Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutR-419503Ln
_O
O
W
F_
A PORTION OF THE NORTHEAST 1/4 OF SECTION 9, TOWNSHIP 23 NORTH, RAN/GE 5 EAST, W.M., KING COUNTY, WASHINGTON STATE
3' CHN LNK FNC I 1`� s ', z
oL MPIc PIPE LINE" SANITARY SEWER MANHOLE
RIM=416.4E /
O NO'19'43"W 1.82' IE=409.28, 8"PVC N
I£ _ / - N �W
U)
"E "PS8'4'37 _
~W
O O O OS884826E 359.25I I S' VC S A\6�
5 N?SK IN CASE
HN LNK pCONC STNE9TH PLJGRASS RI 6pC4CLNK FNC ox6O.fif
O O LAD-ExT�O U1 /7 WITH XDOWN
-• SS SS SS SS 006' EAST OF CALCULATED CENTERLINE ROADWAY 0�0 SS $SASPHALT (D / (0210612020)
0S 6 x 161 CP-2 HORIZONTAL CONTROL
-'• z' SANITARY SEWER MANHOLE ib�ILL _ = i o A /_ , _, I RIM =422. 5 Cf)� CI z SREETSI COORDINATE BASE POINT No. 2
I ° o 1E=414.0 8"PVC E 0
6'WOO \Ir I�z / / �� "\ _ \ IE=414.1,E"PVCS 4 X j ~ 33"CEDAR RP=12 FOUND MONUMENT
N i 1 STORM CATCH BASIN z 1/7
Z.
/ m \ I IE=414.06, 8-PVC NW _ II Q I
..;�, 0 �i /Lm m V ry \ FLOW EAST TYPE II 416.�43 STORM CATCH BASIN N 184446.815.E 1311371.952
z z / o / z �i o� z ro\ RIM=41Z65
I IE 412.3E 12"CPP E
ww ,,�� I. LADDER SOUTHWEST I I RIM=416.11
/ m / / 375. I .JIL. IE-413.51, 8"GONG E
z O \ 5 j ;� 1�J�o I z 1-�07� z \ `7j� o I _ CONV�.?q'ET. WALL P= IE=413.54, 8"CONC W
o i ; \ �.' [,.'�'i/„ i�iriii i a•.. V'`` o \ %-i \ IE=412.72, 6"P PSWF 0 9
/ / 0 TRAFFIC EED CAMERA
I / / / \ W LADDERSOUTH
12 PP W \ 41 .
i �i, �' 1��J� /� ° \ \ \ 6' WOOD FENCE
, r ' i � o / / fSTORM CATCH BASIN L�
/ / \ \ N N RIM=416.30 RP
z IE=412.59, 12"CPP N �
v7',/, N /A,-i
\ \ STORM CATCH BASIN 6h
/' „ „ , i , z z z / / oIP
z IE=412.55, 12"CPP W RIM=416.27/ o STORM MANHOLE
/ / \ IE=413.46, 6'CONC SE \
IE=411.26, 12 PVCN
z IE=411.06, 12"PVC NE
< • �.., �'ii ���i'� „ „i�„// ' , / / / / / tea. �ci \ l =6
z IE=411.23 12"PVCS
U .•O• 'ii/ / �i �'"�� '� i„i'' i� / z IE=412.93, 6"GONG NW
jI \}
LADDER EAST
ALTERNATE
PICNIC SHELTER
(NOTE: FOR A COMPLETE
DESCRIPTION OF THE
ALTERNATE SEE PROJECT
SPECIFICATIONS)
HORIZONTAL CONTROL BASELINE
= N 00024'50" W - 755.3847
/
/
/
/ V
/ 'i//'j / /,'/ ,// / ,,,/, ,/ „ /,,/ / / „ / ' /' ..,// / / / .•� ��, ,/ // spy (n I �
6P-10
1226
--
"CHN LNK FNC 1' ` z 6" OHVJIC FNCy-' I % ,./.� .� ♦ / ♦ / \ \ \/ / / \ ..� -O
/ \ C0<0 ITARY SEWER MANHOLE N88'4 6"W6196" CHN LNK FNC RIM=412.00
Q IE=406.36, 8"CONC S
.LADDER NORTHEAST NW
I.
ROCKERY
�7"
TL 0923059115 TL 0923059235 M Q a N Q 7^
TL 08898000� (n RIC
P-7
"BUS
STOP"
\\\\ \ \\\\ \\\\\♦ \ iti "20 MPH"
\\\\\ \\ \\\ \\\\ \ \ SCHOOL ZONE
// / 4145 / AND CAMERA
\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \
8"RP-9
\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ _ SANITARY SEWER MANHOLE
"' CONSTRUCTION DRAWING 20
CAUTION REFLECTOR 0' 30' IE=405.5$ 8"PVC N
(TYP.) FLOW SOUTHWEST
SW
SCALE GRID REFERENCE o?�; • EL°WSDUTHWEST
\ \ \ \ \ \ \ \ \ \ \ \ \ > > STORM CATCH BASIN 1 Q Cam' LADDER EAST STORM CATCH BASIN
LIMITS AND ID NUMBER. RIM=411.0E \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ � RIM=41L04
S
IE=409.43, 6"GONG SE IE=408.77, 6"GONG SE
ul 4 .90I II 4112 IE=408.35, 8"GONGS
IE=408.64, 8 CONC N
\\\\\ \ \ \ \\ \\\ \\
EEW
STORM CATCH BASIN
RIM=411.03
S IE=409.21, 6 PVC NW
IE=408.92, 8"DINE
I \ \ \ \ \ \ \ \ \ \ \ \ \ \ SANITARY SEWER MANHOLE ----I
RECOMMENDED CONSTRUCTION SEQUENCE • IEIM404.8738"CONC N U4 RIM-4AR58 EWER MANHOLE
IE=404.87, 8"CONC E IE=405.52, 8"CONC, N
(n
I \ \ \ \ \ \ \ \ \ \ \ \ \ IE=404.86, 8"CONC S Ul IE=405.35, 8"PVC, NE
1. ARRANGE FOR AND ATTEND PRE -CONSTRUCTION MEETING.
\ \ \ ♦ \ \ \ \ \ \ \ \ ♦ IIE=404.93, 8"GONG W IE=405.23, 6"GONG, E
\ \ \ \ \ \ \ \ \ \ I \ \ FLOW SOUTH TH IE=405.23, 8"GONG, S
�/ �/ \ \'1 / \ �/\ LADDER SOUTHEAST IE=405.48, 6"CONC, NW
2. POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR. as °S FLOW SOUTH
- P- LADDER EAST
STORM MANHOLE \ \ \ \ \ \ \ \ \ \ \ \ \ m RIM=411.47 FOUND 1.75" BRASS DISK IN CASE
\ \ \ \ \ ♦ \ \ \ \ \ \ \ \ \ \ ♦ I� STORM CATCH BASIN WITH 'PUNCH', DOWN 0.4f
3. FLAG OR FENCE CLEARING/GRADING LIMITS AS REQUIRED BY THE IE=40762, 12"CONCN 02062020
RIM=410.6
IE=40Z47, 12"GONGS '' D )
IE=407.8 8"GONG N -'RD AS C.O.R. CONTROL PT. #184F
\ \ \ 04 \ \ \ \ \ \ \ \ Z IE=4076 8"GONG W
APPROVED PLANS AND/OR PERMIT CONDITIONS.
CP-1 HORIZONTAL CONTROL
4. CONTACT CITY INSPECTOR (AND OWNER'S REPRESENTATIVE) TO INSPECT AND COORDINATE BASE POINT No. 1
SIGN -OFF ON CLEARING LIMITS PRIOR TO ANY CLEARING. I
m FOUND MONUMENT 1848
N 183691.450 : E 1311377.410
5. INSTALL INITIAL EROSION CONTROL PRACTICES; GRADE AND INSTALL
NE p W
L CONSTRUCTION ENTRANCE(S), INSTALL PERIMETER PROTECTION (SILT FENCE,
T=7 ZTL=145.0 _-� ASPHALT NE 7
R=39 .09 4=20'4 00" \
0
BP GAS PIPELINES* (BURIED),
RUNNING NORTH THROUGH
THE WEST SIDE OF THE SITE
CITY LIGHT TRANSMISSION LINES*
(OVERHEAD), RUNNING NORTH THROUGH
THE WEST SIDE OF THE SITE
*CONTRACTOR TO COORDINATE WITH BP
PIPELINES AND CITY LIGHT PRIOR TO BEGINNING
ANY CONSTRUCTION -SEE BP GENERAL SAFETY
REQUIREMENTS NOTES ON THIS SHEET.
STRAW WATTLES, BRUSH BARRIER, ETC.), CONSTRUCT SEDIMENT PONDS AND
TRAPS (IF REQUIRED).
6. CONTACT CITY INSPECTOR FOR INSPECTION OF INITIAL EROSION CONTROL
PRACTICES PRIOR TO COMMENCEMENT OF GRADING ACTIVITY.
7. CLEAR, GRADE, AND FILL SITE AS OUTLINED IN THE CONTRACT PLANS AND
SPECS WHILE IMPLEMENTING, MAINTAINING, AND ADJUSTING AS REQUIRED THE
TEMPORARY EROSION AND SEDIMENT CONTROL PRACTICES AT THE SAME TIME.
8. INSTALL PROPOSED UNDERGROUND UTILITIES AND OTHER IMPROVEMENTS.
9. INSTALL PERMANENT EROSION PROTECTION (IMPERVIOUS SURFACE,
LANDSCAPING, ETC.).
10. CONTACT CITY INSPECTOR FOR APPROVAL OF PERMANENT EROSION PROTECTION
AND SITE GRADES.
11. REMOVE TEMPORARY EROSION CONTROL METHODS AS PERMITTED BY THE CITY
INSPECTOR AND REPAIR PERMANENT EROSION PROTECTION AS NECESSARY.
12. MONITOR, MAINTAIN, AND RELOCATE SURFACE WATER CONTROLS AND EROSION
CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS
CHANGE THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE
WITH THE CITY OF RENTON EROSION AND SEDIMENT CONTROL STANDARDS.
13. CLEAN STORM WATER CONVEYANCE SYSTEM (ON -SITE AND DOWNSTREAM) OF
ALL SEDIMENT AND DEBRIS TO THE SATISFACTION OF THE CITY OF RENTON.
ENSURE OPERATION OF THE SYSTEM.
14. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE
STABILIZED AND BEST MANAGEMENT PRACTICES REMOVED AS APPROPRIATE.
0 20 40 80
GRAPHIC SCALE
GENERAL PERMIT INFORMATION
1. NPDES PERMIT NUMBER
2. THE ENGINEER OF RECORD SHALL PROVIDE AN ENGINEER'S CERTIFICATION TO THE
CITY OF RENTON AFTER FACILITY INSTALLATION AND PRIOR TO PERMIT FINAL
INSPECTION AND/OR CLOSEOUT.
3. THE APPLICANT SHALL SUBMIT RECORD DRAWINGS ('AS-BUILTS') TO THE CITY OF
RENTON WHEN THE PROJECT IS COMPLETED.
4. ANY CHANGES OR REVISIONS TO THE ORIGINALLY APPROVED PERMIT SUBMITTAL SHALL
BE SUBMITTED TO THE CITY OF RENTON PRIOR TO CONSTRUCTION.
5. STORM CONNECTION PERMIT REQUIRED. CONTACT PLANNING AND DEVELOPMENT
SERVICES AT 425.430.7294 FOR ADDITIONAL PERMITTING INFORMATION.
6. A SIDE SEWER CONNECTION PERMIT IS REQUIRED. CONTACT PLANNING AND
DEVELOPMENT SERVICES AT 425.430.7294 FOR ADDITIONAL PERMITTING INFORMATION.
7. PROVIDE THE CONTACT INFORMATION FOR THE CONTRACTOR'S CERTIFIED EROSION AND
SEDIMENTATION CONTROL LEAD (CESCL) AS REQUIRED BY THE WASHINGTON STATE
DEPARTMENT OF ECOLOGY (WSDOE) AT THE PRE -CONSTRUCTION MEETING (SEE NOTES
ON SHEET D2.1).
UTILITY NOTE
1. CONTRACTOR SHALL VERIFY EXISTING UTILITY LOCATIONS PRIOR TO DEMOLITION AND
CLEARING. CONTACT 'CALL BEFORE YOU DIG' AT (800) 424-5555 FOR FIELD LOCATION
ASSISTANCE WITHIN THE PUBLIC RIGHT-OF-WAY, RETAIN A PRIVATE LOCATOR SERVICE
TO LOCATE UTILITIES WITHIN THE PROJECT SITE.
2. SEE SHEET D2.1 FOR CITY OF RENTON GENERAL NOTES, EROSION AND SEDIMENT
CONTROL NOTES, RECOMMENDED CONSTRUCTION SEQUENCE NOTES, AND EROSION
CONTROL SEEDING MIX NOTES.
3. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND
HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE.
THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES
BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND
ALL DAMAGES THAT INCUR DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY
AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. BRUCE DEES & ASSOCIATES
ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES.
TOPOGRAPHIC NOTE
THE EXISTING CULTURAL AND TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN
PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS
INFORMATION IS BELIEVED TO BE RELIABLE, BRUCE DEES & ASSOCIATES CANNOT ENSURE
ITS ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION
OR FOR ANY ERRORS OR OMISgONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE
DRAWINGS AS A RESULT.
TRENCH NOTE
IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH
THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT
SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR
WORKER SAFETY AND BRUCE DEES & ASSOCIATES ASSUMES NO RESPONSIBILITY. ALL
TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE WASHINGTON
INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17 RCW.
UTILITIES/SERVICES
WATER CITY OF RENTON 425 430-7210
SANITARY SEWER CITY OF RENTON 425 430-7212
STORM SEWER CITY OF RENTON 425 430-7248
POWER PUGET SOUND ENERGY 888 321-7779
GAS PUGET SOUND ENERGY 888 321-7779
TRANSMISSION LINES SEATTLE CITY LIGHT 206 684-3325
STRIPPING
1. STRIP ALL TOPSOIL UNDER ALL PROPOSED IMPROVEMENTS. STRIPPINGS MAY BE USED
TO CONSTRUCT LANDSCAPE BERMS.
2. NOTE: AREAS AT PROPOSED LANDSCAPE BERMS MAY BE TILLED AND NOT STRIPPED.
LANDSCAPE BERMS
1. STRIPPINGS MAY BE USED TO CONSTRUCT LANDSCAPE BERMS. PLACE MATERIAL IN
TWELVE (12) INCH LIFTS AND COMPACT WITH A TRACKED PIECE OF EQUIPMENT.
2. USE SUITABLE ON SITE MATERIAL, AS REQUIRED, TO ACHIEVE A UNIFORM SUBGRADE
PRIOR TO PLACING TOPSOIL.
3. OBTAIN APPROVAL OF THE FINISH SUBGRADE PRIOR TO CONSTRUCTING IRRIGATION OR
PLACING ANY TOPSOIL.
4. COMPLETE IRRIGATION TRENCHING AND LINES AND RE-ESTABLISH THE SUBGRADE.
5. OBTAIN APPROVAL OF RE-ESTABLISHED SUBGRADE PRIOR TO PLACING TOPSOIL.
6. PLACE APPROVED TOPSOIL TO THE SPECIFIED COMPACTED DEPTH AND FINISH GRADE.
7. OBTAIN APPROVAL OF FINISH GRADE PRIOR TO SEEDING/SODDING/PLANTING.
8. ALLOW FOR MINOR ADJUSTMENTS IN THE FINAL FINISH GRADE AS DIRECTED.
EXCESS AND UNSUITABLE SOIL
EXCESS STRIPPINGS AND OTHER UNSUITABLE SOIL SHALL BE REMOVED FROM THE SITE.
PLAN SCALE NOTE
PLANS ARE DRAWN AT TWO DIFFERENT SCALES: 40 SCALE DRAWINGS COMPRISE OVERALL
'SITE' PLANS. 20 SCALE DRAWINGS COMPRISE GRID PLANS, GRIDS '1' THRU '3'.
HORIZONTAL CONTROL
HORIZONTAL CONTROL IS FROM CALCULATED COORDINATES BASED ON THE TWO
HORIZONTAL CONTROL COORDINATE BASE POINTS (CP-1 AND CP-2) SHOWN, WITH THE
HORIZONTAL CONTROL BASELINE AS NOTED.
PROJECT LAYOUT & STAKING
FIELD LOCATING AND STAKING OF PROPOSED SITE IMPROVEMENTS SHALL BE BY
DIMENSIONS SHOWN ON DRAWINGS AND COORDINATES OBTAINED VIA ELECTRONIC DRAWING
FILES WHICH WILL BE PROVIDED WITHIN 5 DAYS OF RECEIVING WRITTEN REQUEST
FOLLOWING NOTICE OF AWARD. DIMENSIONS SHOWN ARE TAKEN AT CENTERLINE OF FENCE
AND/OR FACE OF CURB UNLESS OTHERWISE NOTED.
ALTERNATES:
SEE BID FORM AND SECTION OF THE PROJECT SPECIFICATIONS FOR A
COMPLETE DESCRIPTION OF PROJECT ALTERNATES.
BP GENERAL SAFETY REQUIREMENTS
THE CONTRACTOR IS REQUIRED TO FIRST CALL 811, THE NATIONAL "ONE -CALL" NUMBER,
AT LEAST 48 HOURS (2 WORKING DAYS) BEFORE ANY CONSTRUCTION AND/OR EXCAVATION
ACTIVITIES ARE INITIATED WITHIN THE PIPELINE RIGHT-OF-WAY. A REQUESTOR MAY MAKE A
NOTIFICATION ONLINE AT http://call811.com/811-your-state . BP MAY HAVE A
REPRESENTATIVE PRESENT TO ENSURE THAT THERE ARE NO CONFLICTS WITH THE PIPELINE
AS A RESULT OF THE WORK. THERE IS NO COST TO USE THE ONE -CALL NOTIFICATION
SERVICE. HOWEVER, FAILURE TO UTILIZE THE ONE -CALL SERVICE IS A VIOLATION OF
REGULATORY REQUIREMENTS AND MAY BE SUBJECT TO THE OFFENDER TO POTENTIAL CIVIL
PENALTIES* AND DAMAGES FOR PERSONAL INJURY AND/OR DESTRUCTION OF PROPERTY.
*REFER TO WASHINGTON STATE RCW 19.122.030
TO HAVE THE PIPELINE PHYSICALLY LOCATED AND ITS DEPTH VERIFIED, PLEASE CONTACT
A BP RIGHT OF WAY AGENT AT BPPipelinesROW@bp.com.
BP REQUIRES ITS REPRESENTATIVE TO BE ON SITE WHEN ANY WORK IS BEING
PERFORMED WITHIN 25 FEET OF THE PIPELINE(S) OR WHEN THE REACH OF MECHANICAL
EQUIPMENT IS CAPABLE OF EXTENDING WITHIN TWENTY FIVE FEET OF THE PIPELINE(S). BP
REQUIRES FORTY-EIGHT (48) HOURS' (2 WORKING DAYS) PRIOR OF ANY WORK. NOTICE
TO BP DOES NOT RELIEVE ANY REQUESTOR OF ITS OBLIGATION TO CONTACT THE
APPROPRIATE STATE ONE -CALL SYSTEM.
THE CONTRACTOR IS RESPONSIBLE FOR TAKING ALL NECESSARY SAFETY PRECAUTIONS AND
WILL BE HELD RESPONSIBLE FOR ANY DAMAGES TO PROPERTY OR FOR PERSONAL INJURY
CAUSED BY THE WORK.
BP REPRESENTATIVE: Chase Wakefield (425) 981-2575 chose.wakefield@bp.com
r ^ C C E
v J OJm mg
wy N
O6
2 N
(0
m
L
�
�o
m Ua
3 c
U N
L) �o
0 Q �
� o
w�^ mz
�a�
U 1p
V J N C
�N
Na
J (/)
N3
m
Sri
�
�
Sri
o
Of
(f)
o
LLJ
Z
Y
LL1
0
U
Q
N
co N
0 �o
o°w
z y=
z
I w
IMU wo
(nJ U�
�s
�
m
m
m
Q
N
N
W
Q00
o
0
w
V)
z
v7
0
a
Z
N
W
O
z
V)
LLI
>
o
w
W
m
p
J
O
W
cn
r2
LU
H
cd
0
O
a
a
•,..,
P4
O
!"1
U
G03
R-419503
Sheet 3 of 40
CONSTRUCTION SET
Copyright©2022 - Bruce Dees & Associates (All Rights Reserved)
CADD filename: R:\DRAKINGS\17501 - RENTON KIWANIS PARK IMPROVEMENTS\13 - CONST. SET\17501-G0.1-G0.3.DWG // Plotted: 4.13.22-18:37 By"(sjensen) BID #: