HomeMy WebLinkAbout20 - Floor Plans1437 South Boulder, Suite 550
Tulsa, Oklahoma 74119.3609
p: 918.587.8600
f: 918.587.8601
www.sgadesigngroup.com
108TH AVE SE NEAR NE CARR
RENTON, WA
PROJECT CONTACTS:PHONE #:
ARCHITECT: JEFF DALTON, AIA (918) 587-8600
SGA DESIGN GROUP, P.C.
SHEET NUMBER:SHEET TITLE:NOTE: THIS DRAWING IS FOR CONCEPTUAL PURPOSES
ONLY. SITE INFORMATION WAS OBTAINED FROM THE
CLIENTS DOCUMENTS; DESIGN MAY VARY.
4. ALL MASONRY DIMENSIONS ARE NOMINAL DIMENSIONS, MASONRY CONTRACTOR
TO ADJUST COURSING AS NEEDED.
1.WALL DIMENSIONS ARE TO FINISH CLEAR DIMENSION. ALL MATERIALS
MUST BE FIGURED INTO THE LAYOUT OF THE FRAMING.
2. MASONRY OPENING SHALL BE COORDINATED WITH WINDOW OR DOOR
MANUFACTURES REQUIREMENTS.
3. PLUMBING ROUGH INS ARE CRITICAL FOR ADA CLEARANCES, VERIFY
ALL PLUMBING ROUGH INS PRIOR TO INSTALLING ROOM FINISHES.
5. PROPOSED FIRE EXTINGUISHERS ARE LOCATED BY THE SYMBOL F.E.
COORDINATE TYPE, SIZE AND FINAL LOCATIONS WITH LOCAL FIRE OFFICIALS
GENERAL NOTES
6. ALL GYP. BRD. WALLS THAT DO NOT EXTEND TO DECK SHALL BE BE BRACED IN (2)
DIRECTIONS.
CMU1
MS3
MS2
MS1
MS4
FRP
8" HIGH CONCRETE MASONRY UNIT OR 4" HIGH QUIK BRICK WITH
HORIZONTAL REINFORCING AT 16" O.C. VERTICALLY. ALL
DECORATIVE SURFACES SHOULD FACE TO EXTERIOR SIDE ONLY.
REFER TO ELEVATIONS.
3 5/8" METAL STUDS AT 16" 0.C. WITH 5/8" GYPSUM BOARD BOTH
SIDES. EXTEND PARTITION TO DECK (TYPICAL U.N.O.). USE
MOISTURE RESISTANT GYPSUM BOARD ON INTERIOR SIDE OF
TOILET AND MOP BASIN AREAS.
3 5/8" METAL STUDS AT 16" 0.C. WITH 5/8" GYPSUM BOARD BOTH
SIDES WITH SOUND ATTENUATION BLANKETS BETWEEN. EXTEND
PARTITION TO DECK (TYPICAL U.N.O.) USE MOISTURE RESISTANT
GYPSUM BOARD ON INTERIOR SIDE OF TOILET AND MOP BASIN
AREAS AND BEHIND DRINKING FOUNTAINS.
3 5/8" METAL STUDS AT 16" 0.C. WITH 1/2" PLYWOOD BOTH SIDES,
PAINTED (TYPICAL UNLESS NOTED OTHERWISE).
FRP BOARD GLUE EDGE TO EDGE OF SUBSTRATE. REFER TO
INTERIOR ELEVATIONS ON SHEET A7 FOR HEIGHTS A.F.F.
NOTES:
1. SOME WALL TYPES MAY NOT BE USED. REFER TO PLANS
2. REFER TO STRUCTURAL DRAWINGS FOR STUD GAUGES AND
ADDITIONAL FRAMING INFORMATION.
MS5 6" METAL STUDS AT 16" 0.C. WITH 5/8" GYPSUM BOARD BOTH SIDES
WITH SOUND ATTENUATION BLANKETS BETWEEN. EXTEND
PARTITION TO DECK (TYPICAL U.N.O.) AT SIM. CONDITION, EXTEND
PARTITION 4" MIN. ABOVE CEILING. USE MOISTURE RESISTANT
GYPSUM BOARD ON INTERIOR SIDE OF TOILET AND MOP BASIN
AREAS.
1 1/2" "Z" FURRING AT 24" O.C. (ON MASONRY WALL) WITH 5/8"
GYPSUM BOARD. EXTEND 1 1/2" RIGID INSULATION TO DECK
ABOVE. (TYPICAL U.N.O.) USE MOISTURE RESISTANT GYPSUM
BOARD IN TOILET AND MOP SINK AREAS AND 6" METAL STUDS @16"
O.C. IN PLUMBING WALLS.
STANDARD WALL TYPES
CLF1
2 1/2" Ø GALV. STEEL POSTS AT 4' O.C. WITH 2" GALV.
CHAINLINK FABRIC. AT SIM. CONDITION; 4' X 8' SHEETS OF 3/4"
EXTERIOR GRADE PLYWOOD TO 12'-0" AFF ON INVENTORY SIDE
MS6
6" METAL STUDS AT 16" 0.C. WITH 1/2" PLYWOOD BOTH SIDES,
PAINTED.
CLF2 2 1/2" Ø GALV. STEEL POSTS AT 4' O.C. WITH 2" GALV. CHAINLINK
FABRIC STARTS AT 12'-8" AF.F. ON INVENTORY SIDE AND 4' X 8'
SHEETS OF 3/4" EXTERIOR GRADE PLYWOOD TO 12'-8 1/2" AFF
ON SERVICE BAY SIDE
MS7
6" METAL STUDS AT 16" 0.C. WITH 5/8" GYPSUM BOARD BOTH SIDES,
PAINTED.
CMU2
8" CONCRETE MASONRY UNIT WITH HORIZONTAL REINFORCING AT
16" O.C. VERTICALLY. SMOOTH FACES ON BOTH SIDES
(NO INSULATION IN INTERIOR WALLS)
MS8
3 5/8" METAL STUDS AT 16" 0.C. WITH 5/8" GYPSUM BOARD BOTH
SIDES, 3/4" PLYWOOD ATTACHED TO STUDS ON SHOP SIDE ONLY.
MARK DESCRIPTION
SANITARY NAPKIN DISPOSAL UNIT
PAPER TOWEL DISPENSER & DISPOSAL
MIRROR - SEE ELEVATIONS FOR SIZE
TOILET TISSUE DISPENSER
36" GRAB BAR WITH WOOD BACKER
42" GRAB BAR WITH WOOD BACKER, WITH 18" VERTICAL
BAR AS REQUIRED.A
B
C
D
E
F
G
H
COAT HOOK
HANDICAP SIGN-MOUNT 5'-0" AFF TO CENTER: 8"
EDGE TO JAMB EDGE.
I BABY CHANGING STATION. SEE DETAIL 1/N1
J 6 HALF LOCKER UNIT QTY(2)-(SECURE TO WALL)
NOTES
1. PROVIDE WOOD BLOCKING AS REQUIRED FOR MOUNTING ACCESSORIES
2. ACCESSORY PACKAGE AVAILABLE FROM NATIONAL VENDOR.
3. REFER TO SHEET N1 FOR MOUNTING HEIGHTS, LOCATIONS, ETC OR TOILET ROOM
ACCESSORIES.
K WRITING SURFACE, SEE DETAIL 11/A7
ACCESSORIES
2
A1
ENLARGED PLAN
NORTH
154'-0"
OVERALL 5'-0"121'-1 1/4"32'-10 3/4"10'-0"50'-0"OVERALL31'-4 1/2"12'-4 1/2"8'-8"R.O.4'-4"6'-0"R.O.40'-7 3/4"
4'-0"10'-0"
M.O.
2'-0"3'-4"
M.O.
3'-9 1/4"10'-0"
M.O.
3'-4"10'-0"
M.O.
3'-4"10'-0"
M.O.
3'-4"10'-0"
M.O.
3'-4"10'-0"
M.O.
3'-4"10'-0"
M.O.
3'-4"10'-0"
M.O.
3'-4"2'-0"31'-8"4'-4"M.O.5'-8"4'-4"M.O.4'-0"5'-0"5'-0"31'-8"9'-2"(3) EQ. SP.10
DOWNSPOUT TYP.
SEE ROOF PLAN
FOR LOCATIONS
12'-2 3/4"
STEP DOWN FROM
FINISH FLOOR TYPICAL
AT ALL OVERHEAD DOOR -
SEE STRUCTURAL
DRAWINGS
1"x12" WOOD
FORM, TYP.
ELECTRICAL SERVICE -
SEE ELECTRICAL
BAYS
SERVICE
108
INVENTORY
109INVENTORY
USED
110
09
26CLF2
SEE GRADING PLAN FORDEGREE OF SLOPE AT APRONT.O. CONC. APRONEL: 99'-9" TYP. AT EDGET.O. CONC. APRONEL: 99'-10 1/2" TYP. AT EDGEKNOX BOX &
ALARM STROBE
LOCATED PER FIRE
DEPT. IF REQUIRED
11
A4
8
A6
6
A4
1
A4
10
A6
TYP @ OH DOORS
14
A6
TYP @ SERVICE DOORS
7
A6
1
A5
SHOWROOM
CUSTOMER
100
18
A6
TYP @ OH DOOR JAMBS
16
A4
8
A6
9
A6
SIM.
16
A6
BACKFLOW AND DOMESTIC WATER
SERVICE. SEE PLUMBING SHEETS
AREA OF FIRE SPRINKLER
SERVICE AND BOLLARDS
T.O. CONCRETEEL: 100'-0" TYP @ PERIMETERCMU1
MS3
MS3
20 17 16 15 14 13 12 11 21
01
02
03
04
06
25
16'-8"
M.O.
6
A5
10
A5
5
A5
15
A5
10'-0"APRON CONTROL JOINTS
ARE TO BE LOCATED ON
THE CENTER OF EACH
PILASTER. (TYP.)
KEY DROP BOX
REFER. 16/A7
CMU1
1'-0"
1'-8"50'-0"OVERALL154'-0"
OVERALL
12
A6
F.E.
F.E.F.E.
F.E.
2918'-4"CMU1
4'-8 1/2"1'-4"
4'-0"
LINE OF CANOPY
ABOVE REFER 10/A4
A
B
C
D
15
A6
PROVIDE SIGN AT TOX ALERT SWITCH,
REFER E2. (RED SIGN/ WHITE LETTERS)
STATING "TURN EXHAUST FAN ON
ANYTIME GAS CADDY IS IN USE"
13456789101112
B
A
M
2
WH
SCALE:
FLOOR PLAN16
A1 1/8"=1'-0"
07
1'-3 1/2"44'-6"4'-8"
1'-10 3/4"
4'-0"48'-1 1/4"4'-0"
27'-6"
(7) EQUAL SPACES
CLF1
11
A6
20
A7 8
A6.1
8
A6.1
9
A6.1
8
A6.1 CLF2
MS2
6
A6.1
E
E
22
3'-4"
M.O.
3'-4"
E
113'-4 1/4"
CLF2
4'-0"16'-8"M.O.ALIGNMENT RACK RECESSED SLAB
OUTLINE AND FLOOR DRAIN SEE
STRUCT. AND PLBG. NOTE: PAINT
PERIMETER STEEL YELLOW TYPICAL
7
A6 SIM.
6"
44'-0"
(11) EQUAL SPACES 3'-0 3/4"
1'-0 1/2"11 1/4"
9 1/2"
5
A1
3'-0"
TYP.7'-0"62'-4 3/4"3'-0"8'-4 1/4"3'-0"24'-1"8'-6 5/8"6'-2"8'-1"
11 1/4"5'-10"45.0°45.0°11'-5"℄CLF1
20
A7
SIM.
SIM.
F
10'-8"M.O.8'-0"M.O.5'-0"
LINE OF CANOPY
ABOVE REFER 10/A4
LINE OF ROOF
ABOVE
LINE OF AWNING ABOVE LINE OF AWNING ABOVE
GAS SERVICE. SEE PLUMBING
SHEETS
LINE OF AWNING ABOVE1'-7"5'-1 7/8"
CLR.
1'-6"
CLR.7'-6 1/4"2 1/8"4 7/8"18'-8 7/8"7 1/2"7'-2"ALL LOCATIONS AND
DIMENSIONS ARE
CRITICAL IN THIS
PLAN. ADA
CLEARANCES ARE
TO BE VERIFIED
PRIOR TO SETTING
FINISHES.
SHELVES
ABOVE
TOILET
UNISEX
103
SHOWROOM
CUSTOMER
100
OFFICE
102
AREA
CLEAN UP
104
AREA
BREAK
105
AREA
CHANGING
106
℄℄A
C
B D1
A7
TOILET
SHOP
107
A
C
B D4
A7
G
CMU1
A
C
B D6
A7
MS2 1'-6"SHELF
& ROD
C
3"3'-5 1/2"6'-1 3/4"MS3
MS5
7'-1 7/8"
CLR.
2 1/8"7 5/8"
H
4'-0"15'-11 1/2"
A
CLOSET
'IT'
101
MS2
PHONE
BOARD
5'
-
0
"
2'-9 3/8"
2 1/8"
SHELVING
IT-ELEV.
REFER
10/A7OVERHEAD
CABINET,
SEE 12/A7
J J I
E
D
K
SCALE:
ENLARGED PLAN2
A1 1/4"=1'-0"
LINE OF AREA TO KEEP CLEAR FROM ELECTRICAL ITEMS-
PAINTED SAFETY YELLOW BY GENERAL CONTRACTOR.
REFER TO SHEET N1 FOR STRIPING CONDITIONS
ELECTRICAL PANELS FCAFB
E
D
1'-6"
CLR.7 5/8"℄1'-6"1'-7"℄A
C
B D3
A7AREA
UTILITY
111
7'-8 7/8"
8'-11 1/4"2 1/8"
5'
-
0
"
CLF2 ROOF
ACCESS
LADDER12'-8"9'-0 7/8"6"2'-2"
℄
REFER TO
SHEET N1
FOR
STRIPING
CONDITIONS
MS5
SIM.
MS2
F.E.
F.E.
F.E.5'-5"10
A6.1
3/4" THK. X 4'-0" H.
PLYWOOD BACKING
FOR MOUNTING
TELEPHONE/ ELECTRICAL
EQUIP.
WATER HEATER, SEE
PLUMBING
REFER TO
SHEET N1
FOR
STRIPING
CONDITIONS
4" DIA. STEEL
BOLLARD, TYP OF (3)
REFER 14/A6.1
2'-9 1/2"8 1/4"2'-0"1'-9"3'-3 1/8"
℄℄℄℄℄MS2
MS2
MS2
MS2
MS2
1'-4 5/8"
1'-6 3/4"
℄℄
WH
E6
A7
5'-0"
SCALE:
ENLARGED PLAN5
A1 1/4"=1'-0"
℄
MS6
4'-8"
1'-2"2'-3"1'-3"
℄
EYEWASH
STRIPING
REFER TO
SHEET N1
HANDSINK
SOAP
DISPENSER
PLYWOOD
CHAINLINK
FENCE
POST
2"2"
PLYWOOD
PA1FLOOR PLAN
AND NOTES