Loading...
HomeMy WebLinkAbout20 - Floor Plans1437 South Boulder, Suite 550 Tulsa, Oklahoma 74119.3609 p: 918.587.8600 f: 918.587.8601 www.sgadesigngroup.com 108TH AVE SE NEAR NE CARR RENTON, WA PROJECT CONTACTS:PHONE #: ARCHITECT: JEFF DALTON, AIA (918) 587-8600 SGA DESIGN GROUP, P.C. SHEET NUMBER:SHEET TITLE:NOTE: THIS DRAWING IS FOR CONCEPTUAL PURPOSES ONLY. SITE INFORMATION WAS OBTAINED FROM THE CLIENTS DOCUMENTS; DESIGN MAY VARY. 4. ALL MASONRY DIMENSIONS ARE NOMINAL DIMENSIONS, MASONRY CONTRACTOR TO ADJUST COURSING AS NEEDED. 1.WALL DIMENSIONS ARE TO FINISH CLEAR DIMENSION. ALL MATERIALS MUST BE FIGURED INTO THE LAYOUT OF THE FRAMING. 2. MASONRY OPENING SHALL BE COORDINATED WITH WINDOW OR DOOR MANUFACTURES REQUIREMENTS. 3. PLUMBING ROUGH INS ARE CRITICAL FOR ADA CLEARANCES, VERIFY ALL PLUMBING ROUGH INS PRIOR TO INSTALLING ROOM FINISHES. 5. PROPOSED FIRE EXTINGUISHERS ARE LOCATED BY THE SYMBOL F.E. COORDINATE TYPE, SIZE AND FINAL LOCATIONS WITH LOCAL FIRE OFFICIALS GENERAL NOTES 6. ALL GYP. BRD. WALLS THAT DO NOT EXTEND TO DECK SHALL BE BE BRACED IN (2) DIRECTIONS. CMU1 MS3 MS2 MS1 MS4 FRP 8" HIGH CONCRETE MASONRY UNIT OR 4" HIGH QUIK BRICK WITH HORIZONTAL REINFORCING AT 16" O.C. VERTICALLY. ALL DECORATIVE SURFACES SHOULD FACE TO EXTERIOR SIDE ONLY. REFER TO ELEVATIONS. 3 5/8" METAL STUDS AT 16" 0.C. WITH 5/8" GYPSUM BOARD BOTH SIDES. EXTEND PARTITION TO DECK (TYPICAL U.N.O.). USE MOISTURE RESISTANT GYPSUM BOARD ON INTERIOR SIDE OF TOILET AND MOP BASIN AREAS. 3 5/8" METAL STUDS AT 16" 0.C. WITH 5/8" GYPSUM BOARD BOTH SIDES WITH SOUND ATTENUATION BLANKETS BETWEEN. EXTEND PARTITION TO DECK (TYPICAL U.N.O.) USE MOISTURE RESISTANT GYPSUM BOARD ON INTERIOR SIDE OF TOILET AND MOP BASIN AREAS AND BEHIND DRINKING FOUNTAINS. 3 5/8" METAL STUDS AT 16" 0.C. WITH 1/2" PLYWOOD BOTH SIDES, PAINTED (TYPICAL UNLESS NOTED OTHERWISE). FRP BOARD GLUE EDGE TO EDGE OF SUBSTRATE. REFER TO INTERIOR ELEVATIONS ON SHEET A7 FOR HEIGHTS A.F.F. NOTES: 1. SOME WALL TYPES MAY NOT BE USED. REFER TO PLANS 2. REFER TO STRUCTURAL DRAWINGS FOR STUD GAUGES AND ADDITIONAL FRAMING INFORMATION. MS5 6" METAL STUDS AT 16" 0.C. WITH 5/8" GYPSUM BOARD BOTH SIDES WITH SOUND ATTENUATION BLANKETS BETWEEN. EXTEND PARTITION TO DECK (TYPICAL U.N.O.) AT SIM. CONDITION, EXTEND PARTITION 4" MIN. ABOVE CEILING. USE MOISTURE RESISTANT GYPSUM BOARD ON INTERIOR SIDE OF TOILET AND MOP BASIN AREAS. 1 1/2" "Z" FURRING AT 24" O.C. (ON MASONRY WALL) WITH 5/8" GYPSUM BOARD. EXTEND 1 1/2" RIGID INSULATION TO DECK ABOVE. (TYPICAL U.N.O.) USE MOISTURE RESISTANT GYPSUM BOARD IN TOILET AND MOP SINK AREAS AND 6" METAL STUDS @16" O.C. IN PLUMBING WALLS. STANDARD WALL TYPES CLF1 2 1/2" Ø GALV. STEEL POSTS AT 4' O.C. WITH 2" GALV. CHAINLINK FABRIC. AT SIM. CONDITION; 4' X 8' SHEETS OF 3/4" EXTERIOR GRADE PLYWOOD TO 12'-0" AFF ON INVENTORY SIDE MS6 6" METAL STUDS AT 16" 0.C. WITH 1/2" PLYWOOD BOTH SIDES, PAINTED. CLF2 2 1/2" Ø GALV. STEEL POSTS AT 4' O.C. WITH 2" GALV. CHAINLINK FABRIC STARTS AT 12'-8" AF.F. ON INVENTORY SIDE AND 4' X 8' SHEETS OF 3/4" EXTERIOR GRADE PLYWOOD TO 12'-8 1/2" AFF ON SERVICE BAY SIDE MS7 6" METAL STUDS AT 16" 0.C. WITH 5/8" GYPSUM BOARD BOTH SIDES, PAINTED. CMU2 8" CONCRETE MASONRY UNIT WITH HORIZONTAL REINFORCING AT 16" O.C. VERTICALLY. SMOOTH FACES ON BOTH SIDES (NO INSULATION IN INTERIOR WALLS) MS8 3 5/8" METAL STUDS AT 16" 0.C. WITH 5/8" GYPSUM BOARD BOTH SIDES, 3/4" PLYWOOD ATTACHED TO STUDS ON SHOP SIDE ONLY. MARK DESCRIPTION SANITARY NAPKIN DISPOSAL UNIT PAPER TOWEL DISPENSER & DISPOSAL MIRROR - SEE ELEVATIONS FOR SIZE TOILET TISSUE DISPENSER 36" GRAB BAR WITH WOOD BACKER 42" GRAB BAR WITH WOOD BACKER, WITH 18" VERTICAL BAR AS REQUIRED.A B C D E F G H COAT HOOK HANDICAP SIGN-MOUNT 5'-0" AFF TO CENTER: 8" EDGE TO JAMB EDGE. I BABY CHANGING STATION. SEE DETAIL 1/N1 J 6 HALF LOCKER UNIT QTY(2)-(SECURE TO WALL) NOTES 1. PROVIDE WOOD BLOCKING AS REQUIRED FOR MOUNTING ACCESSORIES 2. ACCESSORY PACKAGE AVAILABLE FROM NATIONAL VENDOR. 3. REFER TO SHEET N1 FOR MOUNTING HEIGHTS, LOCATIONS, ETC OR TOILET ROOM ACCESSORIES. K WRITING SURFACE, SEE DETAIL 11/A7 ACCESSORIES 2 A1 ENLARGED PLAN NORTH 154'-0" OVERALL 5'-0"121'-1 1/4"32'-10 3/4"10'-0"50'-0"OVERALL31'-4 1/2"12'-4 1/2"8'-8"R.O.4'-4"6'-0"R.O.40'-7 3/4" 4'-0"10'-0" M.O. 2'-0"3'-4" M.O. 3'-9 1/4"10'-0" M.O. 3'-4"10'-0" M.O. 3'-4"10'-0" M.O. 3'-4"10'-0" M.O. 3'-4"10'-0" M.O. 3'-4"10'-0" M.O. 3'-4"10'-0" M.O. 3'-4"2'-0"31'-8"4'-4"M.O.5'-8"4'-4"M.O.4'-0"5'-0"5'-0"31'-8"9'-2"(3) EQ. SP.10 DOWNSPOUT TYP. SEE ROOF PLAN FOR LOCATIONS 12'-2 3/4" STEP DOWN FROM FINISH FLOOR TYPICAL AT ALL OVERHEAD DOOR - SEE STRUCTURAL DRAWINGS 1"x12" WOOD FORM, TYP. ELECTRICAL SERVICE - SEE ELECTRICAL BAYS SERVICE 108 INVENTORY 109INVENTORY USED 110 09 26CLF2 SEE GRADING PLAN FORDEGREE OF SLOPE AT APRONT.O. CONC. APRONEL: 99'-9" TYP. AT EDGET.O. CONC. APRONEL: 99'-10 1/2" TYP. AT EDGEKNOX BOX & ALARM STROBE LOCATED PER FIRE DEPT. IF REQUIRED 11 A4 8 A6 6 A4 1 A4 10 A6 TYP @ OH DOORS 14 A6 TYP @ SERVICE DOORS 7 A6 1 A5 SHOWROOM CUSTOMER 100 18 A6 TYP @ OH DOOR JAMBS 16 A4 8 A6 9 A6 SIM. 16 A6 BACKFLOW AND DOMESTIC WATER SERVICE. SEE PLUMBING SHEETS AREA OF FIRE SPRINKLER SERVICE AND BOLLARDS T.O. CONCRETEEL: 100'-0" TYP @ PERIMETERCMU1 MS3 MS3 20 17 16 15 14 13 12 11 21 01 02 03 04 06 25 16'-8" M.O. 6 A5 10 A5 5 A5 15 A5 10'-0"APRON CONTROL JOINTS ARE TO BE LOCATED ON THE CENTER OF EACH PILASTER. (TYP.) KEY DROP BOX REFER. 16/A7 CMU1 1'-0" 1'-8"50'-0"OVERALL154'-0" OVERALL 12 A6 F.E. F.E.F.E. F.E. 2918'-4"CMU1 4'-8 1/2"1'-4" 4'-0" LINE OF CANOPY ABOVE REFER 10/A4 A B C D 15 A6 PROVIDE SIGN AT TOX ALERT SWITCH, REFER E2. (RED SIGN/ WHITE LETTERS) STATING "TURN EXHAUST FAN ON ANYTIME GAS CADDY IS IN USE" 13456789101112 B A M 2 WH SCALE: FLOOR PLAN16 A1 1/8"=1'-0" 07 1'-3 1/2"44'-6"4'-8" 1'-10 3/4" 4'-0"48'-1 1/4"4'-0" 27'-6" (7) EQUAL SPACES CLF1 11 A6 20 A7 8 A6.1 8 A6.1 9 A6.1 8 A6.1 CLF2 MS2 6 A6.1 E E 22 3'-4" M.O. 3'-4" E 113'-4 1/4" CLF2 4'-0"16'-8"M.O.ALIGNMENT RACK RECESSED SLAB OUTLINE AND FLOOR DRAIN SEE STRUCT. AND PLBG. NOTE: PAINT PERIMETER STEEL YELLOW TYPICAL 7 A6 SIM. 6" 44'-0" (11) EQUAL SPACES 3'-0 3/4" 1'-0 1/2"11 1/4" 9 1/2" 5 A1 3'-0" TYP.7'-0"62'-4 3/4"3'-0"8'-4 1/4"3'-0"24'-1"8'-6 5/8"6'-2"8'-1" 11 1/4"5'-10"45.0°45.0°11'-5"℄CLF1 20 A7 SIM. SIM. F 10'-8"M.O.8'-0"M.O.5'-0" LINE OF CANOPY ABOVE REFER 10/A4 LINE OF ROOF ABOVE LINE OF AWNING ABOVE LINE OF AWNING ABOVE GAS SERVICE. SEE PLUMBING SHEETS LINE OF AWNING ABOVE1'-7"5'-1 7/8" CLR. 1'-6" CLR.7'-6 1/4"2 1/8"4 7/8"18'-8 7/8"7 1/2"7'-2"ALL LOCATIONS AND DIMENSIONS ARE CRITICAL IN THIS PLAN. ADA CLEARANCES ARE TO BE VERIFIED PRIOR TO SETTING FINISHES. SHELVES ABOVE TOILET UNISEX 103 SHOWROOM CUSTOMER 100 OFFICE 102 AREA CLEAN UP 104 AREA BREAK 105 AREA CHANGING 106 ℄℄A C B D1 A7 TOILET SHOP 107 A C B D4 A7 G CMU1 A C B D6 A7 MS2 1'-6"SHELF & ROD C 3"3'-5 1/2"6'-1 3/4"MS3 MS5 7'-1 7/8" CLR. 2 1/8"7 5/8" H 4'-0"15'-11 1/2" A CLOSET 'IT' 101 MS2 PHONE BOARD 5' - 0 " 2'-9 3/8" 2 1/8" SHELVING IT-ELEV. REFER 10/A7OVERHEAD CABINET, SEE 12/A7 J J I E D K SCALE: ENLARGED PLAN2 A1 1/4"=1'-0" LINE OF AREA TO KEEP CLEAR FROM ELECTRICAL ITEMS- PAINTED SAFETY YELLOW BY GENERAL CONTRACTOR. REFER TO SHEET N1 FOR STRIPING CONDITIONS ELECTRICAL PANELS FCAFB E D 1'-6" CLR.7 5/8"℄1'-6"1'-7"℄A C B D3 A7AREA UTILITY 111 7'-8 7/8" 8'-11 1/4"2 1/8" 5' - 0 " CLF2 ROOF ACCESS LADDER12'-8"9'-0 7/8"6"2'-2" ℄ REFER TO SHEET N1 FOR STRIPING CONDITIONS MS5 SIM. MS2 F.E. F.E. F.E.5'-5"10 A6.1 3/4" THK. X 4'-0" H. PLYWOOD BACKING FOR MOUNTING TELEPHONE/ ELECTRICAL EQUIP. WATER HEATER, SEE PLUMBING REFER TO SHEET N1 FOR STRIPING CONDITIONS 4" DIA. STEEL BOLLARD, TYP OF (3) REFER 14/A6.1 2'-9 1/2"8 1/4"2'-0"1'-9"3'-3 1/8" ℄℄℄℄℄MS2 MS2 MS2 MS2 MS2 1'-4 5/8" 1'-6 3/4" ℄℄ WH E6 A7 5'-0" SCALE: ENLARGED PLAN5 A1 1/4"=1'-0" ℄ MS6 4'-8" 1'-2"2'-3"1'-3" ℄ EYEWASH STRIPING REFER TO SHEET N1 HANDSINK SOAP DISPENSER PLYWOOD CHAINLINK FENCE POST 2"2" PLYWOOD PA1FLOOR PLAN AND NOTES