NW 1/4 OF THE NW 1/4 AND THE NE 1/4 OF THE NW 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.
-aQa %j o °Lire
o �9sP spvs F __34> !y F
s
N32'13'36E 686.0�'
t
v.
S
1 '
GRADING
I 0 C4.20 ENLARGEMENT,
av SEE NOTE 1
1 \ \
' o
F So
11+00 '�°� r 12+00
0
+I VIC, r
I�
I I
0
LEGEND:
— — PROPERTY LINE/ROW LINE
ROW CENTERLINE
RETAINING WALL
EXISTING GRADE CONTOUR
—360— MAJOR FINISHED GRADE CONTOUR
362 MINOR FINISHED GRADE CONTOUR
EXISTING TREE TO BE PROTECTED
iy � >,t E.9: I � � t•L ! [r➢� Y•1;� d•7 , u I , u Icu [�1 J
FUTURE BLOCK C
�Y — —xYr�V v�
13+00
^' ` •P • II
NOTES:
1. REFER TO GRADING ENLARGEMENTS FOR CURVE DATA.
2. ALL EARTHWORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT
GEOTECHNICAL REPORT PREPARED BY EARTH SOLUTIONS NW, UDC, DATED JANUARY 29,
2018.
3. SUBGRADES SHALL BE OBSERVED AND TESTED BY THE PROJECT GEOTECHNICAL
CONSULTANT PRIOR TO PLACEMENT OF FILL, BASE COURSES, OR FOUNDATION FORMS AND
REINFORCING.
0 10 20 40
1 inch = 20 het
Call 811
• two business days
before you dig
N0.
14+00
JEFF SON AVENUE
• •
L7,-J MIXED USE
BUILDING B
SEE SHEET C4.03 FOR CONTINUATION
4. STRUCTURAL FILL SHALL BE PLACED IN UNIFORM LAYERS NOT EXCEEDING 12 INCHES IN
THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF THE SOIL MAXIMUM DRY DENSITY
ACCORDING TO ASTM D-695 (MODIFIED PROCTOR). THE PROJECT GEOTECHNICAL ENGINEER
SHALL INSPECT AND APPROVE THE PREPARED SUBGRADE PRIOR TO FILL PLACEMENT.
5. ON —SITE SOILS MAY BE USED FOR STRUCTURAL FILL ONLY IF VISUALLY INSPECTED AND
APPROVED BY THE PROJECT GEOTECHNICAL ENGINEER. ON —SITE SOILS SHALL BE FREE OF
ORGANIC MATERIAL AND COMPACTED PER THE REQUIREMENTS OF NOTE 3 ABOVE.
6. ROADWAY CONTOURS ARE SHOWN HERE FOR REFERENCE. SEE ROAD AND STORM
DRAINAGE PLANS FOR ROAD GRADING AND SECTIONS.
CIVIL CONSTRUCTION PERMIT
CIVIL CONSTRUCTION PERMIT RESUBM17AF
CIVIL CONSTRUCTION PERMIT RMUBMITTAL
CIVIL CONSTRUCTION PERMIT RESUBMITTAL
REVISION
Z
Ln
O
co
O
O
O
o
O
N
Q
�
J
z
O
U
K
O
O
Y
U
W
W
Ch
ti
M
W
O
N
00
00
T
a
15+00 16+00
• it. x x
7. REFER TO LANDSCAPE PLANS FOR WALL TYPES AND MATERIALS.
8. BUILDING FINISH FLOOR ELEVATIONS ARE SHOWN FOR REFERENCE ONLY. SEE ARCHITECT'S
PLANS FOR FINAL ELEVATIONS.
9. CONTRACTOR SHALL VERIFY EXISTING GRADES AND NOTIFY ENGINEER OF ANY R-417820
DISCREPANCY PRIOR TO CONSTRUCTION.
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
l DEVELOPMENT ENGINEERING O
msippo 04/07/2022
16015th Avenue, Suite 1600
Seattle, WA98101
3N.633.5822
(� www.kpff.cam
TJP 09/03/21 LEE ZLN AS NOTED P1 MEN I1BCS/Im' CITY OF SOLERA
TJP 01/12/22 JSF owu MDR/TJP , °° K
RENTON 2842 NE SUNSET BLVD
rJP Oyu/22 JSF °"'"" KSA/JEP �� RENTON, WA 98056
DATUM
`"F°'NNE Planning/Building/Public Works Dept. C4,CC
BY DATE APPR USE SCEE �C�.«.. GRADING PLAN - BLOCK C s"' 20 4,