Loading...
HomeMy WebLinkAboutS-393001T I I I 1 1 1 I w I w J 1 II it w II 1 II DC CDoil 11 II 1 Q _ 1 O O ��_ - _ SSMH 666 RIM=36.01 22" ER C E-W CENTER CHANNEL=27.66 _ - - - - - - - - - 8' PVC S IE=28.36 NORTH H-STREET----c - 0 - - O ;_ l _ 1-� -_- -_--_-_ _ _ Lj C4.1 "------- %�ESHEET --- -WATER PLAN ................ .... -----w - w----- w -----w-- = = = = = = = i III 45; LECTRICAL VA T, SEE LECTRICAL PLANS, SHEET I J ull \ E 1 AND E102CD NINa> �� ❑ I I II 7\7 I I II u III IG FIRE LANE - NO PP. SSMH 4174 RIM-v .ti8 8" PVC N-S CENTER CHANNEL=29.03 1 �, 1 �I I 1i I �38.3 2HR PARK (,b CENTER OF 1 (Y� CHANNEL: 29 3 LADDER E 1 1 I � I 1 11il Vl 0 1 SEE SHEET C4.2 1� FOR SANITARY 1 SEWER PLAN 1 AND SHEET C4.3 1 FOR SANITARY " SEWER PROFILE I III ' i i I 00 1 1 III 1 I I M I� co 1 co 1 1 I 1 I 2HR PARKING 1 I I I 1 I I 1 I I 1 �I 1 I 1 � VENT PIPE, SEE ; 1 MECHANICAL PLANS FOR CONTINUATION 1 III FOR CONTINUATION OF GAS DESIGN SEE ICI MECHANICAL PLANS, SHEET P100A AND P101A L C 0 it III T I I COORDINATE PROPOSED GAS SERVICE WITH PUGET SOUND ENERGY (PSE). WORK SHALL BE COMPLETED BY _ 1 PSE AT THE EXPENSE OF THE CONTRACTOR. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS I - - - C I INCURRED TO CONSTRUCT THE GAS SERVICE. TRENCHING, BEDDING AND BACKFILL FOR THE GAS LINE I V10 ® SHALL BE PROVIDED BY THE CONTRACTOR. A SEPARATE III FRANCHISE PERMIT IS REQUIRED FOR GAS INSTALLATION -- I IN THE PUBLIC RIGHT-OF-WAY. �r, do AN _'_..:T _ ■ i t-�� ice'=7r'i ,-�' _ ..�!' _ �ti. �i .■ I i.i .C�i�t'� Ad .: �: ►�II�VI • �� ;1 ,,� �i uI s I�R SSMH 2428 RIM=37.25 42" CONC E-W CENTER CHANNEL=24.75 LADDER N 1 (- II ���I LJ x ll 5" 1 I ° II 1 mom CERTIFY THAT THE INFORMATION SHOWN HEREON WHICH WAS AS -BUILT BY AHBL ,AND MAY INCLUDE NOTICE LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND ALTERA710NaFTNISDOCI1YENrSHALLNVMIDAIETIE PROFES90NAL SEAL AND SIGNATURE PUBLICATION OF AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING TNISDoanENTDGESNorDERocATEFROMRESERVED OIMERSIIP RN#115 N R THIS DOCUIENT IS FOR USE FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY afLTFORIHEPRo�ECTIDENiFIDN1HE11TLEBLODC AND IS NOT TO BE USED FOR REPAIR, REMODEL OR DIRECT SUPERVISION ON THIS DATE: 08/23/2019. AODInoNTOTNArPRaECTaRFGRANTOTNERPRo�Ecr. LJ a z J I J. 5 RAMP REVISION 4 STORM DRAINAGE REVISIONS 3 CITY COMMENTS 2 ADDENDUM NO. 3 �1�pGI,$�E TACO M A• SEATTLE • SPOKANE •TRI-CITIES 1 ADDENDUM NO. 1 �� IONAL E��l 2215 North 30th Street, Suite 300 Tacoma, WA98403 N0. REVISION /23/201 9253.383.2422 TEL 253.383.2572 FAX www.ahbl.com NEB N GRAPHIC SCALE 0 20 40 80 1" = 40 FEET WJF 2/22/1 8 WJF SURVEYED: SCALE: D. FOLLANSBEE AS SHOWN WJF 12/13/17 WJF DESIGNED: G. TAUSCHECK WJF 4/21/17 WJF WJF 3/17/17 WJF DROWN: F. KATONA ONE INCH AT FULL SCALE IF NOT ONE INCH WJF 3/1/1 7 WJF CHECKED: W. FIERST BY DATE APPR SCALE ACCORDINGLY ,APPROVED: S. COMFORT PROPOSED LEGEND: NOTES • BOLLARD 1. ALL CONNECTIONS TO EXISTING CITY WATERMAINS SHALL BE DONE BY CITY. SANITARY SEWER MANHOLE CONTRACTOR SHALL REFER TO CITY STANDARD DETAILS 300.1 TO 300.5 FOR • SANITARY SEWER CLEANOUT "BEFORE & AFTER" CONNECTION DETAILS. OD 2. "POLYPIGGING" STATIONS SHALL BE VERTICAL CROSSES PER CITY STANDARD O ■ STORM CATCH BASIN � DETAIL 300.6. O ■� STORM MANHOLE p ADS ROOF DOWNSPOUT O c.� o GAS METER GAS VALVE FIRE SPRINKLER NOTE UTILITY POLE E- UTILITY POLE ANCHOR WHERE THE UNDERGROUND WATER SUPPLY TEES OFF TO SERVE ONLY A FIRE SPRINKLER SYSTEM, A SEPARATE DETAILED PLAN MUST BE SUBMITTED BY THE PAD MOUNTED TRANSFORMER COTRACTOR AND APPROVED BY THE FIRE MARSHAL PRIOR TO INSTALLATION. © POWER VAULT � THRUST BLOCKING FIRE PROTECTION NOTES 90° BEND MJ THE FIRE PROTECTION SYSTEM INCLUDING MATERIALS, SIZING, AND 45° BEND MJ CONFIGURATION IS SUBJECT TO A CONTRACTOR PROVIDED DESIGN BY A FIRE PROTECTION ENGINEER, AND AS SUCH, THE FINAL DESIGN OF THE FIRE CV 22.5° BEND MJ PROTECTION SYSTEM MAY DEVIATE FROM THE SYSTEM SHOWN. THE FIRE O PROTECTION SYSTEM AS SHOWN FROM THE MAIN LINE TO THE CONNECTION C9 �-� 11.25° BEND MJ AT THE BUILDING SPRINKLER IS INTENDED FOR LOCATION OF THE FIRE O O TEE FL HYDRANTS AND FIRE DEPARTMENT CONNECTION ONLY. CONTRACTOR'S BID p SHALL REFLECT THE CONDITIONS OF THE FIRE PROTECTION ENGINEER'S ' TEE MJ DESIGN. CONTRACTOR SHALL COMPLY WITH ALL NATIONAL FIRE O PROTECTION ASSOCIATION REQUIREMENTS AS SET FORTH BY "NFPA 13", ITS ]S-[ TEE MJ x FL AMENDMENTS, AND LOCAL REQUIREMENTS, INCLUDING BUT NOT LIMITED TO Q K GATE VALVE MJ x FL ACQUISITION OF ALL PERMITS. J �C GATE VALVE MJ N CHECK VALVE w FIRE DEPARTMENT CONNECTION GENERAL NOTES: Ak FIRE HYDRANT 1. SEE SHEETS C7.3, C7.5, C7.6, AND C7.7 FOR STANDARD WATER NOTES AND 0 IRRIGATION CONTROL VALVE DETAILS. 0 WATER METER 2. FILL AND COMPACT THE ROADWAY PRISM TO FINISH GRADE PRIOR TO EXCAVATION ® FOR INSTALLATION OF NEW WATERMAIN. POST INDICATOR VALVE 3. ALL BENDS SHALL HAVE CONCRETE BLOCKING PER C7.6 C7.6 'AND C7.6 G GAS LINE P ELECTRICAL LINE LO 4. TRENCHING, BEDDING, BACKFILL, AND PAVEMENT PATCHING FOR THE GAS LINE r- W WATER LINE SHALL BE INCLUDED IN THE SITE CONTRACTOR'S BASE BID. THE GAS LINE SHALL BE CV I IRRIGATION PER RECORD DRAWING INSTALLED BY PSE. O O F FIRE SERVICE LINE 4 O X X FENCE 5. TRENCHING SHALL BE CONSTRUCTED PER DETAIL C7.10 C9 CONCRETE 6. ALL WATER MAINS SHALL HAVE MINIMUM 3 FEET COVER. ASPHALT 7. PROVIDE TWO-WAY CLEANOUTS AT CONNECTIONS TO BUILDING PIPING PER DETAIL 3 - - PROPERTY/RIGHT-OF-WAY LINE C7.2 CONSTRUCTION RECORD DRAWINGS VERTIA HORZONTnL�NADDi983�T991 1,1 U CITY OF R E N TO N DATUM Planning/Building/Public Works Dept. S BIT APPROVED FOR CONSTRUCTION SUBJECT TO ERRORS AND OMISSIONS I BY: DATE: BY: DATE: BY: DATE: BY: DATE: SARTORI ELEMENTARY SCHOOL RENTON SCHOOL DISTRICT OVERALL UTILITY PLAN 05/04/2017 FIELDBOOK: PAGE: DRAWING N0: C4.0 SHEET:OF: 14 43 R-393014 S-393001 W-393001