Loading...
HomeMy WebLinkAboutT-409103N 0 0-) 0 Nt w w U) w z_ J U Q Call 2 Working Days Before You Dig 811 tilities Underground Location Centel (ID,MT,ND,OR,WA) ?7'AffE'Ar TPA FF/C EXPERTS 11410 NE 124th St., #590, Kirkland, WA 98034 Phone:425.522.4118 Fax:425.522.4311 JTURE LUMINAIRE BY OTHERS FUTURE LUMINAIRE BY OTHERS / FUTURE LUMINAIR BY OTHERS /STER`�'�G�� 2 REVISED PER COR REDLINES N A L 1 REVISED PER COR REDLINES NO. I REVISION CONSTRUCTION NOTES 0 INSTALL NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE FIXTURE AND POLE PER STANDARD PLAN 176.1, CONCRETE FOUNDATION, AND ASSOCIATED JUNCTION BOX PER DETAILS ON SHEET 3 AND 4, AND LUMINAIRE POLE SCHEDULE. OINSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD FOLLOWING COR STD. PLN. 120. O INSTALL CONDUIT TO EDGE OF PAI/EMENT. LUMINAIRE SCHEDULE LUM. POLE * CIRCUIT LOCATION INC. ID. N0. N0. 11 A ROAD A 23+92 12 A ROAD A 24+38 13 A ROAD A 24+80 14 A ROAD A 25+38 15 A ROAD A 26+00 16 B 164TH AVE SE 32+15 17 A 164TH AVE SE 33+15 18 B 164TH AVE SE 31 +24 19 A 164TH AVE SE 30+14 GPS COORDINATES LATITUDE ILONGITUDE 1321531.1829 178939.1968 1321577.2620 178905.2350 1321618.4748 178940.7976 1321677.1932 178906.7817 1321738.4787 178943.3704 1321788.2380 178963.8283 1321786.4334 179063.3326 1321790.7272 178872.9950 1321792.9190 178762.5080 OFFSET LED LAMP MAST ARM MOUNTING STANDARD (FEET) WATTAGE (FEET) HGT. (FT.) PLAN # 17.0' LT 44 NA 14' 116.1 17.0' R T 44 NA 14' 116.1 17.0' LT 44 N A 14' 116.1 17.0' RT 44 NA 14' 116.1 17.0' LT 44 N A 14' 116.1 17.0' LT 44 N A 14' 116.1 17.0' LT 44 N A 14' 116.1 17.0' LT 44 N A 14' 116.1 17.0' LT 44 N A 14' 116.1 * NOTE: POLE ID NOS. ARE TO BE PROVIDED BY THE CITY AND INSTALLED BY THE CONTRACTOR PER COR STD PLAN 121 AT TIME OF CONSTRUCTION. GPS COORDINATES WILL BE PROVIDED AT THE TIME OF AS BUILT PLANS LEGEND LED PEDESTRIAN LUMINAIRE AND DECORATIVE POLE ROADWAY LUMINAIRE - - - - - PVC CONDUIT (SEE WIRING SCHEDULE) ® TYPE 1 JUNCTION BOX WITH CONCRETE PAD VJG 6/14 VJG 6, LDH LDH BY I DATE I APPR SERVICE CABINET WIRE NOTE CONSTRUCTION NOTE SURVEYED: DESIGNED: VJG DRAWN: VJG CHECKED: LDH APPROVED: LDH SCALE: WIRING SCHEDULE CONDUIT CONDUIT CONDUCTORS NOTES RUN SIZE 0 1 2.0" PVC (SCHEDULE 40) 2-#8, 1-#8 GREEN 7 2.0" PVC (SCHEDULE 80) PULLSTRING VERTICAL: NAVD 1988 AS NOTED HORIZONTAL: NAD 1983/1991 ONE INCH DATU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 30 0 30 60 scale feet & 91 �6 CITY OF t RENTON Planning/Building/Public Works Dept. AS -BUILT T-409103 IN COMPLIANCE WITH CITY OF RENTON STANDARDS MAPLE HIGHLANDS PLAT ILLUMINATION PLAN 162ND AVE SE/SE 134TH ST RENTON, WASHINGTON 98056 6/14/21 FIELDBOOK: PAGE: DRAWING NO: IL2 SHEET: OF: 2 4 0 0 'i Q0 0 0 0 W Q