Loading...
HomeMy WebLinkAboutR-4115153 TRENCH WIDTH, SEE NOTE 3 PIPE ZONE BEDDING AND T BACKFILL, SEE NOTE 4 1 6" V//rz OD FOUNDATION LEVEL 6' FOUNDATION MATERIAL, IF REQUIRED. SEE NOTE 5 CIRCULAR PIPE FRENCH WIDTH, SEE NOTE 3 PIPE ZONE BEDDING AND SPAN S" BACKFILL. SEE NOTE 4 T{ I RISE FOUNDATION LEVEL r FOUNDATION MATERIAL V IF REQUIRED. SEE NOTE VY PIPE • ARCH RIGID PIPE NOTES: i PIPE COMPACTION LIMITS SHOWN ON THIS PLAN ARE FOR PIPE CONSTRUCTION IN AN EMBANKMENT. FOR PIPE CONSTRUCTION IN A TRENCH, THE HORIZONTAL LIMITS OF THE PIPE COMPACTION ZONE SHALL BE THE WALLS OF THE TRENCH. 2- O.D. IS EQUAL TO THE OUTSIDE DIAMETER OF A PIPE OR THE OUTSIDE SPAN OF PIPE -ARCH. 3 SEE STANDARD WSDOTlAPWA SPECIFICATIONS SECTION 2-09.4 FOR TRENCH WIDTH 4 PIPE ZONE BEDDING AND BACKFILL MATERIAL SHALL BE PLACED IN 6' LOOSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY. 5 EXCAVATE UNSTABLE MATERIAL DOWN TO FIRM SOIL AND REPLACE WITH FOUNDATION MATERIAL CLASS A OR B PER STANDARD WSDOTIAPWA SPECIFICATIONS SECTION 9-03 17 I7-7� GRAVEL BACKFILL FOR PIPE ZONE BEDDING (WSOOT 9-03.1213)) / / OR MAINTENANCE ROCK (WSDOT 9-03.90)) MINIMUM ALLOWED IN ZONE 1 PIPE TYPE COVER (FT) PUBLIC? PRIVATE? OF THE APA? CORRUGATED 20 YES YES YES STEEL PIPE SPIRAL RIB STEEL 20 YES YES YES PIPE PLAIN CONCRETE PIPE (PCP) 20 NO YES NO REINFORCED CONCRETE PIPE 1.0 YES YES NO (RCP) CORRU SPRAL .ZrRIB 2.0 YES YES NO ALUMINUM PIPE DUCTILE IRON PIPE 1.0 YES VES YES CIRCULAR PIPE DIAMETER MINIMUM DISTANCE BETWEEN BARRELS 12' TO 24" 12' 3D" TO W DIAMETER l3 102-TO 180, 48• PIPE -ARCH SPAN MINIMUM DISTANCE BETWEEN BARRELS T8"TO38' 12" 4r TO 147 SPAN 13 148" TO 199" 48' UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTSI STD. PLAN - 220.00 ..� PUBLIC WORKS PIPE ZONE BEDDING AND APPROVED DEPARTMENT COMPACTION - RIGID PIPE GAZ 9/28/2018 DATE PLANTING BEDS)UNDISTURBED UNDISTURBED TURF (LAWN) AREAS, VEGETATION, SEE NOTE 1 SEE NOTE 1 +II�R�i�411,1��1II�l����I�41I1' UNDISTURBED {� GRASS. SEED OR SOD NATIVE VEGETATION I�'-i.>� I �" I I UNDISTURBED NATIVE SOIL 3"-4' ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.00 3"OF COMPOST INCORPORATED INTO 5" OF SITE SOIL (TOTAL AMENDED DEPTH OF 9.5', FOR A SETTLED DEPTH OF 8') OPTION 1 - NO DISTURBANCE PLANTING BE r) TURF (LAWN) AREAS 0" B' UNDISTURBED NATIVE SOIL GRASS. SEED OR SOD 1.75" OF COMPOST INCORPORATED INTO 6.25" OF SITE SOIL ITOTAL AMENDED DEPTH OF 9.5', FOR A SETTLED DEPTH OF 8'1 SUBSOIL SCARIFIED4' BELOW SUBSOIL SCARIFIED 4" BELOW :L- +1 COMPOST AMENDED LAYER COMPOST AMENDED LAYER "s-H - 1�A i try (12' BELOW SOIL SURFACE) iV (12- BELOW SOIL SURFACEI OPTIONS 2, 3, AND 4 - AMEND IN PLACE OR STOCKPILE AND AMEND PLANTING BEDS TURF (LAWN) AREAS 0' WOOD CHIP ///, GRASS SEED OR $OD MULCH, SEE STD. 11 D. PLAN 262.60 ; 1 L I NOTES: - 1. AREAS OF NO DISTURBANCE TO BE FENCED AND EXISTING VEGETATION AND SOIL TO BE PROTECTED FROM CONSTRUCTION IMPACTS 6"IMPORTED - I 6"IMPORTED TOPSOIL MIX - I - - I I I I y-I - TOPSOIL MIX I I' ---� I GENERAL NOTES: (COMPACTED I III I I (COMPACTED I DEPTH) I I I I I (� 8- I I I I I I DEPTH) I TO MEASURE SETTLED DEPTH, WATER SOIL SUFFICIENTLY TO FULLY SATURATE WITHOU t all: CAUSING EROSION r 1� SUBSOIL IS 2 COMPOST TO MEET STD. PLAN 262.60- Ir_-' SUBSOIL IS C - -_ SCARIFIED 6" = BELOW IMPORTED 3. COMPACTION OF TOPSOIL (WHERE REQUIRED, SCARIFIED 6' „_I_ 7 -T, TOPSOIL MIX TO BE TO 85% OF STANDARD PROCTOR. BELOW IMPORTED - 1 _I TOPSOIL MIX 4, SEE CONSTRUCTION PLANS FOR SPECIFIC 12' i PROJECT REQUIREMENTS OPTION 5 -IMPORTED TOPSOIL UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTSI STD. PLAN - 264.00 WORKS APPR D: URIPUBLIC SOIL AMENDMENT SECTIONS GAZ 9/28/2018 DEPARTMENT DATE Lncompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 • Phone: (509) 674-7433 :45 AI T4" FLAT FACE GOTHIC y I_ T DIA --I on o It 5 STORM ❑ r nnnn T -1gt9116"DIA tin t $-11B" D W 10.IlI DIA Q) 30•16 SS SOCKET HEAD CAP 15" DIA { 1) OPEN PICKHOLE SCREW {ALLE NHEAO} WANSHRS ON A S' DIA BOLT CIRCLE PLAN VIEW FRAME SECTION COVER SECTION CAST IRON FRAME AND PAVED AREA (TYP-) COVER- SEE NOTE 3 'r --mil 12• EXTEND CLEANOUTRISER 2" ABDVf DESIGN SIGNPONOING IF+ _ I�•---� ELEVATION OR PER PLAN FERNCO GASKETED QUIK CAP OR SIMILAR - DESIGN POHDING .. ... ELEVATION 4' STREAMBED COBBLES 8" CLASS'S' PER WSDOT 9-03.1 T(2) ASPHALT, SEE NOTE 4 '. A' COMPACTED SAND OR GRAVEL BAOKFILL FOR DRAINS PER WSDOT 943.12{4) CLFANOUT RISER, SEE NOTE 2 J CLEANOUTRISFRjl SOIL TIGHT 45' BEND SEE NOTE 2 - WYE i I SOIL TIGHT COUPLER Ii I UNDERDRAIN, FOOTING DRAIN COLLECTOR. OR ROOF GRAIN COLLECTOR PIPE, SEE NOTE 1 CLEANOUT RISER LOCATED WITHIN �j 610RETENTION PONDING AREA 1 TO OVERFLOW J STRUCTURE ORb- STORM LH41N' MECHANICAL PLUG OR CONTINUED CONNECTION TYPICAL CLEANOUT CONFIGURATION NOTES: 1. DIAMETER TO BE &INCHES MINIMUM PRNATF- &INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 202.10- 2. CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN. FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. 3. FRAME AND COVER SHALL 9E EJ PRODUCTS M7EZIPT AND MMAPT CR APPROVED EQUAL COVER TO 9E LOCKING WITH ALIEN HEAD BOLT, MARKED'STORW OR 'DRAIN'. 4. FOR CLEANOUTS FULLY OR PARTIALLY WITH IN UNPAVED AREAS OUTSIDE OF EIIORE7ENT14N PONDING AREA, POUR 8" THtCK, Zx2' SQLIARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3.EIW PSI. GENERAL. NOTES: 1. CLEANOUTS FOR UNDERORAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAI N COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND. AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERORAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MANNTENANCE ACCESS TO ALL PIPES. 2_ ALL FITTINGS SHALL BE SOIL TIGHT. 3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF WORETENTION PONDING INHERE POSSIBLE. 4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY. UNLESSOTHERWI5E NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 226.00 PRIPUBLIC WORKS Y: DEPARTMENT STORM SYSTEM CLEANOUT actin Pastucha 8/13/20 1 DATE *-00- 1.5" RADIUS L (TYP.) 1 �A D E 0.3" BORDER (TYP.) 0 0 0 0 0 0 O O A i 0 01 0 D L' SIGN DIMENSIONS SIGN TYPE A B C D E POST MOUNTED STREET NAME SIGN (SPEED LIMIT <40MPH) 8" VARIES 6" 4.5" 3.5" POST MOUNTED STREET NAME SIGN (SPEED LIMIT >40MPH) 12" VARIES 8" 6" 5" GENERAL NOTES: 1. FONT SHALL BE MUTCD D SERIES, UNLESS AN ALTERNATE MUTCD SERIES IS APPROVED BY THE CITY 2. LETTERS AND NUMERALS SHALL BE CUT FROM 3M ELECTROCUT FILM SERIES 1170 OR APPROVED EQUAL 3. SIGN BLADE SHALL BE FLAT ALUMINUM, TREATED, 0.080 GAUGE 4, SIGN SHEETING SHALL BE 3M HIGH INTENSITY PRISMATIC OR APPROVED EQUAL 5. SIGN MOUNTING HARDWARE SHALL INCLUDE BOLTS, RIVETS SHALL NOT BE ALLOWED 6. FOR SIGN POST DETAILS, SEE CITY OF RENTON STANDARD DETAIL 129, EXCEPT MOUNTING HEIGHT SHALL BE 9'-0" COLORS LEGEND, ARROW HEAD, SEPARATION BAR - WHITE (REFL.) BACKGROUND - GREEN (REFL.) POST MOUNTED TD. PLAN- 134 PUBLIC WORKS STREET NAME SIGNS DEPARTMENT ROVED: 7/30/2018 DATE '�pHIL �F WAS 3 REVISIONS PER CITY COMMENTS DATED 612312021 38375 �� 2 REVISIONS PER CITY COMMENTS DATED 410712021 �EcrST 1 REVISIONS PER CITY COMMENTS DATED 112512020 ssIONAL �yG 0710112021 NO. REVISION T MIN, CLEARANCE TO ANY PORTION #FLOW RESTRICTOR TEE INGLURINfl ELBOWS REMOVABLE WATERTIGHT COUPLING OR A FLANGE 2' MIk. A � ELBOW RESTRCFOR, SEE DETAIL AND NOTE 10 ` 1 1 ANGLE AS X i^� NECESSARY. SEENOTE7 6' MIN 2' MIN. '--� ADDITIONAL LADDER RUNGS [IN SETS) TO ALLOW ACCESS TO TANKS OR VAULTS WHEN CATCH IS FILLED WITH WATER 6' MAX. 1 7 WELDED TO ELBOW WITH PLAN VIEW E AS SPECIR ED. SEE ROTE 3 ELBOW RESTRICTOR DETAIL ELEVATION PER PLANS 12" MIN. LINGER FRAME 3 SOLID COVER MARKED "DRAIN' WITH PAVEMENT LOCKING BOLTS PER STD. PLANS 204.40 AND 204,50 77 16" MAX. . I VERTICAL BAR GRATE>=0R SECONDARY INLET S' MIN. DESIGN WATER ELBOW RESTRICTOR, SURFA - SEE DETAIL AND NOTE SO HANDHOLDS, STEPS, OR LADDER PIPE SUPPORTS, SEE NOTE 6 l2" ETYP, ) 1.5 x ❑ SEE NOTE 9 {TYP.) MIN 2MIN. T� I ISOMETRIC i OUTLET PIPE, SEE INLET PIPE NOTES t & 5 2' MIN. SHEAR GATE WITH CONTROL ROD POR INVERTAND CLEA NOUT+ORWN (ROD BENT AS REQUIRED ELEVATION PER PLANS FOR VERTICAL ALIGNMENT WITH CQVER) 12• SECTION OF PIPE ATTACHED BY PER STD. PLAN 237.30 GASKETED BAND TO ALLOW REMOVAL 2' 12. MIN. WELDED RESTRICTOR PLATE WITH ORIFICE DIA AS SPECIFIED, SEE NOTE 10 NOTES: SECTION A 1 USE A MIN IMUM OF A 54' DiAMETER TYPE 2 CATCH BASIN 2. OUTLET CAPACITY: 10¢YEAR DEVELOPED PEAK FLOW. 3. METAL PARTS PREFERRED TO BE STAINLESS STEEL. ALUMINIZED STEEL. OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2. OR S 4. FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP S. CLIMB -DOWN SPACE IS CLEAR OF R1SEA AND OLEANOUT GAT@. C- FRAME iS cLEAR OP CURS. 5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE- OUTLEF PIPE TO HAVE SMOOTH 0. D- EQUAL TD CONCRETE PIPE I-D. LESS 1.,4' 6. PROVIDE AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. IMAXIMUM 3'-O' VERTICAL SPACING). 7 LOCATE ELBOW RESTRiCTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN 8 LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER. 9. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PI Pr- 10. IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED. U NLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 237.00 WORKS FLOW CONTROL STRUCTURE - �° URIPUBLIC DEPARTMENT RESTRICTOR TEE[Martin Pastucha 8/13/20 39afftc WPA89D . DATE MUTCD SIGN R8-3 (MODIFIES) NPAT = NO PARKING ANYTIME *ORIENT NO PARKING SIGN AT 45 DEGREES FROM STREET NOTE NO PARKING SIGN TO BE BANDED TO STREET LIGHT POLE (WHERE APPLICABLE) BANDS TO MATCH STREET LIGHT POLE COLOR; 100' SEPARATION BETWEEN SIGNS USE DOUBLE ARROW NO PARKING SIGN AT ALL LOCATION EXCEPT ON STOP SIGN. USE RIGHT ARROW ONLY NEAR STOP SIGN. SURVEYED: SDM DESIGNED: NEM CP 0710112021 CP 0410812021 DRAWN. TLK PMD 1111212020 CHECKED: EDM BY DATE APPR APPROVED: CJA SCALE: 1 "=30' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 0 18' MAX. PROM CENTER OF FRAME TO STRUCTURE WALL FOR STEP ACCESS WETPOOL WIDTH INLET FRAME AND SOLID COVER MARKED"DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 - FIRST CELL SIZED FOR 25% TO 35% OF WETPOOL VOLUME INLET ACCESS COVER OR DOORS REQUIRED. 510T GRATE. CRATED ACCESS DOOR, OR LOCKING ACCESS PANEL OVER SECOND CELL. FOR VAULTS WHERE SURFACE AREA OF SECOND CELL IS GREATER THAN 125D SQUARE FEET, 4%OF THE TOTAL SURFACE AREA MUST B�F GRATED AND A T.W. REMOVABLE LOCKING PANEL SHALL BE PROVIDED OUTLET - LADDER SHAPED 50TTDM Ll B" MIN. GRAVITY DRAIN REMOVABLE BAFFLE OR WALL. SEE NOTE 2 SEE NOTE 7 (TYP.) S' MAX. FROM COVE OF OPENING TO STRUCTURE .• .- .- .- WALL FOR STEP ACCESS WETPOOL LENGTH 12' MI14, VENTILATION PIPES AT CORNERS (TYP.), SEE NOTE B a MIN. PLAN VIEW - 1 S" MAX. I SIZE TO CONVEY TOO -YEAR LADDER DESIGN FLOW WITHOUT SHEAR GATE OVERTOPPING.6" MIN. WATER QUALITY NO) DESIGN 12• MIN WATER SURFACE (WS� .__. OUTLET WITH CAPACITY TO - CONVEY 100-YEAR DESIGN --f 12" MIN. - FLOW WITHOUT OVERTOPPING WETPOOL DEPTH - SEE NOTE T (TYP,} v MAX - 3' MIN. REMOVABLE I BAFFLE 2' MIN. VRLVE GRAVITY DRAIN (IF GRADE ALLOWS). PLACE AS LDW AS GRADE ALLOWS BUT MUST BE B' MIN- ABOVE THE BASE ELEVATION OF VAULT BOTTOM SLOPE 0.5%-2Ye WALLS OR ABOVE SEDIMENT STORAGE AREA TOWARD INLET END B ❑ E D-5'I T OUT SECTION A BOTTOM Pz�s TOWARD GW ET L AVERAGE SEDIMENT STORAGE END OF SECOND CELL (RECOMMENDED) 12' MIN. IFIRST CELL) ACCESS DOORS OR REMOVABLE PANEL- SEE NOTE 5 WD DESIGN INS '7- T MIN. 4' MIN. 5% MIN. ITYP •) AVERAGE 12' SEDIMENT ' NOTES: STORAGE IFERST CELL} SECTION B T. THIS DETAIL IS A SCHEMATIC REPRESENTAT34N ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA 2 THE VAULT SHALL BE SEPARATED INTO TWO CELLS BY A WALL OR A REMOVABLE BAFFLE. IF A WALL OR NON REMOVABLE BAFFLE IS USED, A 5-FDOT X 10-FOOT REMOVABLE MAINTENANCE ACCESS MUST BE PROVIDED FOR BOTH CELLS. 3 FOR VAULTS UNDER ROADWAYS, THE REMOVABLE PANEL MUST BE LOCATED OUTSIDE THE TRAVEL LANES. ALTERNATIVELY, MULTIPLE STANDARD LOCKING MANHOLE COVERS MAY BE PROVIDED- SPACING OF MANHOLE COVERS SHALL BE 12 FEET, MEASURED ON CENTER. TO FACILITATE REMOVAL OF SEDIMENT. LADDERS AND HANO•HOLDS NEED ONLY BE PROVIDED AT THE OUTLET PIPE AND INLET PIPE 4. MINIMUM DIAMETER FOR ALL ACCESS OPENINGS, EXCEPT THOSE COVERED BY REMOVABLE PANELS, IS 38 INCHES. 5. REMOVABLE PANEL SHALL BE AT GRADE, HAVE STAINLESS STEEL OF I ING EYES, AND WEIGH NO MORE THAN 5 TONS PER PANEL- 6 VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATLON PIPES. VENTILATION PIPES SHALL BE CAPPED DR OTHERWISE COVERED, SUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION. 7. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (NOR-NSEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. B. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REOU IREMENTS. UNLESS DTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTSI STD. PLAN - 249.20 T. PUBLIC WORKS [N- DEPARTMENT WETVAULT Martin Pastucha$/13/202 .l`kD.ASQ94B0... DATE REQUIRED DIMENSIONS 8- FOR ROCK LINING "A""" + B12' FOR RIP RAP SEE TABLE 4.2.2.A. HBH (4- MIN.) z %9 Y z Q 00 mLL ILL. LL O 0- 0- 0- O �fA � -L 2' 30' MIN. MIN. z I z m m O O LU LU 0 0 PLAN NTS PLACE ROCK V ABOVE CROWN BOTH SIDES OF CHANNEL FOR "A" < 8' - ONE SIDE OF CHANNEL FOR "A" > 8' - I-1' MIN. DISCHARGE PIPE j J J- FILTER FABRIC LINER UNDER 1' OR 2' ROCK ROCK THICKNESS SEE TABLE 4.4.1.A ter" PIPE/CULVERT DISCHARGE PROTECTION NTS Know what's below. Call before you dig. • CITY OF RENTON [;R Planning/Building/Public Works Dept. LIN 0- R-41151 L3 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q J DEVELOPMENT ENGINEERINGff"�' Brianne Bannwarth 07/01/2021 ' SKYHORSE SHORT PLAT PR 17-000438 CONSTRUCTION DETAILS O C/� DATE: 1111212020 O FIELDBOOK: PAGE: DRAWING NO: 1460.3 �/ J SHEET: 15 OF: 19