HomeMy WebLinkAboutR-417813700
N
v
0
Q
W
J
O
U)
NW 1/4 OF THE NW 1/4 AND THE NE 1/4 OF THE NW 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.
d Vo C,
NEW SERVICE BREAKER SCHEDULE
AT HARRINGTON AVE HE & NE IITH ST
CIRCUIT
BREAKER
CONTACTOR
MAIN
2P-100 AMP
---
ILLUM A
2P-20 AMP
30 AMP
ILLUM B
2P-20 AMP
30 AMP
ILLUMINATION WIRING SCHEDULE
QRACEWAY
CONDUIT
SIZE
ILLUM.
XB
SERVICE
#2
EQUIP.
GRND.
PULL
WIRE
NO.
1
2" SCH40 PVC
2
1
2" SCH40 PVC
4
1
2
2" SCH40 PVC SPARE
1
3
2" SCHSO PVC
4
1
4
3" SCHSO PVC
3
5
2" SCHSO PVC
2
1
6
2" SCH40 PVC
4
1
7
EX 2" xx
2
8
T SCH40 PVC SPARE
1
' EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE
LARGEST WIRE SIZE IN THE CONDUIT.
**OTHER EXISTING CONDUCTORS MAY BE PRESENT IN EXISTING CONDUIT
RUN.
I 1 19 1 1
CO
O N NEW R W I EX R/W
Q
= W JEFF�AVE NE W
W In ss ss ss s SS
Z
W _
Ef R/W a EX R W
SITE
ILLUMINATION CONSTRUCTION NOTES
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 116.1. FURNISH AND INSTALL NEW
NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER
ILLUMINATION POLE SCHEDULE, SHEET IL-4, AND PER CITY OF RENTON STD PLANS 116.1, 116.2, 119,
120 & J013. APPLY DECAL NUMBERING WITH CDR POLE ID PER THE ILLUMINATION POLE SCHEDULE C
AND CITY OF RENTON STANDARD DETAIL 121.
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 117.1. FURNISH AND INSTALL NEW
ARTERIAL STREET DECORATIVE LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION
POLE SCHEDULE, SHEET IL-4, AND PER CITY OF RENTON STD PLANS 117.1, 117.3, 119, 120 &
JI APPLY DECAL NUMBERING WITH CDR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY
OF RENTON STANDARD DETAIL 121.
O3 CONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STD PLAN 126.1. FOUNDATION SHALL
BE ADJACENT TO AND FLUSH WITH SIDEWALK. FURNISH AND INSTALL SERVICE CABINET PER CITY OF
RENTON STD PLAN 122.1 &122.2. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL
BE VERIFIED BY CITY OF RENTON TRANSPORTATION MAINTENANCE MANAGER, 425-430-7423, PRIOR TO
INSTALLATION OF CONDUITS.
OTHE POWER SOURCE LOCATION WAS NOT KNOW AT THE TIME OF PLAN PREPARATION. THE
CONTRACTOR SHALL COORDINATE WITH PSE TO IDENTIFY A LOCATION FOR 1201240 VOLT SINGLE
PHASE POWER SOURCE CONNECTION INCLUDING COMPLETING ALL FORMS/APPLICATIONS AND PAYMENT
OF ALL ASSOCIATED FEES. THE CONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO THE
POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE SHALL
MAKE FINAL CONNECTION TO THE POWER SOURCE. THE CONTRACTOR SHALL ASSUME 500' FEET OF
TRENCHING TO CONNECT TO POWER SOURCE FOR BIDDING PURPOSES.
O EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. PROTECT DURING CONSTRUCTION.
OREMOVE EXISTING STREET LIGHT POLE & FOUNDATION TO MINIMUM 24" BELOW SURFACE GRADE. FILL
AND COMPACT VOID.
O7 EXISTING DAVIT STREET LIGHT POLE TO REMAIN. PROTECT DURING CONSTRUCTION.
O8 EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. PROTECT DURING CONSTRUCTION
OINTERCEPT AND EXTEND EXISTING CONDUIT TO NEW JUNCTION BOX.
f0 EXTEND NEW ILLUMINATION CONDUCTORS TO EXISTING JUNCTION BOX. SPLICE NEW ILLUMINATION
CONDUCTORS TO EXISTING CONDUCTORS IN EXISTING JUNCTION BOX WITH CITY APPROVED SPLICE KIT.
i7 EXISTING ARTERIAL STREET/PEDESTRIAN DECORATIVE LUMINAIRE POLE TO REMAIN. PROTECT DURING
CONSTRUCTION.
12 EXISTING DAVIT STREET LIGHT POLE TO REMAIN. REPLACE EXISTING LUMINAIRE WITH NEW LED FIXTURE
PER ILLUMINATION POLE SCHEDULE, SHEET IL-04.
13 CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 117.1. RELOCATE EXISTING ARTERIAL
STREET DECORATIVE LUMINAIRE POLE AND LED LUMINAIRE TO NEW LOCATION. INSTALL RELOCATED
POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL-4, AND PER CITY
I
1
MATCH LINE STA 23+70 —
SEE SHEET IL-03
1
CIVIL CONSTRUCTION PERMIT
2
CIVIL CONSTRUCTION
PERMIT
RESUBMITTAL
3
CIVIL CONSTRUCTION
PERMIT
RESUBMITTAL
4
CML CONSTRUCTION
PERMIT
RESUBMITTAL
NO I REVISION
n
BY I DATE I APPR
1
BVL
Mo MS
SITE
1
St
ie 2 P
a\,yf. 52125
t^s ;,ISTEa;'G
S70NAL F�
03-71 2022
SAS NOTED "'4 19°'�199
III DATUM
swf Kraaxuv
O
ti
SITE
15 60
0 30 90
SCALE IN FEET
LEGEND
EX
NEW
DESCRIPTION
Z
917
JUNCTION BOX TYPE 1,2
0-0 *_0
ROADWAY LUMINAIRE POLE
;X
PEDESTRIAN LUMINAIRE POLE
4
UTILITY POLE
Y�
UTILITY POLE MOUNTED
LUMINAIRE
— — —
— --
CONDUIT/CONDUCTOR
®
ELECTRICAL SERVICE CABINET
OCONSTRUCTION
NOTE
O
LUMINAIRE POLE CALLOUT
AWIRE
NOTE
1 TENW
Transportation Engineering NorthWest
Tansporatbn Planning I IMsign I Traftic miI Operations
114W SE 8th St, Suite ZI Belewe,WA981MM I OM I4251889-6747
Project Contact: Grant Lewis
CITY OF
' RENTON
Plonning/Building/Public Works Dept.
'S0 p'S
SAP
f O�S����
R-4178137 T-417807
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING TRANSPORTATION OPERATION
msippo 04/07/2022 CBarnes 04/08/2022 lR
SOLERA oa/11 /202
2842 NE SUNSET BLVD
RENTON, WA 98056
ILLUMINATION PLAN L—� 1
137 144
0
N
O
O
O
T
N
A
M
AN
A
O
N
Q
J
rev