Loading...
HomeMy WebLinkAboutR-40914100 O I N I n r) z J 2 J n Q 75 Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) 1 oil 1!1 �� UTILITY CONFLICT NOTE: NE 1/4 SECTION 14., TOWNSHIP 23 N, RANGE 5 E, W. M. MAPLE HIGHLANDS 8.5' PRIVATE STORM DRAINAGE EASEMENT 8.5' PRIVATE STORM DRAINAGE L -j --- � --------- -.------- EASEMENT r = --- --- -- ---- - - - _ 5' PRI VA TE S TORM - DRAINAGE 5' PRIVATE STORM EASEMENT DRAINAGE -►I -' EASEMENT '12 8 4 5 6 7 CD �I - - - - MIN. 5' CLEAR BETWEEN 10' JOINT UTILITY NEAREST OUTSIDE EDGE EASEMENT OF PIPES (WA TO SS) I �_� -- - -- -- - - --- - - - - - - - - - --- - - - --- -1- - - r a Imo. ROAD A - 4 e a MIN. 5 CLEAR BETWEEN, NEAREST OUTSIDE EDGE OF PIPES (SD TO SS) 5' PRIVATE STORM I DRAINAGE V \ I EASEMENT 110 I 9 I I � TRACTB TREE RETENTION 7' PRIVATE STORM i - �� DRAINAGE �� ./� •�� EASEMENTI x THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE AT 811 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED ON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT D.R. STRONG CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. UNDERGROUNDING NO TE.- POWER LINES TO BE UNDERGROUNDED FROM EXISTING POWER POLES. POWER PLANS TO BE PROVIDED BY PUGET SOUND ENERGY. ALL EXISTING AND NEW UTILITIES IN FRONTAGE AND WITHIN SITE ARE REQUIRED TO BE UNDERGROUND. ---------- IE-------- H p ---------- --------- H---------n---------- ---------- IL--------- ---------- --------- u---------u--------- T-RA CT A ----- TORM- -4R-A-INA-Gf --------- ----------It--------- H---------n ----------IE---------H---------H--------- ---------- --------- u - H ll --- --------- H-----------------r UTILITY CROSSING TABLE CROSSING NO. F.G. UTILITY LE. BOTTOM OF PIPE TOP OF PIPE CLEARANCE (FT) 1* 508.85 12" SD 505.45 505.40 8" WA 504.18 504.90 0.50 2* 504.05 12" SD 500.73 500.68 8" WA 499.46 500.18 0.50 3* 482.40 12" SD 479.13 479.08 8" WA 477.86 478.58 0.50 4 482.45 12" SD 478.99 478.94 8" SS 470.31 471.03 7.91 5* 456.89 12" SD 451.20 452.25 8 " WA 453.22 453.17 0.92 6 456.94 12" SD 451.09 451.04 8" SS 448.35 449.07 1.97 7* 455.52 12" SD 451.42 451.37 8" WA 450.15 450.87 0.50 8 455.71 10" SS 446.88 447.76 8" WA 452.04 451.99 4.23 9 455.50 12" SD 451.17 451.12 8" SS 446.76 447.48 3.64 10 437.55 10" SS 445.63 446.51 8" WA 453.06 453.01 6.50 11 456.63 12" SD 447.67 448.72 8 " WA 452.96 452.91 4.19 12 466.71 12" SD 446.03 447.08 EX. 8" WA 463.04 462.99 15.91 13 455.23 EX. 12" SO 451.31 451.26 10" SS 442.78 443.66 7.60 14 473.79 12" SD 444.40 445.45 EX. 8" WA 470.12 470.07 24.62 15 439.91 10" SS 432.24 433.12 EX. 8" WA 436.24 436.19 3.07 16 437.55 EX. 24"SO 433.94 433.89 10" SS 431.61 432.49 1.40 17 444.15 10" SS 430.76 431.64 EX. 8" WA 440.48 440.43 8.79 18 511.20 8" SS 495.17 495.89 EX. 8" WA 507.53 507.48 11.60 *MINIMUM 12" VERTICAL SEPARATION BETWEEN UTILITIES AT CROSSING OR INSTALLATION OF ETHAFOAM PAD IS REQUIRED **SEE PLAN AND PROFILE SHEETS FOR LOCATION OF OFFSITE UTILITY CROSSINGS NOT SHOWN ON THIS SHEET 1 CITY COMMENTS 11.12.19 YLP 02.14.20 YLP SURVEYED: SCALE: D,IC D.R. STRONG 2 INTAKE COMMENTS YLP 06.16.21 YLP AS NOTED CONSUL TING ENGINEERS 3 CITY COMMENTS 07.27.21 YLP 08.13.21 YLP DESIGNED DRAWN: ENGINEERS PLANNERS SURVEYORS GLB ONE INCH 620 - 7th AVENUE KIRKLAND, WA 98033 CHECKED: YLP AT FULL SCALE NOT ONE INCH O 425 827 3063 F 425 827 2423 N0. REVISION BY DATE APPR APPROVED: ALE ACCORDINGLY SCALE YLP VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 30' UTILITY, EASEMENT REC. NO. 20 10406000762 Aoffftlk C TY OF P%'R) RENTON VANIV Planning/Building/Public Works Dept. X LJ 00 Q J NORTH R-409137 GRAPHIC SCALE 40 $° S-409113 1 INCH = 40 FT. W 409101 IN COMPLIANCE WITH CITY OF RENTON STANDARDS (1) 0 SURFACE WATER UTILITY z krevans 10/01 /2021 1 DEVELOPMENT ENGINEERING v njanders 10/01 /2021 _ LU DATE: MAPLE HIGHLANDS 09.05.19 COMPOSITE UTILITY PLAN FIELDBOOK: PAGE: DRAWING 16210 SE 134T H STREET C 41 RENTON, WASHINGTON 98059 SHEET: OF: 41 41 DRS PROJECT NO. 17020