Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutItem7_171010_V1City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 2 of 19
8. EXHIBITS:
Exhibit
1:
Administrative Short Plat Report and Decision
Exhibit
2:
Neighborhood Detail
Exhibit
3:
Short Plat Layout
Exhibit
4:
Density Worksheet
Exhibit
5:
Tree Retention Worksheet
Exhibit
6:
Storm Drain Extension, 114th Ave SE
Exhibit
7:
Paving and Grading Plan
Exhibit
8:
Geotechnical Report, prepared by PanGEO Inc, dated June 24, 2014
Exhibit
9:
Technical Information Report, prepared by Springline Design LLC, dated July 7,
2014
Exhibit
10:
Topographic and Tree Survey
Exhibit
11:
Conceptual Landscape Plan
Exhibit
12:
Schools for attendance
Exhibit
13:
Schools bussing/walking commute information
Exhibit
14:
Public comments
Exhibit
15:
Advisory Notes / Review Comments
C. GENERAL INFORMATION:
Virtuoso Ventura 6 LLC
1. Owner(s) of Record: 14508 NE 20th St, #200; Bellevue, WA 98007
2. Zoning Designation: Residential 8 (R-8)
3. Comprehensive Plan Land Use Designation: Residential Single Family (RSF)
4. Existing Site Use: Single Family Residential
S. Neighborhood Characteristics: Single Family Residential
a. North: Single family residential uses in R-8 zone
b. East: Single family residential uses in R-8 zone
c. South: Single family residential uses in R-8 zone
d. West: Single family residential use in R-8 zone
6. Access: The site is a corner lot with access to both SE
162n, St and 114th Ave SE.
7. Site Area: 29,912 sf (0.69-acre)
D. HISTORICAL/BACKGROUND:
Action
Land Use File No.
Ordinance No.
Date
Comprehensive Plan
N/A
5099
11/01/2004
Zoning
N/A
5100
11/01/2004
Annexation, Benson Hill
N/A
5327
03/01/2008
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 3 of 19
E. PUBLIC SERVICES:
1. Utilities
aI Water: Water service is provided by Soos Creek Water and Sewer District.
bI Sewer: Water service is provided by Soos Creek Water and Sewer District.
c. Surface/Storm Water: There are no drainage improvements in SE 162"d St or 114`h Ave SE.
2. Streets: There are no street improvements fronting the site in 1141h Ave SE or SE 162°d St. Both
streets are classified as Residential Access roads.
3. Fire Protection: Service provided by City of Renton Fire Department.
F. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE:
1.
Chapter 2 Land Use
Districts
a. Section
4-2-020:
Purpose and Intent of Zoning Districts
b. Section
4-2-070:
Zoning Use Table
c. Section
4-2-110:
Residential Development Standards
d. Section
4-2-115:
Residential Design and Open Space Standards
2.
Chapter 4
Property
Development Standards
a. Section
4-4-070:
Landscaping Regulations
b. Section
4-4-080:
Parking, Loading, and Driveway Regulations
c. Section
4-4-130:
Tree Retention and Land Clearing Regulations
3.
Chapter 6
Streets and Utility Standards
a. Section
4-6-030:
Drainage (Surface Water) Standards
b. Section
4-6-060:
Street Standards
4.
Chapter 7
Subdivision Regulations
a. Section
4-7-070:
Detailed Procedures for Short Subdivisions
b. Section
4-7-120:
Compatibility with Existing Land Use and Plan —General Requirements
and Minimum Standards
c. Section
4-7-150:
Streets —General Requirements and Minimum Standards
d. Section
4-7-170:
Residential Lots —General Requirements and Minimum Standards
S.
Chapter 11
Definitions
G. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN:
1. Land Use Element: Residential Single Family (RSF) land use designation
2. Community Design Element
H. DEPARTMENT ANALYSIS:
1. Project Description/Background
The
applicant, Todd Karam, has requested
preliminary short plat approval fora
5-lot short plat.
The
applicant is proposing to subdivide a 0.69-acre
(29,912 sf) site within the
Benson
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014
Page 4 of 19
community of Renton, zoned Residential-8 (R-8) dwelling units per acre (du/ac) into five lots
(Exhibit 5),
City Council adopted Ordinance 5724 to provide interim zoning standards for the R-8 zone. The
legislation and interim standards became effective at the time of Council approval on
September 22"d1 2014. The Limelite Short Plat application was determined a complete
application on August 12, 2014, and therefore, is vested to the R-8 standards as were allowed
prior to the Council adoption of Ordinance 5724.
The area is designated Residential Single Family (RSF) in the City of Renton Comprehensive
Land Use Plan. The subject site has an existing single family home that is proposed to be
demolished. The subject site is a corner lot and is located at the southeast corner of SE 162°d St
and 114th Ave SE in the Cascade neighborhood area. The proposal for five lots would arrive at a
net density of 7.8 du/ac (Exhibit 4). Lot sizes for the residential parcels range from 8,834 sf to
5,039 sf. Access to the lots vary between the two abutting streets, with proposed curb cuts
from SE.162"d St for Lot 2 and Lot 1, curb cuts from 114th Ave SE for Lot 3, Lot 4, and Lot S
would have an easement across Lot 4 for a private driveway (Exhibit 7). Right-of-way
dedication is proposed at the northwest corner of the subject site for intersection radius, with
a triangular area dedicated of 48 sf (Exhibit 5).
Site improvements include grading, stormwater facilities, utility connections, and landscaping.
Off -site improvements would be required. There are no existing frontage improvements on
either street currently and street improvements are proposed that would include sidewalks
and planter strips. A storm drain extension is proposed in 114th Ave SE to the subject site. A
sanitary sewer main extension is proposed in SE 162°d St.
Site topography is generally flat, with approximately a 1% slope across the property (Exhibit
101. For existing trees, there are 12 trees with 6-inch diameters or greater on -site as shown on
the site and tree survey (Exhibit 10) and as identified in the Tree Retention Worksheet (Exhibit
5). The exisiting tree on site are located near the north and west property boundaries. No
critical areas are present on -site.
2. Environmental Review
Except when located
on lands covered by water or
sensitive areas,
short plats are exempt from
SEPA Environmental
Review pursuant to WAC 197-11-800(6)(a)I
As part of the geological assessment, the applicant describes the coal mine hazards mapped by
the City off -site (Exhibit 8, page 5). It should be noted
that these hazards
are
not located on -
site, but the site is within a distance to provide further
analysis. Based on
the
geotechnical
engineer's analysis, the mines appear to be located at
least two blocks to
the
north and
northwest of the subject
site and does not extend into
the boundaries of
the
subject property.
3. Staff Review Comments
Representatives from various city departments have reviewed the application materials to
identify and address issues raised by the proposed development. These comments are
Short Plat Report LUA74-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 5 of 19
contained in
the official file,
and the essence of the comments
have been incorporated into the
appropriate
sections of this
report and the "Advisory Notes to
the Applicant' (Exhibit 15),
4. Comment from the Public
One public comment was received and no comments were received from agencies. The public
comment (Exhibit 14) specifically states that larger yards and more green landscaping for the
new residential lots would fit better in the neighborhood and that the neighborhood is home
to mammals, birds, amphibians and beneficial insects. The commenter further states that any
pollution from the site eventually impacts the Duwamish watershed and Puget Sound and that
retaining and planting more trees and shrubs helps prevent runoff and reduces noise and air
pollution. Additionally, the commenter states a storm retention pond surrounded by fencing is
unsightly and rain gardens would be more aesthetically pleasing. For street improvements, the
commenter states that the construction of any sidewalk would hopefully not narrow the road
as parked cars impede traffic flow.
5. Consistency with Short Plat Criteria
Approval of a short plat is based upon several factors. The following short plat criteria have
been established to assist decision -makers in the review of the short plat:
1. FINDINGS:
Having reviewed the written record in the matter, the City now enters the following:
1. Request: The project proponent has requested approval of a short plat subdivision of a 29,912
sf corner (0.69-acre) property in the Cascade community into 5 lots suitable for development
with single-family residential structures, where the existing single-family dwelling would be
demolished. The project would have a density of 7.8 du/ac.
2. Application: The subject site is owned by Virtuoso Venture 6 LLC; 14508 NE 20th St, Suite 200,
Bellevue, WA 98007.
Comprehensive Plan: The property has a Comprehensive Plan land use designation of
Residential Single -Family (RSF). The proposed project furthers the objectives and policies of the
RSF section of the Land Use Element of the Comprehensive Plan. The objectives and policies of
the Community Design Element are also supported by the project as it has been proposed.
4. Zoning: Objectives and policies of the RSF designation are implemented by standards and
regulations of the Residential 8 zone. The project, as proposed, meets or exceeds the R-8 zone
standards and regulations, if conditions of approval are met.
5. Subdivision Regulations: The short plat, as proposed, would meet the requirements of RMC 4-
7 Subdivision Regulations, if conditions of approval are met.
6. Existing Land Uses: The site consists of one parcel with an existing family home and accessory
structure, which is proposed to be removed
7. Setbacks: Minimum setback requirements of the R-8 zone could be met.
Be Short Plat Review Criteria: Approval of a plat is based upon several factors. The following short
plat criteria, in the matrix below, have been established to assist decision -makers in the review
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 6 of 19
of the plat.
The criteria
are evaluated on
compliancy, and the
depth of compliance is
provided
through a
denotation
next to the criteria text as follows:
(✓ Compliant; Note 1:
Partially
compliant;
Note 2: Not
compliant; Note 3:
Compliance not yet
demonstrated).
1 ' CONFORMANCE WITH THE.CDMPREHENSIVE PLAN:'':ll The site has the Comprehensive Land'!
Use designs#ion of Resid%ential Single Fam%ily (RSF): %Land clesignated% RSF%. is intended to be used for
high' quality, detach%ed; single -fa mily,res%id%ental development organiwed into; neighborhoods at
urban %densities: Iteis'intended.tleehat larger subdiGisions„infill-development%, rehabi%ellitatel%ion-of'
%and
existing hou%sing,be carefully designed to enhance% and imprtive'the quality ofle family living
Aee%e;siiel%igle
environinents:`The proposal is,consistent with% the following Comprehensive.Plan"Land Use
%and'
Conniunity,Desfgn Element policies if.all conditions:of'approval are met; unless noted otherwise:.
Policy LU458. Net development densities should fall within a range of 4 to 8 dwelling
units per acre in Residential Single Family Neighborhoods.
Staff Comment: The proposed density would be 7.8 du/ac (Exhibit 16). The proposed
density is within the required range.
Objective CD-C. Promote reinvestment in and upgrade of existing residential
neighborhoods through redevelopment of small, underutilized parcels with infill
development, modification and alteration of older housing stock, and improvements to
✓
streets and sidewalks to increase property values.
Staff Comment: Five new residential parcels would be created for infill, where an existing
single-family dwelling constructed in the 1940s would be demolished.
Policy CD42. Sidewalks or walking paths should be provided along streets in established
neighborhoods, where sidewalks have not been previously constructed. Sidewalk width
should be ample to safely and comfortably accommodate pedestrian traffic and, where
practical, match existing sidewalks.
Staff Comment: The property is a corner lot, with street frontage along SE 162nd St of
approximately 200 feet in length, and approximately 150 feet in length along 114th Ave
✓
SE (Exhibit 10). There are no street improvements on either right-of-way (Exhibit 15 —
Engineering Review, Existing Conditions subsection). Proposed street improvements
would include curb, gutter, planter strip and sidewalk for both street frontage of
subdivision. The applicant proposes to install the improvements on both streets, and
additionally dedicate right-of-way area at the southeast corner of the intersection for the
required corner radius at the intersection. There are no street frontage improvements
along the frontage of any surrounding streets.
Policy CD44. Infill development, defined as new short plats of nine or fewer lots, should
be encouraged in order to add variety, updated housing stock, and new vitality to
✓
neighborhoods.
Staff Comment: The five proposed lots would allow for updated housing stock.
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 7 of 19
Policy CD-15. Infill development should be reflective of the existing character of
established neighborhoods even when designed using different architectural styles, and
/or responding to more urban setbacks, height or lot requirements. Infill development
should draw on elements of existing development such as placement of structures,
Note
vegetation, and location of entries and walkways, to reflect the site planning and scale of
3
existing areas.
Staff Comment: Detailed site and architectural designs, will be reviewed to determine
compatibility with the context of the site, at the time building permits are submitted.
P:'GOMP%OANCE WITHIIIE LIND11%,ERLY%INd ONING DESIGNATION: ,Objectives and polices'ofthe
Comprehensive,Land Use Plan,(t%esid14'ential`Single:Family-designation are implemented' by, „=,';-.;
Resjdentiiaj 8 zoning (R-8). RMC4-2-110A'provides development standards, for development; '-
within%11, the 8 zoning classification: The proposal is"consistent with t%he following :-
11%111R %d%evelopment
standards if aliconditions of ap%proval are O e61%1t unless noted otherwise:.'. ;
Density: The minimum density allowed in the R-8 zone is 4 dwelling units per net acre
(du/ac). The maximum density permitted in the R-8 zone is 8.0 du/as. Net density is
calculated after the deduction of critical areas, areas intended for public rights -of -way,
and private access easements. Calculations for minimum or maximum density that
result in a fraction that is 0.50 or greater shall be rounded up to the nearest whole
number. Those density calculations resulting in a fraction that is less than 0.50 shall be
rounded down to the nearest whole number.
Staff Comment: After deducting 48 sf for right-of-way dedications and 1,980 sf for access
easement across Lot 4 from the 29,912 gross sf of the site, the net square footage would
be 27,884 sf (0.64 net acres). The 5-lot proposal would arrive at a net residential density
of 7.8 dwelling units per acre (5 units/0.64 acres = 7.8 du/ac), which falls within the
permitted density range for the R-8 zoning classification.
Lot Dimensions: Staff Comment: R-8 Standards apply:
Proposed Lots Lot Size Width minimum Depth
(Exhibit 3) 5,000 SF 50 feet -interior, 60 65 feet minimum
minimum feet -corner
Lot 1- Interior 5,039 sf 50.6 ft 99.5 ft
Lot 2 - Interior 5,034 sf 50.65 ft 99.4 ft
Lot 3 - Corner 5,892 sf 60.0 ft 99.0 ft
Lot 4 - Interior 8,834 gross sf 89.32 ft 99.0 ft
6,854 net sf
Lot 5 - Interior 5,065 sf 50.0 ft 101.3 ft
Setbacks: The minimum front yard setback in the R-8 zone is 15 feet; minimum side yard
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 8 of 19
✓
is 5 feet and, minimum side yard along a street 15 feet for the primary structure;
minimum rear yard is 20 feet.
Staff Comment: For all lots, there is sufficient area for new residential structures that
would comply with setbacks. All proposed buildings would be reviewed for setbacks at
time of building permit.
The site currently contains one single family residence and a detached structure all of
which are proposed to be removed. Staff recommends, as a condition of approval that all
structures proposed for removal be demolished prior to Final Plat approval.
Building Standards: The R-8 zone permits one single family residential structure per lot.
Accessory structures are permitted at a maximum number of two per lot with a
maximum size of 720 square feet each, or a maximum of one per lot with a maximum of
1,000 square feet. Accessory structures are permitted only when associated with a
primary structure located on the same parcel of land.
The maximum building height in the R-8 zone is 30 feet. Building height is based on the
measurement of the vertical distance from the grade plane to the average height of the
roof surface. The grade plane is the average of existing ground level adjoining the
building at exterior walls. Where the finished ground level slopes away from the exterior
walls, the reference plane shall be established by the lowest points within the area
Note 3
between the building and the lot line, or where the lot line is more than 6 feet from the
building, between the building and a point 6 feet from the building.
The maximum building coverage in the R-8 zone, for lots larger than 5,000 sf, is 35
percent or 2,500 sf, whichever is greater.
The maximum impervious surface area is 75 percent.
Staff Comment: For all lots, building elevations, floor plans and a site plan, which would
be used to determine building height, building coverage and impervious surface
coverage, have not been submitted. They would be submitted for building permit review
(compliance not yet demonstrated).
Landscaping: Landscaping is required for all subdivisions including short plats. A detailed
landscape plan is usually required to be approved prior to issuance of street or utility
construction permits.
A ten foot -wide on -site landscaped area is required along all public street frontages, with
the exception of areas for required crosswalks and driveways. This landscaped area shall
be on -site and shall include a mixture of trees, shrubs and ground cover. Two trees are
required in the front yard of each lot.
For street improvements, and street trees and landscaping required within the right-of-
way, a minimum planting strip width between the curb and sidewalk are established
according to the street development standards of RMC 4-6-060. Street trees and, at a
minimum, groundcover per subsection 4-4-070 L2, are to be located in this area when
present. Spacing standards shall be as stipulated by the Department of Community and
Economic Development, provided there shall be a minimum of one street tree planted
per address. Any additional undeveloped right-of-way areas shall be landscape unless
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA24-001083; SHPL-A
Report of October 15, 2014 Page 9 of 19
otherwise determine by the Administrator. Refer to the City's Approved Tree list and
spacing standards available through the Department of Community and Economic
Development and on the City's website.
Staff Comment: The applicant submitted a conceptual landscape plan (Exhibit 111for on -
site landscape improvements and trees to be removed and retained. The applicant
submitted off -site improvements for the two abutting streets with planting strip widths
identified, but no landscaping and street trees identified. For the on -site improvements,
no landscaping is required for Lot 5 as it is not along a street frontage but is allowed.
Additionally, curb cuts are not shown on the provided landscape plan, therefore the plan
does not around for necessary driveways and access points. Existing vegetation along SE
162"d St for Lots 2 and 3 would be used to meet the required on -site landscaping (see
additional dissection below under tree retention). Therefore, as there are no street trees
shown in the off -site planter strips, it is unclear if all proposed trees for retention will be
able to be retained, and driveways for each lot should be identified where landscaping
cannot be planted, staff recommends, as a condition of approval, that on -site and off -site
landscape plans that are consistent with code be provided to, and approved by, the
Current Planning Project Manager prior to construction permit approval. The applicant
shall be required to submit a revised landscape plan, depicting a 10 foot wide on -site
landscape strip for all lots with the identified driveway cuts. The applicant shall be
required to submit a landscape plan for the off -site landscaping planter strips in the
roadway with proper spacing and species identified according to the spacing standards
and approved tree list available on the Citv's website.
Tree Retention: Existing trees shall be retained where feasible. RMC 4-4-130 requires 30
percent of trees to be retained. If the required number of trees cannot be retained, they
must be replaced according to RMC 4-4-130H,
Staff Comment: According to the site and tree survey there are 12 significant trees 6-inch
in diameter or greater on the site (Exhibit 10). The Tree Retention Worksheet (Exhibit 5)
shows that 3.6 trees would need to be retained to meet the 30 percent requirement for
the zone. The applicant's proposal is to retain 9 trees which is greater than the retention
requirement of 3.6 trees resulting in 75 percent of the tree to be retained. The trees to be
retained are shown on the Tree Retention Plan (Exhibit 11), with three (numbers 1-3)
located along the 114`h right-of-way and 9 (numbers 4-12) located along the SE 162nd St.
Staff recognizes that the proposed trees to be retained are within close proximity to
proposed street improvements and the future footprint of the home to be constructed on
Lot 3. Mature trees such as the ones on -site and identified to be retained may not be able
to be protected through the installation of utilities, street improvements, and earthwork
that may be required as part of site development. Based on the identified drip lines the
street improvements would impact all the drip lines of the trees proposed to be retained.
As such staff recommends, as a condition of approval, that an arborist report be
prepared by the developer, reviewed and approved by the Current Planning Project
Manager. The arborist report shall identify if the trees can be retained throughout
construction and not impact the health of the tree. If it is identified that the trees
retention cannot be retained through construction, an update tree retention
Short Plat Report CUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 10 of 19
plan and if necessary tree replacement plan shall be provided for approval prior to
construction permit issuance.
Additionally, as part of site improvements and to assist in the healthy retention of trees
to be kept as part of the short plat process and construction of new homes, there are
requirements to buffer retained trees from construction equipment and as part of the site
development process (Exhibit 15 —Advisory notes).
Parking: Off-street parking for 2 vehicles per residential unit is required.
✓
Staff Comment: There is sufficient space to provide on -site parking on the proposed lots.
All proposed buildings would be reviewed for parking requirements at time of building
permit.
3. DESI,GNSTANDARD%S Residential"Design and Open Space,Standards (RMC14-2-115);are
applicabl0h the R zone. The Standards implement;o%dlicieslesiablished-in the Land Use'and"..
111%8
Community Design,Elementsofthe Comprehensive -Plan. Compliance withSite Desigri Standards
must beid%emonstrat111%ed priorto approval of the subdivision. Compliance with Residential Design'"`;.
Standards would be%verified prior to issuance of building permits. The proposal is consistentwith,":
Ie
the: following design standards, 6nless,noted'otlierwiI,vse:%% "
Lot Configuration: Standards apply to subdivisions of 4 or more street -fronting lots.
Variety in the configuration of lots enhances the image of variety of housing stock and
helps minimize perceptions of monotony. One of the following is required:
1. Lot width variation of 10 feet minimum of one per four abutting street -fronting
lots, or
2. Minimum of four lot sizes (minimum of 400 gross square feet size difference), or
3. A front yard setback variation of at least 5 feet minimum for at least every four
abutting street fronting lots.
Staff Comment: The 5-lot subdivision has four street fronting lots in sequence, or
abutting, around the corner at SE 162°d St and SE 114`h Ave SE so the Lot Configuration
requirement applies to the proposal (Exhibit 3). Lots 1 and 2 have lot widths of
approximately 50 ft and Lot 3 has a width of approximately 60 ft and Lot 4 has a width
of approximately 89 ft. Therefore, of the four abutting street fronting lots, there is a
minimum lot width variation of at least 10 feet between Lots 1 and 2, and Lots 3 and 4,
which complies with the first requirement of the Lot Configuration standard.
Garages: The minimization of the visual impact of garages contributes to creating
communities that are oriented to people and pedestrians, as opposed to automobiles.
One of the following is required (some options are not listed here due to lack of site
feasibility, i.e. garages accessed from alley):
Note
1. Recessed from the front of the house and/or front porch at least 8 feet, or
3
2. Located so the roof extends at least 5 feet (excluding eaves) beyond the front of
the garage for at least the width of the garage, plus the porch/stoop area, or
3. Sized so that it represents no greater than 50 percent of the width of the front
fagade at ground level, or
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 11 of 19
4. Detached.
The portion of the garage wider than 26 feet across the front shall be set back at least 2
feet.
Staff Comment: For the lots, building plans, which would be used to determine visual
impact of garages, have not been submitted yet. They would be submitted for building
permit review (compliance not demonstrated).
Primary Entry: Entrances to houses shall be a focal point and allow space for social
interaction. One of the following is required:
1. Stoop: minimum 4 feet by 6 feet and 12 inches above grade, or
Note
2. Porch: minimum 5 feet deep and 12 inches above grade.
3
Exception: An ADA accessible route may be taken from a front driveway.
Staff Comment: For the lots, building designs, which would be used to evaluate design of
entrances, have not been submitted yet. They would be submitted for building permit
review (compliance not demonstrated).
Fayade Modulation: Buildings shall not have monotonous facades along public areas.
One of the following is required:
1. An offset of at least one story that is at least 10 feet wide and 2 feet in depth on
Note
facades visible from the street, or
3
2. At least a 2-foot offset of second story from first story on one street -facing fagade.
Staff Comment: For the lots, building designs, which would be used to evaluate design of
facades, have not been submitted yet. They would be submitted for building permit
review (compliance not demonstrated).
Windows and Doors: Windows and front doors are an integral part of the architectural
character of a house. Windows and doors shall constitute 25 percent of all facades
facing street frontage or the front yard for homes not facing a public street.
Staff Comment: Building designs which would be used to evaluate design of windows and
Note
doors, have not been submitted yet. They would be submitted for building permit review
3
(compliance not demonstrated). One corner lot is being created through the subdivision,
therefore, as a condition of approval, staff recommends that the Lot 3 corner lot be
required to have 25 percent openings of windows and/or doors on the two facades facing
public streets.
Scale, Bulk, and Character: Neighborhoods shall have a variety of home sizes and
character. Abutting houses shall have differing architectural elevations.
Note
3
Staff Comment: For the lots, building designs, which would be used to evaluate scale,
bulk, and character of structures, have not been submitted yet. They would be submitted
for building permit review (compliance not demonstrated).
Note
Roofs: Roof forms and profiles are an important architectural component. One of the
3
following is required:
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 12 of 19
1. Hip or gabled roof with at least a 6:12 pitch for the prominent form of the roof
(dormers, etc.), may have lesser pitch, or
2. Shed roof.
Staff Comment: For the lots, building designs, which would be used to evaluate roof
forms, have not been submitted yet. They would be submitted for building permit review
(compliance not demonstrated).
Eaves: Eaves and overhangs act as unifying elements in the architectural character of a
house. Both of the following are required:
1. Eaves projecting from the roof of the entire building at least 12 inches with
horizontal fascia or fascia gutter at least 5 inches deep on the face of all eaves, and
Note
2• Rakes on gable ends must extend a minimum of 2 inches from the surface of
3
exterior siding materials.
Staff Comment: For the lots, building designs, which would be used to evaluate design of
eaves and overhangs, have not been submitted yet. They would be submitted for building
permit review (compliance not demonstrated).
Architectural Detailing: Architectural detailing contributes to the visual appeal of a
house and the community. If one siding material is used on any side of the dwelling that
is two stories or greater in height, a horizontal band that measures at least 8 inches is
required between the first and second story. Also, one of the following is required:
1. Minimum 3-1/2 inch trim surrounds all windows and details all doors, or
Note
3
2. A combination of shutters and minimum 3-1/2 inch trim details all windows and
minimum 3-1/2 inch details all doors.
Staff Comment: For the lots, building designs, which would be used to evaluate
architectural detailing, have not been submitted yet. They would be submitted for
building permit review (compliance not demonstrated).
Materials and Color: A variety of materials and color contributes to the diversity of
housing in the community. Abutting houses shall be different colors. Color palettes for all
new dwellings, coded to the building elevations, shall be submitted for approval.
Additionally, one of the following is required:
1. A minimum of 2 colors shall be used on the building (a main color with different
Note
trim color is acceptable), or
3
2. A minimum of 2 different siding materials shall be used on the building. One siding
material shall comprise a minimum 30 percent of the street -facing fagade. If
masonry siding is used, it shall wrap the corners no less than 24 inches.
Staff Comment: For the lots, building designs, which would be used to evaluate material
and color choices, have not been submitted yet. They would be submitted for building
permit review (compliance not demonstrated).
4: `COMPLIANCE:WITHSUBDIVISION%11
R11 EGULATIONS: R11 MC 4-7 Provides review criteria for:'"
proposed
subdivisions. The proposed project js consistent with the following subdivision:
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 13 of 19
regula%ti%ons
if all condiiioris of approv%al arz complied with:'%'`
.% %, .--';'
Access: Each lot must have access to a public street, private road, or by a private access
easement per the requirements of the street standards.
Staff Comment: Access to the lots vary as there are two streets abutting the site (Exhibit
3). Based on the application materials, it is unclear where the access points to the
proposed lots would be located. The discrepancies is between the Preliminary Short Plat
Plan (Exhibit 3) created by GeoDimensions and the Paving and Grading Plan created by
Springline Design (Exhibit 7), GeoDimensions' plan states there are shared access
easements between Lot 1 and Lot 2 and between Lot 3 and Lot 4 as written on the plan,
where the Springline Design created plan shows individual driveways for all of the 5 lot.
Therefore, staff recommends, as a condition of approval, that the submitted Preliminary
Short Plat by GeoDimensions that identifies shared access easements for Lots 1 and 2,
and Lots 3 and 4, with a accessess easement for Lot 5 along the southern boundary of the
site be the approved access points for the residential lots. The shared driveway access
easements shall be recorded on the face of the Short Plat.
A curb cut more than 50 feet in distance to an intersection (as shown on Lot 3, Exhibit 7)
is not permited due to safety concerns of vehicles traveling in the roadway and the
ingress and egress of vehicles from the lot. Therefore, staff recommends, as a condition
of approval, that a curb cut to Lot 3 would not be allowed closer than 50 feet in proximity
to the intersection.
Given stop's recommended conditions of approval in this section, all relative plans are
required to be updated showing the approved curb cut and shared access locations, and
provided to and approved by the Current Planning Project Manager as part of the
construction permit review process.
Alleys: Alley access is the preferred street pattern for all new residential development in
the R-8 zone. New residential development in areas without existing alleys shall utilize
alley access for interior lots. The City will consider the following factors in determining
whether the use of alleys is not practical: A) Size: The new development is a short plat; B)
Topography: The topography of the site proposed for development is not conducive for
an alley configuration; C) Environmental Impacts: The use of alleys would have more of a
negative impact on the environment than a street pattern without alleys.
Staff Comment: The proposal is required to consider alleys as part of the layout because
the project is 6 du/ac or greater. Pursuant to criterion A, the subject project is a short
plat therefore an alley is not required.
Streets: The short plat is the subdivision of a corner lot into five lots, with street
frontages along both SE 162nd St and 114`h Ave SE. Street improvements are required
along both streets. Street lighting is required for a five lot short plat.
Staff Comment: Both SE 162"d St and 114th Ave SE are classified as Residential Access
streets and require 53 feet of width. For both streets there are existing widths of 60 feet.
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 14 of 19
Therefore, the applicant is not required to dedicate right-of-way except for a triangular
shaped area at the intersection of the streets to provide for minimum radius where the
streets connect. Currently, there are no street improvements along either right-of-way.
The proposal is to provide required paving, curb, gutter, planter strip, and sidewalk along
both street frontages: The planter strip would be 8 ft in width where street trees would
be located, and the sidewalk would be 5 ft in width.
Blocks: Blocks shall be deep enough to allow two tiers of lots.
N/A
Staff Comment: No new blocks or streets are proposed, therefore the criteria does not
apply.
5:',:AVAILABI%LI%TY:AND%IMPACT
O%N PUBLIC SERVICES:: -- . ; -, - I
,- %,.'
Police: The Renton Police Department has commented that the proposed project would
have probable minor impacts.
Fire: Sufficient resources exist to furnish services to the proposed development, subject
to the condition that the applicant provides Code required improvements and fees
(Exhibit 15, Fire Review subsection).
The fire flow requirement for a single-family residence is minimum 1,000 gpm for
structures up to 3,600 sf, including attached garage and basement. If dwellings exceed
3,600 sf, a minimum of 1,500 gpm would be required. A minimum of one fire hydrant is
required within 300 feet of the proposed buildings and two hydrants if the fire flow
requirement increases to 1,500 gpm:
A water availability certificate is required from Soos Creek Water and Sewer District.
Therefore, staff recommends the certificate be required as part of the construction
permit application.
Fire Impact Fees shall be paid prior to issuance of building permits. This fee is assessed
per new single family lot at the rate in place at the time the building permit is issued.
For 2014 and 2015 the fee is $479.28 per new single family lot and fees may increase
year to year. The fee shall be payable to the City as specified by the Renton Municipal
Code prior to building permit issuance.
Schools: It is anticipated that the Renton School District can accommodate any
additional students generated by this proposal at the following schools (Exhibit 12):
Cascade Elementary (0.14 miles from the subject site), Nelsen Middle School (0.49 miles
from the subject site) and Lindbergh High School (1.0 miles from the subject site). RCW
58.17.110(2) provides that no subdivision be approved without making a written finding
of adequate provisions for safe walking conditions for students who walk to and from
school and/or bus stops. Maplewood Elementary and Nelsen Middle Schools are within
walking distance of the subject site and Lindbergh High School would require future
students to be transported to school via bus (Exhibit 13, bus stop locator). When a
school is within walking distance, the school district document text reads "within walking
distance' instead of "Eligible'. For students that are bused to the High School, there
would be a safe route to school.
The applicant is proposing street frontage improvements, including sidewalks, along the
south side of the street frontage of the property along SE 162"d St and along the east
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plot Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 15 of 19
side of the street frontage of the property along 114th Ave SE. To the east of the subject
site on SE 162"d St, there are no existing sidewalks on the south side of the street. To the
south of the subject site, on 114th Ave SE, there are no existing sidewalks on the east side
of the street. A safe walking route to Cascade Elementary and Nelsen Middle Schools
would necessitate potential improvements to establish a safe route to each of the
schools to be walked to. Therefore, staff recommends as a condition of approval that the
applicant provide a safe route to school plan to, and approved by, the Current Planning
Project Manager, prior to construction permit application.
School impact fees shall be paid prior to issuance of building permits. This fee is assessed
per new single family lot at the rate in place at the time the building permit is issued.
For 2014 the fee is $5,455 per dwelling, and for 2015 the fee is $5,541 per dwelling and
shall be paid prior to building permit issuance.
Parks: Although there would be no significant impacts to the City of Renton Park System
anticipated from the proposed project, an impact fee is required of all new residential
development.
Park impact fees shall be paid prior to issuance of building permits. This fee is assessed
per new single family lot at the rate in place at the time the building permit is issued. For
2014 the fee is $963.01 per dwelling and for 2015, the fee is $1,395,25.
Stormwater: A drainage report was submitted by Springline Design LLC (Exhibit 9) with
the land use application, dated July 7, 2014. The drainage report complies with the 2009
King County Surface Water Manual and City Amendments. Based on the City's flow
control map, the 5-lot short plat, zoned R-8 falls within the Flow Control Standard,
Forested Condition, The 0.69-acre site has one existing home to be demolished. The site
is subject to Full Drainage. Additionally, the proposal would create a stormwater facility
extension south of the site within 114th Ave SE (Exhibit 6).
The engineer is proposing to mitigate a portion of the new runoff created by the project
by installing permeable pavement in lieu of the city's standard 5-foot wide concrete
sidewalk in the right-of-way. The City would not support the permeable pavement in the
right-of-way. Therefore, as a condition of approval, staff recommends that any
permeable pavement proposed be updated to reflect an accepted pavement material by
the City.
Stormwater on the developed site would discharge to the same threshold discharge area
as with pre -developed conditions with the existing on -site home. The discharge area
would include the on -site and off -site street frontage improvements under developed
Note 1 conditions. The project would provide flow control for impervious surfaces using a
detention pipe in addition to other flow control best management practices. The
detention pipe would be remodeled and updated during the construction permit
submittal to reflect the latest building footprint revisions. The project would not be
required to implement water quality treatment facilities as there is not more than 5,000
sf of pollution generating surface added for right-of-way or private improvements.
Erosion and sediment control recommendations are also provided.
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 16 of 19
Geotechnical recommendations report prepared by PanGEO Inc (Exhibit 8), dated June
24, 2014, describes existing site and subsoil conditions and recommendations for site
development following review of readily available geologic data, site reconnaissance,
and text pit excavations. It is anticipated that site grading for home foundations would
include cuts and fill on the order of 4 ft. For utility construction, it is anticipated that cuts
and fill may be as deep as 7 to 8 ft.
Five test pit excavations were dug in the area to explore the general subsurface
conditions of the site. Excavations were performed to a depth of about 7 to 8 ft. In
summary, the test pits generally encountered three distinctive soil units: 1) topsoil/fill, 2)
till -like deposits, and 3) sandstone. Moderate to heavy groundwater seepage was
encountered in all test pits at depths of about 1 to 5 feet below the surface. The
groundwater seepage is perched above the dense till and are likely to vary depending on
the season, local subsurface conditions, and other factors. It is recognized that
groundwater levels are normally highest during the winter and early spring.
Recommendations for site preparation, foundation design, and excavations and
dewatering for building and utility construction are provided.
The geotechnical report provides a recommendation that a qualified geotechnical
engineering service be retained to conduct a review of the final project plans and
specifications, and to monitor the construction of geotechnical elements. Therefore,
staff recommends, as a condition of approval, that a qualified geotechnical engineering
service provide services for review of final project plans and monitoring of geotechnical
construction elements.
Stormwater drainage plans for individual lots will be required prior to issuance of
construction permits. The Surface Water System Development fee for 2014 is $1,228,00
per new lot. Fees may increase year to year. Fees are payable prior to issuance of the
construction permit.
Water Service: The project is located in the Soos Creek Water and Sewer district. A
water availability certificate will be required to be submitted to the City as part of
construction permit application.
Additionally, all new construction must have a fire hydrant capable of delivering a
minimum of 1,000 gpm and must be located within 300 feet of the structures. A
minimum of one new hydrant will be required to be installed.
Sanitary Sewer Service: The project is located in the Soos Creek Water and Sewer
district. A sewer availability certificate will be required to be submitted to the City as
✓
part of construction permit application.Therefore, staff recommends the certificate be
required as part of the construction permit application.
Transportation: Impacts to the city transportation system are expected, due to
✓
increased vehicle trips to and from the proposed project. The 2014 Traffic Impact fee is
$1,430.72 per single family home and the 2015 fee is $2,143.70. Credit would be
provided for existing homes. Right-of-way dedication is required at the southeast corner
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A '...
Report of October 15, 2014 Page 17 of 19
of the intersection of 114`" Ave SE or SE 162ntl St, of an approximate 48 sf area. Street
frontage improvements are required along both streets that include curb, gutter, 8-foot
planter strip, and 5-foot sidewalks. The Transportation Impact fee would be calculated
and assessed at the rate in effect when building permits are issued.
9. System Development Charges: As of the date of this report the Surface Water System
Development Fee is $1,228.00 per new lot; Water Service Fee is $2,809.00 per new lot; and
Sanitary Sewer Service is $2,033.00 per new lot. Fees change year to year.
10. Public Utilities: Sufficient public utilities would be available for the development of homes on
the proposed lots if all conditions of approval are met, where the applicant is required to
provide water and sewer availability certificates from Soos Creek Water and Sewer District.
11, Street Frontage Improvements: Right-of-way dedication of approximately 48 sf is required at
the streets intersection for radius and improvements. Improvements for both streets, SE 162"d
St and 114th Ave SE, are required to include 13 feet of paving from centerline, curb and gutter,
and 8-foot planter strip with trees, a 5-foot sidewalk, and storm drainage improvements
according to City code.
12. Safe Routes to School: Students would attend Renton School District. As referenced above, in
subsection Findings #8 "Short Plat Review Criteria"; subsection #5 "Availability and Impact on
Public Services -Schools", bussing would be provided to potential students for the Lindbergh
High School (Exhibit 13).
J. CONCLUSIONS:
1. The subject site is designated Residential Single Family (RSF) in the Comprehensive Land Use
Plan and complies with the goals, objectives, and policies established with this designation.
2. The subject site is zoned Residential 8 (R-8) and complies with the zoning and development
standards established with this designation, provided the applicant complies with the Renton
Municipal Code and conditions of approval.
The proposed 5-lot
short plat
complies with the subdivision regulations as established by City
Code and state
law
provided
all advisory notes and conditions are complied with.
K. DECISION:
The Limelite Short Plat, File No. LUA14-001083; SHPL-A; is APPROVED and subject to the
following conditions:
1. The applicant shall demolish and/or remove all existing structures proposed for removal prior
to Final Short Plat recording. A demolition permit shall be obtained and final inspection
performed for those structures demolished.
2. The applicant shall provide detailed landscape plans for both on -site and off -site landscaping
to the Current Planning Project Manager at the time of construction permit review. The
detailed landscape plans shall be reviewed and approved prior to construction permit
issuance.
3. The applicant shall provide a report prepared by a qualified arborist that evaluates and
determines whether or not trees identified to be retained can be retained throughout
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 18 of 19
construction and not impact the health of the tree. If it is identified that the trees for retention
cannot be retained through construction, an updated tree retention plan and if necessary, tree
replacement plan, shall be provided for review and approval by the Current Planning Project
Manager prior to construction permit issuance.
4. The corner lot, Lot 3, be required to have 25 percent openings of windows and/or doors on the
facades facing public streets. .
5. The approved access points for the residential lots shall be as shown on the preliminary short
plat layout submitted by GeoDimensions (Exhibit 3, titled "Proposed Lot Layout, Sheet 3 of 4,
dated 7/30/14). In addition, the shared driveway access easements as shown on the
GeoDimensions layout (Exhibit 3, titled "Proposed Lot Layout, Sheet 3 of 4, dated 7/30/14)
shall be recorded on the face of the short plat.
6. All curb cuts shall be no closer than 50 feet from the northwest corner of the property where
the SE 162nd St and 1141h Ave SE streets intersect. A note to this effect shall be placed on the
face of the short plat and shown on the construction engineering plans.
7. If plans change as a result of revisions needed to meet condition of approval number 5 above,
such changes shall be provided to the Current Planning Project Manager for review and
approval prior to the issuance of the construction permit.
8. The applicant must provide sufficient information to show how the students that walk to
school would have a safe walking route if bussing is not provided. If a safe route to school is
not identified, then the applicant will be required to provide a safe walking path, which may
entail some off -site improvements.
9. A qualified geotechnical engineering service shall be retained by the applicant to conduct a
review of final project plans and specifications, and to monitor the construction of
geotechnical elements.
10. Water and Sewer availability certificates from Soos Creek Water and Sewer District shall be
provided as part of construction permit application.
DECISION ON LAND USE ACTION:
SIGNATURE:
Jennifer T. Henning, Planning Director
Department of Community &Economic Development
TRANSMITTED this 15tb day of October, 2014 to the Contact/Applicant/Owner(s):
Contact:
Andy McAndrews; GeoDimensions
10801 Main St Suite 200
Belleveue WA 98004
Applicant:
Todd Karam; Limelite Development
14508 NE 20`h St, #200
Bellevue WA 98007
TRANSMITTED this 15`n day of October, 2014 to the Party(ies) of Record:
Melissa Richards
1401 N 40`h St
Renton, WA 98056
f
Date
Owner:
Virtuoso Ventura 6 LLC
14508 NE 20`h St, #200
Bellevue WA 98007
Dana Cook
Short Plat Report LUA14-001083
City of Renton Department of Community & Economic Development Administrative Short Plat Report & Decision
LIMELITE SHORT PLAT LUA14-001083; SHPL-A
Report of October 15, 2014 Page 19 of 19
11304 SE 1620d St
Renton, WA 98055
TRANSMITTED this 15`h day of October, 2014 to the following:
Chip Vincent, CED Administrator
Steve Lee, Development Engineering Manager
Craig Burnell, Building Official
Vanessa Dolbee, Current Planning Manager
Fire Marshal
L. LAND USE ACTION APPEALS, REQUEST FOR RECONSIDERATION, &EXPIRATION:
The administrative land use decision will become final if the decision is not appealed within 14 days of
the decision date.
APPEAL: This administrative land use decision will become final if not appealed in writing to the
Hearing Examiner on or before 5:00 PM on October 29, 2014. An appeal of the decision(s) must be
filed within the 14-day appeal period (RCW 43.21.C.075(3); WAC 19741-(580). Renton Municipal
Code Section 4-8-110.13 governs appeals to the Hearing Examiner. Appeals must be filed in writing
together with the required fee to the Hearing Examiner, City of Renton, 1055 South Grady Way,
Renton, WA 98057. Additional information regarding the appeal process may be obtained from the
City Clerk's Office, Renton City Hall - 7th Floor, (425) 430-6510.
EXPIRATION: The administrative short plat decision will expire two (2) years from the date of decision.
A single one (1) year extension may be requested pursuant to RMC 4-7-070.M,
RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be
reopened by the approval body. The approval body may modify his decision if material evidence not
readily discoverable prior to the original decision is found or if he finds there was misrepresentation of
fact. After review of the reconsideration request, if the approval body finds sufficient evidence to
amend the original decision, there will be no further extension of the appeal period. Any person
wishing to take further action must file a formal appeal within the 14-day appeal time frame.
THE APPEARANCE OF FAIRNESS DOCTRINE: provides that no ex parte (private one-on-one)
communications may occur concerning the land use decision. The Doctrine applies not only to the
initial decision, but to Appeals to the Hearing Examiner as well. All communications after the
decision/approval date must be made in writing through the Hearing Examiner. All communications
are public record and this permits all interested parties to know the contents of the communication
and would allow them to openly rebut the evidence in writing. Any violation of this doctrine could
result in the invalidation of the appeal by the Court.
Short Plat Report LUA14-001083
G4E 20 T23N R5E E 1/2
ZONING MAP BOOK
PLAN NING - TECHN ICAL SERVICES
PRINTED DATE: 1010312013
This dacumerd is graphic representation, not
gu ara teed to survey accuracy, and is based
on the best Information available as of the date
shown. This map is Intended for City display
sciences only.
Community & Economic Developmal
t-.rc+op-vh .w .ardrwWrA
nwmmxm
Im
14E 32 T23N R5E E 1/2 0 4zo 810 H4E
Feet
1:g,4gU 29 T23N R5E E 112
Page 61an80
City Limits (CV) Center Village Q(R-B) Residential earls;
ivy (RC) Resource Conservation
it 0(RM-F) Residential Mull -Family
dium ) Rest Will ) nal
EXHIBIT 2 ldulac QIRM-Uti=Family Rem. MulUrban oCenter
10dulac Q (RMH) Residential Manufactured] Homes
14dulac Q (UC N1) Urbn Center North 1
1dul (110112) Urbn Center North
s�
tlM a8Z000SSO0# XVl
SUOISUawiNO1N3H o
pOauj �= 1N3WdOl3A3431ll3W11
a`>s„ o' 'W4M13S2l'NEZI%Z33S17/13N'b/T3N
3x�M c
ltlld lUGHS ,12it/N I W I1321 -
d
— —
GS n
0970002900# lAoLjvd
m c o os _____________
NWA
�I 00�wu OJ ,x
I ✓ o
N
F H N z
N ps
an
H 0
g o0 o
0 0
oo s 3.a,ic.w w.ao ._
w 0 es .zr'sa Lq4 ie.La
am w "i"riia
�I ag �J '" �a3so
aqa
� � Iww
o
o „moo
s m.;p os
a"
p
3S 3Atl H16TT
.ice m ,1
City of Renton Development Services Division
1055 South Grady Way -Renton, WA 98055
Phone:425-430-7200 Fax:425-430-7231
1. Gross area of property:
1 • 29,912 square feet
2. Deductions: Certain areas are excluded from density calculations.
These include:
Public streets**
Private access easements**
Critical Areas*
Total excluded area:
3. Subtract line 2 from line 1 for net area:
4. Divide line 3 by 43,560 for net acreage:
5. Number of dwelling units or lots planned:
square feet
11980 square feet
0 square feet
2. 11980 square feet
3. 27,932 square feet
4. 0,64 acres
5.
units/lots
6. Divide line 5 by line 4 for net density: 6. 7.80 =dwelling units/acre
*Critical Areas are defined as "Areas determined by the City to be not suitable for
development and which are subject to the City's Critical Areas Regulations
including very high landslide areas, protected slopes, wetlands or floodways."
Critical areas buffers are not deducted/excluded.
** Alleys (public or private) do not have to be excluded.
AUG 1
RAPMDEVSERV\Focros\PlanningW Last update&IIYD9/20041' ` t
EXHIBIT 4
City
1. Total number of trees over 6" in diameteron project site:1, 12 trees
2. Deductions: Certain trees are excluded from the retention calculation:
Trees that are dead, diseased or dangerous2 0 trees
Trees in proposed public streets 0 trees
Trees in proposed private access easements/tracts p trees
Trees in critical areas3 and buffers trees
Total number of excluded trees: 2. 0 trees
3. Subtract line 2 from line 1: 3, 12 trees
4. Next, to determine the number of trees that must be retained 4, multiply line 3 by:
0.3 in zones RC, R-1, R-4, or R-8
0A in all other residential zones
0,05 in all commercial and industrial zones 4. 16 trees
5. List the number of 6" or larger trees that you are proposing5 to retain':
5. 9 trees
6. Subtract line 5 from line 4 for trees to be replaced: 6. 0 trees
(If line 6 is less than zero, stop here. No replacement trees are required).
7. Multiply line 6 by 12" for number of required replacement inches:
7• inches
8. Proposed size of trees to meet additional planting requirement:
(Minimum 2" caliper trees required) 8, inches
9. Divide .line 7 by line 8 for number of replacement trees6: per tree
(if remainder is .5 or greater, round up to the neat whole number)
'' Measured at chest height. 9• trees
' Dead, diseased or dangerous trees must be certified as such by a forester, registered landscape architect, or
certified arborist, and approved by the City.
' Critical Areas, such as wetlands, streams, floodplains and protected slopes, are defined in Section 4-3-050 of
the Renton Municipal Code (RMC).
Count only those trees to be retained outside of critical areas and buffers.
The City may require modification of the tree retention plan to ensure retention of the max"I nyr je�Qf.,i ,,
trees per RMC 4-4-130H7a
s' Inches of street trees, inches of trees added to critical areas/buffers, and inches of trde'ssetdined-on site than ..
are less than 6" but are greater than 2" can be used to meet the tree. replacement requirement:
H:\CED\Data\Forms-Templates\' EXHIBIT 5 L2/OS
C9
N
T
,s
+ pro
��
�30
a gg`aY
N 9 `�K fee k
III
_
ap
a��
v
^ 5 x 5 x Z ee a ouwi
ILL
IN
aNil
IN
oIN IN
INN
I II I j Haan}_ >
.oeos woo
w'
IINI ova
IN
IN
ti
-- _
- - r
I �I --©.IN, NI,t IN
IN I
Z
IN 0 U1
I -- -- I F
IN
I I F i i
I i 'l .. ',f 0 . I II' U 4
I.., /I 1 �I U
! ¢¢
NJ
K
L IN
INN IN i INN
INN
i Z
INN
on ,G s,1s..N a
II� if,�. �.. ! r46 11 �Il // I� Z
r "�-. , t _ O J
c% 7`11 i 3 IN,e� / N w
IN
Iji r' ?�
IINN' IN IN INN IN-
Nri
If
IN N�II� I1� ���f IN
`r t -" ' t
ar
r INN
JIN
I I / e 65
m,i
ql - fL iIN
i ® �$
- c9a
ik , m�E
IN N)�I t a =a
mB .
INN-
k
'
Y
gY- . .i 4 I
1 INN�
lllf .. �
eg .y I�
a as and tuj = -
it
EXHIBIT 7
Entire Document
Available Upon Request
June 24, 2014
Project No. 14-052
Mr. Todd Karam
Limelite Development
14508 NE 20`t' Street, Suite 200
Bellevue, WA 98007
Subject: Geotechnical Engineering Report
Proposed Short Plat and Development
16204 —114th Avenue SE, Renton, Washington
Dear Mr. Karam,
1 I.LL AGE@
' Geotechnical & Earthquake
Engineenng Consultants
As requested, PanGEO, Inc. completed a geotechnical engineering study to assist you and
your project team with the proposed short plat and development at the above -referenced
property. This study was performed in accordance with our mutually agreed scope of work
as outlined in our proposal dated March 4, 2014, and was subsequently approved by you on
the same day. Our service scope included reviewing readily available geologic data,
conducting a site reconnaissance, excavating five test pits, and developing the conclusions
and recommendations presented in this report.
SITE AND PROJECT DESCRIPTION
The subject property is an approximately 29,900 square foot lot located at 16204 — 114th
Avenue SE in the City of Renton, Washington (see Figure 1, Vicinity Map). The subject lot
is roughly rectangular in shape, and is bordered to the north by SE 162nd Street, to the west
by 114`h Avenue SE, and to the east and south by existing single-family residences (see
Figure 2, Site and Exploration Plan). An existing single-family residence occupies the
central portion of the site (see Plates 1 and 2 on Page 2 and Figure 2). A detached garage is
located in the southeastern corner of the lot. The site is covered with short grass with
several mature trees at the time of our field exploration. The existing site grade is generally
level.
3213 Eavdake Avenue East, Suite B
Seatfle, WA 98(02
(206)262-0370
springline design LLC
Civil Engineering I Site Development I Transportation
Project
Prepared For:
Prepared By:
Reviewed By:
Date:
Entire Document
Available Upon Request
Limelite Short Plat
11419 SE 162nd Street
Renton, WA 98055
Limelite Development
14508 NE 20M St. #200
Seattle, WA 98007
Chris Puma
Peter Apostol, PE
July 7, 2014
EXHIBIT 9
3131 Western Avenue, Suite 501
Seattle, Washington 98121
ph 206.957.8311 fax 206,957.8313
1°a fla
s`3
?'LgI9I^ .NG DIVI'a N
s u 01
s u a w l Q
0aO
N
CIs
�w
QD
0
el
I
tlM NOA31
N su
68Z0008806# XVl o o a
`m 60�L 4 OdQL
� m
..'e, 1N3WdOl3A34 31113WI1
'W'M'3S2l N£Zl'6ZJ3S'b/T3N'b/T3N
iVIdiaOHSAHVNIWIRld J N
e
a o 3
8 e❑ A a (aI❑ • I
09Z0008800# 13J21Vd
��/R 3S 3Atl H1yTT '"` y-
rono I_ -m.
d _
0
0
0
EXHIBIT 10
VM
e 08Z0008800# XVl NO1N3N
SuoISuawI(]oaO FM "= A3MO13A3o31113A11
al
mm,*' 'W'M'3Sa'N£Z1'6ZMIS 'IIN'b/TIN o
__. �"D c2 1VldildOHSAaVNIWil3U _< ww
09Z0009900# 130?]Vd
�
o`
o
a
o
s
ILI
�
In
o
EL
IN
If
m�
29
'o�
w
�'
z���555533
a�so.�aaaRxRR
a
NI
osT.'s°s
05
~ aamoe
I
S
L
Ic
aM
111�\�
IIn
ILI
EXHIBIT 11
Kris Sorensen
From: Randy Matheson <randy.matheson@rentonschools.us>
Sent: Thursday, October 09, 2014 9:43 AM
To: Kris Sorensen
Cc: Kayla Steckler; Sabrina Mirante
Subject: RE: City of Renton Notice of Short Plats - Limelite Short Plat, LUA14-001083 & Cascade
Greens Short Plat, LUA001284
Solid. The neighborhood schools for this plat are: Cascade Elementary; Nelsen Middle School and Lindbergh High School.
Randy Matheson, Executive Director, Community Relations Renton School District 1300 SW 7th Street, Renton WA 98057 425.204.2345 (
'r
randv.matheson@rentonschools.us I www.rentonschools.us I Fag
ne:!n t
,...wir
From: Kris Sorensen [mailto:KSorensen@Rentonwa.gov]
Sent: Thursday, October 9, 2014 9:38 AM
To: Randy Matheson
Cc: Kayla Steckler; Sabrina Mirante
Subject: RE: City of Renton Notice of Short Plats - Limelite Short Plat, LUA14-001083 & Cascade Greens Short Plat,
LUA001284
An email reply for this one is great.
We will
work on an email template that should
be pretty easy to fill
out for
projects going forward. I believe Sabrina is
putting
something
together for future requests
like this that would
be fairly
simple.
Thanks for the reply.
Kris Sorensen, Associate Planner, Planning Division, Community &Economic Development City of Renton, 425-430-6593
From: Randy Matheson[mailto:randy.mathesonCalrentonschools us]
Sent: Thursday, October 09, 2014 9:36 AM
To: Kris Sorensen
Cc: Kayla Steckler
Subject: RE: City of Renton Notice of Short Plats - Limelite Short Plat, LUA14-001083 & Cascade Greens Short Plat,
LUA001284
Do you need us to download and fill out the form or can we simply provide you the information in returned email?
Randy
Matheson,
Executive Director,
Community
Relations
Renton School District
300 SW 7th
Street, Renton WA 98057 1425.204.2345
randy.matheson@rentonschools.us www.rent(
EXHIBIT 12
Edulog WebQuery
Page 1 of 1
User Information:
Address:11419 SE 162ND ST Back
Grade:
Program:
Select a School:
School Name School
Code
CASCADE ELEMENTARY CAS
NELSEN MIDDLE SCHOOL NEL
2016 PROPOSED NELSEN MIDDLE 2016NEL
SCHOOL
LINDBERGH HIGH SCHOOL LHS
SECONDARY LEARNING CENTER SLC
MEADOW CREST EARLY MCE
EDUCATION
School Web Eligibility Description Grades
Site
Within walk distance of 01, 02, 03, 04, 05, K2,
school K2A, K2P
Within walk distance of 06, 07, 08
school
Eligible 06, 07, 08
Eligible 09, 10, 11, 12, GD
Eligible 07, 08, 09, 10, 11, 12,
GD
EXHIBIT 13
Eligible
http://busroutes.rentonschools.us/edulog/webquery/WebQueryRequestController?address... 10/07/2014
cl
V/�410
My Comments concerning limelight short plat:
It would be nice to see less houses to allow for larger yards and more green
landscaping which would fit in better with the neighborhood. Cramped housing
means more traffic, noise and irritation to everybody. A larger play yard area
would keep kids from playing in the streets too.
This neighborhood is home to diverse wildlife. Mammals: (bats, deer, rabbits,
raccoons, oppossom, squirrels), birds: (chickidees, crows, doves, hawks,
hummingbirds, owls, robins, wrens), amphibians: (many tree frogs and
woodland newts) and beneficial insects like honeybees to name some
observed. Would like to see any development nature- friendly and also
protective of our wetlands and aqufiers. Any pollution up here eventually runs
downhill and effects the Duwamish watershed that eventually drains into our
treasured Puget Sound. We need green community corridors that support
nature and keep this area healthy and interesting for residents.
Retaining (planting more trees/shrubs helps prevent runoff and helps keep
noise and air pollution down. We do get plane noise here from Renton and
Seatac airports so more green space helps.
A storm retention pond surrounded by #encing is very unsightly (Like the one
located a block away, south (concrete pit and cyclone.fence= ugly). Perhaps a
rain garden or something more asthetic would be a better solution or just
leave the drainage ditch.
Hopefully any sidewalk put in won't narrow the road anymore like it did on
114th. When someone parks next to the sidewalk it impedes traffic.
Overall please consider keeping the character of the area green, natural and
a wonderful place for people and urban wildlife to live.
Thank You
Dana Cook and like-minded neighbors
AUG 26 2L'l4
EXHIBIT 14
PLAN REVIEW COMMENTS (LUA14-001083) cltyof
PLAN ADDRESS: 16204 114TH SE AVE APPLICATION DATE: 08/12/2014
RENTON, WA 98055-5249
DESCRIPTION: The applicant is requesting administrative Short Plat review of an R-8 zone, 29,912 sf corner lot, to be subdivided into 5 single family
residential lots. A storm water detention area would be located in the southwest corner of the site. Density would be 7.8 du/ac. The
existing home would be demolished. Vehicle access to proposed lots would be from SE 162nd St and 114th Ave SE for Lots 1-4, and for
Lot 5, there would be an easement across Lot 4 that provides connection to 114th Ave SE. Lot sizes range from 8,834 sf to 5,034 sf.
Studies submitted include tree inventory, geotechnical report, technical information report with drainage information, and landscape
analysis. Street improvements including planter strip and sidewalk would be installed along the subject site.
Engineering Review Jan Illian Ph: 425-430-7216 email: jillian@rentonwa.gov
Recommendations: EXISTING CONDITIONS
WATER Water Servicewill be provided by Soos Creek Water and Sewer District. A water availability certificate will be
required to be submitted to the City.
SEWER Sewer Service will be provided by Soos Creek Water and Sewer District. A sewer availability certificate will be
required to be submitted to the City.
STORM There are no drainage improvements in SE 162nd Street or in 114th Ave SE. There appears there is a ditch in
114th Ave SE.
Technical Services
STREETS There are no street improvements fronting the site in 114th Ave SE or SE 164th Street
CODE REQUIREMENTS
SURFACE WATER
1. A drainage report dated July 7, 2014, was prepared and submitted by Springline Design LLC. The report complies with
the 2009 King County Surface Water Manual and the 2009 City of Renton Amendments to the KCSWM, Chapters 1 and 2. Based
on the City's flow control map, the 5-lot short plat, zoned R-8 falls within the Flow Control Standard, Forested Condition. The
0.687 site has one existing home that will be demolished. The site is subject to Full Drainage. The engineer is proposing to
mitigate a portion of the new runoff created by the project by installing permeable pavement in lieu of the city's standard 5-foot
wide concrete sidewalk in the right of way. The city will not support the permeable pavement in the right of way.
2. A geotechnical report, dated March 19, 2014 was provided by PanGEO, Geotechnical Engineers. Five test pits were
excavated on March 19, 2014. Results show soils found one to five feet in depth were fine silty sands and sands. Test pits
excavated seven to eight feet deep. Results show were found to be glacial till and sandstone. Moderate to heavy groundwater
seepage was found one to five deep in all the pits.
3. Surface water system development fee is $1,228.00 for the new lot. Credit will be given to the existing home.
TRANSPORTATION/STREET
i. Existing right of way width in SE 162nd Street is 60 feet. Existing. right way of width in 114th Ave SE is 60 feet. Both streets
are classified as residential access roads. To meet the City's new complete street standards, street improvements including 13
feet of paving from centerline, curb and gutter, an 8-foot planter strip, a 5-foot sidewalk, and storm drainage improvements are
required to be constructed in the right of way fronting the site per City code 4-6-060.
2. Per City of Renton code, corner lots will be required to dedicate a minimum radius of fifteen feet (15').
3. Current traffic impact fee is $1,430.72 per new single-family lot. Payment of the transportation impact fee is due at the time of
issuance of the building permit. Credit will be given to the existing home.
4. Street lighting is required for a five lot short plat.
5. The maximum width of single loaded garage driveway shall not exceed nine feet (9) and double -loaded garage driveway
shall not exceed sixteen feet (16).
6. Driveway shall not exceed 15 % slope. Driveways over 8 % slopes require strip drains.
GENERAL COMMENTS
1. Separate permits and fees for storm connections will be required.
2. All construction utility permits for drainage and street improvements will require separate plan submittals. All utility plans
shall conform to the Renton Drafting Standards. A licensed Civil Engineer shall prepare the civil plans.
3. Rockeries or retaining walls greater than 4 feet in height will be require a separate building permit. Structural calculations
and plans shall be submitted for review by a licensed engineer. Special Inspection is required.
4. A tree removal and tree retention/protection plan and a landscape plan shall be included with the civil plan submittal.
Bob MacOnie Ph: 425-430-7369 email: bmaconie@rentonwa.gov
Recommendations: Preliminary Short Plat: Bob Mac Onie 09/22/2014
Note the City of Renton land use action number and land record number, LUA14-001083 and LND-20-0609, respectively, on the
final short plat submittal. The type size used for the land record number should be smaller than that used for the land use action
number
October 08, 2014 EXFIIBIT y C Page 1 of 3
The dedication of right of way for short subdivisions requires a separate Deed of Dedication; provide a space to the recording
number of same on the short plat. The Deed of Dedication document includes both a legal description exhibit and a map exhibit of
the dedicated parcel. The legal description exhibit should be prepared, stamped, dated and signed by the applicant's surveyor.
The surveyor should also prepare the map exhibit. The dedication process requires an updated Plat Certificate dated within 45
days of approval of said dedication. Talk to the Project Manager if there are questions or further information is needed.
now two ties to the City of Renton Survey Control Network. The geometry will be checked by the city when the ties have been
provided.
Provide sufficient information to determine how the plat boundary was established.
Provide short plat and lot closure calculations.
Note what was found when visiting the existing monuments.
Indicate what has been, or is to be, set at the corners of the proposed lots.
Note discrepancies between bearings and distances of record and those measured or calculated, if any.
The city will provide addresses for the proposed lots as soon as possible. Note said addresses on the final short plat drawing.
Do note encroachments, if any.
Do include a "LEGEND" block for the short plat drawing, detailing any symbols used thereon.
Note all easements, covenants and agreements of record on the drawing.
Note any relevant researched resources on the short plat submittal.
Note the plat.name and lot and tract numbers of the adjoining properties or note as "Unplatted.".
The City of Renton Administrator, PublicWorks Department, is the only city official who signs the final short plat. Provide an
appropriate approval block and signature line. Pertinent King County approval blocks also need to be noted on the drawing.
All vested owner(s) of the subject final short plat need to sign the final short plat drawing. Include notary blocks as needed.
Include a declaration block on the drawing, titled "OWNERS' DECLARATION" not "CERTIFICATION" or other.
Note that if there are easements, restrictive covenants or agreements to others (City of Renton, etc.) as part of this subdivision,
they can be recorded concurrently with the final short plat. The f nal short plat drawing and the associated documents) are to
be given to the Project Manager as a package. The recording number(s) for the associated document(s) are to be referenced
on the final short plat drawing. Provide spaces for the recording numbers thereof.
The new easements for ingress, egress, utilities, etc. shown for the benefit of future owners of the proposed lots each need a
note defining the rights associated with the easement at issue. Since these new "proposed" easements shown aren't "granted
and conveyed" until thebenefited and/or burdened lots are conveyed to others add the following language on the face of the
short plat drawing:
DECLARATION OF COVENANT:
The owners of the land embraced within this short plat, in return for the benefit to accrue from this subdivision, by signing
hereon covenant and agree to convey the beneficial interest in the new private easements shown on this short plat to any and
all future purchasers of the lots, or of any subdivisions thereof. This covenant shall run with the land as shown on this short
plat.
The preceding
statement obligates the
seller of the lots created to "expressly
grant and convey" the
lots "together with and/or
subject to" any
new private easements
delineated on the shod plat
in the conveying document.
The proposed 20' Access Easement shown over the south 20' feet of Lot 4 does not agree with the grading and paving plan.
The private ingress, egress and utility
(access) easement
requires a New Private Easement for Ingress,
Egress and Utilities
Maintenance Agreement" statement.
Reviewer Comments Leslie Betlach Ph: 425-430-6619 email: LBetlach@rentonwa.gov
Community Services Review Created On: 10108/2014
a. Parks impact fee per ORD 5670 applies.
b. There are no impacts to Parks.
c. planting strip between curb and sidewalk with street trees and groundcover or shrubs.
Planning Review Created On: 10/08/2014
October 08, 2014 Page 2 of 3
Planning:
1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless otherwise approved by
the Development Services Division.
2. Commercial, multi -family, new single family and other nonresidential construction activities shall be restricted to the hours
between seven o'clock (7:00) a.m. and eight o'clock (8:00) p.m., Monday through Friday. Work on Saturdays shall be restricted to
the hours between nine o'clock (9:00) a.m. and eight o'clock (8:00) p.m. No work shall be permitted on Sundays.
3. Within thirty (30) days of completion of grading work, the applicant shall hydroseed or plant an appropriate ground cover over
any portion of the site that is graded or cleared of vegetation and where no further construction work will occur within ninety (90)
days. Alternative measures such as mulch, sodding, or plastic covering as specified in the current King County Surface Water
Management Design Manual as adopted by the City of Renton may be proposed between the dates of November 1st and March
31st of each year. The Development Services Division's approval of this work is required prior to final inspection and approval of
the permit.
4. A National Permit Discharge Elimination System (NPDES) permit is required when more than one acre is being cleared.
5. The applicant may not fill, excavate, stack or store any equipment, dispose of any materials, supplies or fluids, operate any
equipment, install impervious surfaces, or compact the earth in any way within the area defined by the drip line of any tree to be
etained.
6. The applicant shall erect and maintain six foot (6) high chain link temporary construction fencing around the drip lines of all
retained trees, or along the perimeter of a stand of retained trees. Placards shall be placed on fencing every fifty feet (50')
indicating the words, "NO TRESPASSING — Protected Trees" or on each side of the fencing if less than fifty feet (50'). Site access
to individually protected trees or groups of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In
addition, the applicant shall provide supervision whenever equipment or trucks are moving near trees.
Fire Review -Building Corey Thomas Ph: 425-430-7024 email: cthomas@rentonwa.gov
Recommendations: Environmental Impact Comments:
1. The fire impact fees are applicable at the rate of $479.28 per single family unit. This fee is paid at building permit issuance.
Credit will be granted for the removal of the one existing home.
Code Related Comments:
1. The fire flow requirement for a single family home is 1,000 gpm minimum for dwellings up to 3,600 square feet (including
garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A
minimum of one fire hydrant is required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to
1,500 gpm. A water availability certificate is required from Soos Creek Water and Sewer District.
2: Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved, with 25-feet inside
and 45-feet outside turning radius. Fire access roadways shall be constructed to support a 30-ton vehicle with 322-psi point
loading. Access is required within 150-feet of all points on the buildings.
Police Review Cyndie Parks Ph: 425-430-7521 email: cparks@rentonwa.gov
Recommendations: Minimal impact on Police services.
October 08, 2014 - Page 3 of 3