Loading...
HomeMy WebLinkAboutR-411511OUNTY KING 0 0 5 10 - _ _ ECE = o / / / SCALE 1 " 10 . CB 16, TYPE. 1 . / W1 V NED GRATE 99 I / ----- �- PER COR STD 204.2 I \ _ .\ \ _ STA: 9�1-63.34, I Z22 . 9 9. �i W . , _ I / / - - - - _ - d� > ° ° RIM: 932.17 460 IE=46?:08 12" . (E) . ���- E=462.08 12" (W) �. ° ° \ \ ° CB 17, TYPE 1 E / Q � ° W/ VANED GRATE � . - . U J \ PER COR STD 204.2 T 462 CL STA:10+45.36, 12.21' RTNjo \ . RIM:464.09 9 IE=460.40 8" (SW) , / 9 A �64 y 9 a �. .201.� I �0- -� /I 51 LF 8" PVC SD_, C I 1 I 0 0.80% d 95 59 LF 12" PVC L1J SU 0-0.50%� - - _ - X 5'x10' REMOVAB � - - - - 36 LF 12" PVC MAINTENANCE ACCESS FINISH GROUND ®_ PROFILE I _ SD 3.35% � I � � ��f � � IFINISH FLOOR =464.0E 0 r 99 i s O I I . 20 x 9 / • I 6 _ x 9•5 TOP OF VAULT - 463.00 i d � ir-MION WA TER IE=455.85 QUALITY q � C CB #4, TYPE 1 I I B VAULT W/ BI-DIRECTIONAL VANED I I I I I GRATEI PER COR STD 204.3 STA: 2Qt53.91, 12.22' RT I . IE=454.85 - - -- -- - -- B RIM:464.84 I 4 I IE=455.33- IE=459:84 12" (E) I \- - IE=459.84'12" (N) �� - -' - 1 - - - 4 9 9 I \ - --- --- - - -- I 24 LF 12" PVC I I I' 99' " 10.00' PRIVATE STORM SD 00. 77 � Q I 38 ' LF 12 PVC \ \ O EASEMENT Q0 12" VENTILATION PIPE \ � - VA _ MANHOLE RING AND \ WITH REMOVABLE CAP I I I \ - - I I 5'x10' REMOBLE - - - - - - ACCESS LID (TYP) \ I 11 \ MAINTENANCE ACCESS A I- - - WSE = 461.35 - 5.5' LIVE STORAGE WSE = 455.85 ♦ 3.5' DEAD STORAGE +_ WSE = 452.35 5z r r a ♦ 99 LLICB W/ B D REC710N" VANED - - IE=461.65 I �J LLJ/ - - - .\ � d 4 � GRATE I ��, � -- i------- \ O DER Colt STD 204.3 i - - - - - - - C� i DETENTION/ WATER QUALITY VAULT NORTH SECTION A -A o DETENTION /WATER QUALITY VAULT (NORTH) PLAN , > (NORTH) //\/ /\\/\\/\\/\\/\\/ \//\//\//\//\//\//. HANDHOLDS, STEPS OR LADDER 12" MIN. SEPARATION 12" 12" (OUT) IE=455.85 R BOTTOM OF VAULT = 451.22 SCALE: 1 =1UN; 5 V 5'x10' REMOVABLE SCALE: 1 "=10' �\ MAINTENANCE ACCESS FINISH GRADE = 464.0t 5'x10' FINISH GROUND " Cj- TOP OF VAULT = 463.00 d WSE = 461.35 Q ORIFICE12 8---*.----_DOWN-TURNED ELBOW 5.5' LIVE STORAGE IE=458.85 DIA.=3/4" 12" FLOW CONTROL RISER PER COR STD. PLAN 237.0 CLEANOUT W/8" SHEAR GATE WSE = 455.85 PIPE SUPPORT 3" x .90 GA. BOLTED OR IMBEDDED 2" IN WALL AT MAX. 3' SPACING 3.5' DEAD STORAGE ORIFICE11 ON BOTTOM PLATE IE=453.85 DIA.=3/4" WSE = 452.35 1' SEDIMENT STORAGE Q 4 1 V d .d CONTROL STRUCTURE DETAIL SCALE: 1 "=2'H; 2'V Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 • Phone: (509) 674-7433 �y II WAS P 3 REVISIONS PER CITY COMMENTS DATED 612312021 38375 � 2 REVISIONS PER CITY COMMENTS DATED 410712021 11sT � ��� 1 REVISIONS PER CITY COMMENTS DATED 112512020 SIGNAL 0710112021 NO. REVISION 12" (IN) IE=454.85 SURVEYED: SDM DESIGNED: NEM CID 0710112021 CID 0410812021 DRAWN. TLK PMD 1111212020 CHECKED: EDM BY DATE AP P R APPROVED: CJA REMOVABLE PROFILE 12 VENTILATION PIPE MAINTENANCE WITH REMOVABLE CAP ACCESS r FINISH FLOOR = 464.0t TOP OF VAULT = 463.00 0.5' MIN. FREEBOARD A - e ♦ a a ♦ e 57 WSE = 461.35 = _ HANDHOLDS, STEPS OR LADDER 12" MIN. SEPARATION - 5.5' LIVE STORAGE 36, CIP CONCRETE _ 3' DEEP BAFFLE WSE = 455.85 _I _ 3.5' DEAD STORAGE ---..-..-.WSE=452.35 ----- �.----. 0.5% 2' MIN. 0.5% f- -� A DETENTION / WATER QUALITY VAULT (NORTH) SECTION B-B SCALE: 1 "=10'H; 5'V SCALE: 1 "=10' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM R-411509 • IN COMPLIANCE WITH CITY OF RENTON STANDARDS J ® DEVELOPMENT ENGINEERING ' IL orBrianne Bannwarth 07/01/2021 ' O Know what's below. _ Call before you dig. (J-) DATE: CITY OF SKYHORSE SHORT PLAT 1111212020 c/� FlELDBOOK: [;R R E N TO N PR 17-000438 PAGE: ' 9 TRACT 0 DRAWING N0: Planning/Building/Public works Dept. STORMWATER DETENTION / WATER QUALITY VAULT 1460.3 SHEET: OF. 1 1 19 J