HomeMy WebLinkAboutSummary_Preapp_Mtg_PRE12-000282PREAPPLICATION MEETING FOR
Walker Subaru Addition & Remodel
555 SW Grady Way
PRE 12-000282
CITY OF RENTON
Department of Community & Economic Development
Planning Division
January 3, 2013
Contact Information:
Planner: Rocale Timmons, 425.430.7219
Public Works Plan Reviewer: Jan Illian, 425.430.7216
Fire Prevention Reviewer: Corey Thomas, 425.430.7024
Building Department Reviewer: Craig Burnell, 425.430.7290
Please retain this packet throughout the course of your project as a reference. Consider
giving copies of it to any engineers, architects, and contractors who work on the
project. You will need to submit a copy of this packet when you apply for land use
and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the project manager to have it pre-screened before
making all of the required copies.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and the
proposal will be formally reviewed under the regulations in effect at the time of project
submittal. The information contained in this summary is subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director,
Development Services Director, Department of Community & Economic Development
Administrator, Public Works Administrator and City Council).
i:\rtimmons\preapps\12-000282 (ca - walker subaru ti).doc
DEPARTMENT OF
COMMUNITY AND ECONOMIC
DEVELOPMENT
M E M O R A N D U M
DATE:January 3, 2013
TO:Pre-Application File No. 12-000282
FROM:Rocale Timmons, Associate Planner
SUBJECT:Walker Subaru Addition & Remodel
Parcel #’s: 334040-4470 and 334040-4265
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official
decision-makers (e.g., Hearing Examiner, Community & Economic Development Administrator,
Public Works Administrator, Planning Director, Development Services Director, and City
Council). Review comments may also need to be revised based on site planning and other
design changes required by City staff or made by the applicant. The applicant is encouraged to
review all applicable sections of the Renton Municipal Code. The Development Regulations are
available for purchase for $50.00 plus tax, from the Finance Division on the first floor of City Hall
or online at www.rentonwa.gov
Project Proposal: The subject property is located on the east side of Seneca Ave SW between
SW Grady Way and I-405 at; 555 SW Grady Way and 519 SW 12th St. The project site totals
3.625 acres in area and is located within the Commercial Arterial (CA) zone. The pre-application
packet indicates that the proposal is to perform a tenant improvement for two existing
structures in order to accommodate Renton Walker Subaru. Minor modifications include the
demolition of an existing canopy which would be replaced by a larger canopy on the northeast
corner of the structure at 555 SW Grady Way. The structures were formerly occupied by Saturn
of Renton. The project site does not appear to contain any critical areas.
Current Use: The property is contains two existing structures formerly occupied by Saturn of
Renton.
Zoning: The property is located within the Commercial Corridor (CC) land use designation and
the Commercial Arterial (CA) zoning classification. The property is also within Area ‘A’ of the
Automall overlay district. A car dealership is a permitted use in the CA zone and Area ‘A’ of the
Automall overlay district. The property is also located within Urban Design District ‘D’, and is
subject to additional design elements. Proposals are required have unique, identifiable design
treatment in terms of landscaping, building design, signage and street furniture.
Walker Subaru Addition & Remodel
Page 2 of 4
January 3, 2013
i:\rtimmons\preapps\12-000282 (ca - walker subaru ti).doc
Development Standards: The project would be subject to RMC 4-2-120A, “Development
Standards for Commercial Zoning Designations” effective at the time of complete application
(noted as “CA standards” herein).
Minimum Lot Size, Width and Depth – There are no minimum requirements for lot size, lot
width or depth within the CA zone at this location.
Lot Coverage – The CA zone allows a maximum building coverage of 65 percent, or 75 percent if
parking is provided within a building or within an on-site parking garage. The proposal appears
to comply with the lot coverage requirements of the zone.
Setbacks – Setbacks are the distance between the building and the property line or any private
access easement. Setback requirements in the CA zone are as follows: 10 feet minimum for the
front yard but may be reduced to zero feet through the Site Plan Review process provided blank
walls are not located within the reduced setback; and a 15 foot maximum front yard setback.
The existing structures do not comply with the maximum front yard setback requirement.
However, as the situation is existing and the proposed additions would bring the structure
closer to conformity a modification would not be required.
Gross Floor Area – There is no minimum requirements for gross floor area within the CA zone.
Building Height – The maximum building height that would be allowed in the CA zone is 50 feet.
It appears the height of the existing structure is well beneath the 50-foot maximum. Building
elevations and detailed descriptions of elements and building materials are required with your
permit review submittal.
Screening – Screening must be provided for all surface-mounted and roof top utility and
mechanical equipment. The site plan application will need to include elevations and details for
the proposed methods of screening.
Refuse and Recycling Areas – Refuse and recycling areas need to meet the requirements of RMC
4-4-090, “Refuse and Recyclables Standards” (enclosed). For commercial developments a
minimum of 5 square feet per every 1,000 square feet of building gross floor area shall be
provided for recyclable deposit areas and a minimum of 10 square feet per 1,000 square feet of
building gross floor area shall be provided for refuse deposit areas with a total minimum area of
100 square feet.
The location and size of the refuse and recyclable area could not be verified with the pre-
application materials.
Landscaping – Except for critical areas, all portions of the development area not covered by
structures, required parking, access, circulation or service areas, must be landscaped with
native, drought-resistant vegetative cover. The development standards require that all pervious
areas within the property boundaries be landscaped. The minimum on-site landscape width
required along street frontages is 10 feet, except where reduced through the site plan
development review process. However, properties located within Automall A are required to
provide a 15-foot-wide landscape strip along SW Grady Way. This frontage requirement is in
lieu of the frontage requirement listed for the zone in RMC 4-2. Unimproved portions of the
right-of-way may be used in combination with abutting private property to meet the required
15-foot landscape strip width. The landscaping shall include a minimum 30-inch-high berm
and red maples (Acer rubrum) planted 25 feet on center.
Walker Subaru Addition & Remodel
Page 3 of 4
January 3, 2013
i:\rtimmons\preapps\12-000282 (ca - walker subaru ti).doc
In addition, in Area ‘A’ of the Automall, a minimum of 2.5 percent of the gross site area shall
be landscaped. The landscaping must be consolidated and located at site entries, the front of
the building, or other visually prominent.
Please refer to landscape regulations (RMC 4-4-070) for additional general and specific
landscape requirements (enclosed). A conceptual landscape plan and landscape analysis
meeting the requirements in RMC 4-8-120D.12, shall be submitted at the time of application for
Site Plan Review.
Parking – The following ratios would be applicable to the site:
Use Square Footage of
Use
Ratio Required Spaces
Commercial 9,000 SF 1 space/5,000 SF 2
Vehicle service
and repair
19,292 2.5 spaces / 1,000 SF 48
It is unclear how many parking stalls will be required as detailed information was not provided
for the net square footage of the existing structure. The applicant would be required to
provide detailed information on the proposed uses of the structure. Where practical difficulties
exist in meeting parking requirements, the applicant may request a modification from these
standards. The applicant will be required at the time of formal land use application to provide
detailed parking information (i.e. stall and drive aisle dimensions) and calculations of the subject
site and the overall campus use.
It should be noted that the parking regulations specify standard stall dimensions. Surface
parking stalls must be a minimum of 9 feet x 20 feet, compact dimensions of 8½ feet x 16 feet,
and parallel stall dimensions of 9 feet x 23 feet; compact surface parking spaces shall not
account for more than 30 percent of the spaces in the surface parking lots.
ADA accessible stalls must be a minimum of 8 feet in width by 20 feet in length, with an adjacent
access aisle of 8 feet in width for van accessible spaces. The appropriate amount of ADA
accessible stalls based on the total number of spaces must be provided. Please refer to
landscape regulations (RMC 4-4-070 and RMC 4-4-080F.7) for further general and specific
landscape requirements (enclosed).
Additionally, the proposal would need to be revised in order to provide bicycle parking based
on 10 % of the required number of parking stalls.
Access – Driveway widths are limited by the driveway standards, in RMC 4-4080I.
Pedestrian Access – A pedestrian connection shall be provided from all public entrances to the
street, in order to provide direct, clear and separate pedestrian walks from sidewalks to building
entries and internally from buildings to abutting properties. The applicant would be required to
revise the proposed site plan to include a pedestrian connection directly from SW Grady Way
to the entrance along the northern façade.
Signage – Only one freestanding business sign (restricted to monument/ground signs only) is
permitted per street frontage, however pole signs are not permitted within the CA zone. Each
sign shall not exceed an area greater than one and one-half square feet for each lineal foot of
Walker Subaru Addition & Remodel
Page 4 of 4
January 3, 2013
i:\rtimmons\preapps\12-000282 (ca - walker subaru ti).doc
property frontage that is occupied by the business. In no case shall the sign exceed a total of
300 square feet (150 square feet per face). The ground/monument sign is limited to 5 feet in
height. In addition to the permitted freestanding sign, wall signs with a copy area not exceeding
20% of the façade, to which it is applied, are also permitted. Please note that all cabinet
signage is prohibited.
Building Design Standards – Compliance with Urban Design Regulations, District ‘D’, is
required. See the attached checklist and Renton Municipal Code section 4-3-100. The following
bullets are a few of the standards outlined in the regulations which will be verified at building
permit submittal.
A primary entrance of each building shall be located on the facade facing a street, shall
be prominent, visible from the street, connected by a walkway to the public sidewalk,
and include human-scale elements.
Parking shall be located so that no surface parking is located between a building and
the front property line, or the building and side property line, on the street side of a
corner lot.
All building facades shall include modulation or articulation at intervals of no more than
forty feet (40').
Modulations shall be a minimum of two feet (2') deep, sixteen feet (16') in height, and
eight feet (8') in width.
On any facade visible to the public, transparent windows and/or doors are required to
comprise at least fifty percent (50%) of the portion of the ground floor facade that is
between four feet (4') and eight feet (8') above ground (as measured on the true
elevation).
Buildings shall use at least one of the following elements to create varied and
interesting roof profiles (see illustration, subsection RMC 4-3-100.I5f):
(a) Extended parapets;
(b) Feature elements projecting above parapets;
(c) Projected cornices;
(d) Pitched or sloped roofs.
Buildings shall employ material variations such as colors, brick or metal banding,
patterns, or textural changes.
Critical Areas
There are no critical areas located on site.
Environmental Review
The project is Categorically Exempt from SEPA requirements and, therefore, Environmental
Review would not be required.
Permit Requirements
The proposal would require a building permit for any tenant improvements needed to
accommodate the commercial use. The applicant will also be subject to Design Review as part
of the Building Permit application and a Design Checklist shall be completed and submitted as
part of the application materials.
H:\CED\Planning\Current Planning\PREAPPS\12-000282.Rocale\Plan Review Comments PRE 12-000282.docx
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:January 2, 2013
TO:Rocale Timmons, Planner
FROM:Jan Illian, Plan Review
SUBJECT:Walker Subaru Interior Remodel
555 & 519 – SW 12th Street
PRE 12-000282
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official city decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal. The following comments are
based on the pre-application submittal made to the City of Renton by the applicant.
General Comments
No utility related comments.