Loading...
HomeMy WebLinkAboutVuecrest II On-Hold Letter with attachmentsawI,—.,_.,___ij . .——March3,2015Community&EconomicDevelopmentDepartmentC.E.”Chip”Vincent,AdministratorWaynePotterNovastarDevelopment,Inc.1821572r,dAveSKent,WA98032SUBJECT:“OnHold”NoticeVuecrestIIShortPlat,LUA15-000026,ECF,SHPL-A,MODDearMr.Potter:ThePlanningDivisionoftheCityofRentonacceptedtheabovemasterapplicationforreviewonJanuary26,2015.Duringourreview,staffhasdeterminedthatadditionalinformationisnecessaryinordertoproceedfurther.ThefollowinginformationwillneedtobesubmittedbeforeJune3,2015sothatwemaycontinuethereviewoftheabovesubjectapplication:•Thecross-sectionofRoadAhalf-streetimprovement(STA0+63toSTA2+50)mustberevisedasfollows:oGuardrail:Addaguardrail.SeeWSDOTstandardplanC-20.10-02fortheelevationviewwithacurbdetail.Specifically,thefaceofthebarriershouldbeflushwiththefaceofthecurb.Aminimum4-footwidedistanceisrequiredbetweentheguardrailandtheretainingwall.Youwillneedtomaintainthe22footcleartravellanewidthtothefaceofthebarrier.oChainlinkfence:Relocatethe4’tallblackvinylcoatedchainlinkfencebehindtheguardrail.oRetainingwall:Theapplicationindicatesthatthe“wallmaybearockery,MSEblock,Lock-Load,orareinforcedconcretewall.”Areinforcedconcretewallwillberequired.Utilitylinesinthestreetwouldbedisturbedbythegeosyntheticsoilreinforcementextendingintothepavementasrequiredforarockery,MSEblockorLock-Loadretainingwall.Pleaselabelthethicknessofthewallinthecross-section.Aretainingwallthatisfourfeet(4’)ortaller,asmeasuredbytheverticaldistancefromthebottomofthefootingtothefinishgradeatthetopofthewall(i.e.,notmeasuredbyexposedretainingwallheight),shallrequireabuildingpermit.Drainageprovisionswillalsoberequiredtobeprovidedfortheretainingwall.Astructuralengineerwillhavetoverifyifthe(2feetplus)cleatdistancebetweenthebackofwallandbackofguardrailpostisadequatetomaintainthestructuralintegrityofthewallshouldtheguardrailbehitbyamovingvehicle.oROWwidth:Pleaserevisetoright-of-way(ROW)widthto34feet,pendingthedistancerequiredbetweentheretainingwallandTractA.Ingeneral,theRentonCityHall•1055SouthGradyWay•Renton,Washington98057.rentonwa.gov minimumdistanceis3’betweenthebaseofthewallandtheabuttingparcelline.oSlope:Labeltheslopeoftheground(aftergrading)atthebackofsidewalk.oCriticalAreaTractA:BufferaveragingmaybeimpactedbytheincreaseinROWwidth.IfanyimpactsorchangesareproposedtoTractA,newplansand/orreportswillneedtoberesubmitted.•Thecross-sectionofRoadAhalf-streetimprovement(STA2+50toSTA7+50)mustberevisedasfollows:oParking:Parkingwillbelimitedtothesouthsideofthestreet.Supportofthemodificationisbeingconsideredprovidedanadditional0.5-footwideverticalcurbonthenorthsideofthestreetnearthepropertylineisaddedtothecross-section.ThiswillincludeaROWof40feet,unlessaretainingwallisrequiredatthenorthboundarylineoftheproposedhalfstreet.Theallowedslopeis4H:V.oSlope:Labeltheslopeoftheground(aftergrading)nearthepropertyboundaryedgeofRoadAfromtheentrancetoTractA.Guardrailand/orblackvinylcoatedchainlinkfencemaybeapplicablebasedontheslope.oRetainingwall:litheretainingwallisneeded,thereshouldbe2feetofseparationbetweenthefaceofthewallandthepavedroadsurfaceedge.ThiswouldrequireadditionalROWwidthfromthedevelopment.Aconstructioneasementandpermanentslopeeasementfromthenorthpropertyneighborwouldalsoberequitedatthetimeofutilityconstructionpermit.oStreetcenterline:ThecenterlineoftheRoadAfromSTA2+50toSTA7+50mustbeevenlysplitat13’(not18’and8’)witha2%crossslopeineachdirection.•TheROWdedicationof102ndAveSE(MainAveS)is4.5feet(subjecttofinalsurvey).Atthistime,yourprojectwillcontinuetobeplaced“onhold”pendingreceiptoftherequestedinformation.Pleasecontactmeat(425)430-7289ifyouhaveanyquestions.Sincerely,(JAJL/(%—___ClarkH.CloseAssociatePlannerWSDOTStandardPlanc-2o.lo-o2RoadA(STA0+63toSTA2+50)Redlinescc:DBSIII,LLD,KolinTaylor/Owner(s)MacKenzie;Rasmussen/Partyfies)ofRecordFileLUA15-000026,EcF,SHPL-A,MOD ,RAIL ELEMENT ,‘6vI2BLOCKOUT --/(SEE NOTE 4) —/ /6 9 TIMBER POST OR F ‘—SBnBSTEELPOST/1](SEE NOTES 1 &9) 1.Refer to Standard Plans C-I and C-lb for additional details not shown on thIS plan. 2.Extend shoulder pavement to provide a base for the extruded curb See Contract Plans for exceptions to distances shown. 3.Use a single block or combination of blocks (no more than 2)to achieve the actual 12’(In)offset.See Standard SpecIficatIon 9-16.3(2).Wood blocks shall be secured to the posts with anti-rotation nails If combination blocks are used,the adjacent blocks shall be toenailed with two lEd galvanized nails to prevent block rotation 4 Wood blocks are shown.Blocks of an approved alternative matenal may be used.See Standard Specification 9-16.3(2). 5 All posts for any standard barrier run shall be of the same type timber or steel. SLOPEtEMBANKMENTTABLE — SHOULDER W—SEE TABLE 6 x 12 BLOCKOUT 12 (SEE NOTES 3 &41 ACTUAL 6x 8 TIMBER POST OR OS B STEEL POST (SEE NOTES 1 &51 FACE OF BEAM GUARDRAIL TEPE 31 NOTESBARRIER•—.—— 3’-1 112 -6’-3”6’-3”6’- MID SPAN 7 SPLICE GROUND LINE KINGEPOINT 00 z >- 0 TYPICAL SECTION -WITHOUT CURB (6’0 LONG POSTS) 4114 3-1 112 (TYP.)4114” (TYP.) N TYPICAL ELEVATION 13’-6 lIT 6’-3” SYMMETRICALABlUTI /GROUND LINE 3-11/2” T(TYP.)I 3)4”(IN)x 2 1/2 (IN)7SLOT(TYP.) SIB”(IN)14 (IN)BUTTON HEAD BOLT WITH 7I3T (IN)OVAL GRIP AND RECESSED HEX NUT (TYP) E TYPICAL RAIL ELEMENT 1 3/16” T(TYP( PLAN VIEW FACE OF BARRIER 3/4 (IN)DIAM HOLETHROUGHBLOCK / FOR TIMBER POSTATTACHMENT WOOD BLOCK SHOULDER Eu 12 BLOCKOUT (SEE NOTE 4) W —SEE TABLE ANTI-ROTATION — NAIL 164 (rEP SLOPE W IF-ri 2H -IV OR FLATTER 2.5’MIN. STEEPER THAN 2K IV BUT NOT 4.0’MIN. STEEPER THAN 1H.lv 5/B (IN)RECESSED /HEX NUT(WP)/ I 114 (IN)OIAM HOLE FOR ANTI-ROTATION 164 NAIL (TYP.)N OSxSx 6’LONG STEEL POST I I (SEE NOTES I (‘ 314 (IN)DIAM HOLE THROUGH BLOCK I Y1 FOR STEEL POST ATTACHMENT J.-‘ CUT WASHER (TYP.) 518 RECESSED 3/4”(IN)DIAM HOLE FOR BUTTON HEX NUT (TYP I HEAD BOLTCrYP)..-‘STEELPOST 6 u B x 6’LONG TIMBER POST (SEE NOTES 1 &5)— (SEE NOTE 3) (SEE NOTE 3)/ 5 6 TIMBER POST OR OS B STEEL POST (TEP.( ANTI-ROTATION NAIL 164 (TYP.) .-(SEENOTE3( 5 B TiMBER POST OR OSuBSTEEL POST (SEE NOTES 1 &51 PERMISSIBLE CURB PLACEMENTAREA (SEE NOTE 2) /GROUND UNE /HINDEPOINT—T SLOPE — SEE TABLE ELEVA11ON VIEW TYPICAL SECTION —WITH CURB (6’-0 LONG P05151 RAIL ELEMENT çTYP.) 5/SI (IN)22”(IN)BUTTON HEAD BOLT WITH 7/3T (IN)OVAL GRIP AND RECESSED HEX NUT )TYP.) SIB’(IN)vi l/4 (IN)BUTTON HEAD BOLT WITH 7)3T (IN)OVAL GRIP (TYPANDRECESSEDHEXNUTS— REQUIRED PER SPLICE lIjii. lc( ‘/‘“-‘/Ma )2O (4 3:117 PM BEAM GUARDRAIL TYPE 31 ISOMETRIC VIEW STANDARD PLAN C-20.1O-02 SKEET I OF I SHEET APPROVED FOR PUBLICATION ,L.. _________________ Wothiog*o,.Stoat Oplt.n,olT,ot.poflo1.. Label slope back of sidewalk 34’RIW 32’R/#—10’UTILITY EASEMENT CONCRETE PROPOSED MODULAR BLOCK WALL 9’MAXIMUM HEIGHT GUARD RAIL (Flush with the face of the curb) CEMENT CONCRETE VERTICAL CURB AND GUTtER (TYP.) ROAD A HALF STREET IMPROVEMENT (STA 0+63 TO STA 2+50)C NOT TO SCALE