Loading...
HomeMy WebLinkAboutR-411505d- 0 d- J03NTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS USE STAPLES, WIRE RINGS. OR EQUIVALENT TU ATTACH FABRIC TO POSTS TA2" 14 GAUGE WIRE, OR91 EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC I 2,K IN. I1-11 POST SPACING MAY BE ENCREASE77 4"x4' MIN. TRENCH i I 12' MIN. TD a' IF WIRE BACKING FS USED I� BACKFILL TRENCH WITH NATIVE SOIL OR V4" TO 1.112" WASHED GRAVEL 2'Srot" WOOD POSTS, STEEL FENCE POSTS, OR EQUNrALENT (TYP.) NOTES: I. CONDI '"SOFUSE ,. SILT FENCE MAY BE USED DOWNSLOPE OF ALL OtSTURBED AREAS. 2. SILT FENCE IS NOT INTENDED TD TREAT CONCENTRATED FLOWS. NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW, ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP DR POND, :-E51GN AND INSTALLATION SPECIFICATIONS L.1- THE OEOTEKTRE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. AOS (ASTM D4751 } 2D-1D0 SIEVE SIZE (D.gD-1).15m ) FOR SILT FILM So-t00 SEVE SIZE (0.30-0.15mm) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM P4181) D.D2 SEC' MINIMUM GRAB TENSILE sTkEIYGtH (ASTM 04632) 180 LBS. MIN. FOR EXTRA ST'i2ENGTH FABRIC 100 LBS, MN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4932) 30%MAIL_ (WOVEN} ULTRAVIOLET RESISTANCE (ASTM O4355) 70% 61% -,.2. STANDARD STRENGTH FABRIC REOUINES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER. POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. -.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SWILL NOT BE STEEPER THAN 211:1 V 24. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4'X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM a INCHES DF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5. FILTER FABRIC FENCES SHALL BE INSTALLEO ALONG CONTOURS WHENEVER POSSIBLE. 3- MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY 3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP DR POND. 3.3. IT IS IMPORTANT TD CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNEUZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS. REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENrT. 'i.4. SEDIMENT MUST BE REMOVED WHEN SEDIMENT LS 8 INCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN. FT SHALL BE REPLACED. UNLESS QTHERWISE NOT113, DRAWING IS NOr TO 50ALt [NT* URIPUBLIC WORKS DEPARTMENT Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 - Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. - Cle Elum, WA 98922 - Phone: (509) 674-7433 :45 Alk S. E. 114 OF N. E. 114 OF SECTION 14, T. 23 N., R. 05 E., W- M. CITY OF RENTON, STATE OF WASHINGTON �K15rttiPL0�01� R 25' MIN. INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT, AS PER CITY kOAb StANDARD5 4W QUARRY SPALLS --' GEOTEXTILE 12" MIN. THICKNESS 1D0' MIN. I DRIVEWAYS SHALL BE PAVED TO THE EDGE OF THE RIGHT-OF-WAY PRIOR TO INSTALLATION OF THE OON$TRUCITON ENTRANCE To AVOID DAMAGING OF THE ROADWAY. 2. IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD 15, MIN PROVIDE FULL WIDTH OF LNGRESSIEGRE:SS AREA NOTES: 1: P,.QNPRION i];=USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAV;NG A CONSTRUCTION sr-E AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE 12 FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE Ito ADDITION TO THE MAIN SUBDIVISION ENTRANCE. STABILIZED SURFACES &HALL BE OF SUFFICIENT LE14GTHWDTH TO PROVIDE VEHICLE ACCESSrPARKENG- BASED ON LOT SIZElCONFIGURATION. 2. DESV k AND INSTALLATION SPECIFICATIONS 2.1. A SEPARATLON GEOTEXTILE SHALL 13E PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILE SHALL MEET THE FOLLOWING STANDARDS" GRAB TENSILE STRENGTH (ASTM D4632) 200 -BS. MIN GRAB TENSILE ELONGATION (ASTM D4M) 30% MAX, (WOVEN) CSR PUNCTURE STREN07H (ASTM DVOI 495 LBS. MIN AOS (ASTM D4751) 20-45 (U.S- STANDARD SIEVE SIZE) >.2. DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE I H LEVELS IN GTORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE M PROHIBITED. 2.S. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS. NDG FUEL IS NOT RECtiMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS- THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDEMENT FROM BEING TRACKED ONTO PAVEMENT OR I F THE HOG F UEL IS BEING CARRIED ONTO PAVEMENT. 2.4. FENCING 5HALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE 2.5. WHENEVER POSSIBLE. THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE, THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3, VAENTENANCESTANDARDS 3.1. QUARRY SPALLS SHALL AE ADDED IF THE PAD IS NO LONGER IN ACCORDANMVVIT+1 THE SPECIFICATnNS. 32 IF THE ENTRANCE IS NOT "EVENTING SENIVENt FROM BEING TRACKED OWO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE 0= SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE. OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED. IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED R9GK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET. EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE 1T CAN BE CONTROLLEI7 AND DI8GWRGE11 APPROPRIATELY. WASH WAFER MUST 8E PUMPED RACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 3 Y Y T A AR N FROM THE P AN EN P THEROADWAY S I Y ,4 AN QUARRY SPALLS H T - E LDDSE ED DMI E AD P P U ON THHALL 13E REMOVER IMMEDIATELY 5. IF VEHICLES ARE ENTERING OR EXITING THE $rrES AT PAINT$ OTHER THAN THE CONSTRUCTION ENTRANCE($}, FENICJNG $HALL BE INSTALLED TO CONTROL Tway=Flc, UNLESS OTHERWISt No-mv, pRAW FNG 15 NOr TO 50AL� INTSE - STD, PLA- z15.10 DEPARTMENNTT N PPRQV ED" UR) PUBLICwOSTABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 I P„11. wIL, DATA xrL :45 Al �5'MAk DRAINAGE GRATE TRIM GRATE FRAME _ — OVERFLOW BYPASS Y BELOW INLET GRATE DEVlC£ SEDIMENT AMC) DEBRIS' " FILTERED WATER SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATESHOWN) RETRIEVAL SYSTEM (TYP,) OVERFLOW BYPASSITYP.) BELOW INLET GRATE PWCE ISOMETRIC VIEW NOTES: 1. PROTECT,ON SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS POWNSLOPE AND WITHIN 500 FEET OF A 131STURBED OR CCN5TRUCTICN AREA. UNLESS THE RUNOFF THAT ENTER$ THE CATCH BASIN WILL BE CONVEYED 71) A SEDIMENT POND OR TRAP 2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 9. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE 4, SIZE THE BELOW INLET GRATE DEVICE IBIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE- 5- THE BIGO SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM(OVERFLOW BYPASS} THE RETRIEVAL RY M 5T ALLOW REMOVAL F THE RleD OUT SPILLING THE COLLECTED ATERIAi- 9. RETR STEM U O WITH M R WITHSPECIFICATION 1. 7 PE FURN4 MAINTENANCE IN AGGI3RQANGT= STANDARD A-D 3 15). } B, ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY, UNLESS QTHERWISt NOT113, DRAWING IS NOr m 50ALt INTSI STD. PLIaN - 216.30 �� PUBLIC WORKS APPN ED "e ♦ DEPARTMENT ENT CATCH BASIN INSERT GAG 9/28/2018 P-1, w— DATr View Looking Upstream q 12' �1s•� (0-6m) (150mm) Note: Key stone into channel banks and extend h beyond the abulments a minimum of 18" (0.5m) to prevent now around dam. A Section A -A Flow a— 24- (0.6m) _ c V (2.am) Spacing Between Check Dams 'L' = the distance such that points 'A' and'B' are of equal elevation. L' Point'A' NOT TO SCALE Rock Check Dam Revised June 2016 DEPARTMENT OF ECOLOGYPlease see http.'/Avww-ecywa.goWcopyrighthtml for copyright notice including permissions, State of Washington IimNation of liability, and disclaimer. `0, -rr/r� ;� SURVEYED: SDM DESIGNED: 3 REVISIONS PER CITY COMMENTS DATED 612312021 CP 0710112021 NEM b �� 1,O 38375 2 REVISIONS PER CITY COMMENTS DATED 410712021 CP DRAWN: TL1< REGISTER �� 1 REVISIONS PER CITY COMMENTS DATED 1/25/2020 PMD �/1�/2020 CHECKED: ZONAL 07/01/2021 N0. REVISION BY DATE APPR EDM APPROVED: CA SCALE: 1" 30) ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM : 4 5 AI Lath and flagging on 3 sides 3endbag term 10 mil plastic linklg A Plan 1m Berm Section A -A Type "Below Grade" P Stake (typ-) 1rl plastic lining Sandbag 1, Actual layout determined in the field, 2. A concrete washout sign shall be installed With111 16 m of the, temporary eoncrote washout facility. Wood Frame securely Hastened around entire peri"ter With tV stakes 10 mil pias#ic IIn[no Section B-B 2x12 rough Plan wood Frame Type "Above Grade" with Woad Planks NOT TO SCALE Concrete Washout Area with Wood Planks Revised June 2016 [DEPARTMENT OF ECOLOGY O OGY pi,.,, p.y. .winpyrig►t hhJ for copyright notcc including per isslons , State as Washington, limilationoflabift,and disdaimer. Al Y One sign per 50 feet. (minimum of 2 signs) Dripline r-rftic$I ^ — ~ f Root Zoo x0 Ft. I I f f f I 2 , I 6 Ft. Temporary I Chain Link Fence tc_ Ixx,Ts NO TRESSPASSING PROTECTED TREES Figure 1. TREE PROTECTION FENCE DETAIL. DRIPLINE METHOD Know what's below. Call before you dig. CITY OR RENTON I;R Planning/Building/Public Works Dept. R-41 1505 S A IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Brianne Bannwarth 07/01/2021 ' c SKYHORSE SHORT PLAT PR 17— 000438 TESC DETAILS O Z DATE: Lu 1111212020 C� FIELDBOOK: PAGE: O DRAWING NO: 14603 SHEET: OF 5 : 19