HomeMy WebLinkAboutR-417813800
N
v
O
n
i
Q
W
J
0
U)
a
sG—
m I DR�WY_
NI
4PROPOSED SUNSET SHELL
a C-STORE REDEVELOPMENT
b SHOWN FOR REFERENCE ONLY
LI�
00
0 X R/W
3 J 0
10
0-------
I _
-w —w w w w
0+� 1+00
F .
w W -w -w
wW
NW 1/4 OF THE NW 1/4 AND THE NE 1/4 OF THE NW 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.
ILLUMINATION WIRING SCHEDULE
QRACEWAY
CONDUIT
SIZE
ILLUM.
#B
SERVICE
#2
EQUIP.
GRND.
PULL
WIRE
NO.
1
2" SCH40 PVC
2
1
2" SCH40 PVC
4
1
2
2" SCH40 PVC SPARE
1
3
2" SCHBO PVC
4
1
4
3" SCHBO PVC
3
5
2" SCHBO PVC
2
1
6
2" SCH40 PVC
4
1
7
EX 2" **
2
1
8
2" SCH40 PVC SPARE
1
* EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE
LARGEST WIRE SIZE IN THE CONDUIT.
**OTHER EXISTING CONDUCTORS MAY BE PRESENT IN EXISTING CONDUIT
RUN.
'I Am 1�
JEFFERS 4O
00
SITE
NE SUNSET BLVD
CIVIL CONSTRUCTION PERMIT
CIVIL CONSTRUCTION PERMIT RESUBMITTAL
NO REVISION
7
BY I DATE I APPR
EX R/W
O
6 O MO
-F
LO J
^w
2 C w=
z�
UNc
I_
N y
�mt �
ZZ
s ss sS��A •'EaG�
—w—w 03-71 2022
�z mkvrn SAS NOTED �na'�m,
cxeo�L/GRL�
mME o BVL IEMSII
DATUM
°�'P swe.a NMY
ILLUMINATION CONSTRUCTION NOTES
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 116.1. FURNISH AND INSTALL NEW
NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER
ILLUMINATION POLE SCHEDULE, SHEET IL-4, AND PER CITY OF RENTON STD PLANS 116.1, 116.2, 119,
120 & J013. APPLY DECAL NUMBERING WITH CDR POLE ID PER THE ILLUMINATION POLE SCHEDULE
AND CITY OF RENTON STANDARD DETAIL 121.
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 117.1. FURNISH AND INSTALL NEW
ARTERIAL STREET DECORATIVE LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION
POLE SCHEDULE, SHEET IL-4, AND PER CITY OF RENTON STD PLANS 117.1, 117.3, 119, 120 &
J013. APPLY DECAL NUMBERING WITH CDR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY
OF RENTON STANDARD DETAIL 121.
O3 CONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STD PLAN 126.1. FOUNDATION SHALL
BE ADJACENT TO AND FLUSH WITH SIDEWALK. FURNISH AND INSTALL SERVICE CABINET PER CITY OF
RENTON STD PLAN 122.1 &122.2. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL
BE VERIFIED BY CITY OF RENTON TRANSPORTATION MAINTENANCE MANAGER, 425-430-7423, PRIOR TO
INSTALLATION OF CONDUITS.
OTHE POWER SOURCE LOCATION WAS NOT KNOW AT THE TIME OF PLAN PREPARATION. THE
CONTRACTOR SHALL COORDINATE WITH PSE TO IDENTIFY A LOCATION FOR 1201240 VOLT SINGLE
PHASE POWER SOURCE CONNECTION INCLUDING COMPLETING ALL FORMS/APPLICATIONS AND PAYMENT
OF ALL ASSOCIATED FEES. THE CONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO THE
POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE SHALL
MAKE FINAL CONNECTION TO THE POWER SOURCE. THE CONTRACTOR SHALL ASSUME 500' FEET OF
TRENCHING TO CONNECT TO POWER SOURCE FOR BIDDING PURPOSES.
OEXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. PROTECT DURING CONSTRUCTION.
OREMOVE EXISTING STREET LIGHT POLE & FOUNDATION TO MINIMUM 24" BELOW SURFACE GRADE. FILL
AND COMPACT VOID.
O EXISTING DAVIT STREET LIGHT POLE TO REMAIN. PROTECT DURING CONSTRUCTION.
O EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. PROTECT DURING CONSTRUCTION
O INTERCEPT AND EXTEND EXISTING CONDUIT TO NEW JUNCTION BOX.
ip EXTEND NEW ILLUMINATION CONDUCTORS TO EXISTING JUNCTION BOX. SPLICE NEW ILLUMINATION
CONDUCTORS TO EXISTING CONDUCTORS IN EXISTING JUNCTION BOX WITH CITY APPROVED SPLICE KIT.
11 EXISTING ARTERIAL STREET/PEDESTRIAN DECORATIVE LUMINAIRE POLE TO REMAIN. PROTECT DURING
CONSTRUCTION.
12 EXISTING DAVIT STREET LIGHT POLE TO REMAIN. REPLACE EXISTING LUMINAIRE WITH NEW LED FIXTURE
PER ILLUMINATION POLE SCHEDULE, SHEET IL-04.
13 CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 117.1. RELOCATE EXISTING ARTERIAL
STREET DECORATIVE LUMINAIRE POLE AND LED LUMINAIRE TO NEW LOCATION. INSTALL RELOCATED
POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL-4, AND PER CITY
OF RENTON STD PLANS 117.1, 117.3, 119, 120, AND J013.
%TENW
Transportation Engineering NorthWest
Tansporatbn Planning I IMsign I TraHiclmpactd Operatb%
114W SE 8th St, Suite ZI Belewe, WA981Ak I Office 1425! 589-6747
Project Contact: Grant Lewis
CITY OF
' RENTON
Plonning/Building/Public Works Dept.
15 60
0 30 90
SCALE IN FEET
LEGEND
19
NEW
DESCRIPTION
El
9O
JUNCTION BOX TYPE 1,2
ROADWAY LUMINAIRE POLE
Y
PEDESTRIAN LUMINAIRE POLE
O
UTILITY POLE
UTILITY POLE MOUNTED
LUMINAIRE
— — —
---
CONDUIT/CONDUCTOR
®
ELECTRICAL SERVICE CABINET
O
CONSTRUCTION NOTE
O
LUMINAIRE POLE CALLOUT
ZL
WIRE NOTE
R-4178138 T-417808
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING TRANSPORTATION OPERATION 101
msippo 04/07/2022 '� CBarnes 04/08/2022
SOLERA 733/11 /zoz
2842 NE SUNSET BLVD
RENTON, WA 98056
ILLUMINATION PLAN L—O2
�7138 144
O
N
O
O
O
T
N
IF
M
FBI
Fft1
O
N
Q
J
M
M
M
O
O
O
00
T
a