Loading...
HomeMy WebLinkAboutR-417875NW 1/4 OF THE NW 1/4 AND THE NE 1/4 OF THE NW 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M. Go Hit I O W 1— Q W J O C7 COVER PIPE CONNECTION TO END CAP WITH ADS GEOSYNTHETIGS 601T NON -WOVEN GEOTEXTILE FLEXSTORM PURE INSERT INLET MANIFOLD TO NON ISOLATOR ROLLS 2' SUMP INSPECTION & MAINTENANCE MC-3500 CHAMBER 12" (300 ITT) HDPE ACCESS PIPE REQUIRED USE FACTORY PRE -CORED END CAP PART: MC35001EPP24BC OR MC35001EPP24BW STEP 1) INSPECT ISOLATOR ROW FOR SEDIMENT A. ALL ISOLATOR ROWS A.1. REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW A.2. USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW THROUGH OUTLET PIPE i) MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRY ii) FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE A.3. IF SEDIMENT IS AT, OR ABOVE, 3" (80 Turn) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3. STEP 2) CLEAN OUT ISOLATOR ROW USING THE JETVAC PROCESS A. A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45" (1.1 m) OR MORE IS PREFERRED B. APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEAN C. VACUUM STRUCTURE SUMP AS REQUIRED STEP 3) REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS. STEP 4) INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM. NOTES Gcb111117N1III Inv LII ur AI oEOSYNTHETICS 315WTM WOVEN GEOTEXTILE BETWEEN FOUNDATION STONE AND CHAMBERS 8.25' (2.51 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS 1. INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUS OBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS. 2. CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY. MC-3500 ISOLATOR ROW DETAIL - MODIFIED Call 811 • twoC business days before you dig CIVIL CONSTRUCTION PERMIT CIVIL CONSTRUCTION PERMIT RESUBM17AL CIVIL CONSTRUCTION PERMIT RESUBMITTAL NO. I REVISION BY I DATE I APPR VALLEY 86.0" STIFFENING RIB CREST INSTALLED S7IFFENING CREST WEB RIB LOWER JOINT CORRUGATION 1 1 1 1 1 1 FOOT L UPPER JOINT CORRUGATION r/dyWdyWdyW�WW6T7W�WWdT! BUILD ROW IN THIS DIRECTION o 900„ ACTUAL LENGTH 45.0" 45.0° 22 2" 1 INSTALLED 1 i— 77.0" 75.0" NOMINAL CHAMBER SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH) 77.0" X 45.0" X 86.0" CHAMBER STORAGE 109.9 CUBIC FEET -{ I 25,7" F MINIMUM INSTALLED STORAGE* 178.9 CUBIC FEET WEIGHT 134 lbs. NOMINAL END CAP SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH) 75.0" X 45.0" X 22.2" L END CAP STORAGE 14.9 CUBIC FEET B MINIMUM INSTALLED STORAGE' 46.0 CUBIC FEET WEIGHT 49 Ibs. 'ASSUMES 12" STONE ABOVE, 9" STONE FOUNDATION AND BETWEEN CHAMBERS, 6" STONE PERIMETER IN FRONT OF END CAPS AND 40% STONE POROSITY G L T— OUTLET MANIFOLD STUBS AND INLET MANIFOLD STUBS CONNECTED TO ISOLATOR ROWS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B", INLET MANIFOLD STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T" PART # STUB C MC35001EPP12T 12" P-4—1 MC35001EPP128 — 1.35" MC-3500 TECHNICAL SPECIFICATIONS PER STORMTECH - MODIFIED BY KPFF AS NOTED a':mow NON I HD III � � DATUMIF NOT ONE INCH lcpff 16015th Avenue, Suite 1600 Seattle, WA 98101 205.622.5811 www.kpff.com = CITY OF ' FENTON viav Planning/Building/Public Works Dept. IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURFACE WATER UTILITY DEVELOPMENT ENGINEERING JFarah 04/01/2022 msippo 04/07/2022 SOLERA 2842 NE SUNSET BLVD " °°"' RENTON, WA 98056 "C5.61 STORMWATER CHAMBER SYSTEM DETAILS. O N O T O O , N Z Ln O M O O O O N Q J M M M 0 O O 00 MT LL