Loading...
HomeMy WebLinkAboutR-4178609 Vvi sq � v sso , p W 8" IE 01UP 30+00 £ Q Q' w W +._ + o I FUTURE + 2 F- Z e • SEE SHEET C5.13 FOR CONTINUATION 365 360 355 350 1 345 1 340 1 335 NW 1/4 OF THE NW 1/4 AND THE NE 1/4 OF THE NW 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M. G V6 a 9 _ sl ce /21 � --- -- .,� C 1 - - �'-asa---- CB /22 4'BFNc, ., G MNGTON PL NE r SD- 32+00 w w w- } 26 LW 6" SD)"' YD - O 10'.BI) SD SD- 33+00 w w wig rr /`--VU CB #22A RIM=352.10 TO BE CLEARED AND GRADED AND STABILIZED ONLY 8" IE OUT=348.43 OF KEY PLAN NITS a NOTES: LEGEND: EX SDMH TYPE -60" SOLID LID STA 33+53.63, 8.93' .L.... 8 RIM=354.77 EXISTING GRADE AT + M + + 12" IE IN=342.62 (SW) OF ROAD/SAWCUT N o, AV ^ 36 IE OUT=342.64 (E) 39 LF 12" SO ®0.45% - z . "'i "' n '�" 36' IE OUT-342.64 (W),,,, _. STA. 31+30.34 STA. 31+40.00 - :PROPOSED GRADE _ a CIO� II w c N w n.............MTYPE J ---- STA. 30+50.64 STA. 30+60.00 STA. 31+00.00 EL=351.36 EL=351.49 AT FLOW LINE f N -- _-_- - EL=351.16 EL=351.12 : EL=351.12. _ - - - _ FOAM BLOCKING--- ----.,�, 2" WM XING AN 1' UTIL SEP--- 42" VM-XING..... .......... .... TA. 3�STA. 30+43.26 2" W1A RING EL=344.08 31+12.71 PROVIDE ETHAFOAM BLOCKING ./-STA. EL=347.47 SO ® 0.45%FOR LESS THAN 1' UTIL SEP 1F-12" SO 01.41XEXISTING SDMH TYPE -48" 2 PROVDE ETHAFOAM BLOCKINGSOLID LID 1 E P-4 " FOR LESS THAN 1' UTIL SEP m 2 CB 12 TYPE 2_ " STA. 30+38.39, 7,83' LT SOLID UD 144 LF 12" SO 0 0.45% ,;,u� SOLID LID 2-4 " .....RIM=350.59 ._ STA. ..30+85.27,-8.01' LT d n STA. 32+29.73, 8.34'-LT - -- SOLID UD --- -- -- --- 12 IE IN=347.35 (S) RIM=351.15 `�^ w RIM=352.58 STA. 32+70.21, 8.51' LT EX)12 IE IN=345.38 (W) (EX)12" IE IN=344.84 (SW) (EX)12" IE IN=344.18 (SW) RIM=353.07 EX)6" IE IN=345.38 (SE) 8" IE IN=344.84 (SE) 8" IE IN=345.86 (SE) - - 12" IE IN=344.00 (SW) - - EX)12" IE OUT=345.05 (NE) .;(EX)12" IE 00T=344.84 (NE) - - '.. EX 2" IE''. OUT=344.18 NE 12"'. IE OUT=343.80 NE - - Q, OJ no O a no OJ O < [O n O M [O O M O M M M M M M M M M 30+00 30+40 30+80 31+20 31+60 32+00 32+40 32+80 33+20 33+60 KEY TOP UTILITY CIA DEPTH TO TOP UTIL APP. IE BOT UTILITY CIA DEPTH TO BOT UTIL APP. IE VERT' CLEARANCE 10 STORM 12" 44" 345.08 1 WATER 1 6" 50" 344.08 0.50' O STORM 8" 70" 345.88 1 WATER 12" 76" 344.38 0.50' 03 WATER 12" 61" 347.46 1 STORM 8" 67" 346.29 0,50' Call 811 • twD business days before you dig N0. CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBM17AL CIVIL CONSTRUCTION PERMIT RMUBMITTAL CIVIL CONSTRUCTION PERMIT RESUBMITTAL REVISION BY I DATE I APPR 1. ALL CATCH BASINS WITHIN THE RIGHT - - PROPERTY LINE/ROW LINE OF WAY SHALL BE CONSTRUCTED WITH VANED GRATE LOCKING LID, UNLESS - - ROW CENTERLINE NOTED OTHERWISE. ASPHALT ROADSIDE INFILTRATING BIORETENTION PLANTER PER CITY OF RENTON STANDARD DETAIL 262.00 ON SHEET o P - CONCRETE C5.50 CONSTRUCTED WITH THROUGH -CURB INLET AT UPSTREAM SIDE OF PLANTER CONNECT OVERFLOW CURB TO CONVEYANCE IN ROW. CONTRACTOR SHALL PROTECT BIORETENTION AREA -360- MAJOR FINISHED GRADE CONTOUR DURING CONSTRUCTION TO PREVENT 365 COMPACTION OR SILTATION. -362- MINOR FINISHED GRADE CONTOUR O3 ON -SITE BIORETENTION PER CITY OF -3101- STORM DRAIN LINE RENTON STANDARD DETAIL 262.20 ON • ® CATCH BASIN $a Sb 360 SHEET C5.52. CONTRACTOR SHALL C5.50 C5.50 PROTECT BIORETENTION AREA DURING CONSTRUCTION TO PREVENT CLEANOUT 1 5 COMPACTION OR SILTATION. C5.52 ❑1 BIORETENTION ID 355 ® CONNECT TO EXISTING STORM STRUCTURE. CONTRACTOR SHALL CURB INLET 10 CONFIRM LOCATION AND ELEVATION OF C5.51 STRUCTURE AND CONNECTED PIPES AND NOTIFY ENGINEER OF ANY BIOPOD 350 DISCREPANCIES. 5. PLACE ETHAFOAM PAD BETWEEN PIPE CROSSINGS WITHIN LESS THAN 18" 345 CLEARANCE. 6. ALL STORM DRAINAGE PIPE 12" OR LARGER SHALL BE TYPE S, LINED CORRUGATED POLYETHYLENE (LCPE) 340 PER WSDOT STANDARD SPECIFICATIONS 9-05.19 UNLESS INDICATED OTHERWISE. DUCTILE IRON STORM DRAIN PIPE SHALL BE PER WSDOT STANDARD 335 SPECIFICATIONS 9-05.15. BIORETENTION BOTTOM BOTTOM OVERFLOW OUTLET CONNECTED CURB CURB NUMBER ® AREA (SF) ELEV. ELEV. IE TO INLET STA INLET ELEV. 22 90 351.42 351.59 346.92 EX. SD MAIN 31+95.34, 13.D0 RT 351.09 23 76 351.93 352.10 348.43 EX. SO MAIN 31+95,34' 13.00 RT 352.60 R-417860 �j IN COMPLIANCE WITH CITY OF RENTON STANDARDS 4�a of .A,ay�Edjq3ff SURFACE WATER UTILITY DEVELOPMENT ENGINEENING 0 0 JFarah04/01/2022 � msippo04/07/2022 O 1 inch = 20 R. I k Md7 36015th Avenue, Suite 1600 0 2.5 5 10 ISTBR `�Q. Seattle, WA98101 93tONAL W6c, 206.622.5611 1 Inch = 5 ft. VERT 3/11/2022 w mkpff.cam M". AS NOTED °" �"'°'°"'^"A CITY OF SOLERA RRI FENTON 2842 NE SUNSET BLVD °°®°"' RENTON, WA 98056 �� DATUM Planning/Binding/Public works Dept. GRADING AND STORM DRAINAGE C5.18 HARRINGTON PLACE NE PLAN AND PROFILE 60 1 s O N O O O N Z 1n O M O O O O N Q J M M M O O O _W Cc a