Loading...
HomeMy WebLinkAboutR-4192128IRRIGATION LEGEND SYMBOL ITEM MANUFACTURER/CAT NO. © TWO WIRE DECODER RAINMASTER EGP—ETH—TW—S CONTROLLER ® AUTOMATIC RAIN SHUTOFF RAINMASTER RFS-1000 NO SYMBOL TWO WIRE DECODERS NO SYMBOL CONTROL WIRES NO SYMBOL SUGE PROTECTION O IRRIGATION METER AND STUB —OUT RAINMASTER TW—D-1 RAINMASTER POLYCOATED TWO WIRE SYSTEM RAINMASTER TW—LA-1 (2 ) (SYMBOLS SHOWN AT 1"=20'—O" DESCRIPTION -REMARKS TWO —WIRE DECODER CONTROLLER W/ COMMERCIAL GRADE STAINLESS STEEL ENCLOSURE. WALL MOUNT IN LOCATION AS SHOWN ON PLAN. VERIFY WITH ARCHITECT. INSTALL PER DETAIL 'B', SHEET L3.7. WIRELESS RAIN/FREEZE SENSOR WITH MOUNTING BRACKET, MOUNT ON ROOF PARAPET IN LOCATION SHOWN ON PLAN. OPERATION WILL BE TESTED AT PUNCH LIST REVIEW. PROVIDE AND INSTALL FOR EACH CONTROL VALVE SOLENOID, INSTALL PER MANUFACTURER'S RECOMMENDATIONS 14 AWG, 2 CONDUCTOR, SPLICES SHALL BE MADE USING 3M DBY-6 OR DBR-6 CONNECTORS. FOR LOOPING MAINLINE DESIGN, INSTALL TWO RUNS OF WIRE OUT FROM CONTROLLER, EACH A DIFFERENT COLOR JACKET, ONE IN EACH DIRECTION AND MEETING AT ISOLATION VALVE ON OPPOSITE SIDE OF SITE FROM CONTROLLER. PROVIDE RAINMASTER TW—LA-1 LIGHTNING ARRESTOR AND GROUNDING RODS PER MANUFACTURER'S RECOMMENDATION WITHIN VALVE BOXES. THE 2—WIRE PATH SHALL BE SURGE PROTECTED AND GROUNDED WITH TW—LA-1 EVERY 500 FEET OR EVERY 8 DECODERS, WHICHEVER IS SMALLER APPROXIMATE LOCATION. SEE CVIIL DRAWINGS. STRAINER WILKINS SXL CAST BRONZE 'Y' STRAINER (2") INSTALL AT POINT OF CONNECTION AS PER DETAIL 'A', SHEET L3.7. 1 BACKFLOW PREVENTER FEBCO 86OU (2") REDUCED PRESSURE BACKFLOW ASSEMBLY. INSTALL PER DETAIL 'A', SHEET L3.7. BACKFLOW ENCLOSURE STRONGBOX INSULATED ALUMINUM ENCLOSURE INSTALL ENCLOSURE ON CONCRETE PAD PER MANUFACTURER'S RECOMMENDATIONS. ON CONCRETE PAD WITH INSULATION COVER, MODEL #SBBC—xxALI, PROVIDE AND INSTALL WITH (2) COMBINATION LOCKS. INSTALL PER DETAIL 'A', SIZE AS REQUIRED. SHEET L3.7. POINT OF CONNECTION W GATE / SHUTOFF VALVE ® MANUAL DRAIN 0 QUICK COUPLER MASTER VALVE FLOW SENSOR Q BOOSTER PUMP SEE POINT OF CONNECTION ENLARGEMENT, DETAIL D, SHEET L3.9 HAMMOND, NIBCO, WILKINS GATE VALVE (2"), 200 PSI THREADED ENDS, BRONZE, SCREW IN BONNET, NON —RISING STEM, OR APPROVED EQUAL. SOLID WEDGE, INSTALL PER DETAIL 'C', SHEET L3.7. CHAMPION 30ORS-200 ANGLE VALVE (2") INSTALL AT POINT OF CONNECTION AS PER DETAIL 'A' AND 'D', SHEET L3.7. RAINBIRD #5RC INSTALL AT P.O.C. AND ELSEWHERE AS SHOWN ON PLANS, AS PER DETAIL 55K-1 KEY 'A' SHEET L3.7 AND DETAIL 'A' SHEET L3.8. PROVIDE (2) KEYS AND (2) SH-2 SWIVEL HOSE ELL ELLS. RAINBIRD EFB—CP SERIES VALVE (2") BRASS NORMALLY CLOSED MASTER CONTROL VALVE. INSTALL AT P.O.C. ASSEMBLY PER DETAIL 'A% SHEET L3.7. IRRITROL FSB—XXX BRASS FLOW SENSOR. FOR DECODER SYSTEM, INSTALL AND CONNECT TO CONTROL WIRE WITH RAINMASTER DECODER. SIZE TO ACCOMODATE FLOWS AS NEEDED BASED ON ZONES SHOWN HERE AND DESIGN/BUILT TEMPORARY ZONES INSTALL AT P.O.C. PER DETAIL 'C', SHEET L3.9. RAINBIRD CLP PUMP PACKAGE IRRIGATION BOOSTER PUMP ASSEMBLY SHALL BE A PREFABRICATED CLP WITH METAL ENCLOSURE SYSTEM WITH PUMP, PIPING, ELECTRICAL AND STRUCTURAL ELEMENTS, AND OTHER ITEMS AS REQUIRED FOR A COMPLETE SYSTEM AND SHALL BE OPERATIONAL FROM CONTROLLER. INSTALL WITHIN SPECIFIED METAL ENCLOSURE. INSTALL ON 4" CONCRETE SLAB. CONNECT PUMP START RELAY TO CONTROLLER AND PROGRAM AS REQUIRED FOR FULL OPERATION. INSTALL PER DETAIL 'A' AND 'B' ON SHEET L3.9. SEE SHEET L3.9 FOR ADDITIONAL BOOSTER PUMP ASSEMBLY NOTES. CONTROL VALVE RAINBIRD XXX—PEB—PRS—O PLASTIC CONTROL VALVE WITH PRESSURE REGULATING SIZE AS SHOWN ON PLAN. DIAL, INSTALL PER DETAIL 'B', SHEET L3.8. IWEISMANDESIGNON nPLI�GROUP �AMCHffFLANDACNpF 3S9EM�IN12 P/WWM9OHUOM SYMBOL ITEM MAINLINE LATERALS SLEEVES w SHUT—OFF / ISOLATION VALVE Volvo calloot J! y Valve Number p R Valve Flaw Valve size MANUFACTURER/CAT NO. DESCRIPTION -REMARKS PVC —SCHEDULE 40 3" MINIMUM UNLESS OTHERWISE NOTED ON PLAN. INSTALL PER DETAILS 'D' ON SHEET L3.8 AND 'E' ON SHEET L3.09. PVC —SCHEDULE 40 SIZE AS PER PLAN, 3/4" MIN. UNLABELED PIPE SECTIONS TO MATCH THE LARGEST OF THE ADJACENT PIPES. UNLABELED PIPE AT THE END OF LATERAL RUNS TO BE 3/4". INSTALL PER DETAIL 'D', SHEET L3.8. PVC —SCHEDULE 40 4" MINIMUM SIZE UNLESS OTHERWISE NOTED ON PLAN. INSTALL WHERE INDICATED ON PLAN. DEPTH AS REQUIRED BY PIPE WITHIN. INSTALL PER DETAIL 'D', SHEET L3.8. WATTS GV OR GVS 200 PSI THREADED ENDS. INSTALL AT POINT OF CONNECTION AND ELSEWHERE SHOWN ON PLAN PER DETAIL 'C'. SHEET L3.7. SIZE TO MATCH MAINLINE SIZE. SEE VALVE SCHEDULE ON THIS SHEET ®®® POP—UP FIELD ROTOR TORO T7PSS-02 #07 (6.6 GPM) R=46' #09 (T4 GPM) R=47' #12 (9.5 GPM) R=50' FIELD SPORTS ROTOR WITH STAINLESS STEEL RISER. 40 PSI. ADJUST RADIUS AS REQUIRED. INSTALL PER DETAIL 'E', SHEET L3.8. ® ®® POP—UP SPRAY HEAD TORO 570ZPR 15 SERIES 30 PSI, ADJUST RADIUS AS REQUIRED, INSTALL PER M 4 1f (570Z-4P—PR = LAWN) DETAIL 'F', SHEET L3.8. • M � TORO 570ZPR STRIP SERIES 30 PSI, ADJUST RADIUS AS REQUIRED, INSTALL PER 9I& &JA POP—UP SPRAY HEAD (570Z-4P—PR = LAWN) DETAIL 'F', SHEET L3.8. TORO 570ZPR 15 SERIES 30 PSI, ADJUST RADIUS AS REQUIRED. INSTALL PER Q�©Q©® POP—UP SPRAY HEAD 'F', TO F (570Z-06P—PR = SHRUB) DETAIL SHEET L3.8. ©e IQQO I2 POP—UP SPRAY HEAD TORO 570ZPR 12 SERIES 30 PSI, ADJUST RADIUS AS REQUIRED, INSTALL PER o T H n TO F (570Z-06P—PR = SHRUB) DETAIL 'F', SHEET L3.8. Q ollopp® TORO 570ZPR 10 SERIES 30 PSI, ADJUST RADIUS AS REQUIRED, INSTALL PER POP—UP SPRAY HEAD o T H Tr TO F (570Z-06P—PR = SHRUB) DETAIL 'F', SHEET L3.8. ® TORO 570ZPR 8 SERIES 30 PSI, ADJUST RADIUS AS REQUIRED, INSTALL PER 0 � ID 0 POP—UP SPRAY HEAD (570Z-06P—PR = SHRUB) DETAIL 'F', SHEET L3.8. qqqq TORO 570ZPR STRIP SERIES 30 PSI, ADJUST RADIUS AS REQUIRED, INSTALL PER ® a9r�p o35T s� POP—UP SPRAY HEAD 'F', zssT a`vST as�sr (570Z-06P—PR = SHRUB) DETAIL SHEET L3.8. SEEDING IN PERIMETER SITE AREAS SHALL BE TEMPORARY IRRIGATION TEMPORARILY IRRIGATED. CONTRACTOR SHALL PROVIDE ADDITIONAL HEADS, PIPING, VALVES DECODERS AND WIRES FOR DESIGN/BUILD TEMPORARY IRRIGATION SYSTEM AT NO ADDITIONAL COST TO THE OWNER, AND MONITOR/MAINTAIN TEMPORARY SYSTEM DURING MAINTENANCE PERIOD. PLANTING IN MITIGATION AREAS IN WETLAND SHALL BE TEMPORARY IRRIGATION TEMPORARILY IRRIGATED PER WATERSHEDS WETLAND MITIGATION PLANS, SPECIFICATIONS AND NOTES. CNowom o/lowl °RWAY. KC � DATUM 7" `1aw N0. REVISION BY DATE APPR TY F NOT ONE NCR na v" ""°'�""" 0 CITY OF RENTON Planning/Building/Public Works Dept, SCALE: 1"=20'-0" Z 0' 10' 20' 40' 80' R-4192127 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING msippo 04/13/2022 ' NEW ELEMENTARY SCHOOL #16 CHELAN AVE NE RENTON, WA 98059 IRRIGATION LEGEND Q0 O O O N a J rn O O O O O NN LL a O) OJ N V O O N i+ W r LU w 2 U boom 04 MAR 2022 O 0 aoo K L3.6 W