HomeMy WebLinkAboutW-393006C) M M I CMMV I.� 1-1/2" AND 2" WATER SERVICE DETAIL CAUTION: VALVE BOX SHOULD NOT REST ON i0 11 PIPE. LATER COMPACTION IN AREA OF VALVE BOX COULD CAUSE THE BREAKAGE OF THE SERVICE 2, CITY w PIPING z J IN UNIMPROVED w Z > RIGHT-OF-WAY INSTALL METER BOX AT PROPERTY LINE WITH w 12" LONG COPPER TAILPIECE O d 9" MIN. 12" MAX. ZXD 9 M; -LEAVE EXPOSED , o N 12" BY PASS NOT ALLOWED FOR IRRIGATION METERS 1 PRIVATE PIPING 1 CRUSHED ROCK BASE TO SUPPORT A - A VAULT. DRILL 2' DIA. HOLE FOR TOUCHREAD DEVICE QUICK -JOINT COUPLING x MIPT CAST IRON OR DUCTILE IRON WATERMAIN 2-1/2' MIN. FROM NEAREST NOTE: AND FRONT EDGE OF PIT LID THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF -F MORE THAN ONE RIB. TYPICAL RIB MATERIAL LIST FOR 2" SERVICE: METER LOCATED IN PLANTING STRIP MATERIAL LIST FOR 1-1/2" SERVICE: METER LOCATED IN PLANTING STRIP BETWEEN CURB & SIDEWALK BETWEEN CURB & SIDEWALK 1. 2" topped tee, on new water main. 1. 2" topped tee on new water main. 2. 4" long X 2" brass nipple with threaded ends (MIPT). 2. 4' long X 2" brass nipple with threaded ends (MIPT). 3. 2" resilient seat gate valve with threaded ends, square operating nut, 3. 2" resilient seat gate valve with threaded ends, square operating nut, and and valve nut extension if required (see standard detail 330.1). valve nut extension if required (see standard detail 330.1). 4. Two piece cast iron valve box. Standard 8" top section with regular 4. Two piece cast iron valve box Standard 8" top section with regular base base section, length to fit, "lug" type cover. 2" brass bushing (MIPT x section. length to fit, "lug' type cover. FIPT). 5. 2" X 1-1/2" hex brass bushing (MIPT x FIPT). 2 each 1-1/2" brass or 5. 2 each 2" brass or bronze nipples 6" length. threaded ends- 2 each bronze nipples 6' length. threaded ends. 2 each 1-1/2"-90' brass or 2"-90' brass or bronze elbows (FIPT x FIPT). bronze elbows (FIPT x FIPT). 6. 2" (MIPT) x compression fitting, Ford C84-66 or equal. 6. 1-1/2" (MIPT) x compression fitting, Ford C84-66 or equal. 7. 2" soft copper tubing type K or brass nipples (MIPT x MIPT), length to 7. 1-1/2" soft copper tubing type K or brass nipples (MIPT x MIPT), length fit. to fit. B. 2" threaded brass 90' ell. 8. 1-1/2" threaded brass 90' ell, for Ford L44-77 or equal. 9. 2" Customsetter with by-pass Ford: VBH 86-128-11-77 x 17-3 1V 9. 1-1/2" Customsetter with t ass Ford: VBH 86-12B-11-66 x ), McDonald Brass: 3OB715WDFF775 or Mueller B-1427-2, with flanged 13-3/167, McDonald Brass: 3OB612WDFF665 or Mueller B-1427-1 1/2", angle bull valve and padlock wings on inlet and angle check valve with flanged angle ball valve and padlock wings on inlet, and angle check outlet, ball valve on bypass with padlock wings. Customsetter shall valve outlet, ball valve on bypass with padlock wings. Customsetter shall have vertical inlet and outlet. have vertical inlet and outlet. 10. Rigid meter spreader to be supplied and installed in meter setter by 10. Rigid meter spreader to be supplied and installed in meter setter by contractor. contractor. 11. Water meter shall be supplied and installed by City of Renton upon 11. Water meter shall be supplied and installed by City of Renton upon payment of all related water meter fee and satisfactory pressure and payment of all related water meter fee and satisfactory pressure and purity tests. purity tests. 12. 17"x3O" Plastic meter box equal to Mid -States Plastics, Inc. BCF Series 12. 17'x30' Plastic meter box equal to Mid -States Plastics, Inc. BCF Series MSBCF 1730-18 with 2" thick Ductile iron diamond plate cover 18"x31" MSBCF 1730-18 with 2" thick Ductile iron diamond plate cover 18"x31" equal to Mid -States Plastics, Inc. MSCBC-1730-R with 2" drilled hole equal to Mid -States Plastics, Inc. MSCBC-1730-R with 2" drilled hole for for touchreod pit lid, and meter read lid. touchread pit lid. 13. 2" coupling (compression x FIPT) with 2" plug (MIPT), Ford C-14-66 13. 1-1/2" coupling (compression x FIPT) with 1-1/2" plug (MIPT), Ford or equal. The property owner is responsible for any necessary adaptation or C-14-66 or equal. The property owner is responsible for any necessary extension of water service. adaptation or extension of water service. NOTE: ALL METER BOXES INSTALLED IN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUST BE INSTALLED 12' MINIMUM ON BOTH SIDES OF METER BOX. STD. PLAN - 320.2 �► � � PUBLIC WORKS 1 '2'" AND 2" WATER SERVICE LOCATED DEPARTMENT IN PLANTING STRIP MARCH 2O10 WATER SERVICE LOCATED IN PLANTING STRIP (COR STD. PLAN 320.2) NOT TO SCALE GENERAL WATER NOTES 1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AT (425) 430-7301. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 4. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE PRE -CONSTRUCTION MEETING. 5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL WATERMAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105/A21.5-93 STANDARDS. 7. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/421/4-90. IF FITTINGS ARE 3 TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL IN ACCORDANCE WITH EITHER ANSI/AWWA C110-A21.10-87 OR ANSI/AWWA C153/A21.53-94. THREE (3) INCH TO 12 INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.87 OR A COMBINATION OF ANSI/AWWA C110/A21.10.87 AND ANSI/AWWA C153/A21.53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH ANSI/AWWA C153/A21.53-94 AND THAT PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10-87. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA C110/A21.10-87 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. AS -BUILT I CERTIFY THAT THE INFORMATION SHOWN HEREON WHICH WAS AS -BUILT BY AHBL ,AND MAY INCLUDE NOTICE LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND ALTERAnaNaFTHISDOCI1YENrSHALLNviUIDA1ETIE PROFES90NAL SEAL AND SIGNATURE PUBLICATION OF AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING THISDOCI11E11TD0ESNorDEROGAIEFROMRESERVED OINERSIIP RNAi1S N R THIS DOCUIENT IS FOR USE FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY �YFGRTHEPRo,IEcrIDENTIREDNTHEnTLEeloac AND IS NOT TO BE USED FOR REPAN, REMODEL OR DIRECT SUPERVISION ON THIS DATE: 08/23/2019. AoanorlTonlArPRo,ECTaRFGRANYOTHBtPROJEcr. W a z Ld REGISTER SHALL BE TOUCH READ PIT LID - (TR-PL) AND BE INTELLIGENT COMMUNICATION ENCODER TYPE (ICE). METER MUST READ IN Cu. FT. 4" 90" BEND (MJ) "GAE -,Mal) OR 47 POST INDICATOR VALVE (MJxMJ) PAINTED BLUE 2-3/4" SHACKLE RODS PER CITY OF RENTON SPECIFICATIONS 4' 90- SEND (MJ) �INSTALL IN TEST PORT A 2"x2' 12' \ 13 LF C D.I. BRASS NIPPLE WITH A 2" RESILIENT SEATED BRASS GATE VALVE AND 2" PLUG. J LADDER PATH SUPPORT BARS _'2 -4 4" R.MJ ADAPTOR v PER OSHA TO BUILDING �� EPDXY NON -SHRINK GROUT .�4„ 4" TEE (MJxFL) WELDED STEEL COLLAR CITY PRIVATE TOUCH READ PIT LID SENSOR MOUNTED ON STEEL PLATE COVER THROUGH 2" DIA. PIPING PIPING DRILLED HOLE IN COVER. LOCATE HOLE 2Xz' DEADMAN BLOCK FROM EDGE OF PIT LID AND RIBS. ( TEE REQUIRED WITH (FL) SHACKLING TO TEE PRECAST CONCRETE VAULT WITH 2 3"x3" HINGED STEEL PLATE COVER. OUTSIDE DIMENSIONS 4'-8"x7'-6"_ (EQUAL TO PIPE INC., OR UTILITY VAULT WITH 57-7L-B, 2 SxS DIAMOND PLATE DOORS) SENSUS MODEL 520R RADIO READ PIT SET SENSOR MOUNTED ON STEEL PLATE TWO PIECE CAST IRON VALVE BOX, 6",4" OR 3' GATE VALVE (FLXFL) COVER THROUGH 2' DIA EQUAL TO OLYMPIC FOUNDRY CO. NON -RISING STEM WITH HAND WHEEL DRILLED HOLE IN COVER STANDARD 8" TOP SECTION, WITH EQUAL TO MUELLER CO.A-2380-6. REGULAR BASE SECTION LENGTH TO FI- E" OR 4" (FLxPE) CEMENT LINED DUCTILE IRON PIPE CLASS 52 S-6" LONG WITH COLLAR 20' FROM P.E. EQUAL TO THOSE SUPPLIED BY PACIFIC 3" 4" VALVE NUT EXTENSION IF REQUIRED WATER WORKS CO. INC. (DWG BR46/PAGE B090) FLOW- I lti 12" AROUND 12' - 6",4' OR 3' COMPOUND WATER METER (FL) EQUAL TO SENSUS SRII COMPOUND METER WITH TOUCHREAD PITUD I.C.E. REGISTER & SENSOR ZADJUSTABLE WITH 4 WHEEL HIGH RESOLUTION 100 CUBIC ( STEEL FEET) REGISTER. FOR 3" METER, REDUCE AT PIPE SUPPORT METER WITH 4'X3" FLxFL CONCENTRIC STANCHION BOLTED REDUCER. TO FLOOR GENERAL NOTES: ALL METERS AND BACKFLOW PREVENTION DEVICE COMBINATIONS ARE NOT SHOWN OR INCLUDED IN THE STANDARD DETAIL DRAWINGS. IF YOUR PARTICULAR COMBINATION IS NOT SHOWN, AN APPROVED DRAWING WALL BE REQUIRED BY THE UTILITY ENGINEERING DEPT. FOR ITS INSTALLATION. THE PRINCIPAL REQUIREMENTS REGARDING VAULT SIZING ARE THE LENGTH OF FITTINGS OR THEIR CLEARANCE FROM THE VAULT WALLS, (WHICH CLEARANCE SHALL BE A MINIMUM OF 12" FROM THE ENDS AND THE SIDE CLEARANCE SHOULD BE AS TYPICALLY SHOWN ON THE VARIOUS STANDARD DETAILS). NOTE: DEADMAN BLOCK SHALL BE DESIGNED AND INSTALLED SO IT SEARS AGAINST SUFFICIENT UNDISTURBED EARTH SO AS TO SUPPORT THE DESIGNED THRUST. 6", 4" OR 3" GATE VALVE (FLxMJ) EQUAL TO MUELLER CO. A-2380-20. TO BUILDING 4" CITY PRIVATE PIPING PIPING 6" OR 4" PExPE CEMENT LINED DUCTILE IRON PIPE CLASS 52- LENGTH TO FIT. 6" OR C FLEXIBLE FLANGED COUPLING ADAPTOR. ROMAC OR APPROVED EQUAL STD. PLAN - 320.4 i►�� PUBLIC WORKS 3", 4" & 6" COMPOUND DOMESTIC DEPARTMENT WATER METER ASSEMBLY MARCH 2O10 �'NTQ COMPOUND DOMESTIC WATER METER ASSEMBLY (COR STD. PLAN 320.4) NOT TO SCALE 8. GATE VALVES SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND O-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509). UTILITY SPECIFICATIONS VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380 OR M & H. 9. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE (OPENING AGAINST PRESSURE) CONFORMING TO AWWA C-502-85 WITH A 6 INCH MECHANICAL JOINT INLET AND A MAIN VALVE OPENING (M.V.O.) OF 5-1/4 INCH, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4 INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1-1/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT). 10. THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. 11. THE 4 INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4 INCH SEATTLE THREAD X 5 INCH STORZ. STORZ ADAPTER SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART. STORZ FACE TO BE METAL, NO GASKET TO WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 12. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 3-655 SAFETY YELLOW OR APPROVED EQUAL. 13. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. 14. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS,LATEST REVISION. 15. ALL WATERMAINS 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12 INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATERMAINS ARE TO BE LOWERED TO CLEAR. 16. ALL WATERMAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY. pf Trash 1��'Jy ■ - 3 Jf11 2 �� �EGII $�E F� �y�� T A C O M A • SEATTLE • SPOKANE •TRI-CITIES 1 �SSIONAL E��l 2215 North 30th Street, Suite 300 Tacoma, WA 98403 NO. /23/201 9253.383.2422 TEL 253.383.2572 FAX www.ahbl.com NEB RAMP REVISION STORM DRAINAGE REVISIONS CITY COMMENTS ADDENDUM NO. 3 ADDENDUM NO. 1 REVISION W z > J 3: E- Iw L� � 10 cifH 0 ddo TO CITY METER STACKED METER SECTION 6" MIN. FREE BOXES DRAINING GRAVEL NOTES: 1. ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS -CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. PUBLIC WORKS 34" TO 2" DOUBLE CHECK VALVE STD. PLAN - 340.8 �► * � ` ASSEMBLY FOR IRRIGATION OR DEPARTMENT RESIDENTIAL FIRE SPRINKLER MARCH 2O10 DOUBLE CHECK VALVE ASSEMBLY FOR IRRIGATION (COR STD. PLAN 340.8) NOT TO SCALE fr A�07i ❑❑ 0 T T o OUTFACE TD STREAM(DUMP NO POLLUTANT TOP 24" 7 OR 8 EQUAL SPACES ,n _DIRECTION OF FLOW SECTION O ISOMETRIC 1`tY O PUBLIC WORKS �NTO� DEPARTMENT 17. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 18. ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTON UTILITY SPECIFICATIONS STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 19. ALL WATERMAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/INJECTED IN ACCORDANCE WITH SECTION 7-11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. 20. A PRE -CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 21. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 22. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 23. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF RENTON. 24. ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS. 25. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. 26. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 27. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED SLOT -SEE DETAIL AND NOTE 1 J SECTION O 1/2' 1 1/4" BOLT -DOWN SLOT DETAIL SEE NOTE t NOTES I. Provide two slots in the grate that are vertically aligned with the holes in the frame. Location of bolt -down slots varies among different manufacturers. 2. Refer to Standard Specification 9-05.15(2) for additional requirements. 3. Unless otherwise specified, vaned grates shall be used with standard frame in the travel way, gutter or shoulder. vaned grates shall not be located within crossroads. Use vaned grates along rolled curbs. RECTANGULAR MD. PLAN - 204.20 VANED GRATE MARCH 2O08 RECTANGULAR VANED GRATE (COR STD. PLAN 204.20) NOT TO SCALE BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. 28. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 29. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. 30. FOR CITY PROJECTS SUCH AS TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE ALL CHEMICAL PROCESS LINES SHALL BE SCHEDULE 80 PVC PIPE. SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 PVC PIPE UNDER IMPROVED AREAS. CONSTRUCTION RECORD DRAWINGS WJF 2/22/181 WJF SURVEYED: D. FOLLANSBEE SCALE: AS SHOWN HORZONI NAD D1983/11991 �� U �`� CITY OF WJF 12/13/17 WJF DESIGNED: G. TAUSCHECK �� 10 RENTON WJF 4/21/17 WJF DRAWN: WJF 3/17/17 WJF F. KATONA ONE INCH AT FULL SCALE IF NOT ONE INCH DATUM Plonnin Buildin Public Works Dept. g/ g/ p WJF 3/1/17 WJF CHECKED: W. FIERST BY DATE APPR SCALE ACCORDINGLY APPROVED: S. COMFORT APPROVED FOR CONSTRUCTION SUBJECT TO ERRORS AND OMISSIONS BY: DATE: BY: DATE: BY: DATE: BY: DATE: SARTORI ELEMENTARY SCHOOL 05/04/2017 FIELDRENTON SCHOOL DISTRICT PAGE: OK: PAGE: WATER NOTES AND DRAWING N0: DETAILS III C7.7 SHEET:37 OF: CV O CD CD C9 W-393006