HomeMy WebLinkAboutR-409126w Q z J L RENTON O DRAIN %� 1/2" LETTERING BOLT HOLES -3PLACES EQUALLY SPACED 120" APART ON 23 1/16" DIA. B.C. (1) V DIA_ PICKHOLE of AM 111cw 1 1/4" LETTERING Cn 0 z25" DIA 3l4" J 2 21/z„ 8 3/4" (TYP.) COVER SECTION VIEW I..L 26 1/2" DIA. 25 1/4" DIA. 1/4" DIA. NEOPRENE GASKET 1 SIS" 23 3/8' DIA. CL OPEN 27 5/16" DIA. 34 1/8" DIA. FRAME SECTION VIEW COVER BOTTOM VIEW (3) BLT SOC. (ALLEN HEAD) 5/8"-11 x 1.5 SS RUBBER WASHER EON BOLTING DETAIL 1/4" 1 1/16" 1/8" R1/8' 51 GASKET GROOVE DETAIL NOTES: 1. ALL COVERS SHALL BE LOCKING LID PER EJ No. 3717C1 OR APPROVED EQUAL. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) • DS STD. PLAN - 204.50 [1,R) PUBLIC WORKS PP Y 1,RDEPARTMENT STORM ROUND FRAME AND COVER 9/28/2018 1 DATE IT MAX. FOR MAINTENANCE CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) MORTAR, (TYP.), SEE NOTE 5 4" MIN. 28" MAX. 16" MAX. FLAT SLAB TOP 48", 54", 60", 72", 84", 96", 120" OR 144" EE NOTE 6, TYP. STEPS OR LADDER 'I 12" (TYP.) i 1" MIN. 24" "0" RING 2.5" MAX. (TYP.) REINFORCING STEEL, TYP. MIN. 12" 12" MAX. GRAVEL BACKFILL FOR PIPE ZONE " 12" BEDDING PER WSDOT STD. SPECIFICATION SECTION 9-03.12(3) 6" 6" SEPARATE BASE INTEGRALIAIE PRECAST PRECAST WITH RISER NOTES: 1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3. THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48" 4" 6" 36" 8" 54" 4.5" 8" 42" 8" 60" 5" 8" 48' 8" 72" 6" 8" 60" 12" 84" 8" 12" 72" 12" 96" 8" 12" 84" 12" 120" 10" 12" 96" 12' 144" 12" 12" 108" 12" PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL CPSSP SOLID WALL PVC, PROFILE WALL PVC, 48" 24" 30" 24" 30" 30" 54" 30" 36" 30" 36" 36" 60" 36" 42" 36" 42" 42" 72" 42" 54" 42" 48" 48" 84" 54" 60" 54" 48" 48" 96" 60" 72" 60" 48" 48" 120" 66" 84" 60" 48" 48" 144" 78" 96" 60" 48" 1 48" 'CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) 2 STD. SPEC. 9-05.12(1) 3 STD. SPEC. 9-05.12(2) UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 201.00 •®• PUBLIC WORKS PR CATCH BASIN TYPE 2 DEPARTMENT GAZ 9/28/2018 1 DATE I Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) �. P I ED/ �O of WA sy/ sC tic 53232 �SS/GISTQ�NAL a��� 13,21 8 REMOVABLE WATERTIGHT COUPLING -OR FLANGE - 2' MIN. CLEARANCE TO ANY PORTION OF FLOW RESTRICTOR TEE INCLUDING ELBOWS 2" MIN. ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 6" MIN, 6" MAX. PLATE WELDED TO ELBOW WITH ORIFICE AS SPECIFIED, SEE NOTE 3 ELBOW RESTRICTOR DETAIL NE 114 SECTION 14, TOWNSHIP 23 N, RANGE 5 E, W.M. MAPLE HIGHLANDS i/. \ ADDITIONAL LADDER RUNGS (IN SETS) TO \�` ALLOW ACCESS TO TANKS OR VAULTS \ WHEN CATCH IS FILLED WITH WATER 4-1�-\ ANGLEAS / NECESSARY, � SEE NOTE 7 j 2'MIN, PLAN VIEW ELEVATION PER PLANS 12" MIN. UNDER FRAME & SOLID COVER MARKED "DRAIN" PAVEMENT WITH LOCKING BOLTS PER STD. PLAN 204.50 16" MAX. VERTICAL BAR GRATE FOR SECONDARY INLET 6" MIN. DESIGN WATER ELBOW RESTRICTOR, SURFACE - SEE DETAIL AND NOTE 10 HANDHOLDS, STEPS, OR LADDER PIPE SUPPORTS, SEE NOTE 6 12" (TYP.) 1.5 x D SEE NOTE 9 (TYP.) MIN. 2' MIN. I D 1 ISOMETRIC i OUTLET PIPE, SEE INLET PIPE NOTES 1 & 5 2' o MIN. SHEAR GATE WITH CONTROL ROD FOR INVERT AND CLEANOUT/DRAIN (ROD BENT AS REQUIRED ELEVATION PER PLANS FOR VERTICAL ALIGNMENT WITH COVER) 12" SECTION OF PIPE ATTACHED BY PER STD. PLAN 237.30 GASKETED BAND TO ALLOW REMOVAL 2' 12" MIN. WELDED RESTRICTOR PLATE WITH ORIFICE DIA AS SPECIFIED, SEE NOTE 10 NOTES: SECTION A 1. USE A MIMIMUM OF A 54" DIAMETER TYPE 2 CATCH BASIN. 2. OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW. 3. METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 4. FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4". 6. PROVIDE AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM 3'4" VERTICAL SPACING). 7. LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. 8. LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER. 9. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10. IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 237.00 A1111111111[;`R] %PUBLIC WORKS FLOW CONTROL STRUCTURE - (A.PPROVED: DEPARTMENT RESTRICTOR TEE GAZ 9/28/2018 1 nr,, works Ad-1,-1., DATE y 1'. 2", 4', 6', 12', OR 24' ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION s�cF l , \OTFa #3 BAR EACH CORNER #3 BAR EACH SIDE a #3 BAR EACH WAY PRECAST BASE SECTION #3 BAR HOOP #3 BAR EACH CORNER 18"MIN. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION PUBLIC WORKS PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 12" CONCRETE ALL METAL PIPE 15" CPSSP", 12" STD. SPEC. 9-05.20 SOLID WALL PVC, STD. SPEC. 9-05.12(1) 15 PROFILE WALL PVC, STD. SPEC. 9-05.12(2) 15 ' CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H:24V OR STEEPER. 6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 200.00 APPR ED: VRI DEPARTMENTCATCH BASIN TYPE 1 GqZ9/28/2018 1 DATE 1 CITY COMMENTS 11"12"19 D.R. STRONG 2 INTAKE COMMENTS CONSUL TING ENGINEERS 3 CITY COMMENTS 07.27.21 ENGINEERS PLANNERS SURVEYORS 620 - 7Ih AVENUE KIRKLAND, WA 98033 O 425.827.3063 F 425.827.2423 N 0. REVISION CONTROL ROD (ROD BENT AS REQ D FOR VERTICAL ALIGNMENT WITH COVER) TOP OF DETENTION EL. = 454.00 12" CMP RISER PIPE PIPE SUPPORTS) (SEE NOTE 4) IE= 448.00 SHEAR GATE WITH CONTROL ROD FOR CLEANOUT/DRAIN RESTRICTOR PLATE W/ ORIFICE 0 = 1.60" O.C. (SHARP EDGED SHOP DRILLED) FROP DETAIL FROP NO TES: 7.00 FREEBOARD 4" ELBOW IE= 452.75' ORIFICE 0 =1.75" 4" ELBOW IE= 451.35' ORIFICE 0 =2.00" 6.00' DETENTION DEPTH 6.25' W.Q. DEPTH j TOP OF SEDIMENT 59_MIN. STOR.= 441.75 N IS 1. OUTLET CAPACITY: 100-YR PEAK FLOW 2. METAL PARTS: CORROSION RESISTANT. NON -GALVANIZED PARTS PREFERRED. GALVANIZED PIPE PARTS TO HAVE ASPHALT TREA TMEN T 1. 3. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 114" 4. PROVIDE AT LEAST ONE 3'X.090 GAUGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM 3' VERTICAL SPACING) 5. LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. FIL �J 00 Q J IN TERCEP TOR TRENCH CROSS SECTION N IS IN TERCEP TOR TRENCH NOTE• CLEANOUTS TO BE INSTALLED AT BEGINNING, END AND AT ALL BENDS OF INTERCEPTOR TRENCH R-409126 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Cn Q SURFACE WATER UTILITY , Z Q krevans 10/01 /2021 J DEVELOPMENT ENGINEERING njanders 10/01 /2021 YLP 02.14.20 YLP SURVEYED: DJC SCALE: NOTED VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 /1 neT' m • o C T Y 0 [;R R E N T O N • Planning/Building/Public Works Dept. MAPLE HIGH LANDS STORM DRAINAGE DETAILS 16210 SE 134TH STREET DATE: 09.05.19 J YLP 06.16.21 YLP DESIGNED:AS YLP 08.13.21 YLP FIELDBOOK: PAGE: Q DRAWN: GLB ONE INCH DRAWING N0: C26 CHECKED: AT FULL SCALE BY41 DATE APPR IF NOT ONE INCH SCALE ACCORDINGLY RENTON, WASHINGTON 98059 APPROVED SHEEP: OF- �� DRS PROJECT NO. 17020