HomeMy WebLinkAboutSumary_Preapp_Mtg_PRE12-000074H:\CED\Planning\Current Planning\PREAPPS\12-074.Jerry\Plan Review Comments PRE 12-074.doc
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:September 20, 2012
TO:Jerry Wasser, Planner
FROM:Arneta Henninger, Plan Review
SUBJECT:Sharon Travis Shaw Renton Church
11635 SE 170TH PL
Parcel 1432401000
PRE 12-074
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official city decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review on the above-referenced proposal for a Conditional Use permit to
operate as a church. The proposal is located in the SW 1/4 of Section 28, Township 23N, Range 5E. The
following comments are based on the pre-application submittal made to the City of Renton by the
applicant.
Water
1. This site is not located in the City of Renton Water service area; it is located in the Soos Creek Water
District. A Certificate of Water Availability will be required to be submitted with the formal application.
2. Project site is not located in the Aquifer Protection Zone.
3. Per the City Fire Marshal, the minimum fire flow requirement for the existing building is 1,500 gpm.
Per the Renton Fire Department, existing fire apparatus access is adequate.
Sanitary Sewer
This site is not located in the City of Renton Sanitary Sewer service area; it is located in the Soos Creek
Sewer District. A Certificate of Sanitary Sewer Availability will be required to be submitted with the
formal application.
Storm Drainage
There are no storm requirements for this conditional use as a church.
Transportation/Street
1. Construction of a commercial building, if there is one, will trigger a separate review.
2. Traffic Mitigation fees may be applicable if there is a net increase in traffic.
h:\ced\planning\current planning\preapps\12-074.jerry\pre12-074,sharon travis shaw renton church church.doc
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:September 20, 2012
TO:Pre-application File No. 12-074
FROM:Gerald Wasser, Associate Planner
SUBJECT:Sharon Travis Shaw Renton Church
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and
permitting issues are based on the pre-application submittals made to the City of
Renton by the applicant and the codes in effect on the date of review. The applicant is
cautioned that information contained in this summary may be subject to modification
and/or concurrence by official decision-makers (e.g., Hearing Examiner, Community &
Economic Development Administrator, Public Works Administrator, Planning Director,
Development Services Director, and City Council). Review comments may also need to
be revised based on site planning and other design changes required by City staff or
made by the applicant. The applicant is encouraged to review all applicable sections of
the Renton Municipal Code. The Development Regulations are available for purchase
for $100.00 plus tax, from the Finance Division on the first floor of City Hall or online at
www.rentonwa.gov
Project Proposal: The subject property is located at 11635 SE 170th Place (APN
1432401000). The project site is 10,005 square feet in area and is zoned Residential-8
dwelling units per acre (R-8). A proposal has been submitted to convert an existing
1,440 square foot single-family residential structure into a church. The applicant has
indicated that no modifications to the existing structure are proposed. The applicant
has not provided a site plan which indicates how vehicular access would be provided
to the site.
Current Use: The property is developed with one single-family residential structure and
two sheds. The applicant states the structure was used as a public library, a church and
a daycare facility in the past. Please note that King County Assessor records indicate
that the last use of the property was for a daycare center (Brighter Future Learning
Center) which was owned by the Renton Pentecostal Church.
Consistency with Comprehensive Plan: The subject property is within the Residential
Single Family Comprehensive Plan Land Use Designation (RSF). The following objective
and policy are applicable to the proposal:
Sharon Travis Shaw Church, PRE12-074
Page 2 of 4
September 20, 2012
h:\ced\planning\current planning\preapps\12-074.jerry\pre12-074,sharon travis shaw renton church church.doc
Land Use Element
Objective LU-X: Site religious and ancillary facilities in a manner that provides
convenient transportation access and minimizes their adverse impacts on adjacent land
uses.
Policy LU-111: Parking should be provided on-site and buffered from adjacent land
uses.
These Comprehensive Plan policies do not appear to be satisfied. There is no
convenient transportation access and there does not appear to be a plan for providing
on-site parking.
Zoning/Density Requirements: The subject property is zoned Residential-8 dwelling
units per acre (R-8). Religious institutions in this zone require a Hearing Examiner
Conditional Use Permit. This process requires a public hearing before the City of
Renton Hearing Examiner.
Development Standards: The project would be subject to RMC 4-2-110A, “Development
Standards for Single Family Zoning Designations” effective at the time of complete
application. A copy of these standards is included.
Signs – If a Conditional Use Permit is approved, churches located in residential zones
may have two on-premises identifying signs of not over thirty two square feet in area on
one face. The signs may be illuminated but not animated, shall be for location
identification only and shall display no copy, symbol or device other than in keeping
with the development. Freestanding signs shall not be higher than six feet above any
established grade and shall be no closer than ten feet to any street right-of-way or five
feet to any side property line. Conformance with sign regulations would be verified
prior to sign permit issuance.
Access/Parking: There appears to be an area in the northwest corner of the subject
property which may be used for vehicle parking by the applicant. However, this area
may be problematic in that it appears one car at most may be accommodated. The
configuration of this area (triangular) would necessitate cars to back out onto SE 168th
Avenue. Pursuant to RMC 40-4-080F.10.e religious institutions require a minimum and
maximum of 1 parking space for every 5 seats in the main auditorium; however, in no
case shall there be less than 10 parking spaces. Because the applicant has not provided
floor plans, it is not possible to determine the required number of parking spaces.
However, it does not appear to be possible to provide the minimum of 10 parking
spaces on the subject site. Parking areas must be developed in compliance with
Renton Municipal Code Section 4-4-080 including dimensions, aisle width, paving,
striping and landscaping.
Landscaping: Appropriate landscaping would be required if the project meets the
applicability requirements of RMC 4-4-070B.
Sharon Travis Shaw Church, PRE12-074
Page 3 of 4
September 20, 2012
h:\ced\planning\current planning\preapps\12-074.jerry\pre12-074,sharon travis shaw renton church church.doc
Significant Tree Retention: If any trees are to be removed, a tree inventory and a tree
retention plan along with a tree retention worksheet shall be provided with the formal
land use application. The tree retention plan must show preservation of at least 30
percent of significant trees, and indicate how proposed building footprints would be
sited to accommodate preservation of significant trees that would be retained. If the
trees cannot be retained, they may be replaced with minimum 2 inch caliper trees at a
ratio of six to one. At this time, no tree clearing is anticipated.
Critical Areas: The site contains no mapped critical areas.
Environmental Review: The proposed project would not require Environmental (SEPA)
Review.
Permit Requirements: The proposal would require approval of a Hearing Examiner
Conditional Use Permit. The review process would require a public hearing and would
be completed in an estimated time frame of six to eight weeks. The application fee for
Hearing Examiner Review of Conditional Use applications is $2,060.00 ($2,000.00 plus
3% Technology Surcharge Fee). Detailed information regarding the land use
application submittal is provided in the attached handouts.
Conditional Use Criteria: In order to obtain approval of a conditional use, the proposal
must satisfy specific criteria. The purpose of a conditional use permit is to allow certain
uses in districts from which they are ordinarily prohibited. The evaluation of the
proposed use must be deemed consistent with other existing and potential uses within
the general area of the site. It is the applicant’s responsibility to adequately
demonstrate the facts justifying the approval of the conditional use permit based on
the following decision criteria (RMC Section 4-9-030D):
Consistency with plans and regulations ;
Appropriate location;
Effect on adjacent properties;
Compatibility;
Parking;
Traffic;
Noise, Light, and Glare; and
Landscaping.
The criteria above must be clearly and thoroughly substantiated. Staff examines the
existing uses located adjacent to the subject site when evaluating the conditional use
criteria. It is the burden of the applicant to demonstrate that this site is appropriate
for the use proposed. It is important to note that staff is only able to make a
recommendation and that the Hearing Examiner makes the final decision for a
conditional use permit.
Sharon Travis Shaw Church, PRE12-074
Page 4 of 4
September 20, 2012
h:\ced\planning\current planning\preapps\12-074.jerry\pre12-074,sharon travis shaw renton church church.doc
Expiration: Upon approval, the short plat is valid for two years with a possible one year
extension.