DEPARTMENT OF
COMMUNITY AND
ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:July 26, 2012
TO:Pre-Application File No. 12-055
FROM:Vanessa Dolbee, Senior Planner
SUBJECT:Renton Aerospace Training Center
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official
decision-makers (e.g., Hearing Examiner, Community & Economic Development Administrator,
Public Works Administrator, Planning Director, Development Services Director, and City
Council). Review comments may also need to be revised based on site planning and other
design changes required by City staff or made by the applicant. The applicant is encouraged to
review all applicable sections of the Renton Municipal Code. The Development Regulations are
available for purchase for $50.00 plus tax, from the Finance Division on the first floor of City Hall
or online at www.rentonwa.gov
Project Proposal: The subject property is located at 300 Rainer Avenue. The project is located at
the Renton Municipal Airport. The Airport site totals 167 acres in area and is located within the
Medium Industrial (IM). The pre-application packet indicates that the proposal is to remodel
the interior of the existing 3,200 square foot building, expand the structure to meet the needs
for the Aerospace Training Center (ATC) to 4,050 square feet, and update the site. The site
would be updated by providing a loading dock, garbage receptacle, parking lot improvements,
and porous parking. If the existing building cannot meet the needs of the ATC then a new
building may be built to replace the existing structure. Access to the site would be reconfigured
in one of two ways, either the maintain access to Rainer Avenue would be redesigned or access
would be reconfigured to be off of West Perimeter Road.
Current Use: The property currently vacant, it used to be the location of the Renton Chamber of
Commerce.
Zoning: The property is located within the Employment Area Industrial (EAI) land use
designation and the Medium Industrial (IM) zoning designation. Trade or vocational schools are
outright permitted uses within the IM zone.
Development Standards: The project would be subject to RMC 4-2-130A, “Development
Standards for Industrial Zoning Designations” effective at the time of complete application
(noted as “IM standards” herein).
Renton Aerospace Training Center, PRE12-055
Page 2 of 4
July 26, 2012
h:\ced\planning\current planning\preapps\12-055.vanessa\12-055 (im renton aerospace training
center).doc
Minimum Lot Size, Width and Depth – There are no minimum requirements for lot width or
depth within the IM zone, however, there is a minimum lot size requirement of 35,000 square
feet which is not applicable to the proposal.
Lot Coverage – There is no minimum lot coverage requirement within the IM zone.
Setbacks – Setbacks are the distance between the building and the property line or any private
access easement. The required setbacks in the IM zone are as follows: 20 feet for a front yard;
zero for the rear yard; and zero for the interior side yards. Based on the provided application
materials and comments from the City’s Property Services Davison, the existing building is
located in the right-of-way. As such, if the building is expanded is shall be brought into
compliance with the right-of-way encroachment. Not enough information was provided with the
application to verify compliance with the setbacks.
Building Height – There is no maximum building height requirement within the IM zone.
Screening – Screening must be provided for all surface-mounted and roof top utility and
mechanical equipment. The building permit application will need to include elevations and
details for the proposed methods of screening.
Refuse and Recycling Areas – Refuse and recycling areas need to meet the requirements of RMC
4-4-090, “Refuse and Recyclables Standards” (enclosed). For office, educational and
institutional developments a minimum of 2 square feet per every 1,000 square feet of building
gross floor area shall be provided for recyclable deposit areas and a minimum of 4 square feet
per 1,000 square feet of building gross floor area shall be provided for refuse deposit areas with
a total minimum area of 100 square feet.
Refuse and Recycling information as not provided with the application. This information shall
be provided at building permit application.
Landscaping – New development shall comply with the City of Renton Landscape requirements.
The subject development would be required to comply with this section if the cost of the
remodel/addition is equal to or greater than fifty percent (50%) of the assessed property
valuation.
Except for critical areas, all portions of the development area not covered by structures,
required parking, access, circulation or service areas, must be landscaped with native, drought-
resistant vegetative cover. The development standards require that all pervious areas within
the property boundaries be landscaped. The minimum on-site landscape width required along
street frontages is 10 feet, except where reduced through the site plan development review
process. When an Industrial Zoned Lot or Use is Abutting a Residential or Commercial Zone: A
fifteen-foot (15') wide partially sight-obscuring landscaped visual barrier, or ten-foot (10') wide
fully sight-obscuring landscaped visual barrier, is required along the common property line.
Commercial zoned property is located across Rainer Avenue.
Please refer to landscape regulations (RMC 4-4-070) for additional general and specific
landscape requirements (enclosed). A conceptual landscape plan and landscape analysis
meeting the requirements in RMC 4-8-120D.12, shall be submitted at the time of application
for building permit application.
Fences – If the applicant intends to install any fences as part of this project, the location must be
designated on the landscape plan. A fence detail should also be included on the plan as well.
Renton Aerospace Training Center, PRE12-055
Page 3 of 4
July 26, 2012
h:\ced\planning\current planning\preapps\12-055.vanessa\12-055 (im renton aerospace training
center).doc
Parking – The following ratios would be applicable to the site:
Use Employees & Students Ratio Required Spaces
Colleges and
universities,
arts and crafts
schools/studio
s, and trade or
vocational
schools:
Unknown A minimum and maximum
of 1 per employee plus 1
for every 3 student
rooming units, plus 0.5
space for every full-time
student not residing on
campus. In addition, if
buses for transportation
of students are kept at the
school, 1 off-street
parking space shall be
provided for each bus of a
size sufficient to park each
bus.
Min/Max: Unknown,
not enough
information
provided with the
application
Bicycle
Parking
Unknown 10% of the number of
required off-street parking
spaces.
Unknown
Based on the information provided staff was unable to determine the required number of
parking stalls for the ATC. The applicant will be required at the time of building permit
application to provide a parking analysis of the subject site and provide detailed parking
information (i.e. stall and drive aisle dimensions) and calculations of the subject site and the
overall campus use.
It should be noted that the parking regulations specify standard stall dimensions. Surface
parking stalls must be a minimum of 9 feet x 20 feet, compact dimensions of 8½ feet x 16 feet,
and parallel stall dimensions of 9 feet x 23 feet; compact surface parking spaces shall not
account for more than 30 percent of the spaces in the surface parking lots.
ADA accessible stalls must be a minimum of 8 feet in width by 20 feet in length, with an adjacent
access aisle of 8 feet in width for van accessible spaces. The appropriate amount of ADA
accessible stalls based on the total number of spaces must be provided. Surface parking lots
with 15 or more stalls shall provide a minimum of 15 square feet of landscaping per parking
space. Please refer to landscape regulations (RMC 4-4-070) for further general and specific
landscape requirements (enclosed).
The proposed loading space shall be shown on a plan and submitted for approval by the
Development Services Division.
Access and Driveways – two different accesses were proposed in the application. No plans were
not provided that indicate how the re-configuration would be designed.
Driveways shall not exceed forty percent (40%) of the street frontage. The width of any
driveway shall not exceed fifty feet (50') exclusive of the radii of the returns or taper section, the
measurement being made parallel to the centerline of the street roadway.
Critical Areas: The City of Renton’s Sensitive Areas maps indicate the presence of “protected
slopes” on the subject site. Protected slopes are defined as topographical features that slope in
Renton Aerospace Training Center, PRE12-055
Page 4 of 4
July 26, 2012
h:\ced\planning\current planning\preapps\12-055.vanessa\12-055 (im renton aerospace training
center).doc
excess of 40% and have a vertical rise of 15 feet or more. If any work is planned on a “protected
slope” a Variance from the Critical Areas regulations would be required. The variance would be
reviewed by administratively and the burden would be on the applicant to demonstrate that
there is no feasible alternative other than to disturb the “protected slopes.” In any event, a
geotechnical report addressing the slope concerns will be required as part of the environmental
review process.
The subject site is located in area of known Cultural Resources. Based on the possible presence
of archeological discoveries within the vicinity of the subject site a SEPA mitigation measures
would likely be applied to the subject project.
Environmental Review
It appears the subject project would be subject to SEPA Environmental Review because the
square footage of the proposed remodeled or new building would exceed 4,000 square feet or
an additional 20 parking stalls may be proposed. Therefore an environmental checklist is a
submittal requirement. An environmental determination will be made by the Renton
Environmental Review Committee. This determination is subject to appeal by either the project
proponent, by a citizen of the community, or another entity having standing for an appeal.
Permit Requirements
The proposal would require Environmental (SEPA) Review. All application can be reviewed in an
estimated time frame of 6-8 weeks once a complete application is accepted. The application fee
for SEPA Review (Environmental Checklist) is $1,000. There is a technology fee, of 3 %, based on
the total land use application fees for the project. Detailed information regarding the land use
application submittal is provided in the attached handouts.
In addition to the required land use permits, separate construction, building and sign permits
would be required. The review of these permits may occur concurrently with the review of
the land use permits, but cannot be issued prior to the completion of any appeal periods.
Impact Mitigation Fees: In addition to the applicable building and construction fees, the
following mitigation fees would be required prior to the issuance of building permits. Impact
fees, which would replace mitigation fees, may be adopted prior to construction. Those fees are
to be determined. The following are current fees:
A Transportation Mitigation Fee based on $75.00 per new daily trip attributed to the
development;
A Fire Mitigation Fee based on $0.52 per square foot of new commercial building
area.
FIRE & EMERGENCY SERVICES DEPARTMENT
M E M O R A N D U M
DATE:July 11, 2012
TO:Vanessa Dolbee, Senior Planner
FROM:Corey Thomas, Plans Review Inspector
SUBJECT:Renton Aerospace Training Center
1. The fire hydrant and fire flow requirements for the proposed center
are adequate as they exist.
2. An automatic fire sprinkler system will be required if the proposed
center exceeds 5,000 square feet.
3. The existing fire department apparatus access road is
adequate.
4. An automatic fire alarm system is required in all buildings that
exceed 3,000 square feet. System shall be fully addressable
and full detection is required.
5. Exiting shall meet all current building and fire code
requirements.
`
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:July 11, 2012
TO:Vanessa Dolbee, Planner
FROM:Arneta Henninger, Plan Review
SUBJECT:RENTON AEROSPACE TRAINING CENTER
RENTON AIRPORT
PRE 12-055 PARCEL 0723059007
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official city decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the City to build an Aerospace Training Center at the old
Renton Chamber of Commerce building site on the airport, located in Sect. 7 Twp. 23N, Rng 5 E. The
following comments are based on the pre-application submittal made to the City of Renton by the
applicant.
Water
This site is located in the City of Renton water service areas.
The site is not located in the Aquifer Protection Zone.
There is an existing 12” DI water main located on the Airport on West Perimeter road. See City of
Renton drawing number W 858. This main can provide 2,000 GPM.
There is an existing ¾” domestic water meter off of the main in West Perimeter Road.
There is an existing 12” DI watermain in Rainier Ave S. See City of Renton water drawing #W0199
for details. This main can provide 2500 GPM.
The site is located in the 196 water pressure zone. The static pressure is approximately 60 psi at the
building pad level.
Construction of a commercial building will trigger a separate review.
The existing fire hydrants may need to be fitted with stortz fittings to bring them up to current City
code.
Per the City of Renton Fire Marshal the building may be required to be sprinklered if the center
exceeds 5,000 square feet.
The Water System Development Charges are based on the size of the (each and all) water meter(s).
These fees are collected at the time a construction permit is issued then prior to the issuance of the
building permit.
RENTON AEROSP0ACE TRAINING CENTER – PRE 12-055
Page 2 of 2
07/12/2012 5:16 PM
Sanitary Sewer
There is an existing 8”sanitary sewer main on the Airport site, on West Perimeter Rd. See City of
Renton drawing S-1688.
The existing building is connected to sewer with a side sewer coming out of the front of the building
then to the north then down the hill (east) to the existing sewer main in West Perimeter Rd.
The site is not located in any Special Assessment Districts or any Latecomers boundary.
The Sanitary Sewer System Development Charges are based on the size of the domestic water
meter. These fees are collected at the time a construction permit is issued, if there is no
construction permit then prior to the issuance of the building permit.
Storm Drainage
There are existing storm drainage conveyance pipes and facilities in Rainier Ave N.
A storm drainage report may be required. All storm drainage shall be in compliance with the City of
Renton amendments to the 2009 King County Surface Water Drainage Manual.
Storm System Development Charges are $0.405 per square foot of new impervious surface area.
These fees are collected at the time a construction permit is issued.
Street Improvements
Additional street improvements will not be required.
Traffic Mitigation fees do not apply. A traffic study will not be required.
General Comments
All required utility, drainage, and street improvements will require separate plan submittals
prepared according to City of Renton drafting standards by a licensed Civil Engineer.
All plans shall be tied to a minimum of two of the City of Renton Horizontal and Vertical Control
Network.
Permit application must include an itemized cost estimate for these improvements. Half of the fee
must be paid upon application for building and construction permits, and the remainder when the
permits are issued. There may be additional fees for water service related expenses. See Drafting
Standards.