HomeMy WebLinkAboutR-4192131BOOSTER PUMP
DOWNSTREAM OF
BACKFLOW AND
P.O.C. COMPONENTS,
BUT UPSTREAM OF
MASTER VALVE
FINISH O'-6"
GRADE
9YE7LCIRI�NIa
ADAPTER
BOOSTER PUMP AT POC
FLOW SENSOR
WITH TEE
FINISH GRADE
MAINLINE
FOR CONVENTIONAL)
SYSTEM, INSTALL
CONDUIT WITH PE-89
CABLE TO CONTROLLER
ELEVATION VIEW
BOOSTER PUMP
SEE IRRIGATION LEGEND,
NOTES, AND DETAIL
INSTALL CONNECTIONS
THROUGH SLAB WITH
POWDER COATED STEEL
PIPES, SIZED TO
MATCH MAINLINE
PROVIDE NECESSARY
POWER CONNECTIONS
AND CONDUITS
PROVIDE WIRE CONDUIT
TO CONTROLLER FOR
PUMP START RELAY
4" DEPTH CONCRETE SLAB
OVER 2" COMPACTED CRUSHED
ROCK BASE, SIZE TO PROVIDE
6" CLEARANCE BEYOND
ENCLOSURE. ENSURE POSITIVE
DRAINAGE FROM SLAB.
ELEVATION VIEW
RAIN BIRD
LP SERIES
ENCLOSURE
DEPICTED
\ ` MAINLINE
�\ ADAP TER-'----
SPECIFIED RECTANGULAR VALVE
BOX, INSTALL FLUSH WITH
FINISH GRADE
SPECIFIED CONTROL WIRES
Sk SPLICE KITS
INSTALL DECODER FOR TWO -WIRE
SYSTEM AND PULSE TRANSMITTER
ON CONVENTIONAL SYSTEM
wI I -I IIITIC
00
T RUN OF PIPE5X PIPE A.
G-SUPPORT VALVE BOX
WITH (4) BRICKS
INSTALL 6" DEPTH MIN. OF
DRAIN ROCK IN BOTTOM OF
VALVE BOX. EXTEND ROCK
6" BEYOND VALVE BOX
NOTES:
1. INSTALL FLOW SENSOR AS PER THE MANUFACTURER'S RECOMMENDATIONS.
2. PROVIDE VALVE BOX EXTENSION AS REQUIRED.
3. INSTALL FLOW SENSOR PERFECTLY PLUMB.
FLOW SENSOR
Scale: 1 112"=1'-0'
Scale: 1 112"=l'-O'
WEISMANDESIGNGROUP
�NPDIONn 6-M-17MUNOSGPF MMWA9112 sivimcmai
M 9MCHRECNpE y y0 ,��'�,•
c,eE%p B�aox''4 NO. REVISION
I J j Y H
TYPICALSTANDARDDR
NOTE: CONTRACTOR SHALL PROVIDE LARGER I
SERIES ENCLOSURE IN LIEU OF STANDARD Cl
SERIES ENCLOSURE SHOWN HERE AND ROUTE INTAI
AND DISCHARGE PIPES THROUGH BOTTOM I
ENCLOSURE NO PIPES SHALL BE ALLOWED TO ISO
OR ENTER SIDES OF ENCLOSUS
CONTRACTOR SHALL PROVIDE AND INSTALL A -
DEPTH CONCRETE SLAB, SIZED TO BE 6' BEYOND
CLEARANCES OUTSIDE OF ENCLOSURE
3 NP HORIZONTAL
END-SUCTIRI POW
NOTE N CONTRACTOR SHALL PROVIDE
LARGER LP SERIES ENCLOSURE IN LIEU
OF STANDARD CLP SERIES ENCLOSURE
NOTES: SHOWN HERE AND ROUTE INTAKE AND
L SLAB DETAIL IS PROVIDED FOR ILLUSTRATION ONLY, THE ARCHITECT OR PROJECT DISCHARGE PIPES THROUGH BOTTOM IT
ENGINEER SHOULD BE CONSULTED FOR CONSTRUCTION DETAIL. ENCLOSURE NO PIPES SHALL PE
2. DIMENIONS ARE FOR REFERENCE ONLY. EXTERNAL PLUMBING TO PE FIELD FIT, ALLOWED TO EXIST OR ENTER SIDES ff
3. STATION WEIGHS - 250 LES, ENCLOSURE.
0 1 T 1 A
1v/ POC ENLARGEMENT
0'-6" TYP.
CLEARANCE
CONTROLLER SHOWN IN IMAGE VILL
INCLUDED FOR THIS PROJECT, COST
BE INSIDE BULLMIC AS SHOWN ON F
CONTRACTOR SHALL PROVIDE WIRE T
FOR POW START RELAY - CONNECT AND PROGRAM
AS REQUIRED FUR FULL OPERATION.
DISCHARGE
PRESSURE GAUGE
INTAKE
STANDARD GRAVING "'Akk!-x'°•f�,
"I
P A
°"" CITY OF
MENNEN"'"" KG RENTON
� � DATUM
CHDCKENTY Planning/Building/Public Works Dept,
BY DATE APPR na v" A"°'u"`L`
L
P
Scale:
R4192130
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING O
msippo 04/13/2022
NEW ELEMENTARY SCHOOL #16
CHELAN AVE NE
RENTON, WA 98059
IRRIGATION DETAILS