HomeMy WebLinkAboutR-4178139NW 1/4 OF THE NW 1/4 AND THE NE 1/4 OF THE NW 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.
co co
N n
T
O o
W
H
Q
W
J
O
U)
A
ILLUMINATION WIRING SCHEDULE
0
RACEWAY
CONDUIT
SIZE
ILLUM.
#8
SERVICE
X2
EQUIP.
GRND.
PULL
WIRE
No.
1
2" SCH40 PVC
2
1
2" SCH40 PVC
4
1
2
2" SCH40 PVC SPARE
1
3
2" SCHSO PVC
4
1
4
3" SCHSO PVC
3
5
2" SCHSO PVC
2
1
6
2" SCH40 PVC
4
1
7
EX 2" "
2
8
2" SCH40 PVC SPARE
1
' EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE
LARGEST WIRE SIZE IN THE CONDUIT.
"OTHER EXISTING CONDUCTORS MAY BE PRESENT IN EXISTING CONDUIT
RUN.
R
■ 1O
MATCH LINE STA 23+70 —
SEE SHEET IL-01
ILLUMINATION CONSTRUCTION NOTES
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 116.1. FURNISH AND INSTALL NEW
NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER
ILLUMINATION POLE SCHEDULE, SHEET IL-4, AND PER CITY OF RENTON STD PLANS 116.1, 116.2, 119,
120 & J013. APPLY DECAL NUMBERING WITH CDR POLE ID PER THE ILLUMINATION POLE SCHEDULE
AND CITY OF RENTON STANDARD DETAIL 121.
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 117.1. FURNISH AND INSTALL NEW
ARTERIAL STREET DECORATIVE LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION
POLE SCHEDULE, SHEET IL-4, AND PER CITY OF RENTON STD PLANS 117.1, 117.3, 119, 120 &
J013. APPLY DECAL NUMBERING WITH CDR POLE ID PER THE ILLUMINATION POLE SCHEDULE AND CITY
OF RENTON STANDARD DETAIL 121.
O
OTHE POWER SOURCE LOCATION WAS NOT KNOW AT THE TIME OF PLAN PREPARATION. THE
CONTRACTOR SHALL COORDINATE WITH PSE TO IDENTIFY A LOCATION FOR 1201240 VOLT SINGLE
PHASE POWER SOURCE CONNECTION INCLUDING COMPLETING ALL FORMS/APPLICATIONS AND PAYMENT
OF ALL ASSOCIATED FEES. THE CONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO THE
POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE SHALL
MAKE FINAL CONNECTION TO THE POWER SOURCE. THE CONTRACTOR SHALL ASSUME 500' FEET OF
TRENCHING TO CONNECT TO POWER SOURCE FOR BIDDING PURPOSES.
O EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. PROTECT DURING CONSTRUCTION.
OREMOVE EXISTING STREET LIGHT POLE & FOUNDATION TO MINIMUM 24" BELOW SURFACE GRADE. FILL
AND COMPACT VOID.
O7 EXISTING DAVIT STREET LIGHT POLE TO REMAIN. PROTECT DURING CONSTRUCTION.
8O EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. PROTECT DURING CONSTRUCTION
O INTERCEPT AND EXTEND EXISTING CONDUIT TO NEW JUNCTION BOX.
ip EXTEND NEW ILLUMINATION CONDUCTORS TO EXISTING JUNCTION BOX. SPLICE NEW ILLUMINATION
CONDUCTORS TO EXISTING CONDUCTORS IN EXISTING JUNCTION BOX WITH CITY APPROVED SPLICE KIT.
11 EXISTING ARTERIAL STREET/PEDESTRIAN DECORATIVE LUMINAIRE POLE TO REMAIN. PROTECT DURING
CONSTRUCTION.
12 EXISTING DAVIT STREET LIGHT POLE TO REMAIN. REPLACE EXISTING LUMINAIRE WITH NEW LED FIXTURE
PER ILLUMINATION POLE SCHEDULE, SHEET IL-04.
13 CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 117.1. RELOCATE EXISTING ARTERIAL
STREET DECORATIVE LUMINAIRE POLE AND LED LUMINAIRE TO NEW LOCATION. INSTALL RELOCATED
POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL-4, AND PER CITY
OF RENTON STD PLANS 117.11 117.3, 119, 120, AND JI
ti 3
x Z I SITE
I
O
I
I ; O
I III O
a
+00
CIVIL CONSTRUCTION PERMIT
CIVIL CONSTRUCTION PERMIT RESUBMITTAL
LJ N0. REVISION BY DATE APPR
EX
NE SUNSET BLVD 10+00
V.
ie 2 P
V]N Iv
a\ -P 53125 O i2�
STONAL F�
03-11 2022
z�mmn S AS NOTED
0
cxeo�L/GRL�
mME BVL III
DATUM
°PDWM uc swe.a NMY
M-
/
I
'51 �1��
3
�&��S \
�EX. R1W
1 TENW
Transportation Engineering NorthWest
Tansporatbn Planning I IMsign I Traftic miI Operations
114W SE 8th St, Suite ZI Belewe, WA981MM 1 01fice Id25t 889-6747
Project Contact: Grant Lewis
CITY OF
' RENTON
Plonning/Building/Public Works Dept.
Z
tizee`e�
44111
15 60
0 30 90
SCALE IN FEET
LEGEND
EX
NEW
DESCRIPTION
®
90
JUNCTION BOX TYPE 1,2
ROADWAY LUMINAIRE POLE
Y
PEDESTRIAN LUMINAIRE POLE
UTILITY POLE
t=�
UTILITY POLE MOUNTED
LUMINAIRE
— — —
-- —
CONDUIT/CONDUCTOR
®
ELECTRICAL SERVICE CABINET
O
CONSTRUCTION NOTE
OLUMINAIRE
POLE CALLOUT
QWIRE
NOTE
R-4178139 T-417809
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
revewrment enulneenlnu TRANSPORTATION OPERATION
msippo 04/07/2022 CBarnes 04/08/2022
SOLERA oa/11 /202
2842 NE SUNSET BLVD
RENTON, WA 98056
ILLUMINATION PLAN AIL-
03
�m139 144
O
N
O
O
O
T
N
A
M
FBI
Fft1
O
N
Q
J
M
M
M
O
O
O
00
a