Loading...
HomeMy WebLinkAboutzS-411501Setd- N T.L. 324320-0130 R-4 A6 1 T.L. 324320-0140 ADDRESS:16332 SE l 132ND ST - ADDRESS: 16326 SE 132ND ST I R-4 ® __ l -- T.L. 324320-0150 - ADDRESS: 16320 SE 132ND ST SSMH #1A, 48"� T.L. 32432I PER COR STD 400.1' R-4 / ADDRESS: 163/0 310 S SE W/ COVER & FRAME 0 j2ND RST4 I PER COR 401 w / SSMH #1, 48"0 KING C00NSTA: 7+53.70, 6.00 RT I PER COR STD 400.1 T.L. 132305-9027 IE= _ 453.472.8858 10"W/ COVER & FRAME ADDRESS: 13200 164TH R 45�E) _ , PER COR 401 AVE SE STA:10+05.73, 6.00' RT R-4 ` tD 4� _ RIM: 465.62 NTON_ _ \ SD - - - - - - So IE=452.33 10- (W) S.E. 132ND STREET ❑o IE=452.23 10 (S) w -vim o -- ---TJ w w w -w -.w _mow w -w a IN TX - .�.. - �+ T. - w - w w -\ 'h \ STA: 10+00.00 SE 132ND ST= w I- -j-' - ��- -. w .00 164TH AVE SE .. t' - - - w \ E E . 9+DO �. :..:.. .w .. STA 20+�0 - CO K' ................. .... f .. ...... KING C -. �....... LF -10.. 466 � I 252 . C.=900. 0.50.t �.. T.L. 145750-0027 460�- - 0 ADDRESS: 16307 SE 132ND ST d "� �' ' 'I' ' ' \ \ �- R 4 a ° a d d° d �..... �...... 462 10 i I 0. W. DED AT OO - r- ---- -- - -° ° d 1.'. i.. d 5,1 4 S.F. �4 / --_ ROW DEDICATION - -�- - I 26 LF 6"', PVC SID� / 12 S.F.- - LOT 1 SS STUB SEWER ®25.0 - - - SS/STUB STA.=8+09.68,FG=466RT .9E PER COR STD 06�1 / cl STA.=20+61.40, 27. RT RT -III I I ° \ T CT D R -G- of I 6" IE=459.89 " u 6 IE=458.520\ ...A. ST(� \ 5 7 2 S.F -- 33 L F 6 PVC SIDE �- - LOT 1 - 1 � SEWER ®20.0% 10,686 S.F. �•• PER COR STD 406.1� d l III I 1 \ SS STUB '6 STA.820+72.20, 32,00' LT s I T.L. �..; ...o A FG=466.0E ADC ° i .'.+ 6" IE=45&63 l 16 ----- `�' I 27 LF 6" PVC SIDE LOT 8 I \ a I\ ' 'I' ' SEWER 025.0% 9, 450 S. F. \ PER COR STD 406.1 T.L. 145750-0021 / II ADDRESS: 16327 SE / 132ND ST I �..... -- / I w .... o . ... I T.L. 145750-0023 ... °' co _-- / LOT 2 40 LF' 6" PVC SIDE I a 27 LF 6" PVC SIDE LOT 7 10,658 S.F. LOT 5 � SEWER 0 25.0% I TRACT* - SEWER ®20.0% (o A PER COR STD 406.1 ` 9, 450 S.F. / TREE TRACT 9, 62 7 S.F. PER COR STD 406.1 ' ' ' w I / 7,350 S. F LOT 2 ss STUB d\ LOT 5 SS STUB • • • LOT 7 SS STUB � I STA.=22+13.20, 155.88' RT STA.=22+05.77, 34.63' RT - i STA.=22+02.26, �42.00' LT l / FG=469.0E 13 LF 6" PVC SIDE - + FG=466.2E y SEWER 0 6.5% FG=466.0E - / 6" IE=461.70 I oo 6 IE=459.01 . c`~v 6" IE=457.78 / PER COR STD 406.1 0 / / l 42 LF 6" PVC SIDE / SSCO #4 SEWER 0 6.5% I d I IN TX _ J STA 2 + 7 H AVE SE= . • I 2 33.1 164 d - - - .... ° STA: 30+00.00 TRA T A ACCESS 11.0 LF.6" PVC SIDE #3 .. 31+88 -.. --_-- _----... R-4 - - - - - - SSCO , . - \ �SSC� 2 .. ... }+0.. - _ - - l # - ................. ... _-.. °. p p T.L. 132305 9053 LOT 3 SS STUB SSCO . #1 ° STA.=22+37.24,1155.40 RT ' d 4 . w 27 LF 6" PVC SIDE If SEWER 0 20.0% 1 LOT 6 T. JI I /6" IE-461.55 PLIB IC CCESS (fTjLjTj/ c!I. PER COR STD 406.1 9, 450 S.F. I A d I_ SSCO (TW) 13 LF 6" PVC SIDE 2,780 S.F. LOT 6 SS STUB 460 PER COR STD 403.1 I SEWER 0 6.5% 42 LF 6" PVC SIDE STA.=22+71.43, 32.00' ,LT / 11 LOT 3 PER COR STD 406.1 SEWER 0 6.5% JFG=463.5E o �= SSMH 2, 48"0 6" IE=455.98 / �6 i 10 131 S.F. # l PER COR STD 400.1 .. W/ COVER & FRAME LOT 4 a - - - PER COR 401G -- - - S STA+40+00 00,10.00 9, 384 S. F. � 'a I RIM:460.69 0 L... o . IE=450.24 10" (N), d � - " SWk6k N TRAC C / IE-450.14 10 / '� S>� ATER / �6ti`'..'. 8,835 S.F. l T.L. �750-0025 - 1 64 �464 10 SE 134TH ST LOT 4 SS STUB ¢6046 NTON R STA.=23+06.30, 37.98 RT 29 � 10 PVC 0 0.50% RE FG=461.5E R.,O.W. _ / \ �f� 6" IE=454.66DE48-0 �54�S.F. W PER CO 'STD 400.1 I / � / COUNTY/ � W/ CO R & FRAME I KING \ � ' 43 LF 6" PVC 510E - J � SEWER ®10.0% � STA: 40 29.PER COR 013, 0.00' \ / RIM: 459.54 T.L. 132305-9058 ADDRESS: 13235 166TH AVE SE IE=450. 0 10" (NE) 142 LF 10" PVC ®2 B9% IE=449.�0 10" (S) 1 \Iy KING COUNTY NT K I L CONTINUATION - SEE SHEET 16 Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 • Phone: (509) 674-7433 IAIL SURVEYED: SDM DESIGNED: 01 3 REVISIONS PER CITY COMMENTS DATED 612312021 CID0710112021 NEM w� 2 REVISIONS PER CITY COMMENTS DATED 410712021 CID0410812021 DRAWN. TLK a T �0, ssIONAL� 1 REVISIONS PER CITY COMMENTS DATED 112512020 PMD 1111212020 CHECKED: 0710112021 NO. REVISION BY DATE APPR EDM APPROVED: CJA SCALE: 1 "=30' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM SEWER CLEANOUT TABLE SSCO #1 RIM=464.84 IE=453.55 SSCO #2 RIM=468.34 IE=460.70 SSCO #3 RIM=464.90 IE=453.57 SSCO #4 RIM=468.55 IE=460.85 Know what's below. Call before you dig. • CITY OF RENTON Planning/Building/Public Works Dept. OF) 0 5 10 20 30 SCALE 1 " = 30' cx:) 00 O N1 SEE SHEET 12 FOR SEWER STANDARD NOTES NOTES: • SEWER MANHOLES TO BE INSTALLED PER COR STD 400.1 SEE DETAIL SHEET 14 S411501 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q DEVELOPMENT ENGINEERING WASTEWATER UTILITY Brianne Bannwarth 07/01/2021 ' Ann Fowler 07/02/2021 I. SKYHORSE SHORT PLAT PR 17-000438 SEWER PLAN O C� DATE: 1111212020 O FELDBOOK: PAGE: DRAWING NO: 1460.3 / ^ SHEET: Q OF. 19 3 0 w T w 3 LJ z Z J L� U Q J ON (Wn `�' ) O 1/� Ln D=Slgn Envelope ID: OFECF5S6.602A-4E4A-B436-A317AA638878 SURFACE WATER STANDARD PLAN NOTES: DocNSign Envelope ID: BEECF5B6-602AAE4A-B436-A317AA638878 SURFACE WATER STANDARD PLAN NOTES: D❑cDSign Envelope ID: 7CDD888C-CB43-439E-9366-C6DBBOFBBBB7 N e 5 O N 3 vi E 0 I W CL a 0 z w z z W Y W m N 0 LLJ z z THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SMALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES, 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS. A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON. HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND PEDERAL PERMITS PRIOR TO CONSTRUCTION. 3- ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITIDN OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM}, RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTKW PREPARED BY WSDOTAND THEAMERMAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS 9144L BE AT NOADDITIONALCOST TO THE CITY- 4. APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NDT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER, SEWER, GAS, ELi=CTRICAL. ETC.)- GLANS FoR STRUCTURES SUCH AS BRIDGES, VAULTS, AHD RETAINING WALLS REOUIRE=A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER BRA114AGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO TF,= APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILT REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY, S. ACOPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. S. THE LOCATIONS OF ALL EKISTING UTI ITIES SHOWN HEREON HAVE BEEN ESTADLISHE ❑ DY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL R T M 1 P[ P THE EFORE BE GON9IDERED APPROXIMATE ONLY AND NO NECESSARILY COMPLETE. S THE SOLE RESPONSIBILITY OF THE APPLICANT CANT AND THE A PLIOANT'S CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS-9UIL7 DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICY "VS, T. VERTICAL DATUM SHALL HE NAVO 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK, DATUM, AMC) ELEVATIONS SHALL BE NOTED ON THE PLANS- U. ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2-03.3(1410-COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. 114 PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BAC1SFiLL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92%OF MAXIMUM DRY DENSITY. 9- OPEN GUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY TkE CITY AND NOTED ON THESE APPROVED PLANS, ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 10. ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. F I SMALL B T O AND EN OP K} tl I N Titl WITH. V CONSTRUCTION ACTIV ES E 11. ALL FLOW CONTROL AC LNIED AL 1; INS ALLF ERAT N PRIOR TO OR N GONJU C N V71 . AN CON& UO DN T7T' UNL S OTHERWISE APPROVED BY THE CITY. 12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPEDIF{CATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OK THE TRENCH BOTTOM OR Tkr YCP OF YHE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THATTHE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE. UNYIELDING RASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00. 220.10, AND 220.20. 13. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, ORB INSIDE AND OUTSIDE, 14, ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL RE FITTEDWITH DUCTILE IRON, DOLT -LOCKING LIDS PER THE CITY STANDARD PLAN 204,10.204.0, 204.30, AND 24490. STRUCTURES SHALL HAVE: RECTANGULAR OR ROUND, SOLID LJDS WHEN NOT COLLECTNG RUNOFF. ANO OUTSIDE OF THE ROADWAY. • ROUND, SOLI❑ LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROATIWAY, BUT OUTSIDE OF THE CURBAGUTTER LINL • ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE P09LIC RhGNT•OF-WAY OR N AN EASEMENT TO THE CITY. AMVATE STRUCTURE LIDS OUTSIDE PUBLIC REGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 16. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE W THTABLE 4 A EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWOM. 16. LIDS OF MANHOLESICATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHCLE7CATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS GTHHTWISE SHOWN. 4 17- ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT -OF -WRY 9HALL BE OF BUFFHCLENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. UNLESS OTHERWISE NOTED, DRAWING IS NOT TOSCALE #NTS} STD. PLAN - 267.00 PUBLICwORKS SURFACE WATER STANDARD PLAN 1yaA 0: PR DEPARTMENT NOTES (1 OF 2) GAG 9/28/2018 1 'ftA, W".xe,rmnn.,w GATE Encompass, ENGINEERING & SURVEYING 4�0� Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 • Phone: (509) 674-7433 :45 THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATEb IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPUCABLETO THE PROJECT, i'IOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EO1T THE REMAINING NOTES, IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES, 10. ROCK FOR EROSION PROTECTION OF RCAUSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE II) FOOT AND SHALL MEET THE FOLLOWING SPECIFICATIONS: + 4-51NCHROCKF40-70%PASSINI4; • 2 -4 INCH ROCK f 30 -40% PASSING: AND . LESSTHAN2INCHROCK!10-20%PASSING. 19. FODTINO DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROWO BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS. 20. THE END OF EACH STORM DRAIN -9TUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT-L(YCKING LID MARKED 'STORM' SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRANAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.OD. 21- ALL STORM SYSTEM E747ENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSE IN WASHINGTON STATE, AND GUT SHFFTS SHALL BE PROVIDED TOTW CITY PRIOR TO CONSTRUGTION- 22. ALL NEWLYAINSTALLED AND NEWLY -REHABILITATED (PUBLIC ANO PRLATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 268A0. CCTV INSPECTIONS AND REPORTS SHALL Sr SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS ANDFOR PAVEMENT. 23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7.04.3I1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCEAT THE SAME TIME THE MAIN STORM IS TESTED. 24- FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE. TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 20d,00, 25, ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AKDIOR LIABILITY CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OFTHE STORM SYSTEM PROVIDED DURING CONSTRUCTION. 26. ADECUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE ECUIPMEW. FLAGGERS. AND ANY OTHERACTIONS NEE❑EO TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPTNORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDDT STANDARD SPECIFICATIONS 1.10 TEMPORARY TRAFFIC CONTROL SHALL APPLY. 27. PROJECTS LOCATED WITHIN THE CITY'S AQUIVER PROTECTION AREA IAPA} SHALL COMPLY WITH SPECIAL REOUIRPMd NT NO OF THE RENTON SWDM AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-(1501. 24. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASINWANHOLE LIDS, CLEANOUTTS, INLETS. ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES BIKE LANES SEWALKS AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACEDN I A SIDEWALK OR CROSSWALK SHALL BEOWEDWITH A NON -SLIP OR NON-811<143 LI❑ PI=R ADA REQUIREMENTS, 29. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4,2A A2 OF THE RENTQN SWOM- 31, CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOU13H TO ABSORB WATER AT A MINIMUM RATE OF 20INCHES PER HOUR 1MMEDUITELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY fOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 6 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE, IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIOERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER LOCO SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE, THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDU❑TF0- FOR LARGE AREAS (E-G.. PARKING AREAS), TESTINQ OBSERVATION MAY BE ACCOMPLISHED WHILE WALKWG BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER ATA RATE SIMILAR TO THE BUCKET TEST- PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. UN LE55 OTHERWISE NOTED, DRAW I-W 15 NOT TO SCALE (NTS} STD. PLAN - 267.10 V* PUBLIC WORKS SURFACE WATER STANDARD PLAN PAR a- R PEPARTIMENT NOTES {2 OF 2) GAZ 9/28/2018 1 Nkmav Baer-§'N4.ranr I, DATE :45 WASTEWATER LMLITY STANDPJW NOTES 1. ALL WORK AND MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY OF RENTON PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOTIAPWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988- HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1963I1991 UNLESS OTHERWISE APPROVED BY THE CITY. BENCHMARKS AND MONUMENTS $HALL 13E REFERENCED ON THE APPROVED PLANS. 3. A PRE -CONSTRUCTION CONFERENCE AND A 24-HOUR NOTICE SHALL 13E REQUIRED PRIOR To STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RFSPONSIBILITY TO SECURE ALL NECESSARY PERMITS, INCLUDING STREET USE PERMITS, PRIOR TO STARTING CONSTRUCTION. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY. IT SHALL HE THE: CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPIELCTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION- 4- THE HOURS OF WORK M THE STFZEET RIGHT-OF-WAY SHALL BE PER CITY 8PECIFICATI0NS DIN WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT-DF-WAY, S. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES DF CONSTRUCTION AKD FOR THE SAFETY OF VVCRKERS AND OTHERS ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL. CAL q STATE AND FEDERAL REQUIREMENTS. 6. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TID AVOID DAMAGE OR DISTURBANCE. THE CONTRACTOR SHALL OBTAIN A DIG TJCKET IN ACCORDANCE WITH RCW 19-122 A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION. THE CONTRACTOR SHALL HAVE A COPY OF THE DIG TICKET ON SITE AT ALL TIMES, 7. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 12-INCHES, MAXIMUM DEPTH 18-INCHES, THOROUGHLY COMPACTING EACH LAYER TO 95 PERCENT DF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE EQUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL (Mll9). 8. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVUy RUBBER-GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE CITY. 9. SANITARY SEWERPIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE WALL BUILDING FOUNDATION ETC. 0 f ) UNLESS APPROVED BY THE CITY. IF A SANITARY SEWER IS TO BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, I=TC-), fr SHALL BE ENCASED IN A STEEL CASING THAT EXTENDS A MINIMUM OF 5 FEET OUTSIDE OF SAID STRUCTURE. STEEL CASINGS SHALL SE DE&GNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON AND SHALL HAVE A 3I8-INCH MINIMUM WALL THICKNESS AND SHALL BE OF SUFFICIENT SIZE TO ALLOW [INSTALLATION OF THE SANITARY SEWER PIPE WHILE MAINTAINING CLEARANCES AS RECOMMENDED BY THE CASING SPACER MANUFACTURER- STAINLESS STEEL CASING SPACERS SHALL BE INSTALLED ON THE SANITARY SEWER PIPE AT DISTANCES THAT PROVIDE ADEQUATE SUPPORT TO PREVENT SAGGING. THE ENDS OF CASINGS SHALL BE SEALED WITH WRAPAROUND FLEXIBLE END SEALS. 10- OPEN -CUT RDAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAYS SHALL BE SACKFILLED WITH CRUSHED SURFACING AGGREGATE (WSDOT SPECIFICATION 9 03.9(3) ANO MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY, 11- ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATION DF THE CITY AND THE LATEST EDITION DF THE WSDOTIAPWA STANDARDS AND SPECIFICATION AS APPROVED AND MODIFIED BY THE CITY IN THE RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL TO A UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE, PIPE BEDDING SHALL BE IN ACCORDANCE WITH STANDARD PLAN 405. 12. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION DF T3HE CITY FOR THI= PREVENTION OF ON -SITE EROSION 130TH DURING C01NISTRUC71OIN AND AFT5R THE COMPLETION OF CONSTRUCTION IN ACCORDANCE WITH THE CURRENT SURFACE WATER DESIGN MANUAL- 13. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTQN WITH A RECORD DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYDR. STD. PLAN - 413 PUBuc WORKS WASTEWATER UTILITY APB `D (9 DEPARTMENT STANDARD NOTES GAZ 9/11/2019 1 •.Wrw ----,n- DATE SURVEYED: SCALE: SDM VERTICAL: NAVD 1968 DESIGNED: 1 "=30' HORIZONTAL: NAD 1983/1991 3 REVISIONS PER CITY COMMENTS DATED 612312021 CP 0710112021 NEM 2 REVISIONS PER CITY COMMENTS DATED 410712021 CP 0410812021 DRAWN. TLK ONE INCH DATUM 1 REVISIONS PER CITY COMMENTS DATED 112512020 PMD 1111212020 CHECKED: AT FULL SCALE EDM IF NOT ONE INCH NO. REVISION BY DATE APPR I APPROVED: CJA SCALE ACCORDINGLY :12 PN Know what's below. Call before you dig. CITY OF RENTON Planning/Building/Public Works Dept. S-411503 R-411510 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING t % Brianne Bannwarth 07/01/2021 ' SKYHORSE SHORT PLAT PR 17-000438 CONSTRUCTION NOTES DATE: 1111212020 PAGE DRAWING NO: 14603 SHEET: 12 OF. 7 61 7 1 MANHOLE FRAME AND SEE STD. PLAN, 401 ADJUSTMENT RINGS AND MORTAR JOINT° SEE NOTE 5 CONE ('ECCENTRIC) RUBBER GASKETEn JOINTS IN ACCORDANCE VVITHI ASTM C-443 STEPS - POLYPROPYLENE SHALL BE INCLUDED CONCRL'TE kISER RY PIPE INC-, OR APPROVED EJUAL- LADDER-`10L1•PROP ILENE SHALL 6E ATTACHED 10 MANHOLE MAX. PIPE SIZE - 'E' CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF .A. .8- V .D. .E. 48" MH 48 6" MIN. 5"MIN 24" MIN, 21" I.D. 54 MH ` 4 8" MIN, 5 5" MIN. 24" MIN. 24" I,D- n.Q" MN i?u" 8"tlhJ. 6" MIN. 4.2" MIN, 30" I,D, (yr7� i STEPS TO BE POLYPROPYLENE SAFETY STEPS. 2. STEPS ARE TO BE IN PLACE BEFORE MANHCII.E SECTIONS ARE INSTALLED. 3. CASTING SHALL BE PER STD PLAN 401- 4. MANHOLE SECTIONS TO BE 17F REINFORCED PRECAST CONCRETE. 5. ADJUSTMENT OF THE CASTING TD GRADE SHALL BE PER STD PLAN 105. THE USE Of SHiM5 IS PROHIBITEC+ 6. .SANITARY SEWER MANHOLES 5HALL HAVE Al L INTERIOR 51JRFACE3. INCLUDING i,HANNEUNG, (li COATED (SEALFtT) WITH A HIGH SOLIDS JFETHANE COATING. WA55ER MC-SHIELpCDA7 100 OR `L APPROVED EQLIAL; COLOR OF COATING SHALL. BE WHI'rF 0 7 RUBBEN GA5KETECI JOINTS SHALL BE IN CONFORMANCE )PITH ASTM C-443 B. CHANNEL HEIGHT SHALL 9E A MINIMUM OF S/4 OF THE IN5:DF DIAMETER OF THE LARGEST PIPE, -OR. 9, CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK .ADAPT KOR-N-SEAL BOOTS OR (n APPROVED EQUAL u i 10. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF E" AND A MAXIMUM OF If" ABQVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RING POUFEDI AT .;RARE IN FAVED AREAS, CVVER MUST SLOPE IN ALL DIRDYTICNS TO IAATCH PAVING. 11 MANHOLE..� �•:-=P 20' DEEP SHAL_ BC A MINIMUM OF 55" IN 01AMEYE'R � J 0 STD. PLAN - 400"1 PUBLIC WORKS STANDARD SANITARY MANHOLE PRD 9/1112019 I PUBLIC WORKS DEPARTMENT GAZ "''�I �� DEPARTMENT DATE v / \J ) \�IOr V w w 117 OR 6" HEIGHT TWO A3 BAR HOOPS FOR 17 HEIGHT RECTANGULAR ADJUSTMENT SECTION #3 BAR EACH CORNEF #3 BAR EACH SIDE #3 BAR EACH ..... PRECAST BASE SECTION #3 BAR EACH CORNER 18' MIN iW BAR HOOP PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR 12 PLAIN CONCRETE ALL METAL PIPE Ir CPSSP* 12" (STD. SPEC. O-O&M) SOLID WALL PVC Is, (STD. SPEC 9415.12(1)) PROFILE WALL PVC 15° (STD. SPEC. 9-05.12(2)) NOTES 1. As acceptable a9ematives to the rsbar shown in the PRECAST BASE SECTION, fibers (placed according to the Standard Specificabons), or Wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum required Mbar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. 2. The knockout diameter shall not be greater than 20". Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 3. The maximum depth from the finished grade to the lowest pipe invert shall be 5'. 4. The frame and grate must be installed with the flange down. 5. The Precast Base Section may have a rounded floor, and the walls may be sloped at a rate of 1:24 or steeper. 6. The opening shall be measured at the top of the precast base section. 7. All pickup holes shall be grouted full after the basin has been placed. 8. All grade rings and casfings shall be set in mortar in acmrdance wfth Standard Specification 9-04.3. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION Y * PUBLIC WORKS CATCH BASIN TYPE 1 STD. PLAN - 200.00 Z DEPARTMENT tp MARCH 2O08 Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 • Phone: (509) 674-7433 BOLTHOLE _ EQUALLY :F,4-k 1 APAPT ON RENT SEWER COVER & FRAME PLAN VIEW 25' DIA j Er;35mlc] 3/4' E.I4�+, , r•,r•i] E1+41•li�] COVER SECTION VIEW 1 E573mP1] 25 J /4' D!A �114• [6z„•I;, DIA E27r9r•I] r•IEC,PR.ENE GASKET L 5/8, _+ B' DIA CL OPEN I:I6Mm] C5�4rImI E7 5!1E DP% EG94mml 34 11�' DIA_ COVER BOTTOM VIEW BOLTING DETAIL 1/4 r6mm' �1 I ve• i iriril , II GASKET GROOVE DETAIL RECESSED Not to Scale LIFT POCKET FRAME oO 3/4" LETTERING "SEWER" 1 -0, DIAMETER SEWER (2) BOLT SOC. (ALLEN HEAD) - IJ n 5/8" - 11 X 1.5 STAINLESS oIIL��� STEEL REF. PART #00981 T 77 8" CLASS "B" SAND OR 10- 1/2" 5/8„ ASPHALT EXPANDABLE 12-1 2 1/4 LI 2-1/4„ BOLT DETAIL 45' (1 /8) BEND 4v V } SEND FOAM PIPE MATERIAL AS SPECIFIED BY THE ENGINEER NOTES; 1. 8„ AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC. NOTES: No. 3695 (PRODUCT NO. 00369803) OR APPROVED EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. FRAME SECTION VIEW I. ALL- COVERS SHALL HE LOCKING LID FER -AST 2. IN UNIMPROVED AREAS, POUR A S„ THICK. 2'-D" SQUARE JORDAN IRON WORKS INC. NO 3117C1 OR ECILIAL CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER. 2 USE FRAME AND COVER FOR STORM (SPEL'IF- "DRAIN" ON COVER), SANITARY {SPECIFY SEWER"}. rR WATEF `PECIFY "WAT--' STD. PLAN - 401 PPR&D UR PUBLIC WORKS MANHOLE FRAME AND COVER GAZ 9/11/2019 1 DEPARTMENT nA rr CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) - MORTAR, (TYP.). SEE NOTE 5 4'MIN 28" MAX 16, MAX. FLAT SLAB TOP 48', 54'. CO. 72", 84'. 96". 120- OR 144' SEE NOTE 6, TYP 15' MAX FOR MAINTENANCE - STEPS OR LADDER �• L - `- 12' (TYP 1 I24"o , t'MIN. 'O'RING �. 2.5' MAX. REINFORCING STEEL. (TVP. ) IN • MIN 12" MAX 1T + GRAVEL BACKFILL FOR PIPE ZONE 12' BEDDING PER WSDOT STD. SPECIFICATION SECTION 9.03. 120) 6' 8' SEPARATE BASE INTEGRAL BASE PRECAST PRECAST WITH RISER NOTES: 1 NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. . THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2' MINIMUM TO 2.F MAXIMUM PROVIDE A 1.6• MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04 3 5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE 7 MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS S. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH 9 ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION PUBLIC WORKS DEPARTMENT (D CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48' 4' 6" 36" 8` 54" 4.5" 8" 42" 8" sw 5' 8` 48" e" 7r 6' a" 60" 12, 1.e' IF 72' 1r 96" 8' 12" 84" 12' 120" 1(r tr 1. 12' 144' 12" 1r 108' 1r PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL CPSSP' SOLID WALL PVC T PROFILE WALL PVC I 49" 24" 30" 24' 30, 30' 1. 1. 36' Xr 36' 36" 60" 39" 42' 39 42' 42" 72 42" 54" 42' 48' 48. 84' 54, s0' 94' 48' 48" 96" 50" 7r e0• 48' 48" 120" 1. 84- 6O' 48' 48" 144' 78" 98' 6T CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC, 9-D5.20) 'STD. SPEC, 9-05.12(1) ISM. SPEC. 946AW) CATCH BASIN TYPE 2 UNLESS OTHERWISE NCMD, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 201.00 °GAZ 9/28/2018 I "w, •"4m,,,.,,,", DATE :4s 8" OR 6" CLEANOUT FOR SANITARY SEWER MAIN ISOMETRIC W (SEE NOTE 7) LIMITS OF PIPE ZONE 1 011 �. BEDDING MATERIAL. FOR .• - f SANITARY SEWER PIPE % O.D. OF PIPE (SEE NOTE 5) / FOUNDATION LEVEL /X BEDDING FOR SANITARY SEWER PIPE NQTES I. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3- COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE- HAND TAMP ONLY- 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS. 5, PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)' OF THE STANDARD SPECIFECATIONS OR PEA GRAVEL. 6- PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. 7- TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. I u. r-Lx tit - •FVJ.L � GAZ 9/11/2019 1 PUBLIC WORKSDEPARTMENT DATE I �OLT-DOWN SLOT, I 1r1' EE DETAIL AND IOTE 1 y4• j� 1 1I/4' I 61a' rl BOLT•DOWN SLOT DETAIL SEE NOTE 1 LETTERING 20' I 5. 24' 5' 7 OR 8 EQUAL SPACES 5' IT DIRECTION OF FLOW I 3' 1518- MAX -J SECTION A SECTION B NOTES: 1, BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 6fB'-11 NC x 2' ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS 3, FOR FRAME DETAILS, SEE STANDARD PLAN 204 00 UNLESS ORIERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 204.20 ,•,�. PUBLIC WORKS RECTANGULAR VANED GRATE R GAZ 9/28/2018 I ate DEPARTMENT DATE 01 3 REVISIONS PER CITY COMMENTS DATED 612312021 2 REVISIONS PER CITY COMMENTS DATED 410712021 38375 GISTEg 1 REVISIONS PER CITY COMMENTS DATED 112512020 SIONAL n-7 /n1 N0. REVISION SURVEYED: SDM DESIGNED: NEM CP 0710112021 CP 0410812021 DRAWN: TLK PMD 1111212020 CHECKED: EDM BY DATE AP P R APPROVED: CJA :4! �A PIPE BEDDING FOR SANITARY SEWERS /I oI 77-FLOW _N � 51 OUTFACE TO STRF�41 DUMP NO POLLUTANTS TOP 49 /\ ICESSED LETTERING vi ISOMETRIC STD. PLAN - 405 REM: GAZ 9/11/2019 1 u.,.,,..... RATE I I 1rr BOLT -DOWN SLOT. SEE DETAIL AND y4. = TE , I 1 114' I I 518' I BOLT -GOWN SLOT DETAIL SEE NOTE 1 1' 5' 5"-- 20' I s" 1 5" SECTION B NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES. AND COVERS. UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 51W.11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2- REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3. USE ONLY IN SAGS ON VERTICAL CURVES. 4 FOR FRAME DETAILS, SEE STANDARD PLAN 2D4.OD. UNLESS OTNE RWISE NOTED, DRAWING IS NOT TO SCALE IN r51 STD. PLAN - 204.30 PUBLIC WORKS RECTANGULAR BI-DIRECTIONAL °R D .� �" DEPARTMENT VANED GRATE GAZ 9/28/2018 - DATE SCALE: 111=30' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM M 4 Know what's below. Call before you dig. 0 CITY OF RENTON Planning/Building/Public Works Dept. ; i, LX' SEWER MAIN i i i l PROPERTY LINE !� SPOOL i i mi I I (LENGTH AS NEEDEO] I 1 3'-D' MIN.-{ 6" SEWER STUB I I FUTURE 4" SIDE SEWER / nE----------3 r / 2"14 4" STUD MARKING POST PAINTED I I 16" CAP WHITE WITH THE WORD -SEWER" STENCILED V5EWER MAIN TEE x fi" TEE i i i j to 3" HIGit BLACK LETTERS AND jib W RE SIDEWALK i ' x WRAPPED AROUND THE STUD AND I I I I i a ExTENDED TO THE TOP OF THE STUD. COUPLING (ll'P.] L__--_-_--J : a� 6"k8"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER (EAST JORDAN IRON WORKS PRODUCT NO. 00367502 OR I r APPROVED EQUAL, SPECIFY "SEWER" ON UD), • c�5 CLEANOUT TO 6E CENTERED IN A 2'x2' CONCRETE PAD, I Lti CONCRETE PAD TO BE 19" IN DEPTH. -- ------ ----- BEND AS 1 g" EXISTING SANITARY REQUIRED �SEWM MAIN �2-0% MIN. SLOPE '13 ` FUTURE 4" SIDE SEWER 6" SEWER STUB�6"x6"xS" WYE FUTURE 6% 4" REDUCER SEWER MAIN 512E X 6" TEE ACCEPTARLE PROCEOLJRES FOR SIDE SEWER CONNEC?ILWS TO EXISTING SEWER MAIN A. VITRIFIED CLAY MAIN -- CUT IN A NEW PVC "TEE" USING "STRONG -BACK- Fi.EXIELE COUPLINGS (FERNCO OR APPROVED EQUAL). B. CONCRETE MAIN - CUT IN A NEW PVC "TEE' USING "STRONG -BACK" FLEX11LE COUPLINGS (FERNCO OR APPROVED EQUAL). C. PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE �01R APPROVED EQUAL). D. DUCTILE IRON MAIN - CORE -DRILLED WITH A RDMAC SADDLE (OR APPROVED EQUAL) E. LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP. ETC.): CUT IN A NEW PVC "TEE, USING STRONG -BACK" FLEXIBLE COUPUNGS (FERNCO OR APPROVED EQUAL). F. HDPE - CORE -DRILLED NTH A ROMAC SADDLE. "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER. G, MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED. i dJ� 3000 WsEwrR JE•'w' G CONBLO'L`S -:HORIZONTAL $" MISEWER MAIN MAN CONCRETE BLOCKING ANGLE QF TEE AT MAIN BETWEEN 25' AND 45' TYPICAL SIDE SEWER NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. SIDE SEWER STUB STD. PLAN-406.1 PUBLIC WORKS PPR n: � ❑EPARTMENT INSTALLATION GAZ 9/11/2019 (SEWER MAIN TO PROPERTY LINE) w µl DATE LETTERING BOLT HOLES - 3 PLACES EQUALLY SPACED 120' APART ON 23 1/16' OIA. B.0 V DIA. PICKHOLE PLAN YIESS •,- _. •.•IING 25 DU. 1. -L_1_ j y4" z 112' [_8 3/4" (TYP.) (31 SILT SOC. (ALLEN HEAD I WS"-11 x 1.5 SS RUBBER WASHER EON BOLTING DETAIL 261fr DIA 25 1/4' DIA. 174' DIA. NEOPRENE GASKET 1/4' 1 U18" 16' 8 1/e" R118' 7 23 3fW DIA CL OPEN GASKET GROOVE DETAIL 27 W16' DIA. 34 1f8' DIA FRAME SECTION VIEW NOTES: 1 ALL COVERS SHALL BE LOCKING LID PER Ei No. 3717C1 OR APPROVED EQUAL UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NT51 Bs STD. PLAN - 204.SO PUBLIC WORKS STORM ROUND FRAME AND COVER P►Z 9/28/2018 1 VDEPARTMENT OATE cr 0- NOTE: CITY ONLYOBERENTON USED ONOGO THOSEALL R - 411512 LIDS WITHIN CITY OF RENTON RIGHT-OF-WAY S- 411504 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q DEVELOPMENT ENGINEERING A01%k FAnn WATER UTILITY "� � Brianne Bannwarth 07/01/2021 ler 07/02/2021 O Z DATE: L� SKYHORSE SHORT PLAT 1111212020 cry PR 17- 000438 FIELDBOOK: PAGE: O DRAWING NO: CONSTRUCTION DETAILS 1460 3 �' SHEEP: GF 14 :19 W QO 3 z X1 � 0 1 -GRA�EL- LLJ I 1 � < I w 1 I / SSMH #2 48-0 PER COR STD 400.1 1 1 \ W/ COVER & FRAME - CONTINUATION -SEE SHEET 17 -- � " T.L. 132305-9023 I 134D8 1647H SVE SE 22 LF 6" PVC SIDE / I SEWER ® 2.0% MIN / CB 117A, TYPE 2, 48" MH Ln z6 � z� w LO o `LnLn X z w z 0 I II 11 II z EL X I• 1 I l I r > z z N w � o U " -� I X Nd � LLI �Ln w�� � \Lo o11 w �- w I PER COR 401 I W/ SOLID LOCKING LID > w 4�5 ' - w �!; 308 LF 10" C-900 SS ® 0.49% STA:23+11.30, 5.34' LT I I z^ STA:44+03.74, 8.00' LT z z I I r w T.L. 132305-9058 13404 164TH SVE SE > z RI 60 69 °� I I L RIM 457 66 CB 16 TYPE 2 48" MH z O �' NORTH 0 5 10 20 30 SCALE 1 " = 30' IEM450.24 10" (N) x I I a z N IE=44731 18" (NW) W/ SOLID LOCKING LID U 1 �: w h / Jo NOTES: \ I IE-45014 10" (SW) T.L. 132305-9058 w N o IE=44731 18" (S) STA•46+5095 839' LT �� U 1. DEWATERING IS NOT ANTICIPATED. IF •' I d �Iowa o � o - NEU 475 470 465 460 455 450 445 440 435 C� W , DDRESS: 13235 166TH AVE SE 1 1 8" PVC SEWER ® 1.00% c� �° U DEWATERING IS REQUIRED, CONTRACTOR WILL FOR FUTURE EXPANSION 0 Q INSTALL SIDE SEWER RIM. 464.78 }" z IE=446.06 18" S o L WORK WITH CITY AND COUNTY INSPECTORS TO x 39 LF 12 PVC SO ® 5.82X _ 1 z OUTSIDE r 5°/ INSTALL SILT FENCE AND O $ DETERMINE BEST METHOD TO PROCEED. AT NO 464-_1 -- a II /� / CB #20, TYPE 2, 48" MH STRAW WATTLES AS NEEDED IE=446.06 18" (N) I g POINT SHOULD SILT LADEN WATER BE \ X z / (DOWNSTREAM) OF / m 6" PVC SIDE SEWER TO PROTECT ADJACENT 132305-9 86 1 l I N > z W/ SOLID LOCKING LID 46 3�' SSMH #4 48"0 w - m THE MANHOLE /5° I - DISCHARGED TO EITHER THE STORM OR SEWER i 2 _ " Ln z ®2.0% MIN PROPERTY MAINTAIN ACCESS \ Y PER COR STD 400.1 SSMH 5 48 0 u x SYSTEM. STA: 40+05.89, 12.31' LT - - - I # (rYP[cALJ w TO EXISTING RESIDENCES/ I RIM: 460.00 r L _ \ I W/ COVER & FRAME PER COR STD 400.1 x - � n 11 zo / \ 1 SSMH #3 48 0 / I PER COR 401 W/ COVER &FRAME PVC / z' -� X - x x _ IE=452.74 12" (E) PER COR STD 400.1 \ 1 STA:41+70.91, 0.00' PER COR 401 1 = 2. 6" SIDE SEWERS SHALL BE EXTENDED TO THE ®0 S° - cc x v� x z x x - x - x / J I EDGE OF ROW FOR ALL LOTS AND CAPPED FOR IE=452.74 12" (W) W COVER &FRAME / RIM: 455.67 - -� Q o J " / Y d' - z FUTURE CONNECTION. � / � STA:43+46.55 0.01 RT m T z _ -z DER -cam �, ° �m J / ---- ��-- ---- - 1/ IE=446.50 10" (N) RIM: z - -5 o J 00 247 LF 18" PVC SD 6 0.51% 31 LF 12" PVC o _ - \ Q - -6�-0� - - ('-$ 56.'� " r 3. ALL SIDE SEWER STUBS SHALL MEET CITY OF STA:40+29.13, 0.00 I IE=446.50 8" (E) IE=445.50 10" (N) Y q56 =-- = SD ® 1. Off z RIM.459.54 0 - ""O - " ( ) - _- / c 45+00 � � � _ _ - W ■ y -- +00= - RENTON STANDARD PLAN 406.1. SIDE SEWER �- � IE-446.50 8 W IE-445.40 10 SE - 29 LF 10" PVC - IE=_450.00 10" -P45R PO / 1 I IE=446.40 10 (S) - - - - - - - - / / 0 - - ,\ - \� / _ STUBS SHALL HAVE A MINIMUM OF 2.5 FEET SS b 0.50% - O - 1� - - - - - /1 J - �� I �F5 LOWER THAN THE LOWEST HOUSE \ Y IE-449.90 10 S - COVER AT THE PROPERTY LINE AND BE - 142 LF 10 PVC SS ®2 39% FLOOR L NATION A 2'X2' CONCR TE PAD WILL M / x x - .. \ - x = 456 42+00 176 LF "PVC SSA ■ 0.519 43+00 0 oM , 3+00 - ■ z 1 +0 / 2+00 299 LF 12" PVC SD ® 1.57-9 164TH AVENUE S.E. / 460 6 - " - -462 - _ - - CB /18_ TAPE 2, 48 MH - W/ SOLID LOCKING- LID - 33 LF 18" PVC i - CB #19, TYPE�1; 48 MH i - - - - - -464- 8" PVC SEWER ® 3.46% PER - STA:43+-1717, 7.17' RT SD ® 0.43% - \X _ 1.0LID-OCKING LID - - - PLAT OF MAPLE HIGHLANDS_ - - - -- - - _ -- RIM:456.37 I _ _ STA:40+25.21, Y.3fi �T i - - - - -466- - - __ N o IE=44775 12" (N) IE=447.75 18" (S) w RIM. 460.00 i IE=452,43112" (E) � / - - - - - 468- - - - � � O o CB #178, TYPE 2, 48" MH _ _ � - , - tE=4;52.43 12�S) __ - _ _ W/ SOLID LOCKING LID z w Ln STA: 43+46.55, 8.24' RT / RIM: 45Z 12 / 466- - IE=447.61 18" (N) � IE=447.61 18" (SE) i +0 6 EE E i31tf IF 10" C-900 SS_� a.501K - - - - - N 3 �� - Q BE REQUIRED FOR THE CLEANOUT WHERE NOT LOCATED IN A PAVED SURFACE. -- - -� - /�-� i L -M�_ M M M 3 M �- M ,M M \ M M - - - ` 4. ALL TREES SCHEDULED FOR REMOVAL IN M I `�' - - - _ - / - �E - KCROW WITH AN OD OF MORE THAN 4 INCHES - - - - z SHALL BE MARKED IN THE FILED AND SSMH #7 60"0 PER COR STD 400.1 I� APPROVED BEFORE REMOVALS. i - N a W/ COVER & FRAME z SSMH #6 48 0 - I " m o PER COR 401 PER COR STD 400.1 0 6 PVC SIDE SEWER STA: 46+89.88, 0.00' I () W/ COVER & FRAME ®2.0% MIN Q RIM: 465.41 PER COR 401 o I m IE=466.98 i l � IE=443.60 10" (N) STA:43+79.47, 0.00' o z 0£ Sl IE=443.50 10" (E) RIM:45783 o I U J z " IE=445.25 10 (NW) � CD 0 58 LF 18 PVC IE=445.25 6" (E) 't r v ' _ SD ® 0.50% IE=445.15 10" (S) J I Y z I cY) z J ... Y 6" PVC SIDE SEWER LU ® 2.0% MIN U l IE=456.81 CB 16 TYPE 2 4 " MH W/ SOLID LOCKING LID STA:4 +50.95, 8.39 LT RIM. 4 78 1 =446.06 1 • (S) CB 2 TYPE 2 " MH 1 =446.06 1 " (N) W/ SOD LOCKING LID STA:4 +05.89, 12.31 LT= STA: 3+23.53, 1 .38' LT RIM: 460. 00 IE=45 .74 12" (E) r.. r IE=45 I .74 12" (W MH CB 18 TYPE 2 48" MH // (V z .- �I CB 18 TYPE 2 40" ID LOCKING z O 6 W/ SO UD W SOLID LOCKING LID � I STA: 1 1 RT-- S :43+17.17, Z17 RT CB 17B TYPE 2 48" MH CB 17A TYPE 2 8" MH o ¢ Lu l STA: 22 +23+23.53, 1 1 .83' RT RI :456.37 W/ SOLID LOCKINGLID ID W/ SOLID LOCKING z w cn w RIM: 46 IE=45243 .00 " 12(E) IE=447.7 12" (N) STA: 43+46.55, 8. 4 RT STA: 44 03.74, 8.0 LT IE=4477 18" (S) RIM. 4 7.12 RIM. 457 66 / - 8 - 4 4 7- - E- f► IE=44 .61 18" (SE) IE=447. 1 18" (S) w LU. _ 31 LF 12 P O SD 0 1.00% z z LLI 33 LF 18 PVC O �. SO 0.43% 58 18" P ® 0.50 L-i 99 L " N W14 Lssw 10" p 7X z z 3 48"0 SS ® 2.399• COR STD � PER 0.1 247 IF 1 " PVC SD 0.51% z z z W/ OVER & FRAME OU O PER 4 17 LF 10" PVCSS ® 0.5 % . ......... 0 STA: 0+29.13, .00' SS H' 48"0 - IE-4 0.00. 10 STD400.1 - SS ® 0.50 PER CO �- IE=4 (NE) 9.90, 10" 5) W/ COVE P & FRAME R COR 401 S H 48 SSMH 48"0 W �: PER C STD 400.1 PER COR STD 400.1 STA:41+ 0.91, 0.00' W/ CO R & FRAM W/ COVER & FRAME - ILU SSMH 2 48"0 RIM: 455.67 ER CDR 4 1 PER COR 401 SSMH F, 60"0 Cn. z IE=446. 0, 10" (N) STA:43+46.55, 0.01' R STA:43+7 .47, 0.00' PER COR S7D 400.1 PER COR STD 400.1 0 W COVER & FRAME IE=44 .50, 8" E RIM.456.8 RIM: 457.8 W COVE &FRAME (� PER COR 401 IE= .50, 8" (W) _ IE=445.25, 10" (NW) P COR 401 STA: 23+1 .30, 5.34 L T= . IE=446.40, 10" (S) IE=445 40, 10" ( IE=445.25, 6" (E) STA: 46+ 9.88, 0.00' STA: 40+ 0.00, 0.00 IE=445.15, 10 (S) RIM:465.41 RIM: 460.E 3. 0, 10" (N) ........1E=450.24 10 N 33 LF 10" PVC SS 0 0.46% IE =443. 50, 10" (E) IE=450.14 LO 10" (SW) 0) _..,� a �, et con O N •-- �"� O co v- N O n n N. r'') �t O. O 00 0) I� �- 00 N �. O o� O ._ O r� I� N.O �F N to rn .N I� N (O 00 0� _. N �"� �, � �. LC) �,Do O LC) � �. O LC) Imo. (O �n 6. Cp (0 Ln ((� "� 0i I:\ Ili �n OJ M. LO � Lo (n (6 D Ln �n .(6 00 � Ln (6 0 LO (n Ld I\ LO �n WS r W) ui wi. W) � �. LC) (6 Ob �(i (6 I� In Ln (6 �.t6 LO �n C0 to �n (0 I< In Ln (6 LIB In C9 - cD �n .I�. Ci Ln � �n Oj Ci �n Ci O :0 Lrj Ci �0 0j Ci Cp c0 CO �0 O Ca .Oj C1 Ci Ci �F V V eF d- �l d �1 d V d a �t V d st �I �h - I- "t d 'F d �! V d �h i LL LL d LL d V d LL LL d LL d V LL d V CD w C9 C� w. C� C� LL Lw L� L� �, C) C .�.. w C� L� LLJ C� �, C9 4. w . C� Li . C5 w w. C� LL w C� LL w C� LL w. C� � . w C9 6 . � w CL (3 Li C� w � w. � . w C3 .w 6 w . � w <_ L. � _L-J � w 6 w. (3 w . w C� w . C� . w � w. C3 w C3 C� 39+80 40+00 41+00 Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. - Cle Elum, WA 98922 - Phone: (509) 674-7433 42+00 43+00 xrL OFFSITE UTILITIES-1 HORIZ. 1 "=30' VERT. 1 "=5' 01 3 REVISIONS PER CITY COMMENTS DATED 612312021 �� 2 REVISIONS PER CITY COMMENTS DATED 410712021 38375 �EGISTEg 1 REVISIONS PER CITY COMMENTS DATED 112512020 SIONAL 07/01/2021 N0. REVISION 44+00 SURVEYED: SDM DESIGNED: NEM CP 0710112021 CP 0410812021 DRAWN: TLK PM D 1111212020 CHECKED: EDM BY DATE AP P R APPROVED: CJA 45+00 SCALE: VERTICAL: NAND 1988 1 "=30' HORIZONTAL: NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 46+00 Know what's below. Call before you dig. CITY OR RENTON • Planning/Building/Public Works Dept. 475 470 465 460 455 450 445 440 435 Q J i w w R 4 115 14 47+00 47+20 S- 4 1 1 5 0 5 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q J attL DEVELOPMENT ENGINEERING • � I WASTEWATER UTILITY Brianne Bannwarth 07/01/2021 Ann Fowler 07/02/2021 SKYHORSE SHORT PLAT PR 17- 000438 OFFSITE UTILITY IMPROVEMENTS O Z DATE: Lu 1111212020 V) FIELDBOOK: PAGE: O DRAWING NO: 1460.3 SHEEP: OF 16 :19 Ct- Ln d- ■ 0 V) 3 WORK SHOWN ON THIS SHEET WITHIN SE 135TH & 166TH AVE SE IS IN KING COUNTY RIGHT OF WAY. A PERMIT WILL BE REQUIRED FROM KING COUNTY PRIOR TO THE START OF WORK RESTORATION WITHIN KING COUNTY R-O-W SHALL COMPLY WITH KING COUNTY ROAD STANDARDS CONTINUATION -SEE SHEET 16 �I III�•I T.L. 145750-0033 CB#16, TYPE 2, 48" MANHOLE I 1 I 247 LF 18" PVC SD W/SOLID LOCKING LID I I� �' .� 0 0.51% STA:46+50.95, &39' LT f RIM=464.78 / I,' .� / 310 LF 10" C-900 SS 0 0.50% EX. CB COORINDINATE WITH OWNERS RIM=452.74 SSMH #8 48"0 TO MAINTAIN ACCESS TO IE=446.06, 18" P,S) 472 NV=451 .14 12"CONC-NNW EXISTING DRIVEWAYS Y ( ) PER COR STD 400.1 INSTALL SILT FENCE AND STRAW G COUN NV=451.09 (12"GONG-S) W/ COVER & FRAME WATTLES AS NEEDED TO PROTECT KIN PER COR 401 ADJACENTOPROPTING RESIDENCES STA:49+97.43, 0.00' oN �jj 1 I 4' CYCLONE FENCE 6 VC SIDE SEWER 02.0%MIN I - RIM.454.25 " RENT w y j 3" PVC (N) 3 PVC (N) IE-442.00 10 (W) 6 PVC SIDE SEWER ®2.0% MIN 324 LF 10 PVC SS ®2.93% �w� r 1 ..' I x IE=454.32 6" VC SIDE SEWER ®2.0% MIN IE-453.52 IE=441.90 10 (E) " 6" PVC SIDE SEWER 6" PVC SIDE SEWER POINT SHOULD SILT LADEN WATER BE M J W w 12" CONC (W) 6 PVC SIDE SEWER ®2.0% MIN / / DISCHARGED TO EITHER THE STORM OR SEWER - f 7 I / /� 12" CONC (W) T.L. 132305-9096 12" CON IE=454.36 0 2.0% MIN 0 2.0% MIN /l 11 SYSTEM. SE 135T \ q \ = (E) T.L. 132305-9057 T.L. 132305 9061 H ST. �� 1 IE=453.44 2" CONC (W) T.L. 1 305-9075 ` CYCLONE ENCE SSMH _ \ _71 _ _ _ / _ _ _ _� T.L. 132305-9066 2" CONC (E) --4�4 12 CONC (W) 2" ONC (NE) / PER COR STD 400.1 2. 6" SIDE SEWERS SHALL BE EXTENDED TO THE ��aa5 nn IE=4 .24 49" EDGE OF ROW FOR ALL LOTS AND CAPPED FOR �� - - - E=451 .13 12" CONC (E) I I W/ COVER &FRAME \ - �� -454 - - / - I 30' RO)W� I \ IE=447.10 _ 12 ADS PER COR 401 FUTURE CONNECTION. e - - sD ' -® - -456 - - - - - - _ i � 3" PVC (NE) IE=44 4 1 2" IE=�437 77 STA 53+21 19 0 00' GUARDRAIL \ -._ - - - -so - _ 1 IE=443.88 -I d- - --- ---- F454- - 1---------- - - _ _ - - E I.. W. w w _ OVV -SD-- W w1 T.L. 947596-0160 SSMH #7 60" PER COR STD 400. W/ COVER & FRAM PER COR 40 STA:46+89.88, 0.00 RIM: 465.4 IE=443.60 10" (N IE=443.50 10" (E 345 LF 18" PVC S 00.507. z O y x 0 5 10 20 30 -20 ' / SCALE 1 " = 30' / J 28"/ i /°" NOTES: �1 1. DEWATERING IS NOT ANTICIPATED. IF 2 l / 6" DEWATERING IS REQUIRED, CONTRACTOR WILL WORK WITH CITY AND COUNTY INSPECTORS TO l l 1 DETERMINE BEST METHOD TO PROCEED. AT NO I E- 44)v. 9 0 (E) / I RIM: 439.88 ' 3. ALL SIDE SEWER STUBS SHALL MEET CITY OF IE=432.40 10" (W) RENTON STANDARD STUBS SHALL HAVE ALAN 406.1. SIDE MINIMUM OF 2.5 FEET co IE=432.30 f0" (S) OF COVER AT THE PROPERTY LINE AND BE LJE?/ ESE=E w _ W w 30' o 0 0 \ 3-5 FEET LOWER THAN THE LOWEST HOUSE _ FLOOR ELEVATION. A 2'X2' CONCRETE PAD WILL E - ter. -...... \y - .-5i- -1T1 I--� BE REQUIRED FOR THE CLEANOUT WHERE NOT E x - x x - w - w� 30' ROW ' �� / SE 135 H S . D-!S - - - E E-_ _.-E � '4�4- � �- w � - / �� ... �. �- 1 \ 12" C NC E' - - s so - - - - - _ o d _ �� _...: _ \ \ T.L. 722970-01C LOCATED IN A PAVED SURFACE. ' ADS E - -x / - ( ) - w E I. I CIE=459.83 IE=454.71 - APPROX. ® - E- D E S° E E = w_ - W - w w j � I 1 4. ALL TREES SCHEDULED FOR REMOVAL IN 1 l C EX. CB LOCATION �E - s° - w� 4. KCROW WITH AN OD OF MORE THAN 4 INCHES RIM=453.92 WATER MAIN 12" CONC (E) �� E so - - w -W "�_\w - I'^ SHALL BE MARKED IN THE FILED AND z INV=450.52 (12"CONC-N 308 LF 10" C-900 SS 0 0.49% IE=453.08 APPROVED BEFORE REMOVALS. �. C� INV=450.52 (12"ADS-W) 1 - CONC (E) 3" ADS(S) 12" CONC (E) I. � O p - 4' CYCLONE FENCE INV=450.52 (14"ADS-` ` T.L. 772970-0005 L. 722970-0015 E 450.74 IE 448.38 IE=445.96 F 1/2" CONC - IE=442.59 I. 3N < O 6" PVC SIDE SEWER 0 2.0% MIN = CONC (W) 12" CONC (W) 12" CONC E D R� rY E=451.36 ( ) 12" CONC E / � O OUN IE=449.05 IE=445.07 ( )�,- I j � _KING 6" PVC SIDE SEWER 0 2.0% MIN T.L. 722970-0020 IE=444.47 3" PC/C (SW) \ I hij �I M T.L. 772970-0025 IE=43 . � 0 6 PVC SIDE SEWER 0 2.07MIN T.L. 722970-0030 8 33 J m 12" CONC (SE) 24" CMP S 0 6" PVC SIDE SEWER 0 2.07MIN E=436.72 E=434.01 z 302 LF 10" PVC SS 0 0.40%IIyl �. Q K OC 4' CHAIN LINK --i z FENCE\V/ 30' I I i I T CONTINUATION -SEE SHEET 19 CONTINUATION -SEE SHEET 18 465 460 455 450 445 440 435 430 46+80 47+00 48+00 49+00 50+00 51+00 52+00 OFFSITE UTILITIES-2 HORIZ. 1 "=30' VERT. 1 "=5' VHILIp Al Encompass r�� of WAs� ���j jr/r��.� �q o jJl SURVEYED: SCALE: - VERTICAL: NAVD 1988 SDM „ , HORIZONTAL: NAD 1983/1991 1 -30 ENGINEERING & SURVEYING ♦ 01 3 REVISIONS PER CITY COMMENTS DATED 6/23/2021 CID 07/01/2021 DESIGNED: NEM Western Washington Division 2 �° REVISIONS PER CITY COMMENTS DATED 4/07/2021 CID04/08/2021 DRAWN: TLK 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 " Phone: (425) 392-0250 Eastern Washington Division �Ec sTgR ;� `%ss 1PMD REVISIONS PER CITY COMMENTS DATED 112512020 11/12/2020 ONE INCH DATU M CHECKED: AT FULL SCALE 407 Swiftwater Blvd. • Cle Elum, WA 98922 • Phone: (509) 674-7433 ZONAL EDM IF NOT ONE INCH 07/01/2021 N 0. REVISION BY DATE AP P R APPROVED: CJA SCALE ACCORDINGLY Fl \ \ \ Q0 CID Uj \ ~ X uj W LtJ Cn Co � Q 08 LF 10" C-900 SS 9 0.49% _SSMH 7 60"0 PER COR STD 4 90.1 SSMH i 0 z w/ COVER & FliAME PER COR SID 400.1 z 0 PER COR 401 W/ COVER & FRAME 32 STA. 46+89.88, 00' PER COR 401 I-F 10" P SS V RIM: 465.41 STA: 49+97.43, 0.00' 0 2 9 IE= 43.60, 10" N) RIM:454.25 IE= 43.50, 10" E IE=442.00, 10" (W) IE=441.90, 10" (E) )0 co C co N CN 0-1 00 M -M I. rn Lr) Ln Ln Ln o O N N Ln to d-. NF Ln LE) co c0 Ln LO o). M Ln to 't � _ _ C�) o) cD O O Ln W)Q0 c0 O O L0 c0 � 0) nn Do 00 n Q) 00 co CO c0 O) 0) n n W) 00 00 O N N Ln U-)CT)«W Ln to i") O O � 0) I� � 00 rj vi r 0� of oc: 00 co c6 Sri Wi U� wi �t �I d rf �f �h Ln to Lcj l(j ri c[i Tri to V d N' t j N N N N O O CSo� 0i 00 N r< K co 4j a L6 �h N N O C; 0� of 9 cn CO co LO c0 Ln LOLn U') Ln U*) Ln LO U-) Ln Ln Ln Ln Ln LC) LO Ln Ln Ln to Ln to Ln U Ln LE) Lr) to Ln Ln LC) W) Ln U) E� W)Ln =li LO d- d- �f' Ch' �I' �F. e1' d- el. V- �f' d- �1. d' el' �f' V. n n d- �1- �}- �1- d- el' d- �I- r}- mil- d- e} d' �' r}- ef' O O O O � CO C� O O O C0 O O O O O C.D O �. O. O (.D O O O. O O O O O. O O _ W LL O C.O O O O C0 O O O O LLJ LL. LU O_ _ L' V' LI L� � LLI � W L� W LL LrJ � W - � LL L� LL W LL Lli � LLJ. l� W � W � LLI. ly LLI LL W lL L� LL W LL Lam. LL_ W L� W �. LL W LL W � LLL �. W - Lam. L� � W L� Lu L�, ly � 53+20 R 411515 S-411506 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q J DEVELOPMENT ENGINEERING WASTEWATER UTILITY Brianne Bannwarth 07/01/2021 Ann Fowler 07/02/2021 I- 0 Z DATE: SKYHORSE SHORT PLAT 1111212020 cry PR 17- 000438 FIELDBOOK: PAGE: O DRAWING NO: OFFSITE UTILITY IMPROVEMENTS 1460 3 �' SHEEP: GF 17 :19 53+00 Know what's below. Call before you dig. �. + CITY OF RENTON Planning/Building/Public Works Dept. U Q J t65 00 t60 0 t55 t50 45 t40 05 t30 ALL WORK SHOWN ON THIS SHEET IS IN KING COUNTY RIGHT OF WAY. A PERMIT WILL BE REQUIRED FROM KING COUNTY PRIOR TO THE START OF WORK RESTORATION WITHIN KING COUNTY R-O-W SHALL COMPLY WITH KING COUNTY ROAD STANDARDS NORTH In 0 00 3 LO I III I I I I 6" PVC SIDE SEWER 6" PVC SIDE SEWER 0 2.0%' MIN I 0 2.090 MIN I �� 6" PVC SIDE SEWER COORINDINATE WITH OWNERS n z 0 2.0% MIN I TO MAINTAIN ACCESS TO SSMH 119 48"0 w EXISTING DRIVEWAYS PER COR STD 400.1 U w DO / \ W/ COVER & FRAME N � w z - PER COR 401 d II N w n LL o APPROX. LOCATION / U. STA:53+21.19, 0.00, w o LF) I WATER MAIN / T.L. 722970-0100 � � II o II RIM: 439.88 I N w o IE=432.40 10" (W N Ld w T.L. 7229 -90 IE=432.30 10"INS) T.L. 7 2970-0 95 I - - 450- \ J - -436 - as (IS _ -440� n - z- -436 0 8� - -436 - �- - - QN- f43 o O / i M f��t n,-- - M O I M M M M M M M ' M M Jvto- o j \ 166TH AVE SS+o ---- - ✓�4+ ---- - --- ---- - - - - - - - / --- - \ o X \ X _ � 49�v � � M -436 Z. =1�1\0 r j - - -434 - - _ 302 LF 10" PVC SS 0 0.40q w \ - - - SSMH #10 48"0 l / PER COR STD 400.1 o INSTALL SILT FENCE W/ COVER & FRAME N `' \ I 6" PVC SIDE SEWER \ J ( AND STRAW WATTLES >- / N 0 2.0% MIN \ / PER COR 401 w ll \ AS NEEDED TO ` STA: 56+23.03, 0.00 11rr442\ 3 �� ° SAWCUT & RESTORE N-) PROTECT ADJACENT \ \ RIM: 443.30 C Z z PROPERTY. MAINTAIN IE=431.10 10" (N) z N N z PAVEMENT IN KIND (TIP) o II \ o / o w FOLLOW KING COUNTY 0 w ACCESS TO EXISTING � IE=431.00 10" (S) 0, L Lw STANDARDS RESIDENCES w _ w \� \I / o N T.L. 722970-0030 I I rN 324 LF 10" PVC SS 0 2.93% :� r� ,I J CONTINUATION -SEE SHEET 17 455 450 445 :Al-m LX-S8I GY.blm LP•Td D QS I I NIc4-��� 1170 00Z mcr ozLn Au- r I \ � 03d `1P33W3Sb U / !- I d3M3S-- 1JVIINVS 91 / x > > / ET, cn T.L. 132305-9038LLJw / DSO I I LIBERTY SCHOOL T.L/ 1323059038 = o CD 0 CO m w cc z z z U-) / \cc 77 _ \ J I 254 LF 10 C-900 SS 0 1.807 n o � > \ \ \ LLJ Q DO Ln� >> z z - Lu� / \ \LU -K - 4+55.98 X. CONC. D 24" IE=4 3f 6 ILLI 302 LF 10" PVC o a40AG SSMH 48"0 z LJ PER COR STD 400.1 z COVER R & FRAME 254 LF 1 " C-900 P COR 401 SSMH " 0 0 ®1.80 V STA:53+ 1.19, 0.00' PER CO STDD 400.1 RIM:439. 8 W/ COVER & FRAM 1E=432. , 10" (W) PER COR 401 1E=432.3 , 10" (S) STA:56 23.03, 0. U IE=431.1 , 10" (N) EX: MH IE=431. , 10" (S) 6, 0' RT STA:58+71. RI = 445.03 EX. IE=426.03, 12" (ESE) E . IE=425.9 , 10" (E) E . IE=425.8 , loll (W) IE=426.4 , 10 N I� d Ln d �0 Lf) 00 c0 10) 00 n (b n LC) 0) 00 rn 1:7) CIO Cr) 00 Lr,) ^ Ln N Co N O 00 O n Qo to Lr) to to �0 to r, W) N LC) N co u) l-0 to O to O N N 0) Lc� O) LO d- o e1- LC) o U7 r n n ^ In rn O) N ^ N (0 O to � O O V- O d O O. 0� e1 Oi. 0� P) 0i f+) 06 Cd 06 n �) � r-� r. n r r< I\ r< r. 1\ r< h ri r. h) r< 06 Op .0� 0; O. O lYj Mj ¢. d e}. 'd Op �. �. Lri M lCj W rn 06 d d d r< 05 e} 0i ej Ln ri O. d 00 � Op. 10 d (p �} el' mot- e1- d- ) V- V- �1- � d- a- � �1- d- eF d- M e{ d- V- a'- n �1- el- V �F �1- �- e1- d- eF e} d- d �Y d- M <r- el- d- �1- d- In er- d- el- a'- �1- rl- eF sl- d- t e} d- d- d- �l V- d- V- W 4 I C CL C O 3 w w w w w w L� iC w w wC w w w w w w w LW LL w 4 52+80 53+00 Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 - Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. - Cle Elum, WA 98922 - Phone: (509) 674-7433 54+00 141L H 55+00 56+00 OFFSITE UTILITIES-3 HORIZ. 1 "=30' VERT. 1 "=5' 01 3 REVISIONS PER CITY COMMENTS DATED 612312021 38375 � 2 REVISIONS PER CITY COMMENTS DATED 410712021 REGISTER �;� 1 REVISIONS PER CITY COMMENTS DATED 112512020 SIGNAL 0710112021 N0. REVISION 57+00 SURVEYED: SDM DESIGNED: NEM CP 0710112021 CP 0410812021 DRAWN. TLK PMD 1111212020 CHECKED: EDM BY DATE AP P R APPROVED: CJA SCALE: 58+00 VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 1 "=30' ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 455 450 445 :ids] :A1-7 3�1�] .Pzi] 58+80 EX. SSMH STA: 58+76.46, 0.03' LT RIM: 445.02 IE=426.42 10" (N) EX. IE=426.03, 12" (ESE) EX. IE=425.98 10" (E) EX. IE=425.88 10" (W) Know what's below. Call before you dig. % CITY OR 140 RENTON Planning/Building/Public Works Dept. 0 5 10 20 30 SCALE 1 " = 30' NOTES: 1. DEWATERING IS NOT ANTICIPATED. IF DEWATERING IS REQUIRED, CONTRACTOR WILL WORK WITH CITY AND COUNTY INSPECTORS TO DETERMINE BEST METHOD TO PROCEED. AT NO POINT SHOULD SILT LADEN WATER BE DISCHARGED TO EITHER THE STORM OR SEWER SYSTEM. 2. 6" SIDE SEWERS SHALL BE EXTENDED TO THE EDGE OF ROW FOR ALL LOTS AND CAPPED FOR FUTURE CONNECTION. J. ALL SIDE SEWER STUBS SHALL MEET CITY OF RENTON STANDARD PLAN 406.1. SIDE SEWER STUBS SHALL HAVE A MINIMUM OF 2.5 FEET OF COVER AT THE PROPERTY LINE AND BE 3-5 FEET LOWER THAN THE LOWEST HOUSE FLOOR ELEVATION. A 2'X2' CONCRETE PAD WILL BE REQUIRED FOR THE CLEANOUT WHERE NOT LOCATED IN A PAVED SURFACE. 4. ALL TREES SCHEDULED FOR REMOVAL IN KCROW WITH AN OD OF MORE THAN 4 INCHES SHALL BE MARKED IN THE FILED AND APPROVED BEFORE REMOVALS. U i S-411507 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q J DEVELOPMENT ENGINEERING WASTEWATER UTILITY Brianne Bannwarth 07/01/2021 Ann Fowler 07/02/2021 I- 0 Z DATE: LLJ SKYHORSE SHORT PLAT 1111212020 cry PR 17- 000438 FIELDBOOK: PAGE: O DRAWING NO: OFFSITE UTILITY IMPROVEMENTS 1460.3 SHEEP: OF 1 O :19 T L. 722970-0006 N Ln 3 RIM: 41�4.78 fE=44C06 18" (S) IE=44906 18" (N) J H LX. 7ZZ LI- 1Z NU 9 7.36% CONTINUATION -SEE THIS SHEET Z I o h ~ Cn IMH LID ® Zoa Ir C o 0 .00'Lj � 42 g (W) ^° (E) U �wQ (N) L o Lei cn co) _ W/ SOLID LOCK NG LID TA: 10+13.9 , 0.00 475 RIM. 472.42 (REC NECT EX. STORM LINE) IE=468 50 2" (W) IE=444.33 8" (E) IE=444.33 8" (N) 470 CB 6 TYPE 2. 480 MH - W/ OLID LOCKING LID STAL66 .39 LT - RIM 1E= (S) � 1€= ) i 465 l� I• 1. �.T. �.. �. �. .. .. .. .. .. .. .. .. .. .. .. .. .. . LU STRUCTURES OVER DEEP -00 Lu REQUIRE STRUCTURALDESIGN 460 455 z U 450 3 LF18"PCSD®0.0% 445 440 `jI IIIIIIIIIIIIIII� .. . N K9 � 6 C6 6 C� C� 6 C� 6 6 W W W W W _W W W 7+00 Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Elum, WA 98922 • Phone: (509) 674-7433 8+00 9+00 OFFSITE STORM OUTFALL HORIZ. 1 "=30' VERT. 1 "=5' xrL 10+00 01 3 REVISIONS PER CITY COMMENTS DATED 612312021 38375 �� 2 REVISIONS PER CITY COMMENTS DATED 410712021 REGISTER �;� 1 REVISIONS PER CITY COMMENTS DATED 112512020 SIONAL 07/01/2021 N0. REVISION 475 470 Uj 465 LU LU 460 Q z z O 455 I,, O 450 445 440 CONTINUATION -SEE THIS SHEET -7 '77 475 LU LU 470 LLI 465 LIJ O 460 z z O Q) 455 O 1450 1440 WORK SHOWN IN THIS AREA WITHIN 164TH AVE SE IS IN KING COUNTY RIGHT OF WAY. A PERMIT WILL BE REQUIRED FROM KING COUNTY PRIOR TO THE START OF WORK RESTORATION WITHIN KING COUNTY R- 0- W SHALL COMPLY WITH KING COUNTY ROAD STANDARDS C8 #15, TYPE 2, 60" MH W/ SOLID LOCKING LID STA:10+13.93, 0.00' RIM: 472.42 IE=468.50 12" (W) IE=444.33 18" (E) IE=444.33 18" (N) - w w - w - W 100 LF 18" VC ® 0.50% EX. 122 LF 12" SD 7.36% E. 1 /4 CORNER SEC. 14-23-05 CALCULATED POSITION C 15, TYPE 2 60" MH W SOLID LO KING LID S A:10+13.93 0.00 R : 472.42 11+00 CB 1114, TYPE 2, 48" MH W/ SOLID LOCKING LID STA:11+14.05, 0.00' RIM: 456.56 IE=443.83 18" (W) IE=443.83 18 (E) o�o � - w- w " 4.60% 12+00 12+?6 SD OUTFALL, RIP RAP OUTFALL PROTECTION 8.5'xl2'x2' STA: 12+18:18, 0.00' IE=439.11 12" (W) I 468.50 12 (W) (REC NECT EX. TORM LINE) 1 444.33 18 (E) I 444.33 18 (N) \\ _ C 4 TYPE 2 48" MH I SOLID LOCKING LID W R 456.56 .00 \\ 1 _ 443.83 18 (W) 1 443.83 18 (E) STRUC RES OVER 5' DEEP ` \ REQUIRE STRUCTUR L DESIGN ® 0.50% \ 18 PVC Sp ® _ 60$LO \ CEI WLQ SURVEYED: SDM DESIGNED: NEM CP 0710112021 CP 0410812021 DRAWN. TLK PMD 1111212020 CHECKED: EDM BY DATE AP P R APPROVED: CJA SCALE: 11+00 OFFSITE STORM OUTFALL HORIZ. 1 "=30' VERT. 1 "=5' VERTICAL: NAVD 1988 1 "=30' HORIZONTAL: NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 475 470 465 460 455 450 445 440 12+00 12+25 Know what's below. Call before you dig. 0 �. + CITY OF RENTON Planning/Building/Public Works Dept. NORTH 00 0 5 10 20 30 SCALE 1 " = 30' 61 • i R-411516 S- 411508 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q DEVELOPMENT ENGINEERING 1 � Brianne Bannwarth 07/01/2021 ' O Z DATE: SKYHORSE SHORT PLAT 1111212020 cry PR 17- 000438 FIELDBOOK: PAGE: O DRAWING NO: OFFSITE UTILITY IMPROVEMENTS 1460.3 SHEEP: OF 19 :19 `- J