 PVC 6r l 464.75
66 12" PVC
( ®-9-3'r'r i \
n_;263
12 08 I2f0 I \\ r-----------+-�--------�
1 I l 12" If 456.70 \ 12" IE 60
37.81 I I I
3t9tF12 PVC I ---------------------------------- ------- I
E.• 19794.00
TYPE 2-48' SOLID LOCKING LID
RIM-,* 460.53
12" /F /N 466-34- (E)456°53
6" If IN -45E64 (5E)456.53
12" 1E OUT #646 ::3O (N)456 48
SHALL BE PRESENT
DURING EXCA VAT/ON FOR
STORM LINE
-- --------�--
00
-20LF 6" PVC
00.075
y ----- ` z----�-70.0044-------- i
40LF 6" PVCI � 0060 -0-------- \---------- ----------04 - ---------
\
----
N89°51'03"W 178.00
TYPE 2 CATCH BASIN PER 6" VAULT FOOTING DRAIN
COR STD PLAN 201.00 LOT 3
(TYP)
UTILITY CROSSING TABLE
CROSSING #
UPPER NETWORK
UPPER P/PE /E
LOWER PIPE CROWN
LOWER NETWORK
CLEARANCE
1
466.14
465.05
1.10
DETENTION VAULT, SEE
DETAIL ON SHEET C4.31
_.I
RIM 19.-69 472.177
TRACnA 99.65 6 /E-4E�P464.4�1
2,132f s M8LF 12" PVC 6" IF 464.441
® ig.-9_590.0467
T�
- - - --
STA. 11 f 17.42, 7.25' L T
TYPE 1,
RIM-46;�.:99- 468.06
12" IF IN 46-968- (E) 463.06
12" If IN -463- 60 (W) 462. 94
6" If /N 469 59 (N) 463.36
SCALE: 1" = 10'
0 5 10 20
SURVEYED: XXX
DESIGNED: SHY
DRAWN: SES
CHECKED: SHY
NO. REVISION BY DATE APPR APPROVED. SHY
4-26-2023
SCALE:
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
SET LEAD & --- I
TACK
I
SOUTH EDGE
MOW CURB 0.1' (S)
STA. 20f 18.04, 18.14' L T
R/M 471.60
12" IE OUT 468.97 (N)
0
JV 1
N
I
DIM „A„ /
TRENCH & BACKFILL PER
COR STD PLAN 220.20
I TA.20*9866, 17.70' L T
TYPE 1, /
RIM 4;7-2 09 471.95
EX 12" IE OUT 466 i8 N)
467.63
\ o
FIRE HYDRANT /
FLANGE EL 472.46 84
o �
-47 6" VC
0.0
I I r -
d PVC 10 00
: I 00.020
-- f BM „B„
� I
-----
PROJECT NO. 21019
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
DESIGN SURVEYING
12700 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
com
HORIZV ONTAL: NAD 1983/1991 CITY OF
RENTON
DATUM
Planning/Building/Public Works Dept.
STA. 21f33.67, 7.17' RT
48" SSMH PER COR
STD PLAN 400.1
RIU0;7z" 0 0 472.47
8" 1E OUT 46432 (S)
46387
TYPE 1 CATCH BAS/N
PER COR STD PLAN
= 200.00 (TYP)
/ CB
RIM=471.88
/NV.12"(N)=470.42
1NV.12"(S)=470.36
/ o
0
TOP 6F NUT
EL 470.20 (AB)
STA. 10* 17. 69, 7.25' L T
TYPE 1,
RIM �? BB- 471.71
12 IE IN 466 &&- (S) 468.26
12" IE OUT 466 L9& (W)467.91
0
STA. 20f04.04, 7.51' RT
TYPE 1-48"
RlM-4;7z" N 472.13
8" /E IN 463. r� (N) 462.89
i I S-419302
RECORD DRAWING R-419307
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
UTILITY PLAN
NOV 2021
FIELDBOOK:
PAGE:
DRAWING NO:
C4. Ol
SHEET: 7 OF: 15
S
i
i
0
Ful
470
m
450
m
i
i
i
i
L-----------------------------------------------------
0+00 0+50 1+00
FIND 4"X4" CONC. MON
_ WITH 2" BRASS DISC
6�, O LOCATED 7-21 -20
36 6� _
L= 3g. n�
RIM=442.75
INV.8"(N)=437.85
INV. 1 2"(E)-437.45
INV. 12"(W)=437.23
SCALE:
0 5
EX SIDEWALK & CURB
AT CONNECTION POINT
TO BE REPLACED TO
NEAREST ✓OINT PER
COR STD PLAN 110.1
17.64
-ff- 12" DI-
O-R 996
0.0476
DRY UTILITY ONDUIT
TOP OF PHON 455.94
BOTTOM OF CONDUI 454.79
TOP OF GAS 455.33
13.80
1-5EF 18" PVC
---�� 99,9;1
E.• 19794.43
TYPE 2-48' SOLID LOCKING LID
RIM 459.42 �
12" If IN�(5)455J7 �
12" IE OUT 9-(N)453.37
I
I
4-26-2023 I NO. I REVISION
o
VV
k
o�
V
o�
Q�
L �-
���
CONFIRM AND Vf-RIFY THE EXISTING
STORMWATER PIPE ELEVATION, IF THE
ELEVATIONS DO NOT MATCH THE PLAN,
CONTACT ENGINEER TO Vf-RIFY THE DESIGN
BEFORE CONSTRUCTION.
EXISTING GRADE
476
EXISTING GRADE 00
0 CIL OF PIPE
466
04
CL
93.03 0 OX2
Q-3LF 12 PVC 0 -& 9962
JV
0 o a
456
o
W
C ^
V
.
�
446
STORM
HORIZ. SCALE- 1 "=10'
VERT. SCALE- 1 "5'
\i i i
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 - - - - - - - - - - - - - - - - - - - - - - - - - -
1f50 2+00 2+50
SDVH
RIM-459.40
INV.6"(N)=456.85
INV.8"(S)=456.68
a.. j
1 d 1 t
e Q �dA.
1 a
C1A
ND 4"X4" C%ONC. 00�
N.•19990.25 WITH 2" RASS DIS(
E.r19794.50 / LOCATE 7-21 -j2(
HYPE 1, SOLID LOCKING LID
2/M /E-45-9 9-(S)452.53 / I
-� X.12" If IN 89-(E)453.90 / I
1BOUT 4,42 9-(W)452.33 I
ILA{— 3 9 ' 0 2 — —
1 \ /
I LOCATE EXISTING STORM
TO CONNECT C91A
- TOP OF GAS 455.33 \ I
\ I
_= SD SD
:4a�. a I a
v
/ RIM=459,?6
i � �93.03 INV.8"('IV)-456.71 �
F 12 " PVC IN,�.12"(E)-456.51 /
0 $.••BBB
0.0062 �fNV.6"(S)=456.44 /
/ INV.12"(W)=456.31 /
SEE SHEET C4.01
SURVEYED: XXX
SCALE
DESIGNED: SHY
DRAWN: SES
ONE INCH
CHECKED: SHY
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
BY
DATE
APPR
APPROVED: SHY
ROJECT NO. 29099
W
m
Q
CIVIL ENGINEERING
ZE LANDSCAPE ARCHITECTURE
PLANNING
DESIGN SURVEYING
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
HORIZONTAL: NAD 1983/1991 CITY OF
RENTON
DATUM
Planning/Building/Public Works Dept.
470
m
m
3+00 +50
S-4 7 9303
RECORD DRAWING R-4 7 9308
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
NOV 2021
UTILITY PLAN & PROFILE o IM
C4.21
T: 8 OF: 15
O
O
O
1
N
Cx
CL
I
N
V
V0
ON"
CI
Em,
I / �
/�6 I
I I
I I '
I I 7, 65f SF
I I
I I I
I � �
/ 7'APP/E
12 VENT PIPE (TYP) - � - -
/ I \456.24
I
I IA
L
1 B"APP� i
CONTROL STRUCTURE
I' I
B I 1456,241 \ `-
---o ------------------
o
' 455.94
\ 455.94 d
----------------------
-------------------
SEE DETAIL THIS SHEET
452.5-6\
REMOVABLE WATERTIGHT
COUPLING OR FLANGE -
BJ
u
LEI1� o0
456.24
N89°51'03"W 178.00
VA UL T - INTERIOR DETAIL
2' MIN. CLEARANCE TO
ANY PORTION OF FLOW RESTRICTOR
TEE INCLUDING ELBOWS
2" MIN.
ELBOW RESTRICTOR,
SEE DETAIL AND NOTE 10
6" MIN.
6" MAX.
PLATE WELDED TO ELBOW WITH
ORIFICE AS SPECIFIED, SEE NOTE 3
ELBOW RESTRICTOR DETAIL
��� fir\
I/�_ _ II I
III 1 / I) �
� / / ANGLE AS /
�'�/ NECESSARY, /
SEE NOTE,7
2' MIN, `�---��/
ELEVATION PER PLANS
12" MIN. UNDER
PAVEMENT
16" MAX.
6" MIN.
ELBOW RESTRICTOR,
SEE DETAIL AND NOTE 10
PIPE SUPPORTS, SEE NOTE 6 -
1.5 x D
MIN.
T
456.73 D
�° /E�i5E53 I
OUTLET PIPE, SEE
NOTES 1 & 5
INVERT AND
ELEVATION PER PLANS
12" SECTION OF PIPE ATTACHED BY
GASKETED BAND TO ALLOW REMOVAL
DRILL OR MACHINE CUT 7/16' O
454.73 ORIFICEdIN WELDED
RESTRICTOR END PLATE
PLAN VIEW
ADDITIONAL LADDER RUNGS (IN SETS) TO
ALLOW ACCESS TO TANKS OR VAULTS
WHEN CATCH IS FILLED WITH WATER
FRAME & SOLID COVER MARKED "DRAIN" WITH
LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50
DESIGN WATERQ
SURFACE
12" (TYP.)
- 2' MIN.
2'
o MIN.
2'
MIN.
12" j
FEL
RISER ELEV 463.22- 3.38
MAX. W.S ELEV .3,8
HANDHOLDS, STEPS, OR LADDER
SEE NOTE 9 (TYP.)
INLET PIPE
- SHEAR GATE WITH CONTROL ROD FOR
CLEANOUT/DRAIN (ROD BENT AS REQUIRED
FOR VERTICAL ALIGNMENT WITH COVER)
PER STD. PLAN 237.30
NOTES: SECTION A
1. USE A MIMIMUM OF A 54" DIAMETER TYPE 2 CATCH BASIN.
2. OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW.
3. METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5.
4. FRAME AND LADDER OR STEPS OFFSET SO:
A. CLEANOUT GATE IS VISIBLE FROM TOP.
B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE.
C. FRAME IS CLEAR OF CURB.
5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4".
6. PROVIDE AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM T-0" VERTICAL SPACING).
7. LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN.
8. LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER.
9. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING
TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE.
10. IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 237.00
o PUBLIC WORKS FLOW CONTROL STRUCTURE - DMSW.edby: `�I� DEPARTMENT RESTRICTOR TEE artin Pastucha 8/13/20
... DATE
CONTROL STRUCTURE
NTS
NO.
470
mm
450
I I 7," SF 1 i ❑
- - - -
to
/ 7'APP/ E \ I I I
/ 46'
12" WNn�,4770V
PRE------------------------------------- ------
\` \ 6" If-462.54
>--------------------------------
12" IkENRA nON
456. 0
1 B" APPLE 1�� P/PE
12„ lE 460.
24" MANHOLE ACCESS 24" MANHOLE ACCESS
R/M-4ff-89-465.46 RIM 46F-E,-467.67
7777
-- --- 466 ----�
N89°51'03"W 178.00
VAUL T - EXTERIOR DETAIL
PROPOSED GRADE (TYR)
ACCESS
ACCESS
EX/STING GRADE (TYP.)
RISER
RISER
- -
_1
TOP OF LID 464.72
22t!r-
- _
J�i
BOTTOM OF L/D 463.72
MAX WA TER SURFACE 463.22
-
-
J i
6» 1E 462.54143
12" lE
456.70
44'
12 /E -
.
BOTTOM OF LIVE
.STORAGE 456.59
456.24
455.94
455.94
5" THICK
SLAB
VAUL
TA A
HORIZ. SCALE-
1" =10'
VERT. SCA
E.- 1 "-5'
REVISION
0+50
SURVEYED: XXX
DESIGNED; SHM
DRAWN: SES
CHECKED: SHM
BY DATE APPR APPROVED; SHM
4-26-2023
SCALE:
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
SCALE: 1" = 10'
0 5 10 20
470 470 PROPOSED GRADE (TYR) 470
EXISTING GRADE (TYR) . .
. 228'.
2.28, TOP OF LID 464.72
BOTTOM OF LID 463.7
MAX WATER SURFACE 46J22
460 460 "' 460
o .
14'11 BOTTOM OF LIVE
5" THICK �94
TORAGE 456.59
SLAB 455 456.24
450 450
1+00
452.
PROJECT NO. 21019
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
DESIGN SURVEYING
c 0 a
�zm�
12100 NE 195th St, Suite 300 Bothell, Washington 98017 425.885.7877
HORIZONTAL NAD 1983/1991 Ad=t16CITY OF
' RENTON
DATU M
Planning/Building/Public Works Dept.
VAUL T B--B
1 HORIZ. SCALE.• "-10'
INERT. SCALE- 1 '=5'
0+50
RECORD DRAWING R-419310
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DETENTION VAULT DETAILS
NOV 2021
FIELDBOOK:
PAGE:
DRAWING NO:
C4.31
SHEET: OF:
10
15
�0
N
SURFACE WATER STANDARD PLAN NOTES:
THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY
PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE
APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE
SURFACE WATER STANDARD PLAN NOTES.
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY
REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR.
2. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION.
3. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE
WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL
CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO
CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO
THE CITY.
4. APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER,
SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY
THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION
FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY.
5. A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
6. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL
THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANT'S
CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT
SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL
UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A
CONFLICT EXISTS.
7. VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY.
REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS.
8. ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95 % MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND
MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BACKFILL SHALL
BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92 % OF MAXIMUM DRY DENSITY.
9. OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE
APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS.
10. ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE
DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED.
11. ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE
APPROVED BY THE CITY.
12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD
SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION
MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE
SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10, AND
220.20.
13. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 5 INSIDE AND OUTSIDE.
14. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN
204.10, 204.20, 204.30, 204.40, AND 204.50. STRUCTURES SHALL HAVE:
• RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY.
• ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE.
• ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE
PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO.
15. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM.
16. LIDS OF MANHOLES/CATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/CATCH BASIN RIMS
SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN.
17. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE
DRIVEWAY TO THE BOTTOM OF THE DITCH.
UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS)
AdaSTD. PLAN - 267.00
V
�•i PUBLIC WORKS SURFACE WATER STANDARD PLAN �68�,dby�I DEPARTMENT NOTES (1 OF 2) artin Pastucha8/13/2020
Martin Pas ha
8&'hH�3faId886iA4®D... DATE
1
SEE STANDARD PLANS 110, 110.1, 110.2, AND 111 FOR PAVEMENT
RESTORATION REQUIREMENTS
SURFACE RESTORATION AS
SPECIFIED IN CONTRACT DOCUMENTS
12" MIN. EXISTING PAVEMENT SURFACE
II
----Z
----------
NEAT LINE TRENCH
i" MIN., SEE NOTE 4
� X \ I
"CRUSHED SURFACING TOP COURSE" PER
WSDOT STD. SPEC 9-03.9(3), COMPACTED
TO 95% OF MAXIMUM DENSITY
"CRUSHED SURFACING TOP COURSE" PER
WSDOT STD. SPEC 9-03.9(3), "BANK RUN
GRAVEL FOR TRENCH BACKFILL" PER
WSDOT STD. SPEC 9-03.19, OR "GRAVEL
BORROW" PER WSDOT STD. SPEC 9-03.14(1),
COMPACTED TO 95 % OF MAXIMUM DENSITY
BENCH NEEDED FOR
SHORING
SYSTEM WHEN t /
DEPTH IS 4' OR GREATER
PIPE \\�
PIPE ZONE BEDDING AND BACKFILL
PER STD. PLANS 220.00 AND 220.10 )/A
SEE NOTE 1
UNPAVED AREAS I PAVED AREAS
NOTES:
1. SEE WSDOT/APWA STANDARD SPECIFICATIONS SECTION 2-09.4 FOR
MEASUREMENT OF TRENCH WIDTH.
2. EXCAVATIONS OVER 4' DEEP SHALL COMPLY WITH THE SAFETY STANDARD
DESCRIBED IN CHAPTER 295-155 PART N OF THE WAC.
3. MAXIMUM BACKFILL DEPTH ABOVE PIPE SHALL NOT BE EXCEEDED, AS
DETERMINED BY PIPE MANUFACTURER.
4. IN PAVED AREAS, IF PIPE HAS LESS THAN 3' OF COVER, USE "CRUSHED
SURFACING TOP COURSE" FOR THE ENTIRE BACKFILL DEPTH ABOVE PIPE ZONE.
5. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 220.20
o PUBLIC WORKS TYPICAL TRENCH AND BACKFILL PR D. 9/28/2018 1
ter,` DEPARTMENT GAZ
Public Works Administrator DATE
SURFACE WATER STANDARD PLAN NOTES:
THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY
PROJECT. THE APPLICANT OR OWNER HEREBY REFERRED TO AS APPLICANT MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER THE
APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE
SURFACE WATER STANDARD PLAN NOTES.
18. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT
AND SHALL MEET THE FOLLOWING SPECIFICATIONS:
• 4 - 81NCH ROCK / 40 - 70% PASSING;
• 2-4INCH ROCK l30-40%PASSING; AND
• LESS THAN 2 INCH ROCK / 10 - 20% PASSING.
19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE
CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS.
20. THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED "STORM" OR "DRAIN" SHALL BE LOCATED AT THE
PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00.
21. ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED
TO THE CITY PRIOR TO CONSTRUCTION.
22. ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV
ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL
PROJECT CURBS, GUTTERS AND/OR PAVEMENT.
23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS
AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS
TESTED.
24. FOR ALL DISTURBED PERVIOUS AREAS COMPACTED GRADED LANDSCAPED ETC. OF THE DEVELOPMENT SITE TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL
EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN
264.00.
25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY
CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM
SYSTEM PROVIDED DURING CONSTRUCTION.
26, ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF
THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED
RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT
STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY.
27. PROJECTS LOCATED WITHIN THE CITY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE RENTON SWDM AND AQUIFER
PROTECTION REGULATIONS (RMC 4-3-050).
28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF
STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A
SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NONSKID LID PER ADA REQUIREMENTS.
29. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT.
30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM.
31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE
PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO
CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE
PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE
MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE,
THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE
WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING
ASTM C1781.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 267.10
,�. PUBLIC WORKS SURFACE WATER STANDARD PLAN EVbWUW§Redby:
DEPARTMENT NOTES (2 OF 2) artin Pastuch�13/zozo
mania Pa:tacha DATE
IB®SA(dhF.098D...
CENTERLINE OF DRAINAGE STRUCTURE
MAY DIFFER FROM THE CENTERLINE
OFTHE FRAME AND GRATE
TRANSITION
1'-8"MIN.
BACK EDGE OF FRAME EVEN
WITH BACK FACE OF CURB
20 318"
19"
PLAN
ROLLED INLET
1Ik .y+
S+
2", 4", 6", 12", OR 24"
ONE #3 BAR HOOP FOR 6" HEIGHT
INCREMENT (SPACED EQUALLY),
SEE NOTE 1
RECTANGULAR ADJUSTMENT SECTION
�.
Sao'
E
ti6 5
A
#3 BAR EACH CORNER
�OTR�
#3 BAR EACH SIDE
a
#3 BAR EACH WAY
PRECAST BASE SECTION
#3 BAR HOOP
#3 BAR EACH
CORNER 18" MIN.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
PUBLIC WORKS
DEPARTMENT
V I
NOTES
1. Bolt down capability is required on all frames, grates, and covers,
unless specified otherwise in the contract. Provide 2 holes in the
TRANSITION frame that are vertically aligned with the grate or cover slots.
1'- 6" MIN. The frame shall accept the 304 Stainless Steel (S.S.) 5/8" (in)
- 11 NC x 2" alien head cap screw by being tapped, or other
approved mechanism. Location of bolt -down holes varies
by manufacturer.
2. Refer to Standard Specification, Section 9-05.15 and
9-05.15(2) for additional requirements.
3. For Adjustment Section Details - See Standard Plan B-30.90.
4. Size and dimensions of drains vary by Manufacturer, but open
area shall be 1.5 square feet minimum.
TRANSITION
FRONT EDGE OF FRAME 4" R
FLUSH WITH STREET/
GUTTER SURFACE
I
MATCH ROADWAY SLOPE
I
r
17"
31"
SECTION O
I\►d
REVISION
27 3/16"
25 3/4"
SECTION gO
ISOMETRIC VIEW
��N OP NASx7 f
�oA f S TE4��
�SSIONAL
Julie Heilman
2020.09.01 07:51:27-07'00'
ROLLED CURB DRAIN
STANDARD PLAN B-30.05-00
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION
Dioally signed by Roark, Steve
Oar Steve D,to:2020.09.0909:49:t5-or00'
STALE DESIGN ENGINEER
washing- State Department of Tronap,nation
SURVEYED: XXX
DESIGNED: SHM
DRAWN: SES
CHECKED: ,SLH/V/
BY DATE APPR APPROVED: SHM
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR PLAIN
12"
CONCRETE
ALL METAL PIPE
15"
CPSSP',
STD. SPEC. 9-05.20
12"
SOLID WALL PVC,
STD. SPEC. 9-05.12(1)
15"
PROFILE WALL PVC,
STD. SPEC. 9-05.12(2)
15"
' CORRUGATED POLYETHYLENE STORM
SEWER PIPE
NOTES:
1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN
IN THE PRECAST BASE SECTION, FIBERS (PLACED IN
ACCORDANCE WITH STANDARD SPECIFICATION
9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF
0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH
THE MINIMUM REQUIRED REBAR SHOWN IN THE
ALTERNATIVE PRECAST BASE SECTION. WIRE MESH
SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN
ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN
THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH
HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER
FOOT MAY BE USED.
2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER
THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS
OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5"
MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE
OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED,
FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-04.3.
3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO
THE LOWEST PIPE INVERT SHALL BE 5 FEET.
4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE
FLANGE DOWN.
5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED
FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF
1 H:24V OR STEEPER.
6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE
PRECAST BASE SECTION.
7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE
INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR
NON -SHRINK APPLICATIONS IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-20.3(2).
8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN
MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE
AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND
FRAMES.
9. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 200.00
APPR ED:
CATCH BASIN TYPE 1 GqZ 9/28/2018 1
Public Works Administrator DATE
4-26-2023
SCALE:
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
4" MIN.
28" MAX. 16" MAX.
FF
48", 54", 60", 72", 84",
96", 120" OR 144"
15' M I . FOR
CATCH BASIN FRAME AND VANED
GRATE PER STD. PLAN 204.00
RECTANGULAR OR CIRCULAR ADJUSTMENT
SECTION (TWO SECTIONS MAX.)
- MORTAR, (TYP.), SEE NOTE 5
FLAT SLAB TOP
SEE NOTE 6, TYP.
MAINTENANCE
STEPS OR
LADDER
12" (TYP.)
YMAX',.
1"MIN"O"RING
24"
2.5" MAFORCING
STEEL, (TYP.)
MIN. 12"aGRAVEL
BACKFILL FOR PIPE ZONE
BEDDING PER WSDOT STD.
SPECIFICATION SECTION 9-03.12(3)
6"
6"
SEPARATE 1AS1E INTEGRAL BASE
PRECAST
PRECAST WITH RISER
NOTES:
1. NO STEPS ARE REQUIRED WHEN HEIGHT IS W OR LESS.
2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE
SLOPED TO FACILITATE CLEANING.
3. THE RECTANGULAR FRAME AND GRATE MUST BE
INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE
CAST INTO THE ADJUSTMENT SECTION.
4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2"
MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP
BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE
PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH
JOINT MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3.
5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET
IN MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3.
6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE
CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE
ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO
AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF
THE SAME MATERIAL AS THE CONNECTING PIPE.
7. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION.
CATCH BASIN DIMENSIONS
CATCH BASIN
DIAMETER
MIN. WALL
THICKNESS
MIN. BASE
THICKNESS
MAXIMUM
KNOCKOUT SIZE
MINIMUM
DISTANCE
BETWEEN
KNOCKOUTS
48"
4"
6"
36"
8"
54"
4.5"
8"
42"
8"
60"
5"
8"
48"
8"
72"
6"
8"
60"
12"
84"
8"
12"
72"
12"
96"
8"
12"
MI.
12"
120"
10"
12"
96"
12"
144"
1 12"
12"
108"
12"
PIPE ALLOWANCES
CATCH BASIN
PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER
DIAMETER
CONCRETE
ALL METAL
CPSSP t
SOLID WALL
PVC 2
PROFILE WALL
PVC 3
48"
24"
30"
24"
30"
30"
54"
30"
36"
30"
36"
36"
60"
36"
42"
36"
42"
42"
72"
42„
54"
42„
48"
48"
84"
54"
60"
54"
48"
48"
96"
60"
72"
60"
48"
48"
120"
66"
84"
60"
48"
48"
144"
78"
96"
60"
48"
48"
CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20)
2 STD. SPEC. 9-05.12(1)
s STD. SPEC. 9-05.12(2)
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 201.00
• PUBLIC WORKS CATCH BASIN TYPE 2 PR
'1` DEPARTMENT [62-
GAZ 9/28/2018 1
Public Works Administrator DATE
PROJECT NO. 21019
coffCIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
�ZDESIGN SURVEYING
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
HORIZONTAL: NAD 1983/1991 CITY OF
RENTON
DATU M
Planning/Building/Public Works Dept.
RECORD DRAWING R-41931 1
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
UTILITY DETAILS
Nov 2021
FIELDBOOK:
PAGE:
DRAWING NO:
C4.32
SHEEr: if
OF: 15
V0
ON"
CI
7
N
1
CL
Em,
5' 1
T
NOT TO SCALE
MANHOLE FRAME AND COVER
SEE STD PLAN 401
ADJUSTMENT RINGS AND MORTAR JOINTS
SEE NOTE 3
FIRST STEP SHALL BE A MAXIMUM OF 18"
BELOW THE COVER
CONE (ECCENTRIC)
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
RUBBER GASKETED JOINTS SEE NOTE 5
IF REQUIRED, LADDER -POLYPROPYLENE
SHALL BE ATTACHED TO MANHOLE
MAX PIPE SIZE - 'E'
SHELF AND CHANNEL SHALL BE
3000 PSI CONCRETE
PRECAST BASE SECTION
OR CAST IN SHELF
COMPACTED SUBGRADE WITH 6"
CRUSHED ROCK OR ADDITIONAL
MATERIAL SUITABLE TO
SUPPORT STRUCTURE
'A'
'B'
'C'
'D'
'E'
48" MH
48"
6" MIN.
5"MIN
24" MIN.
21" I D
54" MH
54"
8" MIN
5 5" MIN
24" MIN
24" I D
60" MH
60"
8" MIN
6" MIN
42" MIN
30" 1 D
NOTES.
1 STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED
2 MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE IN CONFORMANCE WITH ASTM C-478.
3 ADJUSTMENT OF THE CASTING TO GRADE SHALL BE PER STD PLAN 106 THE USE OF SHIMS IS PROHIBITED.
4 SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
FACTORY -COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING, WASSER MC-SHIELDCOAT 100 OR
APPROVED EQUAL, COLOR OF COATING SHALL BE WHITE
5 RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443
6 CHANNEL WIDTH AND HEIGHT SHALL EQUAL THE INSIDE DIAMETER OF THE LARGEST PIPE
7 CONNECTIONS TO MANHOLE SHALL BE MADE USING KOR-N-SEAL BOOTS OR APPROVED EQUAL
8 IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12"
ABOVE FINISHED GRADE OR MUST HAVE AN AT -GRADE, MINIMUM 2'-WIDE CONCRETE RING POURED AROUND
THE COVER IN PAVED AREAS, COVER MUST SLOPE TO MATCH PAVING.
9 MANHOLES OVER 20' DEEP SHALL BE A MINIMUM OF 60" IN DIAMETER
STD. PLAN - 400.2
gne y
• . PUBLIC WORKS STANDARD SANITARY MANHOLE 26/20z
DEPARTMENT Martin Pastucf��i
Martcygsy,Jff �dd9D
WdN,�AifhDATE
NO.
REVISION
o � o
USEWER'S
o�o�L
O � O
10-1/2"
_m�
tom--
2-1/4"
--�
1
CAST IRON RING AND
RECESSED Not to Scale
LIFT POCKET
FRAME
— I— .n__...__,. 1'—n„ fllA&drTCO 1'—r1'r
NOTES.
1 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC
No 3698 (PRODUCT NO 00369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY
2 IN UNIMPROVED AREAS, POUR A 8" THICK, 3'-0" SQUARE
CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER
3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106
DR
)ABLE
STD. PLAN - 403.1
• PUBLIC WORKS 8" OR 6" CLEANOUT °ne y
�I� DEPARTMENT FOR SANITARY SEWER MAIN Martin PastuCRa/26/2020
Q9
M' ,�Raw9D DATE
SURVEYED:
DESIGNED:
DRAWN:
CHECKED:
BY I DATE I APPR I APPROVED;
XXX
SHM
SES
SHM
SHM
4-26-2023
SCALE:
ONE INCH
AT FULL ---
IF NOT ONE INCH
SCALE ACCORDINGLY
��------------I
EX. SEWER MAIN
l PROPERTY LINE
—SPOOL
F�
+s
(LENGTH AS NEEDED) 3'-0" MIN
I I I O
6" SEWER STUB ! ! ! 4" FUTURE 4" SIDE SEWER
I I I
I •''
I I I
I I I rl
t I I I I
`SEWER MAIN TEE X 6" TEE
SIDEWALK
I I I I l i
COUPLING TYP I I I I >
tTJ 13
1
0
I'
x
I�
---------- T—J---------'1::6
L---�
BEND AS
REQUIRED
EXISTING SANITARY
SEWER MAIN nv uw SLOPE
`6" SEWER STUB
SEWER MAIN SIZE X 6" TEE
J2"x 4" STUD MARKING POST PAINTED
6" CAP J WHITE WITH THE WORD "SEWER" STENCILED
IN 3" HIGH BLACK LETTERS AND N6 WIRE
WRAPPED AROUND THE STUD AND
EXTENDED TO THE TOP OF THE STUD
6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER
(EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR
APPROVED EQUAL, SPECIFY "SEWER" ON LID),
CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD
CONCRETE PAD TO BE 8" IN DEPTH
1
T
FUTURE 4" SIDE SEWER
6"X6"X6" WYE FUTURE 6"x 4" REDUCER
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN
A VITRIFIED CLAY MAIN — CUT IN A NEW PVC "TEE" USING "STRONG —BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
B CONCRETE MAIN — CUT IN A NEW PVC "TEE" USING "STRONG —BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL)
C PVC & C900 PVC MAIN — CUT IN NEW TEE USING RIGID COUPLINGS OR CORE —DRILLED WITH A ROMAC SADDLE
(OR APPROVED EQUAL)
D. DUCTILE IRON MAIN — CORE —DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL)
E LINED MAIN — CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING
"STRONG —BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
F HDPE — CORE —DRILLED WITH A ROMAC SADDLE "INSERTA—TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER
G MANHOLE CONNECTION — ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK —OUTS OR THE STRUCTURE
SHALL BE CORE —DRILLED AND USE KOR—N—SEAL BOOTS OR APPROVED EQUAL
NOTES
1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT
2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER
3 SIDE SEWERS SHALL HAVE A MINIMUM 2 7 SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR
4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE
SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT
THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT —OF— WAY SHALL CONFORM TO STANDARD PLAN 110 OR 110 2
6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405
7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON
SIDE SEWER STUB STD. PLAN -406.1
• PUBLIC WORKS APP
DEPARTMENT INSTALLATION Martin PastuCh@V26/202,
(SEWER MAIN TO PROPERTY LINE) (..,&UFD98449DB
ftw,o W"d.m..Nrt ,p DATE
PROJECT NO. 21019
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
DESIGN SURVEYING
12100 NE 195th St, Suite 300 Bothell, Washington 98017 425.885.7877
HORIZONTAL NAD 1983/1991 CITY OF
OR
RENTON
DATU M
Planning/Building/Public Works Dept.
RECORD DRA WING
S-4 7 9304
R-4 7 93 7 2
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
NOV 2021
UTILITY DETAILS PAGE:
C4.33
T: f2 OF: 15
M
O�
O
Q
W
TREE REMOVAL TO BE
BY ARBORIS
PROTECTION (
DISTURBANCE F(
R
OFFSITE
SCALE: 1"
r�F���N
TREE RETENTION TABLE
Tree
No.
Regulated
Category
DBH
Species
DL (R')
LOD (R')
Health
Structutre
Comments on Condition
Viable
Tree?
Proposed
Action
1
Significant
10,12,12
Purpleleaf plum
17
10
2
2
Diseased, multiple stems
Yes
Retain
2
Significant
14
Western red -cedar
14
8
1
2
Asymmetric canopy
Yes
Retain
3
Significant
19
Deodar cedar
24
12
1
2
Asymmetric canopy
Yes
Remove
4
Significant
6
English laurel
16
6
1
2
Suppressed
Yes
Retain
5
Significant
6
English laurel
12
6
1
2
Suppressed
Yes
Remove
6
Significant
6
English laurel
12
6
1
2
Suppressed
Yes
Remove
7
Significant
6
Apple
10
6
2
2
Diseased, over -pruned
Yes
Remove
8
Significant
10
Apple
15
6
2
2
Diseased, over -pruned
Yes
Remove
9
Significant
3,4,4,E
Vine maple
8
1
2
Multiple leaders
Yes
Remove
10
Sig, offsite
25
Douglas-firL
�18�
15
Protect
Total
9
Significant
0
Dangerous
0
Landmark
9
Tota I Trees
NOTE
PER R.M.C. 04.04.130.H.9.B.
PROTECTION FENCING SHALL BE CHAIN LINK TEMPORARY CONSTRUCTION FENCING
AROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING
THE TREE EQUAL TO ONE AND ONE -QUARTER FEET (1-1/4') FOR EVERY ONE INCH (1") OF
TRUNK CALIPER, WHICHEVER IS GREATER. PLACARDS SHALL BE PLACED ON FENCING
EVERY FIFTY FEET (50') INDICATING THE WORDS, "NO TRESPASSING - PROTECTED
TREES," OR ON EACH SIDE OF THE FENCING. SITE ACCESS TO INDIVIDUALLY PROTECTED
TREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL
BE FENCED ON FOUR (4) SIDES. IN ADDITION, THE APPLICANT SHALL PROVIDE
SUPERVISION WHENEVER EQUIPMENT OR TRUCKS ARE MOVING NEAR TREES.
Total
Remove
6
Total
Retain
3
Total
Trees
9
TREE RETENTION CALCULATIONS
PER R.M.C. 04.04.130.H.1.A.1.
TOTAL ONSITE SIGNIFICANT TREES:
REQUIRED RETAINED SIGNIFICANT TREES:
PROVIDED RETAINED SIGNIFICANT TREES:
TOTAL REPLACEMENT TREES REQUIRED:
TREE DENSITY CALCULATIONS
PER R.M.C. 04.04.130.C.9.D
ADDITIONAL TREE PLANTING SCHEDULE
TREES QTY BOTANICAL NAME COMMON NAME SIZE SPACING
9 SIGNIFICANT TREES 2 ACER CIRCINATUM VINE MAPLE 2" CAL. MIN. AS SHOWN
3 (30 %) = 9 SIGNIFICANT TREES X .30
3 SIGNIFICANT TREES
0 TREES
LOT NUMBER
SQ. FT.
TREES
REQUIRED
TREES
REMAINING
TREES
PROVIDED
1
7,565
3
3
0
2
5,271
2
0
2
TOTAL
5
3
2
PROJECT NO. 21019
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
DESIGN SURVEYING
12700 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
LEGEND
TREE PROTECTION FENCING
SIGNIFICANT TREE TO BE RETAINED
SIGNIFICANT TREE TO BE REMOVED
R-4 7 93 7 3
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING
Ming 01/27/2022
CBS
CITY COMMENTS
SLB
I I//`0��
H
SURVEYED: XXX
SCALE: KMP
VERTICAL: NAVD 1988
HORIZONTAL: LAD 1983/1991
DATUM
T
•
I I
T 0 C
RENTON
tv
Planning/Building/Public Works Dept.
TWEE RETEYTIOY PLAY
TE
q
NOV
IVOV
DESIGNED JMP
OK,
FIELDBOOK:
PAGE:
DRAWN: /�✓'1n
`/
ONE INCH I
DRAWING N0:
a
ddL ll
CHECKED:-'i
y
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
N 0.
REVISION
Q T"
DATE
AP P R
APPROVED:
LAB
SHEET: 73 OF:
%4,6,
Ful
SIGNIFICANT TREES TO B
OFFSITE THE
PROPER
BUILDING SI
PLANT SCHEDULE
TREES QTY BOTANICAL NAME
fv 2 ACER CIRCINATUM
C9
+ 8 MAGNOLIA GRANDIFLORA 'LITTLE GEM'
STREET TREES QTY BOTANICAL NAME
L.
2
SHRUBS QTY
32
O 12
18
O 6
O 14
:. 15
GROUND COVERS QTY
COMMON NAME
VINE MAPLE
SIZE
2" CAL. M I N
DWARF SOUTHERN MAGNOLIA 1.5" CAL. MIN
COMMON NAME
SIZE
SPACING
AS SHOWN
AS SHOWN
SPACING
ACER TRUNCATUMX A. PLATINOIDES'KEITHSFORM' NORWEGIAN SUNSET MAPLE 2" CAL. MIN. 30' O.C.
BOTANICAL NAME
BERBERIS BUXIFOLIA'NANA'
CORNUS STOLONIFERA ' KELSEYI'
ERICA CARNEA 'VIVELLII'
POTENTILLA FRUTICOSA 'ABBOTSWOOD'
ROSMARINUS OFFICINALIS'ARP'
SPIRAEA DOUGLASII
BOTANICAL NAME
1,060 FESTUCA GLAUCA'ELIJAH BLUE'
COMMON NAME SIZE
DWARF BOXLEAF BARBERRY 2 GAL.
SPACING
AS SHOWN
KELSEY DOGWOOD 2 GAL/18" HT. MIN. AS SHOWN
NOTES:
PER R.M.C. 04.04.070.L.1.3.; L.1.4.C.; J.
1. ALL SHRUBS MUST BE OF SUFFICIENT SIZE AND NUMBER TO MEET THE REQUIRED
STANDARDS FOR NURSERY PLANT STOCK.
2. SHRUBS SHALL BE IN BEDS THAT INCLUDE A LAYER OF MULCH AT LEAST TWO INCHES
(2") IN DEPTH.
3. TREES SHALL INCLUDE A MULCH RING THAT HAS A DEPTH OF AT LEAST THREE INCHES
(3") AND IS AT LEAST THREE FEET (33) IN RADIUS AROUND THE TREE.
4. SOIL SHALL BE PREPARED FOR LANDSCAPE INSTALLATION ACCORDING TO INDUSTRY
STANDARDS TO BE CONDUCIVE TO THE HEALTHY GROWTH OF NEW PLANTS. TOPSOIL
SHALL BE RICH IN ORGANIC MATERIAL OR AMENDED TO BE SO. CLAY SOIL IS NOT
ACCEPTABLE AND MUST BE REMOVED FROM LANDSCAPE AREAS IF NATURALLY
PRESENT ON SITE.
5. ALL INSTALLED LANDSCAPING SHALL COMPLY WITH APPLICABLE CITY OF RENTON
REQUIREMENTS.
6. STREET TREE LOCATIONS ARE APPROXIMATE. ADJUST AS NEEDED DUE TO CONFLICTS
WITH UTILITIES AND/OR OTHER OBSTRUCTIONS ENCOUNTERED. ROOT BARRIER TO BE
USED WITHIN ALL PLANTER STRIPS CONTAINING STREET TREES.
7. STREET TREES AND PLANTER STRIPS TO BE MAINTAINED BY HOMEOWNERS.
8. COMPLIANCE WITH SOIL AMENDMENT BMP PER CITY OF RENTON 2017 SURFACE
WATER DESIGN MANUAL IS REQUIRED. SEE SHEET L2.31 FOR BMP DETAIL.
HEATH
1 GAL.
AS SHOWN
ABBOTSWOOD POTENTILLA
2 GAL.
AS SHOWN
ARP ROSEMARY
5 GAL./24" HT. MIN.
AS SHOWN
WESTERN SPIREA
COMMON NAME
5 GAL./24" HT. MIN.
SIZE
AS SHOWN
SPACING
of WAq
A`' tvxNNET"q®��'®
®� �Z0
aCORE
PROJECT NO. 21019
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
ELIJAH BLUE FESCUE
4" POT
12" O.C.
�����p.®�I��\�zm�
�gNDSC �
DESIGN SURVEYING
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
LBS
1
CITY COMMENTS
SLB
11/20/21
LBS
SURVEYED: XXX
SCALE: KMP
VERTICAL: NAVD 1988
HORIZONTAL: HAD 1983/1991
O T Y O C
DESIGNED: JMP
I I
.;" `, RENTON
DRAWN: /^ AP
✓/l�/
ONE INC"
DATUM
Plcnnin Buildingry Public Works Dept,
�/ y/
CHECKED: SLB
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
NO.
REVISION
BY
DATE
AP P R
APPROVED: LBS
ADDITIONAL TREES (TYP.)
10' STREET FRONTAGE LANDSCAPE BUFFER (TYP.)
ROOT BARRIER (TYP.);
SEE SHEET P7 FOR DETAIL
TREE (TYP.)
STREET TREE (TYP.)
GROUND COVER (TYP.)
SHRUB (TYP.)
I
I
I
I
SCALE: 1" = 10'
0 5 10 20
R-4 7 93 74
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING
Ming 01/27/2022
DATE:
NO V 2021
FIELDBOOK:
PAGE:
DRAWING NO:
L2.01
SHEET: 14 0F: / 5
STAKING NOTES:
RUBBER HOSE AT TREE; HOSE SHALL
BE LONG ENOUGH TO
ACCOMMODATE 1 YEAR'S GROWTH
AND BUFFER ALL BRANCHES FROM
THE WIRE
3 HARDWOOD STAKES OR OTHER
APPROVED MATERIAL; ALL STAKES
TO BE DRIVEN OUTSIDE THE
ROOTBALL, AT 120- SPACING
GALVANIZED WIRE OR CABLE; TWIST -
WIRE TO TIGHTEN ONLY ENOUGH TO
KEEP FROM SLIPPING (ALLOW FOR
SOME TRUNK MOVEMENT)
3.01
e
• e%le e e O••.
Oe e
e °
ee
•
0
°°ee
°
°
ee e ae
• •e
e °e••
•e
e ° "• •• • • •• ° i• e
•e ° o.
e e • e
• e ee,•
• °O••
1,•e%
'• '
-----------------
�
•1
v00000��...�000.�0000c
.0000000000000000�.ima
ou�0000000000000.
�oiuu000�i�iuoo�iau�
IIIIIRI,lllpul u
STAKES SHALL EXTEND
A MIN. OF 1' INTO
UNDISTURBED SOIL
PLANT TREE SO THAT THE TRUNK
CROWN IS VISIBLE AT THE TOP OF THE
ROOTBALL; SET TOP OF ROOTBALL
FLUSH TO GRADE; DO NOT COVER THE
TOP OF THE ROOTBALL WITH SOIL
MIN. 2" MULCH; DO NOT PLACE IN
CONTACT WITH TRUNK
REMOVE ALL TWINE, WIRE AND
BURLAP FROM TOP HALF OF
ROOTBALL; NON
BIODEGRADABLE MATERIAL
SHALL BE REMOVED
COMPLETELY
4" HIGH EARTH SAUCER AROUND EDGE
OF PLANTING PIT
:Zfl1LNC1�►���IN�Y�1�]II
TAMP TOPSOIL BACKFILL
AROUND ROOTBALL BASE
FIRMLY WITH FOOT PRESSURE
TO AVOID SHIFTING OF
ROOTBALL
PLACE ROOTBALL ON
COMPACTED SOIL PEDESTAL TO
PREVENT SETTLING
2 x ROOTBALL DIA.
DETAIL: PLANTING DECIDUOUS TREE
NOT TO SCALE
PLANTING BEDS/UNDISTURBED UNDISTURBED TURF (LAWN) AREAS,
VEGETATION, SEE NOTE 1 SEE NOTE 1
UNDISTURBED 0"
NATIVE VEGETATION
UNDISTURBED NATIVE SOIL
OPTION 1 - NO DISTURBANCE
PLANTING BEDS
3"4" ARBORIST WOOD CHIP MULCH,
SEE STD. PLAN 262.60
3" OF COMPOST INCORPORATED
INTO 5" OF SITE SOIL (TOTAL
AMENDED DEPTH OF 9.5", FOR A
SETTLED DEPTH OF 8")
SUBSOIL SCARIFIED 4" BELOW
COMPOST AMENDED LAYER
(12" BELOW SOIL SURFACE)
0"
8"
TURF (LAWN) AREAS
GRASS: SEED OR SOD
UNDISTURBED NATIVE SOIL
GRASS: SEED OR SOD
1.75" OF COMPOST INCORPORATED INTO
6.25" OF SITE SOIL (TOTAL AMENDED DEPTH
OF 9.5", FOR A SETTLED DEPTH OF 8")
SUBSOIL SCARIFIED 4" BELOW
COMPOST AMENDED LAYER
(12" BELOW SOIL SURFACE)
OPTIONS 2, 3, AND 4 - AMEND IN PLACE OR STOCKPILE AND AMEND
PLANTING BEDS
3 4' ARBORISTWOOD CHAP///
MULCH, SEE STD.
PLAN 262.60 III III-1-1 I IJ-1 I-1 I-1
6" IMPORTED III=111=III=III=1=1=11(-
TOPSOIL MIX III=1 1=1 I1=1 I1=1 1=1 1=1 I1=1
(COMPACTED 11111111111111111111111111111111111111111111111
DEPTH)=1 1=1 1=1 1=1 1=1 1=1 1=1 6
III-1 I-III-1-1 n-1 1=1 I -
SUBSOIL IS
SCARIFIED 6"
BELOW IMPORTED
TOPSOIL MIX
/ �\ 7,
12"
OPTION 5 - IMPORTED TOPSOIL
,.o PUBLIC WORKS
VDEPARTMENT
TURF (LAWN) AREAS
GRASS: SEED OR SOD
NOTES:
1. AREAS OF NO DISTURBANCE TO BE FENCED
AND EXISTING VEGETATION AND SOIL TO BE
PROTECTED FROM CONSTRUCTION IMPACTS.
6" IMPORTED
TOPSOIL MIX
(COMPACTED
GENERAL NOTES:
DEPTH)
1. TO MEASURE SETTLED DEPTH, WATER SOIL
SUFFICIENTLY TO FULLY SATURATE WITHOUT
CAUSING EROSION
SUBSOIL IS
2. COMPOST TO MEET STD. PLAN 262.60.
SCARIFIED 6"
BELOW IMPORTED
3. COMPACTION OF TOPSOIL (WHERE REQUIRED)
TOPSOIL MIX
TO BE TO 85 % OF STANDARD PROCTOR.
4. SEE CONSTRUCTION PLANS FOR SPECIFIC
PROJECT REQUIREMENTS.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 264.00
APPR ED:
SOIL AMENDMENT SECTIONS GqZ 9/28/2018 1
Public Works Administrator DATE
DETAIL: SOIL AMENDMENT BM
CITY OF RENTON
PUBLIC WORKS DEPT.
C
12X
ROOTBALL
DIA.
C
ONE SIGN PER 50'
(MIN. OF 2 SIGNS)
"NO TRESPASSING,
PROTECTED TREES"
CITY OF RENTON
2 X ROOTBALL DIA.
DETAIL: PLANTING SHRUB
NOT TO SCALE
DRIP LINE
• 0
-
CRITICAL ROOT ZONE �L
PLANT
SET CROWN OF PLANT AT
FINISHED GRADE
2" LAYER MULCH;
TAPER TO CROWN
SAUCER 2" HIGH
FINISHED GRADE
ROOTBALL
TOPSOIL BACKFILL &
FERTILIZER
ROUGHEN ALL SURFACES
OF PIT
CUT NEW ROOT MASS TO
STIMULATE NEW ROOT GROWTH
UNDISTURBED NATIVE SOIL
12X
ROOTBAL
DIA.
GROUNDCOVER
2" LAYER OF MULCH; TAPER TO
CROWN
FINISHED GRADE
ROOTBALL
TOPSOIL BACKFILL & FERTILIZER
CUT NEW ROOT MASS TO
STIMULATE NEW ROOT GROWTH
UNDISTURBED NATIVE SOIL
2 X ROOTBALL DIA. 4
DETAIL: PLANTING GROUNDCOVER
NOT TO SCALE
PROTECTION MEASURES DURING CONSTRUCTION:
PROTECTION MEASURES IN THIS SUBSECTION SHALL APPLY FOR ALL TREES THAT ARE TO BE RETAINED ON SITE AND OFFSITE.
OFFSITE TREES CONTAINING DRIP LINES THAT ENCROACH ONTO THE SITE UNDER CONSTRUCTION SHALL BE CONSIDERED PROTECTED
TREES UNLESS IT IS DETERMINED THE ABUTTING PROPERTY OWNER IS IN COMPLIANCE WITH SUBSECTION C OF THIS SECTION,
ALLOWED TREE REMOVAL ACTIVITIES. ALL OF THE FOLLOWING TREE PROTECTION MEASURES SHALL APPLY:
A. CONSTRUCTION STORAGE PROHIBITED: THE APPLICANT MAY NOT FILL, EXCAVATE, STACK OR STORE ANY EQUIPMENT, DISPOSE OF
EXISTING TREE
ANY MATERIALS, SUPPLIES OR FLUIDS, OPERATE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES, OR COMPACT THE EARTH IN ANY
WAY WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED.
CONTINUOUS CHAINLINK
B. FENCED PROTECTION AREA REQUIRED: PRIOR TO DEVELOPMENT ACTIVITIES THE APPLICANT SHALL ERECT AND MAINTAIN SIX-FOOT
FENCING
(6) HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE
SURROUNDING THE TREE EQUAL TO ONE AND ONE -QUARTER FEET (1-1/4') FOR EVERY ONE INCH (1") OF TRUNK CALIPER, WHICEVER4
IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION TRACT. PLACARDS SHALL BE PLACED ON FENCING EVERY FIFTY FEET
- POSTS AT 10' O.C. MAX
(50') INDICATING THE WORDS, "NO TRESPASSING- PROTECTED TREES", OR ON EACH SIDE OF THE FENCING IF LESS THAN FIFTY FEET
(50') . SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES
SHALL BE FENCED ON FOUR (4) SIDES. IN ADDITION, THE APPLICANT SHALL PROVIDE SUPERVISION WHENEVER EQUIPMENT TOR
TRUCKS ARE MOVING NEAR TREES.
C. PROTECTION FROM GRADE CHANGES: IF THE GRADE LEVEL ADJOINING TO A TREE TO BE RETAINED IS TO BE RAISED, THE
APPLICANT SHALL CONSTRUCT A DRY ROCK WALL OR ROCK WELL AROUND THE TREE. THE DIAMETER OF THIS WALL OR WELL MUST
BE EQUAL TO THE TREE'S DRIP LINE.
D. IMPERVIOUS SURFACES PROHIBITED WITHIN THE DRIP LINE: THE APPLICANT MAY NOT INSTALL IMPERVIOUS SURFACE MATERIAL
WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED, UNLESS OTHERWISE APPROVED BY THE CITY (ORD.
5958, 12-9-2019)
E. RESTRICTION ON GRADING WITHIN THE DRIP LINES OF RETAINED TREES: THE GRADE LEVEL AROUND ANY TREE TO BE RETAINED
MAY NOT BE LOWERED WITHIN THE GREATER OF THE FOLLOWING AREAS: (1) THE AREA DEFINED BY THE DRIP LINE OF THE TREE, OR
(II) AN AREA AROUND THE TREE EQUAL TO ONE AND ONE-HALF (1-1/2) IN DIAMETER FOR EACH ONE INCH (1") OF TREE CALIPER. A
LARGER TREE PROTECTION ZONE BASED ON THE TREE SIZE, SPECIES, SOIL, OR OTHER CONDITIONS MAY BE REQUIRED. (ORD. 5676,
12-3-2012)
F. MULCH LAYER REQUIRED: ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED COMPLETELY AND EVENLY WITH A
MINIMUM OF THREE INCHES (3") OF BARK MULCH PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING. EXCEPTIONS MAY BE
APPROVED IF THE MULCH WILL ADVERSELY AFFECT PROTECTED GROUND COVER PLANTS. (ORD. 5676, 12-3-2012)
G. MONITORING REQUIRED DURING CONSTRUCTION: THE APPLICANT SHALL RETAIN A CERTIFIED ARBORIST OR LICENSED LANDSCAPE
ARCHITECT TO ENSURE TREES ARE PROTECTED FROM DEVELOPMENT ACTIVITIES AND/OR TO PRUNE BRANCHES AND ROOTS,
FERTILIZER, AND WATER AS APPROPRIATE FOR ANY TREES AND GROUND COVER THAT ARE TO BE RETAINED.
H. ALTERNATIVE PROTECTION: ALTERNATIVE SAFECUARDS MAY BE USED IF DETERMINED TO PROVIDE EQUAL OR GREATER TREE
PROTECTION. (ORD. 5676, 12-3-2012; ORD. 5841-6-12-2017)
DETAIL: TREE
PROTECTION FENCING
1 CITY COMMENTS SLB 11/20/'T BS SURVEYED:
DESIGNED:
DRAWN:
CHECKED:
N0. REVISION BY DATE I APPR APPROVED:
NOT TO SCALE
PLANT
SPACING PER
PLANT TYPE;
SEE SCHEDULE
NOTE:
TO AVOID LANDSCAPE INTRUSION INTO PATHS,
THE FOLLOWING PLANTING SPACING OFF -SETS
FROM EDGE OF ALL PATHS, DRIVES, ACCESS
ROUTES, ETC. SHALL BE MET:
GROUND COVER: 18"
SMALL SHRUBS (UNDER 3' TALL): 30"
MEDIUM SHRUBS (FROM 3TALL TO 6): 42"
LARGE SHRUBS (OVER 6' TALL): 48"
DETAIL: PLANT SPACING
NOT TO SCALE
PLANTER STRIP
NOTES:
1. INSTALL PRODUCT PER MANUFACTURER'S SPECIFICATIONS.
2. INSTALL PRODUCT A MINIMUM OF 3' BEYOND CENTER OF TREE IN EACH DIRECTION PARALLEL TO
UTILITY LINE.
3. ALL TREES LOCATED WITHIN CLOSE PROXIMITY TO UTILITIES TO RECEIVE ROOT BARRIER.
DETAIL: ROOT BARRIER
PROJECT NO. 21019
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
DESIGN SURVEYING
12700 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
NOT TO SCALE
R-4 7 93 7 5
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING
JDing 01/27/2022
LBS
VV
Xnn
SCALE: KMP
HORIZONTAL: D 1988991
DATU M
•
� C T Y OF
RENTON
•
Planning/Building/Public Works Dept.
LA1U ISC� DETAILS Y S
/
NOV
lVOV 2021
FIELDHOOK:
DRAWING
ONE INCH
NO
L2.31
SLB
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
LBS
SHEET: 15 OF: