HomeMy WebLinkAboutR-417832NW 1/4 OF THE NW 1/4 AND THE NE 1/4 OF THE NW 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.
00
Hit
I
O
V
,
W
F_
Q
W
J
O
U)
rA03
o
W
W ]—
N —
1.161
N
/� �S
p: P p
v p
5. TC-366.07 P o
.36 BC 365.57 p
R
/
D/ ..
�O o /
P P —
MIXED USE
BUILDING A 366�'
v v
IENT m,
i TAml
s� • - �I�a ��
1I
a
���� ��1r.=13&iH1��16Se:iliFSItAI�
w w wTw w w w
J TIC 366.28 (ME
BC 365.78 (ME)
TC 366.31
h BC 365.81
8+00
—Ss Ss SS Ss Ss SS sss Ss—
NE SUNSET BOULEVARD (SR 900)
t
CNIL CONSTRUCTION
PERMIT
2
CIVIL
CONSTRUCTION
PERMIT
RESUBM17AL
3
CIVIL
CONSTRUCTION
PERMIT
RMUBMITTAL
4
1
CIVIL
CONSTRUCTION
PERMIT
RESUBMITTAL
NO. I REVISION
BY I DATE I APPR
7µi7
TC 366.32 (M
BC 365.82 (ME)
9+00�
y'pee
,p s2
S
v
v°
0
0
v v
p b
0
p
p
z
o
�
t=
z
F
—ss Ss.
o p
z
o
�
M
��
V
Y 6 lq3ff
T4R� p4 N�•gA`o�N
gay 36015th Avenue, Suite 1600
0 5 10 20 o�RACI3Tee�`{Q� Seattle, WA 98101
93(ONAL W6t' 3W.633.5822
1 inch = 10 feel 3/11/2022 www.kpff.com
HAND III
M"•AS NOTED a4°",L.HAD III °°' CITY OF
' FENTON
AT l aFOP
SZ11
DATUM
� caw,w Planning/Building/Public Works Dept.
IF NOT ONE INCH
NOTES:
1.
ALL EARTHWORK SHALL BE PERFORMED IN ACCORDANCE WITH
THE PROJECT GEOTECHNICAL REPORT PREPARED BY EARTH
SOLUTIONS NW, LLC, DATED JANUARY 29, 2018.
2.
SUBGRADES SHALL BE OBSERVED AND TESTED BY THE
p
PROJECT GEOTECHNICAL CONSULTANT PRIOR TO PLACEMENT OF
CVO
FILL, BASE COURSES, OR FOUNDATION FORMS AND
REINFORCING.
r
p
O
3.
STRUCTURAL FILL SHALL BE PLACED IN UNIFORM LAYERS NOT
r
EXCEEDING 12 INCHES IN THICKNESS AND COMPACTED TO A
N
MINIMUM OF 95% OF THE SOIL MAXIMUM DRY DENSITY
L%
ACCORDING TO ASTM D-695 (MODIFIED PROCTOR). THE
PROJECT GEOTECHNICAL ENGINEER SHALL INSPECT AND
APPROVE THE PREPARED SUBGRADE PRIOR TO FILL PLACEMENT.
4.
ON -SITE SOILS MAY BE USED FOR STRUCTURAL FILL ONLY IF
VISUALLY INSPECTED AND APPROVED BY THE PROJECT
GEOTECHNICAL ENGINEER. ON -SITE SOILS SHALL BE FREE OF
ORGANIC MATERIAL AND COMPACTED PER THE REQUIREMENTS
OF NOTE 3 ABOVE.
to
5.
ROADWAY CONTOURS ARE SHOWN HERE FOR REFERENCE. SEE
M
ROAD AND STORM DRAINAGE PLANS FOR ROAD GRADING AND
p
SECTIONS.
O
O
6.
REFER TO LANDSCAPE PLANS FOR WALL TYPES AND
O
MATERIALS.
CV
Q
�
7.
BUILDING FINISH FLOOR ELEVATIONS ARE SHOWN FOR
J
REFERENCE ONLY. SEE ARCHITECT'S PLANS FOR FINAL
ELEVATIONS.
9.
CONTRACTOR SHALL VERIFY EXISTING GRADES AND NOTIFY
ENGINEER OF ANY DISCREPANCY PRIOR TO CONSTRUCTION.
10.
REFER TO GRADING ENLARGEMENTS FOR CURVE DATA.
CM
LEGEND:
m
M
O
- - PROPERTY LINE/ROW LINE
pp
00
- ROW CENTERLINE
v CONCRETE WALL
d
EXISTING GRADE CONTOUR
—360— MAJOR FINISHED GRADE CONTOUR
—362— MINOR FINISHED GRADE CONTOUR
EXISTING TREE TO BE PROTECTED
R-417832