HomeMy WebLinkAboutR-419283C%j
c%j
0)
(E) UTILITY POLE
0
F!7
0
of
Lij
(E) UTILITY
THREE-PHASE
OVERHEAD
DISTRIBUTION
Z)
CHELAN "E NE
N EW TH REE�%,, SE
\-�E I W/
UPTILL12MOUNT
N REI
AD TIL
OVERHEE. Y
E�
�P A�SE
DE TH
OVERTHHEE. A IL
DISTRIBUTION BY PSEf
XFMRTOREMAIN
DISTRIBUTED
--(E) SERVICE
_(E) SERVICE
,(E) UTILITY
(SE) CAW AND
THREE-PHASE
ERVICE AER
OVERHEAD
To REMAIN
DISTRIBUTION
(E) STREET
LUMINAIRE (TYP OF 2)
(E) TELEPHONE
— PEDESIFNL�
E) STREET LIGHTING
HANDHOLE (TYR)
�E) UTILITY POLE W/ (E)
r OLE-MOUNT XFMR
0
LSIGMUZA
E) ION
PEDESTAL
—(E) UTILITY
THREE-PHASE
OVERHEAD
DISTRIBUTION
Istyl-I
JT_l I
*) If
(E)
WEATHERHEA
(E) SERVICE77
SERVICE - CAW
(E) OVERHEAD
SERVICE LATERAL
POWER
SERVICE CAT
(E) OVERHEAD
SERVICE LATE
POWER
(E) UTILITY POLE
[(E) UTILITY POWER
METER
(E) SERVICE 1 2
�_ A(E)OVERHEAD
SERVICE LATERAL
POWER & TV
(E) STREET
UMINAIRE (TYR OF 2) E) UTILITY
ZZY
0`�� �477U71U 7RAIRY
M7
L
XBY�
IFURWICLIIIE Y� L
YCO T
_131-7 INSTALLED BY CONT TOR -
?"I r�z *1
i If
1 2:CC - POWER
�2 POWER
E
U
'110
ki
—(1) vC
(1) 1"C
PR
A 69
1, J11
L
JIM
%7"A
I -sing
U UTILIW JUNCTION VAUI
TILT
U URNISHED BY UTILITY
ST�
:jN.STM_LED BY CONTRA
rF—AC—PI
VC - FUTURE EV
�RGING STATIONS
"C - READERBOARD
NEW RENTON
LEMENTARY
HOOL#16
V3 1\(2)1'C LIGHTING
-0 PIV
E5 /�VCT GENE
_131 8 (Z(:Z 0
FACP
E - "K
y0mm al 6
0
0
z
z
FG
"110 142
1 .10
2
T ty CONTROLLER ON
f �SEREETES 42
NT E2
1-12
+
+
l> IRRIGATION
&BOOSTER PUMP
VAULTSCHEDULE
UILIVALL AVE=. NE
VAULT TYPE
MANUFACTURER
VAULTMODEL
COVERMODEL
COVER RATING
COVER LABEL
VAULT DIMENSIONS
(L X W X D)
NOTES
vi
V2
OLDCASTLE
444-EL
44-332P
MEDIUM DUTY H-20 OFF STREET
4�-()" X 4'-On X 4'-Gw
V3
OLDCASTLE
B1324 BOX
N1324-51JH
HEAVY DUTY: H-20 ROADWAY
ELECTRIC
29-112" X 18-3/4" X 12"
V4
OLDCASTLE
233-BL
23-2436P
MEDIUM DUTY: H-20 OFF STREET
ELECTRIC
3�80 X 2'-EP X 3-6"
V5
OLDCASTLE
TYPE-1
MEDIUM DUTY: H-20 OFF STREET
LT
22"Xl7"XlZ`
1
NOTES
1.
2.
3.
COORDINATE WITH CITY OF RENTON REQUIREMENTS STANDARDS 119,120.
I
A
A
z
I I �111� wn 'm
i lmlwl� I" H OL lqa�jlwl
KSR
DATUM
HEC;� DT; ATMIL
IF NCYF � 1�
Vp��
vP�D 50'IS Msi"Xy
REVISION 4 a
NO, By DATE APPR al 4
SHEET NOTES:
1. REFER TO CIVIL, LANDSCAPE AND SURVEY DRAWINGS FOR ADDITIONAL INFORMATION.
2. COORDINATE PLACEMENT OF SITE LIGHTING, VAULTS AND RACEWAY WITH DIVISION 31, CIVIL AND DIVISION 32,
LANDSCAPE CONTRACTORS. COORDINATE WITH TREE PROTECTION PLANS AND AVOID CRITICAL ROOT ZONES OF
EXISTING TREES. CONFLICTS SHALL BE COMMUNICATED TO THE ARCHITECT FOR RESOLUTION PRIOR TO
COMMENCEMENT OF SITE WORK.
3. COORDINATE ELECTRICAL UTILITY SERVICE AND OFF -SITE UTILITY ELECTRICAL WORK WITH PUGET SOUND ENERGY
PRIOR TO COMMENCING WORK. INSTALLATION SHALL COMPLY WITH POWER COMPANY'S ELECTRICAL INSTALLATION
REQUIREMENTS. CONTACT TIN NGUYEN WITH PUGET SOUND ENERGY AT 253-2444303, TIN NGUyEN@PSE.COM FOR
ADDITIONAL REQUIREMENTS.
4. MINIMUM CONDUIT SIZE SHALL BE 1 INCH. MINIMUM CONDUCTOR SIZE SHALL BE #10 AING FOR BRANCH CIRCUIT WORK
SHOWN ON THIS SHEET.
5. PROVIDE #B AWG CONDUCTORS FOR LIGHTING BRANCH CIRCUIT WORK SHOWN ON THIS SHEET.
6. PROVIDE A WATER -TIGHT SEAL FOR EACH UNDERGROUND RACEWAY ENTERING THE ELECTRICAL ROOM AFTER
CONDUCTORS HAVE BEEN INSTALLED. REFER TO RACEWAY SPECIFICATION SECTION 260533 FOR ADDITIONAL
INFORMATION.
7. REFER TO ONE -LINE DIAGRAM ON SHEET E9.01 FOR ADDITIONAL INFORMATION.
B. ROUTE SITE LIGHTING CIRCUITS TO PANELS INDICATED VIA ASSOCIATED LIGHTING CONTROL PANELS. REFER TO E2
SERIES DRAWINGS FOR SITE LIGHTING CONTROL REQUIREMENTS. PROVIDE WIRING AND CONTROL DEVICE
FOR COMPLETE SYSTEM.
9. INSTALL UNDERGROUND CONDUIT PER TRENCHING DETAIL. REFER TO DETAIL 3, SHEET E7.03.
10. PROVIDE CONCRETE BASE FOR SITE LIGHTING POLES. REFER TO DETAILS 1 AND 2, SHEET E7.03 FOR ADDITIONAL
INFORMATION.
11. REFER TO VAULT SCHEDULE ON THIS SHEET FOR VAULT AND HANDHOLE TYPES. REFER TO SPECIFICATION
SECTION 21 FOR ADDITIONAL INFORMATION.
12. PRIMARY CABLING IS PROVIDED BY UTILITY.
FLAG NOTES:
COORDINATE RECONINECTION OF EXISTING SERVICES TO REMAIN FROM DEMOLISHED UTILITY POLE
TO BE FED FROM NEW RELOCATED POLE -TOP TRANSFORMERNTILITY PRIMARY.
NEW CONDUCTORS PROVIDED BY UTILITY TO RECONNECT EXISTING SERVICES TO REMAIN.
MATERIAL SHALL BE FURNISHED AND INSTALLED BY UTILITY FROM EXISTING UTILITY POLE TO
SERVICE POINT. PROVIDE EXCAVATION, TRENCHING, AND BACKFILL REQUIRED BY UTILITY. SEE
ONE -LINE DIAGRAM FOR ADDITIONAL INFORMATION.
UTILITY SHALL PROVIDE REFEED OF PRIMARY SIDE OF EXISTING POLE -TOP TRANSFORMER.
COORDINATE FINAL LOCATION WITH LANDSCAPE.
T-419206
C)
U�_ Zi4
0)
00
N
,It
c:)
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
c/)
z
Lu
ILL
0
CITY OF NEW ELEMENTARY NO. 16
PENTON CHELAN AVE NE
RENTON, WA 98059
Planning/Building/Public Works Dept. ELECTRICAL SITE PLAN
w
1 83 1471 (L