Loading...
HomeMy WebLinkAbout30a - Geotechnical Report (PSI) GEOTECHNICAL ENGINEERING REPORT Firestone Retail Store 17808 108th Ave SE Renton, WA 98055 PSI PROJECT NO.07121375 June 1, 2016 Prepared for: Bridgestone Retail Operations, LLC 333 E. Lake Street Bloomingdale, IL 60108 Prepared by: Professional Service Industries, Inc. 20508 - 56th Ave W, Suite A Lynnwood, WA 98036 Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 Page 1 of 7 1. PROJECT DESCRIPTION PSI understands the site improvements will consist of a new single story retail facility and expanded parking. Based on preliminary structural information provided and previous experience with similar projects, we anticipate column and wall loads be on the order of 30 kips and 3 kips per foot, respectively. We also anticipate design floor loads of about 125 psf with a maximum concentrated load of 8 kips. 2. SITE DESCRIPTION 2.1. General The proposed site is located at 17808 108th Ave SE in Renton, Washington. Based on readily available aerial images the site presently has a single story building, which we understand will be razed prior to construction. The remainder of the site has sporadic landscaped shrubbery and paved parking. The site is bordered to the west by 108th Ave SE (State Route 515), to the east by 109th Ave SE, and to the north and south by existing developments. 2.2. Topography Our review of available topographic information indicates that the proposed site is relatively flat with elevations ranging from approximately EL400 to EL410 from east to west over a distance of approximately 300 feet, based on available aerial imagery on Google Earth. 2.3. Geology Based on a review of the geology of the region utilizing the Washington Department of Natural Recourses Interactive Geologic Map (WDNRIGM), PSI observed that this area is mapped as Quaternary glacial till. Glacial till is typically silts sand and gravels that have been overridden by a glacier and are thereby heavily over-consolidated. 2.4. Seismic Design Values The nearest mapped fault zone to the site is the Seattle Fault Zone approximately 5 miles northwest of the site. The Seattle Fault Zone is mapped as a Holocene age thrust faults that trend east to west with a reported slip rate of 0.2 to 1 mm per year (Reference 2). The contribution of potential earthquake-induced ground motion from known sources is included in the probabilistic ground motion maps published by the USGS. Design data regarding seismic site characterization and design recommendations based on USGS mapping and analysis are implemented in the 2012 International Building Code. Based on the SPT data collected during our drilling, the site conforms to the characteristics of Site Class C. The published design ground motion values, based on the USGS Seismic Design Maps (Reference 3), corresponding to a risk-targeted 2 percent probability of exceedance in 50 years at the project site. Seismic design values for the project site are provided in Table 1 below. Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 Page 2 of 7 Table 1: Ground Motion Values* Period (sec) Mapped MCE Spectral Response Acceleration (g) Site Coefficients Adjusted MCE Spectral Response Acceleration (g) Design Spectral Response Acceleration (g) 0.2 Ss 1.395 Fa 1.000 SMs 1.392 SDs 0.928 1.0 S1 0.519 Fv 1.300 SM1 0.674 SD1 0.450 *Risk Targeted 2% Probability of Exceedance in 50 years for Latitude 47.44309 and Longitude -122.19636 2.5. Subsurface conditions Subsurface materials and conditions were investigated with nine hollow-stem auger borings performed on May 16th, 2016. The nine borings were drilled to a depth of approximately 11 to 21 feet below the ground surface. The approximate locations of the soil borings are shown on Figure 2. In general, the soils under the proposed building areas generally consist of loose to medium dense silty sands fill soils over medium dense to very dense glacial till soils. A description of our field investigation, and our boring logs, are available in Appendix A. A description of the laboratory testing program along with sample test results are available in Appendix B. The terms used to describe material encountered in the boring are defined in the General Notes. A description of the soils as they were encountered from the ground surface is provided below. 1. FILL: The fill generally consisted of silty sands. The fill was observed in all borings. N-Values in the silty sand fill soils ranged from 3 to 25 blows per foot to indicate relative densities of loose to medium dense. Moisture contents of the fill soils range from 15 percent to 20 percent. 2. WEATHERED TILL: The weathered till deposits consisted of light brown to dark brown with orange mottling, silty sand and silt with sand soils. Weathered till was observed in all borings. N-Values ranged from 22 to 72 blows per foot in the silty sand soils to indicate relative densities of medium dense to very dense. Moisture contents in the silty sand soils range from 13 percent to 18 percent. 3. TILL: The till deposits consisted of gray silty sand soils and were observed in all borings except B-1 and B-2. N-Values ranged from 50 blows for 2 inches to 50 blows for 6 inches to indicate a relative density of very dense. Moisture contents of the till range from 9 percent to 20 percent. 2.6. Groundwater Static groundwater was not encountered at the boring locations at the time of our field investigation; however, PSI believes that small amounts of perched water was observed in borings B-3 and B-4. This perched water was observed within sand lenses within the till soils and may be present in other portions of the site seasonally or after significant precipitation events. 3. CONCLUSIONS AND RECOMMENDATIONS 3.1. General Subsurface explorations for this investigation indicate the presence of as much as 3½ to 5½ feet of fill overlying glacially consolidated soils across the entire site. It is PSI’s opinion that the onsite soils are suitable to support conventional spread footings provided the recommendations stated below are followed. Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 Page 3 of 7 3.2. Site Preparation We anticipate that the removal of existing structures, foundations and utilities will likely disturb the upper 3½ to 5½ feet of soils in the northern portion of the site. Any large debris encountered below proposed new buildings should be removed. 3.3. Structural Fill All fill placed beneath foundation elements, sidewalk, and pavement areas should be placed as compacted structural fill. We recommend that structural fill extends at least 2 feet beyond building and pavement limits where nearby structures do not restrict fill placement. On-site soils, in lieu of organic matters or other deleterious materials can be reused for backfill purposes, provided the material can obtain moisture contents that will allow it to meet compaction requirements. Imported material, if required, should be approved by the geotechnical engineer. Compacted fill should be placed in 12-inch-thick lifts (loose) by heavy compactors such as large vibratory rollers and hoe-packs and in 6 inch loose lists for smaller compactors such as small plate compactors and jumping jacks. These soil should be moisture-conditioned to within 2 percent of the optimum moisture content, and compacted to a density of 95% of the maximum dry density as determined by ASTM D 1557. The condition of the subgrade should be evaluated by a PSI representative before fill placement or construction begins. Fill compaction should be evaluated by in-place density tests performed during fill placement so that adequacy of soil compaction efforts may be evaluated as earthwork progresses. When fill material is inconsistent or when more than 30% of the fill material is retained on a ¾ inch sieve, fill placement should be observed and compaction evaluated by observation of a proof-roll using a loaded tandem axle dump truck. If Imported fill materials area required PSI recommends they consist of granular material such as pit-run or quarry-run rock, crushed rock, crushed gravel, or sand. They should be fairly well-graded between coarse and fine material with a maximum particle size of 2 inches and should have less than 5 percent by weight passing the U.S. Standard No. 200 Sieve. 3.4. Utility Trench Excavations and Backfill Excavations should be made in accordance with applicable Federal and State Occupational Safety and Health Administration regulations. Utility trenches in the near surface sand soils at the site will need to be sloped, or shored from the ground surface due to the potential for caving. Actual inclinations will ultimately depend on the soil conditions encountered during earthwork. While we may provide certain approaches for trench excavations, the contractor should be responsible for selecting the excavation technique, monitoring the trench excavations for safety, and providing shoring, as required, to protect personnel and adjacent improvements. The information provided below is for use by the owner and engineer and should not be interpreted to mean that PSI is assuming responsibility for the contractor’s actions or site safety. The fill and soft silty soils PSI encountered onsite should be considered Type C soils. Dense or hard native soils can be classified as Type B soil according to the most recent OSHA regulations. In our opinion, excavations should be safely sloped or shored. The contractor should be aware that excavation and shoring should conform to the requirements specified in the applicable local, state, and federal safety regulations, such as OSHA Health and Safety Standards for Excavations, 29 CFR Part 1926, or successor regulations. We understand that such regulations are being strictly enforced, and if not followed, the contractor may be liable for substantial penalties. Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 Page 4 of 7 Excavation and construction operations may expose the on-site soils to inclement weather conditions. The stability of exposed soils may deteriorate due to a change in moisture content or the action of heavy or repeated construction traffic. Accordingly, foundation and pavement area excavations should be protected from the elements and from the action of repetitive or heavy construction loadings. Utilities trenches within the building, pavement, and sidewalk areas should be backfilled with structural fill and compacted in accordance with the recommendation in section 3.3 of this report with the exception of fill soils placed immediately around and above the first foot vertically around utility lines which should be compacted to at least 90% of the maximum dry density as determined by ASTM D 1557. Compaction by jetting or flooding should not be permitted. 3.5. Foundations PSI has provided two options for the potential foundation subgrade preparation which are listed below. Option 1: Footing subgrades should be over-excavated a minimum of two feet and have the soil in the base of the trenches compacted to a firm and unyielding state as determined by the geotechnical engineer, then the removed soil should either be recompacted as structural fill back into the over-excavated area or should replaced with imported structural fill, place in accordance with the recommendations in Section 3.3 of this report. The over-excavation and backfill areas should extend at least 2 feet beyond the edge of the footings or a distance equivalent to the depth of the over-excavation, whichever is greater. Provided these foundation subgrades are prepared in this way the building may be supported by shallow spread footings with an allowable bearing pressure of up to 3,000 pounds per square foot (psf). This value applies to the total of dead load and/or frequently applied live load and can be increased by one-third for the total of all loads; dead, live and wind or seismic. Option 2: Footing may be excavated extending to dense native glacial till soils that were observed from 3½ to 5½ feet below existing site grades. Footings extending down to these dense native soils may be designed with an allowable bearing capacity of 5,000 psf. This value applies to the total of dead load and/or frequently applied live load and can be increased by one-third for the total of all loads; dead, live and wind or seismic. Regardless of the option selected All footings should have a minimum 18 inches of embedment below the lowest adjacent final grade for frost protection and all footing subgrades should be prepared in the same manner across the site. Perimeter and spread footing should be at least 18 inches and 24 inches wide respectively. Horizontal forces can be resisted partially or completely by frictional forces developed between the base of the spread footings. The total shearing resistance between the foundation footprint and the soil should be taken as the normal force, i.e., the sum of all vertical forces (dead load plus real live load) times the coefficient of friction between the soil and the base of the footing. We recommend assuming an ultimate coefficient of friction value of 0.30 for design. If additional lateral resistance is required, passive earth pressures against embedded footings or walls can be computed using a pressure based on an equivalent fluid with a unit weight of 250 pounds per cubic foot. This value assumes that backfill around footings will be placed as granular structural fill. Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 Page 5 of 7 3.6. Settlement The building foundation loads, and floor live loads will all cause settlement due to consolidation, or compression, of the underlying soils. The subsurface information and laboratory test data developed for this study was used to estimate settlement beneath these loads. We have assumed that the maximum wall and column loads will be 3 kips per foot and 30 kips for the purpose of this analyses on both foundation options. We estimate that the settlement of a typically loaded, isolated column footing designed in accordance with our previously recommended allowable bearing pressure of 5,000 psf on dense native soil will be less than 1 inch, additionally we estimate that settlement for 3,000 psf footings, founded on 2 feet of structural fill, will be less than 1 inch. These estimates assume that the load on the footings are real dead load and sustained or long- term live load. Lesser actual bearing pressures will produce less settlement. Some differential settlement between footings should be expected due to differences in their size and loading conditions and the variability in subsurface conditions across the building footprint. Differential settlements are difficult to quantify; however, we anticipate they will likely be limited to less than about one half of the total settlement or less than ½ inch for both foundation options along a 40-foot span. Settlement of the footings is also expected to occur rapidly, essentially as the new structural loads are placed and shortly thereafter. Footing settlements will be in addition to areal settlements due to floor live, or storage loads. For this reason, we recommend that floors, walls and columns be designed to move independently of each other. 3.7. Floor Support PSI recommends that soil subgrades below the slab be compacted to a firm and unyielding state. Compaction of in these areas should be confirmed with a proof rolled with a loaded tandem axel dump truck, or be observed by the geotechnical engineer or their representative to be firm and unyielding. We further recommend the installation of a 6-inch thick granular base course beneath the floor slab to provide uniform support and a capillary break between the slab and the subgrade soil. The base course should consist of crushed rock with particles no larger than 1-inch size and having less than about 2% passing the No. 200 sieve (washed analysis). Crushed rock ¾ to ¼ inch gradation is often used for this purpose. The base course material should be installed in a single lift and compacted to at least 95% of the maximum density as determined by ASTM D 1557 or to a firm and unyielding state. In our opinion, it is appropriate to assume a coefficient of subgrade reaction, k, of 250 pound per cubic inch for the design of floor slabs constructed as recommended above. It may also be appropriate to install a vapor-retarding membrane beneath slabs that will receive floor coverings or will be used to store moisture-sensitive materials. The membrane should be installed in accordance with manufacturer's recommendations. 3.8. Drainage We recommend footing drains be placed around the exterior of the building foundation to reduce the potential for lateral migration of moisture into the building envelope. We recommend that all roof drains be connected to a tight-line pipe leading to storm drain facilities. Pavement surfaces and open space areas should be sloped such that surface water runoff is collected and routed to suitable discharge points. We also recommend that ground surfaces adjacent to buildings be sloped to facilitate positive drainage away from the buildings. 3.9. Pavement For automobile parking areas founded on silty sand fill soil, we recommend a pavement section consisting of 2½ inches of asphaltic concrete (AC) over 4 inches of crushed rock base (CRB) or 4 inches of Portland Cement Concrete (PCC) over 4 inches of crushed rock base. If semi-trucks, or other heavy equipment is Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 Page 6 of 7 expected on paved areas, the pavement section should consist of 4 inches of AC over 6 inches of CRB or 5 inches of PCC over 6 inches of CRB. These preliminary pavement sections are based on a pavement design using the site sand subgrade, a desired pavement life of 20 years, and a terminal serviceability index of 2.0. These estimates should be revised once design traffic information is developed. These recommended pavement sections are also based on the assumption that the subgrade consists of firm, undisturbed soil or structural fill and that the pavement will be constructed during the dry summer months. Proofrolling should be used to evaluate pavement subgrade. Any soft areas disclosed by proofrolling will likely require over-excavation and replacement with structural fill. Some contingency should be provided for the repair of any soft areas. Permanent, properly installed drainage is also an essential aspect of pavement design and construction. All paved areas should have positive drainage to prevent ponding of surface water and saturation of the base course. This is particularly important in cut sections or at low points within the paved areas, such as in sunken loading dock areas or around stormwater catch basins. Effective means to prevent saturation of the base course including installing subdrain systems below sunken loading docks and weep holes in the sidewalls to catch basins. 3.10. Stormwater Based on previous experience on glacial till sites PSI does not believe that infiltration of site stormwater will be practical. Glacial till soil in this region typically provide infiltration rates of less than one inch per hour and very often less than ¼ inch per hour. 4. DESIGN REVIEW AND CONSTRUCTION MONITORING We welcome the opportunity to review and discuss construction plans and specifications as they are being developed. We are of the opinion that to observe compliance with the design concepts, specifications, and recommendations, construction operations dealing with earthwork and foundations should be observed by a qualified geotechnical engineer. We would be pleased to provide these services to you. 5. REPORT LIMITATIONS The recommendations submitted in this report are based on the subsurface information obtained by PSI and design details furnished by representatives of the client, Bridgestone Retail Operations LLC., for the proposed improvements at 17808 108th Avenue SE in Renton, Washington. If there are any revisions to the plans for this project, or if deviations from the subsurface conditions noted in this report are encountered during construction, PSI should be notified immediately to determine if changes in the foundation and/or pavement recommendations are required. If PSI is not retained to review these changes, PSI will not be responsible for the impact of those conditions on the project. After the plans and specifications are more complete, PSI should be retained and provided the opportunity to review the final design plans and specifications to verify that our engineering recommendations have been properly incorporated into the design. Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 Page 7 of 7 REFERENCES Reference 1: Washington Department of Natural Recourses Interactive Geologic Map, http://www.dnr.wa.gov/researchscience/topics/geosciencesdata/pages/geology_portal.aspx Reference 2: U.S. Geological Survey, 2010, Quaternary fault and fold database for the United States, accessed November 10, 2010, from USGS web site: http://earthquake.usgs.gov/hazards/qfaults/. Reference 3: USGS Seismic Design Maps. http://earthquake.usgs.gov/designmaps/us/application.php Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 FIGURES VICINITY MAP SITE EXPLORATION LOCATION MAP Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 APPENDIX A FIELD EXPLORATION PROGRAM GENERAL NOTES SOIL CLASSIFICATION CHART BORING LOGS Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 FIELD EXPLORATION PROGRAM General We explored the site by drilling nine soil borings (B-1 to B-9) to depths that ranged from approximately 11 feet to 21 feet below existing ground surface on May 16, 2016, using a trailer- mounted mobile drill rig. The locations of the borings are shown on Figure 2. A representative of PSI’s geotechnical staff was present during the explorations to record soil and groundwater conditions encountered in the exploration and to obtain soil and rock samples for laboratory testing. Sampling Procedures Throughout the drilling operation, soil samples were obtained from the borings using a 2-inch OD Split Spoon in general conformance with guidelines presented in ASTM D1586, Standard Test Method for Penetration Test and Split Barrel Sampling of Soils. The samplers were driven into the soil a distance of 18 inches or to refusal with a 140-pound hammer free falling a distance of 30 inches. The sum of the blows required to drive the sampler in three 6-inch increments is provided in the boring logs. If the sampler met refusal, the number of inches driven and the number of blows is recorded. The borings were drilled to observe the stratigraphy, density, and variability of subsurface soil conditions. Soil samples recovered from the explorations were sealed in airtight plastic bags to retain moisture and carefully transported to PSI’s laboratory for additional examination and testing. Field Classification Soil samples were initially classified visually in the field. Consistency, color, relative moisture, degree of plasticity, peculiar odors and other distinguishing characteristics of the soil samples were noted. The terminology used in the soil and rock classifications and other modifiers are defined in the General Notes in this appendix. Exploration Logs Summary boring logs follows in this appendix. The left-hand portion of the boring log gives our interpretation of the soil encountered in the soil boring, sample locations and depths, and groundwater information. The right-hand portion of the log shows the results of the sample water contents, and other laboratory information. The soil profile shown on the boring logs represent the conditions only at actual exploration location. Variations may occur and should be expected. The stratifications represent the approximate boundary between subsurface materials; the actual transition may be gradual. Description Angular: Subangular: Subrounded: Rounded: RELATIVE DENSITY OF COARSE-GRAINED SOILS ANGULARITY OF COARSE-GRAINED PARTICLES SS: ST: BS: PM: CPT-U: Component Boulders: Cobbles: Coarse-Grained Gravel: Fine-Grained Gravel: Coarse-Grained Sand: Medium-Grained Sand: Fine-Grained Sand: Silt: Clay: Size Range Over 300 mm (>12 in.) 75 mm to 300 mm (3 in. to 12 in.) 19 mm to 75 mm (¾ in. to 3 in.) 4.75 mm to 19 mm (No.4 to ¾ in.) 2 mm to 4.75 mm (No.10 to No.4) 0.42 mm to 2 mm (No.40 to No.10) 0.075 mm to 0.42 mm (No. 200 to No.40) 0.005 mm to 0.075 mm <0.005 mm 0 - 4 4 - 10 10 - 30 30 - 50 50 - 80 80+ Criteria Particles with width/thickness ratio > 3 Particles with length/width ratio > 3 Particles meet criteria for both flat and elongated Relative Density Description Flat: Elongated: Flat & Elongated: SFA: HSA: M.R.: R.C.: H.A.: P.A.: SOIL PROPERTY SYMBOLS SAMPLE IDENTIFICATION GENERAL NOTES Descriptive Term Trace: With: Modifier: Standard "N" penetration: Blows per foot of a 140 pound hammer falling 30 inches on a 2-inch O.D. Split-Spoon. A "N" penetration value corrected to an equivalent 60% hammer energy transfer efficiency (ETR) Unconfined compressive strength, TSF Pocket penetrometer value, unconfined compressive strength, TSF Moisture/water content, % Liquid Limit, % Plastic Limit, % Plasticity Index = (LL-PL),% Dry unit weight, pcf Apparent groundwater level at time noted GRAIN-SIZE TERMINOLOGY Solid Flight Auger - typically 4" diameter flights, except where noted. Hollow Stem Auger - typically 3¼" or 4¼ I.D. openings, except where noted. Mud Rotary - Uses a rotary head with Bentonite or Polymer Slurry Diamond Bit Core Sampler Hand Auger Power Auger - Handheld motorized auger , , N: N60: Qu: Qp: w%: LL: PL: PI: DD: N - Blows/foot Criteria Particles have sharp edges and relatively plane sides with unpolished surfaces Particles are similar to angular description, but have rounded edges Particles have nearly plane sides, but have well-rounded corners and edges Particles have smoothly curved sides and no edges PARTICLE SHAPE The Unified Soil Classification System (USCS), AASHTO 1988 and ASTM designations D2487 and D-2488 are used to identify the encountered materials unless otherwise noted. Coarse-grained soils are defined as having more than 50% of their dry weight retained on a #200 sieve (0.075mm); they are described as: boulders, cobbles, gravel or sand. Fine-grained soils have less than 50% of their dry weight retained on a #200 sieve; they are defined as silts or clay depending on their Atterberg Limit attributes. Major constituents may be added as modifiers and minor constituents may be added according to the relative proportions based on grain size. Page 1 of 2 % Dry Weight < 5% 5% to 12% >12% RELATIVE PROPORTIONS OF FINES DRILLING AND SAMPLING SYMBOLS Split-Spoon - 1 3/8" I.D., 2" O.D., except where noted. Shelby Tube - 3" O.D., except where noted. Bulk Sample Pressuremeter Cone Penetrometer Testing with Pore-Pressure Readings Very Loose Loose Medium Dense Dense Very Dense Extremely Dense RELATIVE PROPORTIONS OF SAND AND GRAVEL STRUCTURE DESCRIPTION Description Stratified: Laminated: Fissured: Slickensided: Description Blocky: Lensed: Layer: Seam: Parting: CONSISTENCY OF FINE-GRAINED SOILS Page 2 of 2 MOISTURE CONDITION DESCRIPTION 0 - 0.25 0.25 - 0.50 0.50 - 1.00 1.00 - 2.00 2.00 - 4.00 4.00 - 8.00 8.00+ Extremely Soft Very Soft Soft Medium Hard Moderately Hard Hard Very Hard % Dry Weight < 15% 15% to 30% >30% SCALE OF RELATIVE ROCK HARDNESS Criteria Absence of moisture, dusty, dry to the touch Damp but no visible water Visible free water, usually soil is below water table 0 - 2 2 - 4 4 - 8 8 - 15 15 - 30 30 - 50 50+ Very Soft Soft Medium Stiff Stiff Very Stiff Hard Very Hard ConsistencyN - Blows/footQU - TSF GENERAL NOTES Descriptive Term Trace: With: Modifier: GRAIN-SIZED TERMINOLOGY (Typically Sedimentary Rock) Slightly Weathered: Weathered: Highly Weathered: DEGREE OF WEATHERING Rock Mass Description Excellent Good Fair Poor Very Poor Rock generally fresh, joints stained and discoloration extends into rock up to 25 mm (1 in), open joints may contain clay, core rings under hammer impact. Rock mass is decomposed 50% or less, significant portions of the rock show discoloration and weathering effects, cores cannot be broken by hand or scraped by knife. Rock mass is more than 50% decomposed, complete discoloration of rock fabric, core may be extremely broken and gives clunk sound when struck by hammer, may be shaved with a knife. Size Range >4.76 mm 2.0 mm - 4.76 mm 0.42 mm - 2.0 mm 0.075 mm - 0.42 mm <0.075 mm RQD Value 90 -100 75 - 90 50 - 75 25 -50 Less than 25 ROCK QUALITY DESCRIPTION Void Diameter <6 mm (<0.25 in) 6 mm to 50 mm (0.25 in to 2 in) 50 mm to 600 mm (2 in to 24 in) >600 mm (>24 in) QU - TSF ROCK VOIDS Criteria Cohesive soil that can be broken down into small angular lumps which resist further breakdown Inclusion of small pockets of different soils Inclusion greater than 3 inches thick (75 mm) Inclusion 1/8-inch to 3 inches (3 to 75 mm) thick extending through the sample Inclusion less than 1/8-inch (3 mm) thick Component Very Coarse Grained Coarse Grained Medium Grained Fine Grained Very Fine Grained (Continued) 2.5 - 10 10 - 50 50 - 250 250 - 525 525 - 1,050 1,050 - 2,600 >2,600 Description Very Thick Bedded Thick Bedded Medium Bedded Thin Bedded Very Thin Bedded Thickly Laminated Thinly Laminated Description Dry: Moist: Wet: Criteria Greater than 3-foot (>1.0 m) 1-foot to 3-foot (0.3 m to 1.0 m) 4-inch to 1-foot (0.1 m to 0.3 m) 1¼-inch to 4-inch (30 mm to 100 mm) ½-inch to 1¼-inch (10 mm to 30 mm) 1/8-inch to ½-inch (3 mm to 10 mm) 1/8-inch or less "paper thin" (<3 mm) Criteria Alternating layers of varying material or color with layers at least ¼-inch (6 mm) thick Alternating layers of varying material or color with layers less than ¼-inch (6 mm) thick Breaks along definite planes of fracture with little resistance to fracturing Fracture planes appear polished or glossy, sometimes striated Consistency ROCK BEDDING THICKNESSES Voids Pit Vug Cavity Cave SYMBOLS SW TYPICAL DESCRIPTIONS WELL-GRADED GRAVELS, GRAVEL - SAND MIXTURES, LITTLE OR NOFINES POORLY-GRADED GRAVELS,GRAVEL - SAND MIXTURES, LITTLEOR NO FINES SILTY GRAVELS, GRAVEL - SAND -SILT MIXTURES GRAPH SM MAJOR DIVISIONS SOIL CLASSIFICATION CHART PT GC GM GP GW LETTER COARSEGRAINED SOILS SP OH CH MH OL CL ML SC (APPRECIABLEAMOUNT OF FINES) ORGANIC CLAYS OF MEDIUM TOHIGH PLASTICITY, ORGANIC SILTS PEAT, HUMUS, SWAMP SOILS WITHHIGH ORGANIC CONTENTS CLEAN GRAVELS GRAVELS WITHFINES CLEAN SANDS (LITTLE OR NO FINES) SANDS WITH FINES LIQUID LIMITLESS THAN 50 LIQUID LIMIT GREATER THAN 50 HIGHLY ORGANIC SOILS (APPRECIABLE AMOUNT OF FINES) ORGANIC SILTS AND ORGANICSILTY CLAYS OF LOW PLASTICITY (LITTLE OR NO FINES) FINE GRAINED SOILS SAND AND SANDYSOILS SILTS AND CLAYS SILTS AND CLAYS MORE THAN 50%OF MATERIAL ISLARGER THAN NO. 200 SIEVESIZE MORE THAN 50% OF MATERIAL ISSMALLER THANNO. 200 SIEVE SIZE MORE THAN 50%OF COARSE FRACTIONPASSING ON NO.4 SIEVE MORE THAN 50%OF COARSE FRACTIONRETAINED ON NO.4 SIEVE NOTE: DUAL SYMBOLS ARE USED TO INDICATE BORDERLINE SOIL CLASSIFICATIONS GRAVEL ANDGRAVELLY SOILS INORGANIC CLAYS OF HIGH PLASTICITY INORGANIC SILTS, MICACEOUS ORDIATOMACEOUS FINE SAND ORSILTY SOILS CLAYEY GRAVELS, GRAVEL - SAND -CLAY MIXTURES WELL-GRADED SANDS, GRAVELLYSANDS, LITTLE OR NO FINES POORLY-GRADED SANDS, GRAVELLY SAND, LITTLE OR NOFINES SILTY SANDS, SAND - SILT MIXTURES CLAYEY SANDS, SAND - CLAY MIXTURES INORGANIC SILTS AND VERY FINE SANDS, ROCK FLOUR, SILTY ORCLAYEY FINE SANDS OR CLAYEYSILTS WITH SLIGHT PLASTICITY INORGANIC CLAYS OF LOW TO MEDIUM PLASTICITY, GRAVELLYCLAYS, SANDY CLAYS, SILTY CLAYS, LEAN CLAYS 1 2 3 4 12 3 18 18 2-2-4N=6 6-20-21 N=41 4-12-14N=26 11-11-11N=22 ASPHALT Silty SAND with Gravel Dark Brown,nonplastic, moist, loose, fine to medium sandwith concrete fragment & gravel. FILL Silty SAND with Gravel Light to Dark Brown,low placticity to nonplastic, moist, mediumdense to dense, fine to medium sand with gravel with some mottling. WEATHEREDGLACIAL TILL Bottom of boring at approximately 11 feet 6inches. No ground water observed SM SM 13 14 PROJECT NO.:07121375 PROJECT:Bridgestone RentonDepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)LATITUDE:47.44312° LONGITUDE:-122.19671° LOCATION:17808 108th Ave SEWaterREMARKS: DRILLER: Professional Service Industries, Inc. 20508 56th Avenue W, Suite A Lynnwood, WA 98036Telephone: (425) 409-2504 Renton, WASPT Blows per 6-inch (SS)SAMPLING METHOD: SS DATE STARTED:5/16/16 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Geologic Drill STATION:N/A OFFSET:N/A LOGGED BY:S.Malolo COMPLETION DEPTH 11.5 ft DRILL RIG:Trailer Mounted DRILLING METHOD:Hollow Stem Auger ELEVATION:N/A REVIEWED BY:MSP EFFICIENCY N/A HAMMER TYPE:Manual Pulley BORING LOCATION: 0 5 10 DATE COMPLETED:5/16/16 BORING B-1 1 2 3 4 18 5 18 18 2-2-1N=3 3-7-14 N=21 18-21-31N=52 18-21-16N=37 ASPHALT Silty SAND: dark brown, moist, lowplasticity, very loose. FILL Silty SAND: brownish gray to brown, moist,low plasticity, medium dense to very dense,fine to medium sand with gravel & trace mottling. WEATHERED GLACIAL TILL Bottom of boring at approximately 11 feet 6inches. No ground water observed. SM SM 22 16 13 15 PROJECT NO.:07121375 PROJECT:Bridgestone RentonDepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)LATITUDE:47.44324° LONGITUDE:-122.19663° LOCATION:17808 108th Ave SEWaterREMARKS: DRILLER: Professional Service Industries, Inc. 20508 56th Avenue W, Suite A Lynnwood, WA 98036Telephone: (425) 409-2504 Renton, WASPT Blows per 6-inch (SS)SAMPLING METHOD: SS DATE STARTED:5/16/16 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Geologic Drill STATION:N/A OFFSET:N/A LOGGED BY:S.Malolo COMPLETION DEPTH 11.5 ft DRILL RIG:Trailer Mounted DRILLING METHOD:Hollow Stem Auger ELEVATION:N/A REVIEWED BY:MSP EFFICIENCY N/A HAMMER TYPE:Manual Pulley BORING LOCATION: 0 5 10 DATE COMPLETED:5/16/16 BORING B-2 >> 1 2 3 4 5 6 18 18 18 12 5 5 3-5-9N=14 7-10-16 N=26 6-11-11N=22 31-50/6" 50/5" 50/5" ASPHALT Silty SAND: brown, moist, nonplastic,medium dense. FILL Silty SAND: brown, wet to moist (possibleperched water within sand lens), mediumdense, predominantly fine sand with trace of subround gravel. WEATHERED GLACIALTILL Silty SAND: brown to gray, moist, low plasticity, very dense, predominantly finesand and silt, 8 inch band of poorly graded SAND with silt observed from approximatley15 feet . GLACIAL TILL Bottom of boring at approximately 20 feet 5inches. Possible Perach groundwater at 6feet, but no static groundwater observed. SM SM SM 17 18 18 12 20 13 14 PROJECT NO.:07121375 PROJECT:Bridgestone RentonDepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)LATITUDE:47.44299° LONGITUDE:-122.19643° LOCATION:17808 108th Ave SEWaterREMARKS: DRILLER: Professional Service Industries, Inc. 20508 56th Avenue W, Suite A Lynnwood, WA 98036Telephone: (425) 409-2504 Renton, WASPT Blows per 6-inch (SS)SAMPLING METHOD: SS DATE STARTED:5/16/16 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Geologic Drill STATION:N/A OFFSET:N/A LOGGED BY:S.Malolo COMPLETION DEPTH 20.4 ft DRILL RIG:Trailer Mounted DRILLING METHOD:Hollow Stem Auger ELEVATION:N/A REVIEWED BY:MSP EFFICIENCY N/A HAMMER TYPE:Manual Pulley BORING LOCATION: 0 5 10 15 20 DATE COMPLETED:5/16/16 BORING B-3 >> >> >> 1 2 3 4 5 6 18 18 18 18 5 2 2-3-7N=10 11-15-17 N=32 8-15-17N=32 18-19-38N=57 50/5" 50/2" ASPHALT Silty SAND, brown, moist, nonplastic, mediumdense. FILL Silty SAND, brown with orange mottling, wetto moist (possible perched water within sand lenses), dense to very dense, predominantlyfine sand and silt with trace subround gravel.WEATHERED GLACIAL TILL Silty SAND, brown to gray, moist, low plastic to nonplastic, very dense, predominantly finesand with silt. GLACIAL TILL Bottom of boring at approximatley 20 feet 2 inches. Possible Perach groundwater at 6feet, but no static groundwater observed. SM SM SM 18 16 16 16 11 PROJECT NO.:07121375 PROJECT:Bridgestone RentonDepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)LATITUDE:47.44309° LONGITUDE:-122.19642° LOCATION:17808 108th Ave SEWaterREMARKS: DRILLER: Professional Service Industries, Inc. 20508 56th Avenue W, Suite A Lynnwood, WA 98036Telephone: (425) 409-2504 Renton, WASPT Blows per 6-inch (SS)SAMPLING METHOD: SS DATE STARTED:5/16/16 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Geologic Drill STATION:N/A OFFSET:N/A LOGGED BY:S.Malolo COMPLETION DEPTH 20.2 ft DRILL RIG:Trailer Mounted DRILLING METHOD:Hollow Stem Auger ELEVATION:N/A REVIEWED BY:MSP EFFICIENCY N/A HAMMER TYPE:Manual Pulley BORING LOCATION: 0 5 10 15 20 DATE COMPLETED:5/16/16 BORING B-4 >> >> >> 1 2 3 4 18 18 12 10 3-5-11N=16 13-15-21 N=36 15-50/6" 36-50/5" ASPHALT Silty SAND: brown, moist, nonplastic,medium dense. FILL Silty SAND: brown with orange mottling,moist, dense, predominantly fine sand withtrace of subround gravel. WEATHERED GLACIAL TILL Silty SAND: brown to gray, moist, lowplasticity, very dense, predominantly fine sand and silt. GLACIAL TILL Bottom of boring at approximately 10 feet 11 inches. No ground water observed. SM SM SM 15 14 12 10 PROJECT NO.:07121375 PROJECT:Bridgestone RentonDepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)LATITUDE:47.44325° LONGITUDE:-122.19633° LOCATION:17808 108th Ave SEWaterREMARKS: DRILLER: Professional Service Industries, Inc. 20508 56th Avenue W, Suite A Lynnwood, WA 98036Telephone: (425) 409-2504 Renton, WASPT Blows per 6-inch (SS)SAMPLING METHOD: SS DATE STARTED:5/16/16 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Geologic Drill STATION:N/A OFFSET:N/A LOGGED BY:S.Malolo COMPLETION DEPTH 10.9 ft DRILL RIG:Trailer Mounted DRILLING METHOD:Hollow Stem Auger ELEVATION:N/A REVIEWED BY:MSP EFFICIENCY N/A HAMMER TYPE:Manual Pulley BORING LOCATION: 0 5 10 DATE COMPLETED:5/16/16 BORING B-5 >> >> 1 2 3 4 5 6 18 18 18 12 9 11 6-11-15N=26 12-25-30 N=55 17-31-41N=72 29-50/6" 26-50/4" 35-50/5" ASPHALT Silty SAND: brown, moist, nonplastic,medium dense. FILL Silty SAND: brown with orange mottlingmoist, very dense, predominantly fine sand and silt with trace of subround gravel.WEATHERED GLACIAL TILL Silty SAND: brown to gray, moist,nonplastic, very dense, predominantly fine sand with silt, trace of gravel. GLACIAL TILL Bottom of boring at approximately 20 feet 11inches. No ground water observed. SM SM SM 15 13 16 12 9 10 PROJECT NO.:07121375 PROJECT:Bridgestone RentonDepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)LATITUDE:47.44308° LONGITUDE:-122.19615° LOCATION:17808 108th Ave SEWaterREMARKS: DRILLER: Professional Service Industries, Inc. 20508 56th Avenue W, Suite A Lynnwood, WA 98036Telephone: (425) 409-2504 Renton, WASPT Blows per 6-inch (SS)SAMPLING METHOD: SS DATE STARTED:5/16/16 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Geologic Drill STATION:N/A OFFSET:N/A LOGGED BY:S.Malolo COMPLETION DEPTH 20.9 ft DRILL RIG:Trailer Mounted DRILLING METHOD:Hollow Stem Auger ELEVATION:N/A REVIEWED BY:MSP EFFICIENCY N/A HAMMER TYPE:Manual Pulley BORING LOCATION: 0 5 10 15 20 DATE COMPLETED:5/16/16 BORING B-6 >> >> >> >> >> 1 2 3 4 5 6 18 18 12 12 6 11 13-7-8N=15 8-8-11 N=19 27-50/6" 18-50/6" 50/6" 30-50/6" ASPHALT Silty SAND: brown, moist, nonplastic,medium dense. FILL Silty SAND: brown with oranage mottling,moist, medium dense, predominantly finesand and silt with trace of subround gravel. WEATHERED GLACIAL TILL Silty SAND: brown to gray, moist,nonplastic, very dense, predominantly fine sand and silt with trace gravel. GLACIALTILL Bottom of boring at approximately 21 feet. Noground water observed. SM SM SM 15 12 16 12 11 10 13 PROJECT NO.:07121375 PROJECT:Bridgestone RentonDepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)LATITUDE:47.44308° LONGITUDE:-122.19596° LOCATION:17808 108th Ave SEWaterREMARKS: DRILLER: Professional Service Industries, Inc. 20508 56th Avenue W, Suite A Lynnwood, WA 98036Telephone: (425) 409-2504 Renton, WASPT Blows per 6-inch (SS)SAMPLING METHOD: SS DATE STARTED:5/16/16 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Geologic Drill STATION:N/A OFFSET:N/A LOGGED BY:S.Malolo COMPLETION DEPTH 21.0 ft DRILL RIG:Trailer Mounted DRILLING METHOD:Hollow Stem Auger ELEVATION:N/A REVIEWED BY:MSP EFFICIENCY N/A HAMMER TYPE:Manual Pulley BORING LOCATION: 0 5 10 15 20 DATE COMPLETED:5/16/16 BORING B-7 >> >> >> >> 1 2 3 4 5 6 7 8 1 9 14 10 9 10 7-15-10 N=25 8-9-11N=20 15-26-32 N=58 18-28-47N=75 15-28-50/3" N=78 41-50/3" 45/50/4" ASPHALT Poorly Graded GRAVEL with Silt and Sand:dark brown, moist, nonplastic, medium dense,predominantly subgrounded fine gravel with silt and sand matrix. FILL Silty SAND: brown, moist, nonplastic, medium dense. FILL Silty SAND: brown with orange mottling,moist, very dense, predominantly fine sand and silt with trace subround gravel.WEATHERED GLACIAL TILL Silty SAND: brown to gray, moist,nonplastic, very dense, predominantly fine sand with silt, trace of gravel. GLACIAL TILL Bottom of boring at approximately 20 feet 10 inches. No ground water observed. GP-GM SM SM SM 4 13 14 12 9 10 PROJECT NO.:07121375 PROJECT:Bridgestone RentonDepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)LATITUDE:47.44316° LONGITUDE:-122.19597° LOCATION:17808 108th Ave SEWaterREMARKS: DRILLER: Professional Service Industries, Inc. 20508 56th Avenue W, Suite A Lynnwood, WA 98036Telephone: (425) 409-2504 Renton, WASPT Blows per 6-inch (SS)SAMPLING METHOD: SS DATE STARTED:5/16/16 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Geologic Drill STATION:N/A OFFSET:N/A LOGGED BY:S.Malolo COMPLETION DEPTH 20.8 ft DRILL RIG:Trailer Mounted DRILLING METHOD:Hollow Stem Auger ELEVATION:N/A REVIEWED BY:MSP EFFICIENCY N/A HAMMER TYPE:Manual Pulley BORING LOCATION: 0 5 10 15 20 DATE COMPLETED:5/16/16 BORING B-8 >> >> >> >> >> 1 2 3 4 12 18 18 11 2-4-5N=9 6-12-14 N=26 12-21-38N=59 30-50/5" ASPHALT Silty SAND: brown, moist, nonplastic, loose.FILL Silty SAND bluish gray to brown, moist,medium dense to very dense, predominantlyfine sand and silt with trace of subround gravel. WEATHERED GLACIAL TILL Silty SAND: brown, moist, nonplastic, verydense, predominantly fine sand and silt, trace of gravel. GLACIAL TILL Bottom of boring at approximately 10 feet 11 inches. No ground water observed. SM SM SM 15 18 14 12 PROJECT NO.:07121375 PROJECT:Bridgestone RentonDepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)LATITUDE:47.44322° LONGITUDE:-122.19599° LOCATION:17808 108th Ave SEWaterREMARKS: DRILLER: Professional Service Industries, Inc. 20508 56th Avenue W, Suite A Lynnwood, WA 98036Telephone: (425) 409-2504 Renton, WASPT Blows per 6-inch (SS)SAMPLING METHOD: SS DATE STARTED:5/16/16 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Geologic Drill STATION:N/A OFFSET:N/A LOGGED BY:S.Malolo COMPLETION DEPTH 11.0 ft DRILL RIG:Trailer Mounted DRILLING METHOD:Hollow Stem Auger ELEVATION:N/A REVIEWED BY:MSP EFFICIENCY N/A HAMMER TYPE:Manual Pulley BORING LOCATION: 0 5 10 DATE COMPLETED:5/16/16 BORING B-9 >> >> Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 APPENDIX B LABORATORY TESTING PROGRAM LABORATORY TESTING RESULTS Firestone Retail Store Professional Service Industries, Inc. 17808 108th Ave SE, Renton, Washington Engineering ● Consulting ● Testing PSI Project No 07121375 June 1, 2016 Laboratory Testing Program and Procedures General Soil samples obtained during the field explorations were examined in our laboratory. The physical characteristics of the samples were noted and the field classifications were modified where necessary in accordance with terminology presented the General Notes included in this appendix. Representative samples were selected during the course of the examination for further testing. The testing procedures and results of the tests are summarized below. The phrase “In general accordance with guidelines presented in…” means that certain local and common descriptive practices and methodologies have been followed. Visual-Manual Classification The soil samples were classified in general accordance with guidelines presented in ASTM D2488, Standard Practice for Description and Identification of Soils (Visual-Manual Procedure). Certain terminology incorporating current local engineering practice, as provided in the Soil Classification Chart included with or in lieu of ASTM terminology. The term which best described the major portion of the sample was used in determining the soil type (that is, gravel, sand, silt or clay). Moisture Content Natural moisture content determinations were made on all samples. The natural moisture content is defined as the ratio of the weight of water to dry weight of soil, expressed as a percentage. The results of the moisture content determinations are presented on the boring logs in this appendix. Grain-Size Distribution Select samples from the borings were analyzed for grain size in general conformance with ASTM C 136 and ASTM C117. In general, samples were oven dried, weighed then washed over a #200 sieve to remove silt and clay sized particles and then dried again. The samples were separated through a series of sieves of progressively smaller openings for determination of particle size distribution. The material passing and/or retained on each sieve was recorded as a percent of the total sample weight. The results of the sieve analysis are depicted in this appendix. 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 0.0010.0100.1001.00010.000100.0001000.000PERCENT PASSING BY WEIGHTPARTICLE SIZE IN MILLIMETERS PARTICLE SIZE ANALYSIS -ASTM C136/C117 36"12"6"3"1 1/2"3/4"3/8"#4 #10 #20 #40 #60 #100 #200 Coarse Medium Fine Silt ClayFineCoarse COBBLES GRAVEL SAND FINE GRAINED SIZE OF OPENING IN INCHES U.S. STANDARD SIEVE SIZE HYDROMETER PROJECT NO:PROJECT NAME: Bridgestone Renton07121375 Exploration Sample Depth(feet)Moisture Reviewed USCS Symbol B-2 2.5 feet 21.9 MSP 2"1" BOULDERS 33.0% PL = - LL = - PI = -Silty SAND with Gravel SM Soil Classification % Gravel % Sand % Fines 45.1%21.9% 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 0.0010.0100.1001.00010.000100.0001000.000PERCENT PASSING BY WEIGHTPARTICLE SIZE IN MILLIMETERS PARTICLE SIZE ANALYSIS -ASTM C136/C117 36"12"6"3"1 1/2"3/4"3/8"#4 #10 #20 #40 #60 #100 #200 Coarse Medium Fine Silt ClayFineCoarse COBBLES GRAVEL SAND FINE GRAINED SIZE OF OPENING IN INCHES U.S. STANDARD SIEVE SIZE HYDROMETER PROJECT NO:PROJECT NAME: Bridgestone Renton07121375 Exploration Sample Depth(feet)Moisture Reviewed USCS Symbol B-3 15 feet 19.5 MSP 2"1" BOULDERS 11.1% PL = - LL = - PI = -Poorly Graded SAND with Silt SP-SM Soil Classification % Gravel % Sand % Fines 87.6%1.3% 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 0.0010.0100.1001.00010.000100.0001000.000PERCENT PASSING BY WEIGHTPARTICLE SIZE IN MILLIMETERS PARTICLE SIZE ANALYSIS -ASTM C136/C117 36"12"6"3"1 1/2"3/4"3/8"#4 #10 #20 #40 #60 #100 #200 Coarse Medium Fine Silt ClayFineCoarse COBBLES GRAVEL SAND FINE GRAINED SIZE OF OPENING IN INCHES U.S. STANDARD SIEVE SIZE HYDROMETER PROJECT NO:PROJECT NAME: Bridgestone Renton07121375 Exploration Sample Depth(feet)Moisture Reviewed USCS Symbol B-3 16 feet 12.6 MSP 2"1" BOULDERS 46.5% PL = - LL = - PI = -Silty SAND SM Soil Classification % Gravel % Sand % Fines 51.5%2.0% 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 0.0010.0100.1001.00010.000100.0001000.000PERCENT PASSING BY WEIGHTPARTICLE SIZE IN MILLIMETERS PARTICLE SIZE ANALYSIS -ASTM C136/C117 36"12"6"3"1 1/2"3/4"3/8"#4 #10 #20 #40 #60 #100 #200 Coarse Medium Fine Silt ClayFineCoarse COBBLES GRAVEL SAND FINE GRAINED SIZE OF OPENING IN INCHES U.S. STANDARD SIEVE SIZE HYDROMETER PROJECT NO:PROJECT NAME: Bridgestone Renton07121375 Exploration Sample Depth(feet)Moisture Reviewed USCS Symbol B-6 5 feet 13.0 MSP 2"1" BOULDERS 39.1% PL = - LL = - PI = -Silty SAND SM Soil Classification % Gravel % Sand % Fines 54.6%6.3% 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 0.0010.0100.1001.00010.000100.0001000.000PERCENT PASSING BY WEIGHTPARTICLE SIZE IN MILLIMETERS PARTICLE SIZE ANALYSIS -ASTM C136/C117 36"12"6"3"1 1/2"3/4"3/8"#4 #10 #20 #40 #60 #100 #200 Coarse Medium Fine Silt ClayFineCoarse COBBLES GRAVEL SAND FINE GRAINED SIZE OF OPENING IN INCHES U.S. STANDARD SIEVE SIZE HYDROMETER PROJECT NO:PROJECT NAME: Bridgestone Renton07121375 Exploration Sample Depth(feet)Moisture Reviewed USCS Symbol B-8 0 feet 4.3 MSP 2"1" BOULDERS 7.5% PL = - LL = - PI = -Poorly Graded GRAVEL with Silt and Sand GP-GM Soil Classification % Gravel % Sand % Fines 39.7%52.8%