DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:September 13, 2012
TO:Pre-Application File No. 12-070
FROM:Vanessa Dolbee, Senior Planner
SUBJECT:Schneider Preliminary Plat
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official
decision-makers (e.g., Hearing Examiner, Community & Economic Development Administrator,
Public Works Administrator, Planning Director, Development Services Director, and City
Council). Review comments may also need to be revised based on site planning and other
design changes required by City staff or made by the applicant. The applicant is encouraged to
review all applicable sections of the Renton Municipal Code. The Development Regulations are
available for purchase for $50.00 plus tax, from the Finance Division on the first floor of City Hall
or online at www.rentonwa.gov
Project Proposal: The subject property is located near at the dead end of S 47th Street, parcel
number 3123059048. The applicant is proposing a preliminary plat for a 27-lot subdivision of a
9.31-acre site located within the R-8, R-1 and R-14 zoning designations. The proposed lots are
intended for the eventual development of detached single-family homes. Access to the site is
proposed off of S 47th Street which would end in two cul-de-sacs.
Current Use: The site is currently vacant.
Zoning: The subject site is split zoned Residential 8 net du/ac (R-8), Residential 1 net du/ac (R-1),
and Residential 14 net du/ac (R-14). The zoning is based upon the slopes at the subject site.
The eastern R-8 zoned property is divided from the R-1 property by the toe of the sensitive
slopes. The R-14 zoning is located in a small area on the west side of the property at the toe of
the slope. Additionally, the area zoned R-1 is located within the Urban Separator overlay. A
slope analysis survey would be required at the time of land use permit application identifying
and diagramming the toe of the slope to determine how much land area is located in which
zones. However the proposed subdivision appears to be isolated to the R-8 zoned portion of the
property. As such the following report addresses R-8 standards which would be applicable to
the proposed development location.
Zoning/Density Requirements: The subject property is located within the R-8 zoning
designation. The density range allowed in the R-8 zone is a minimum of 4.0 to a maximum of
8.0 dwelling units per acre (du/ac). The area of public and private streets and critical areas
Schneider Preliminary Plat, PRE12-070
Page 2 of 5
September 13, 2012
h:\ced\planning\current planning\preapps\12-070.vanessa\12-070 (r-8, r-14 & r-1 schneider plat, urban separator,
erosion, landslide, slopes, wetlands).doc
would be deducted from the gross site area to determine the “net” site area prior to calculating
density.
The application materials identified that 4.55 net acres would be applicable to the subject
development. Based on the provided information, the proposed lot 27 lot subdivision would
result in a net density of 5.93 du/ac. Based on the above calculations is appears the subject
development would be compliant with the R-8 density regulations. However, it was noted in
the application that the area dedicated to steep slopes was not completed by a survey. A survey
would be required at the time of formal land use application to determine the toe of the slope,
R-1 and R-8 boundary and land area for each zone, in order for staff to confirm that the project
complies with the density provisions of the zone.
Development Standards: The project would be subject to RMC 4-2-110A, “Development
Standards for Single Family Zoning Designations” effective at the time of complete application.
As the majority of the subject site is located in the R-8 zone the below information is
applicable to that portion of the site subject to R-8 standards.
Minimum Lot Size, Width and Depth – The minimum lot size permitted in the R-8 is 4,500 square
feet for parcels greater than 1 acre in size and 5,000 square feet for lots 1 acre or less in size.
The total lot area of the subject site is more than 1 acre; therefore a minimum lot size of 4,500
square feet is applicable to the proposed project. A minimum lot width of 50 feet for interior
lots and 60 feet for corner lots, as well as a minimum lot depth of 65 feet, is also required. The
proposal appears to comply with the lot size, width and depth requirements of the zone.
However, a number of the lots are designed in an odd shape, due to their shape staff was
unable to determine compliance with lot width and depth requirements. Detailed information
regarding lots size would be required at Preliminary Plat submittal to show compliance with
lot width and depth requirements.
Lot Configuration – One of the following is required:
1. Lot width variation of 10 feet (10') minimum of one per four (4) abutting street-fronting
lots, or
2. Minimum of four (4) lot sizes (minimum of four hundred (400) gross square feet size
difference), or
3. A front yard setback variation of at least five feet (5') minimum for at least every four (4)
abutting street fronting lots.
Building Standards – R-8 zone allows a maximum building coverage of 35% of the lot area or
2,500 square feet, whichever is greater for lots over 5,000 square feet in size and a maximum
impervious surface 75%. Building height is restricted to 30 feet from existing grade. Detached
accessory structures must remain below a height of 15 feet. The gross floor area must be less
than that of the primary structure. Accessory structures are also included in building lot
coverage calculations. The proposal’s compliance with the building standards would be
verified at the time of building permit review for the new residences to be located on all lots.
Building Design Standards – All single family residences would be subject to the Residential
Design Standards outlined in RMC 4-2-115. The proposal’s compliance with the residential
design standards would be verified at the time of building permit review for the new
residences to be located on all lots.
Schneider Preliminary Plat, PRE12-070
Page 3 of 5
September 13, 2012
h:\ced\planning\current planning\preapps\12-070.vanessa\12-070 (r-8, r-14 & r-1 schneider plat, urban separator,
erosion, landslide, slopes, wetlands).doc
Setbacks – Setbacks are the minimum required distance between the building footprint and the
property line and any private access easement. The required setbacks in the R-8 zone are 15
feet in front for the primary structure and 20 feet in front for the attached garage, 20 feet in the
rear, 5 feet on interior side yards, and 15 feet on side yards along streets (including access
easements) for the primary structure and 20 feet on side yards along streets (including access
easements) for the attached garage. The setbacks for the new residences would be reviewed at
the time of building permit.
Access/Parking: Access to the site is proposed off of S 47th Street which would end in two cul-
de-sacs.RMC 4-7-150, Streets– General Requirements and Minimum Standards, requires that
the proposed street system extend and create connections between existing streets. A grid
street pattern is required to be used to connect existing and new development and shall be the
predominant street pattern in any subdivision. In order to provide the opportunity for a future
street grid pattern and a potential secondary fire access the proposed internal road should be
extended to the east. This road would eventually connect with SE 186th Street and Main
Avenue South, if the parcels to the east develop in the future.
Alley access is the preferred street pattern except for properties in the Residential Low Density
land use designation. Prior to approval of a plat without alley access, the Reviewing Official shall
evaluate an alley layout and determine that the use of alley(s) is not feasible.
Each lot is required to accommodate off street parking for a minimum of two vehicles.
Driveways: The maximum driveway slopes cannot exceed 15%, provided that driveways
exceeding 8% are to provide slotted drains at the lower end of the driveway. If the grade
exceeds 15%, a variance is required.
Landscaping – Except for critical areas, all portions of the development area not covered by
structures, required parking, access, circulation or service areas, must be landscaped with
native, drought-resistant vegetative cover. The development standards require that all pervious
areas within the property boundaries be landscaped. The minimum on-site landscape width
required along street frontages is 10 feet.
Please refer to landscape regulations (RMC 4-4-070) for further general and specific landscape
requirements (enclosed). A conceptual landscape plan shall be submitted at the time of
Preliminary Plat application.
Significant Tree Retention: If significant trees (greater than 6-inch caliper) are proposed to be
removed a tree inventory and a tree retention plan along with a tree retention worksheet shall
be provided with the formal land use application. The tree retention plan must show
preservation of at least 30 percent of significant trees, and indicate how proposed building
footprints would be sited to accommodate preservation of significant trees that would be
retained. If the trees cannot be retained, they may be replaced with minimum 2 inch caliper
trees at a ratio of six to one.
Urban Separator: Approval of a plat, and/or building permit on an undeveloped legal lot in the
Talbot Urban Separator Overlay shall require dedication of fifty percent (50%) of the gross land
area of that portion of the parcel or parcels located within the Urban Separator as a non-
revocable open space tract retained by the property owner, or dedicated to a homeowners
association or other suitable organization as determined by the reviewing official. In order to
satisfy the dedication requirement, some of the area to be dedicated may consist of land
abutting the Urban Separator, as determined by the Planning Director, on a case-by-case basis.
Schneider Preliminary Plat, PRE12-070
Page 4 of 5
September 13, 2012
h:\ced\planning\current planning\preapps\12-070.vanessa\12-070 (r-8, r-14 & r-1 schneider plat, urban separator,
erosion, landslide, slopes, wetlands).doc
Acreage in tracts may include critical areas and/or critical area buffers. At a minimum, open
space shall be connected to another contiguous open space parcel by a fifty foot (50') corridor.
Development shall be clustered outside the contiguous open space corridor.
Forest/vegetation clearing shall be limited to a maximum of thirty five percent (35%) of the
gross acreage of the site. Forest/vegetation cover may include a combination of Northwest
native vegetation including conifer, deciduous trees and shrubs sufficient to provide water
retention and erosion control, as determined appropriate by the Reviewing Official. The
Reviewing Official shall determine whether existing vegetation provides functions to meet
forest/vegetation coverage standards, and shall require additional plantings if existing
vegetation is found to be insufficient.
Landscape plans required in RMC 4-4-070 shall include retention/replanting plans as applicable,
consistent with standards and plant lists in King County Department of Natural Resources and
Parks Water and Land Resources Division Publication “Going Native.”
Critical Areas: The City of Renton’s Sensitive Areas maps indicate the presence of
“protected and sensitive slopes”, erosion hazards, high landslide hazards and a potential
for wetlands on the subject site.
Protected slopes are defined as topographical features that slope in excess of 40% and have
a vertical rise of 15 feet or more. If any work is planned on a “protected slope” a Variance
from the Critical Areas regulations would be required. Please note the burden would be on
the applicant to demonstrate that there is no feasible alternative other than to disturb the
“protected slopes.”
A subdivision in which the average slope is twenty percent (20%) or in which any street in
the subdivision has grades greater than fifteen percent (15%) at any point would be
considered a Hill Side Subdivision. Additional review criteria and submittal information is
required for Hill Side Subdivisions.
In any event, erosion hazards, high landslide hazards and steep slopes are Geological
Hazards therefore, a geotechnical study shall be provided by a qualified professional. The
study shall demonstrate that the proposal will not increase the threat of the geological
hazard to adjacent properties beyond the pre-development conditions, the proposal will not
adversely impact other critical areas, and the development can be safely accommodated on
the site. In addition, the study shall assess soil conditions and detail construction measures
to assure building stability.
A wetland reconnaissance shall be provided, clarifying the presence of wetlands on site. If
wetlands are determined to be located on or near the subject site, a wetland assessment
and delineation would also be required.
Environmental Review: Environmental (SEPA) Review is required for projects nine lots or
greater, or on sites that contain critical areas.
Permit Requirements:
The proposed subdivision would require Preliminary Plat Approval and SEPA Environmental
Review. All land use permits would be processed within an estimated time frame of 12 weeks.
The Preliminary Plat Review application fee is $4,000 and the SEPA Environmental Review is
$1,000. A 3% technology fee would also be assessed at the time of land use application.
Schneider Preliminary Plat, PRE12-070
Page 5 of 5
September 13, 2012
h:\ced\planning\current planning\preapps\12-070.vanessa\12-070 (r-8, r-14 & r-1 schneider plat, urban separator,
erosion, landslide, slopes, wetlands).doc
Detailed information regarding the land use application submittal is provided in the attached
handouts.
Fees: In addition to the applicable building and construction fees, the following mitigation fees
would be required prior to the recording of the plat. Impact fees, which would replace
mitigation fees, may be adopted prior to construction. Those fees are to be determined. The
following are current fees:
A Fire Mitigation fee of $488.00 per new single family residence.
A Transportation Mitigation Fee based on $75.00 per each new average
daily trip attributable to the project; and
A Parks Mitigation Fee based on $530.76 per new single family residence.
A Renton School District Impact Fee based on $6,310 per new single
family residence.
A handout listing all of the City’s Development related fees in attached for your review.
Expiration: The preliminary plat approval is valid for seven years with a possible one-year
extension.
cc: Jennifer Henning
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:September 7, 2012
TO:Vanessa Dolbee, Planner
FROM:Arneta Henninger, Plan Review
SUBJECT:Utility and Transportation Comments for:
Schneider Plat
South of S. 47TH ST & Smithers Ave S
Pre 12-070, Parcel 3123059048
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official city decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the above-referenced 27-lot plat proposal, located at the end
of Smithers Ave S., just south of S. 47th St in Sect. 31, Twp 23N Rng 5 E. The following comments are
based on the pre-application submittal made to the City of Renton by the applicant.
Water
1. The proposed subdivision is within the City of Renton retail water service area. However, there is no
City water main in the vicinity of the development that can be extended to provide the necessary water
pressure.
2. It appears that Soos Creek Water & Sewer District (SCWSD) has an existing water main along the
north side of the property that can be extended to serve the subject development. The applicant shall
contact SCWSD and obtain a certificate of water availability.
3. The City’s Water Utility will be able to release the water service to this property to SCWSD upon
confirmation that the District can provide water service to the proposed development.
4. Per the City Fire Marshal, the preliminary fire flow requirement for a single family home is a
minimum 1,000 gpm for dwellings up to 3,600 square feet (including garage and basements). If the
dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A minimum
of one fire hydrant is required within 300-feet of the proposed buildings; two hydrants if the fire flow
goes up to 1,500 gpm. Lateral spacing of fire hydrants is predicated on hydrants being located at street
intersections.
5. All fire hydrants need to be brought up to current code if not existing.
Schneider Plat PRE 12-070
Page 2 of 3
September 7, 2012
H:\CED\Planning\Current Planning\PREAPPS\12-070.Vanessa\Plan Review Comments PRE 12-070.doc
6. The City of Renton System Development Charges (SDC) are based on the size of the domestic water
meters. These fees are collected at the time a construction permit is issued.
Sanitary Sewer
1. This site is located in the City of Renton sanitary sewer service boundary.
2. There is an existing 8” sewer main in Smithers Ave S. See City of Renton sanitary sewer drawing #S-
2776 for details.
3. Project plans need to show how sanitary sewer will be provided to each unit with an individual sewer
service line. Per code, sanitary sewer needs to be extended along the full frontage of the parcel being
developed.
4. This proposal appears to be located in Special Assessment District (SAD) 0013 and 8406. SAD 8406 is
Valley Medical, and it appears to have been paid. SAD 0013 is the Summit Park Latecomer, and it also
appears to have been paid.
5. Sanitary Sewer SDC fees are based on the size of the domestic water meters. These fees are
collected at the time a construction permit is issued.
Storm Drainage
1. There are existing storm drainage facilities in S. 47th St and in Smithers Ave S. See drawing #R-2776.
2. A drainage plan and drainage report will be required with the site plan application. The report shall
comply with the 2009 King County Surface Water Manual and the 2009 City of Renton Amendments to
the KCSWM, Chapters 1 and 2. All core and any special requirements shall be contained in the report.
Based on the city’s flow control map, this site falls within the Flow Control Duration Standard, Forested
Conditions. The drainage report will need to follow the area specific flow control requirements under
Core Requirement #3.
3. A geotechnical report for the site is required. Information on the water table and soil permeability
with recommendations of appropriate flow control BMP options with typical designs for the site, from
the geotechnical engineer, shall be submitted with the application.
4. Surface Water SDC fees are $1,012 per lot if individually owned or $0.405 per square foot of new
impervious area if lots are not individually owned. These fees are collected at the time a construction
permit is issued.
Transportation/Street
1. Installation of curb, gutter, sidewalk, and street lighting is required on the full frontages of the parcel
being developed. The internal street is required to be extended to the southeast boundary of the parcel
to provide future connection to SE 186th Street and Main Avenue South.
2. Street improvements for the interior road are 32 feet in pavement width. The right-of-way is to be
58 feet in width, with an 8-foot planter strip and a 5-foot sidewalk. Additional right-of-way not required.
3. Street lighting shall be per current City of Renton standards and specifications. The residential
decorative lighting on black poles spaced approximately 110’ is required. See City of Renton details.
4. Per City of Renton code, all lot corners at intersections of dedicated public right-of-ways shall have a
minimum radius of 15 feet.
Schneider Plat PRE 12-070
Page 3 of 3
September 7, 2012
H:\CED\Planning\Current Planning\PREAPPS\12-070.Vanessa\Plan Review Comments PRE 12-070.doc
5. All new electrical, phone, and cable services and lines must be undergrounded. The construction of
these franchise utilities must be inspected and approved by a City of Renton public works inspector prior
to recording the plat.
6. Traffic mitigation or impact fees apply; these fees are approximately $750 per lot.
7. A traffic study is required.
General Comments
1. All required utility, drainage, and street improvements will require separate plan submittals
prepared according to City of Renton drafting standards by a licensed Civil Engineer.
2. All plans shall be tied to a minimum of two of the City of Renton Horizontal and vertical Control
Network.
3. Permit application must include an itemized cost estimate for these improvements. Half of the fee
must be paid upon application for building and construction permits, and the remainder when the
permits are issued. There will be additional fees for water service related expenses. See Drafting
Standards.
FIRE & EMERGENCY SERVICES DEPARTMENT
M E M O R A N D U M
DATE:August 15, 2012
TO:Vanessa Dolbee, Senior Planner
FROM:Corey Thomas, Plans Review Inspector
SUBJECT:Preliminary comments for Schneider Preliminary Plat
1. The fire flow requirement for a single family home is 1,000 gpm
minimum for dwellings up to 3,600 square feet (including garage and
basements). If the dwelling exceeds 3,600 square feet, a minimum of
1,500 gpm fire flow would be required. A minimum of one fire hydrant
is required within 300-feet of the proposed buildings and two hydrants
if the fire flow goes up to 1,500 gpm. Existing fire hydrants can be
counted toward the requirements as long as they meet current code
including 5-inch storz fittings. A water availability certificate is
required from Soos Creek Water and Sewer District.
2. The fire mitigation impact fees are currently applicable at the rate
of $488.00 per single family unit. This fee is paid prior to recording
the plat.
3. Fire department apparatus access roadways are required to be a
minimum of 20-feet wide fully paved, with 25-feet inside and 45-
feet outside turning radius. Fire access roadways shall be
constructed to support a 30-ton vehicle with 322-psi point loading.
Access is required within 150-feet of all points on the buildings.
Approved apparatus turnarounds are required for dead end roads
exceeding 150-feet. Cul-de-sac turnarounds of 90-foot diameter
are required for dead end streets over 500-feet long. Dead end
streets exceeding 500-feet require all homes to be provided with
an approved fire sprinkler system. Dead end streets exceeding
700-feet are not allowed without approved secondary access
roadways being provided. Access as proposed will not meet
current code. Street system shall be designed to be extended to
adjoining underdeveloped properties for future extension.