HomeMy WebLinkAboutR-419288cq ii 0 Lu SHEET NOTES: 1 . REFER TO CIVIL, LANDSCAPE AND SURVEY DRAWINGS FOR ADDITIONAL INFORMATION. 2. COORDINATE PLACEMENT OF SITE LIGHTING, VAULTS AND RACEWAY WITH DIVISION 31, CIVIL AND DIVISION 32, LANDSCAPE CONTRACTORS. COORDINATE WITH TREE PROTECTION PLANS AND AVOID CRITICAL ROOT ZONES OF EXISTING TREES. CONFLICTS SHALL BE COMMUNICATED TO THE ARCHITECT FOR RESOLUTION PRIOR TO COMMENCEMENT OF SITE WORK. 2. REFER TO LANDSCAPE SHEETS TP1.00 AND TP1.01 FOR TREE PROTECTION & REMOVAL PLANS. ELECTRICAL EQUIPMENT, RACEWAY AND VAULTS ARE TO BE LOCATED ANDIOR ROUTED OUTSIDE OF TREE PROTECTION FENCE BOUNDARIES. 3. INSTALLATION OF CONDUITS AND VAULTS SHALL INCLUDE BUT NOT LIMITED TO TRENCHING, BACKFILL, TAMPING OF EARTH, DETECTABLE MARKER TAPE AND WHERE INDICATED CONCRETE ENCASEMENT. 4. CONDUITS SHALL BE ENCASED WITH CONCRETE WHERE PASSING UNDER BUILDING FOUNDATIONS AND AT STREET/ PARKING LOT CROSSINGS. EXTEND ENCASEMENT 60" ON EACH SIDE OF CROSSING. 5. WATERTIGHT SEAL SHALL BE PROVIDED FOR EACH CONDUIT INSIDE THE VAULT AND WITHIN THE BUILDING AFTER BACKBONE] DEMARC CABLING HAS BEEN INSTALLED. SEE SPECIFICATION SECTION 271100 FOR ADDITIONAL INFORMATION. 6. COORDINATE TELEPHONE AND OWNER WAN SERVICE ENTRANCE CONDUITS WITH SERVICE PROVIDER PRIOR TO COMMENCING WORK. CONTACT JASON TESDAL W/ CENTURYLINK 206.345.3488 TO COORDINATE PHONE SERVICE ENTRANCE. 7. COORDINATE CONNECTION OF STORM SEWER TO TELECOMMUNICATIONS SYSTEM VAULTS WITH CIVIL TO AVOID WATER INFILTRATION INTO INTERIOR TELECOMMUNICATIONS ROOMS. 8. INSTALL UNDERGROUND CONDUIT PER TRENCHING DETAIL. REFER TO DETAIL 3, SHEET E7.03. 9. REFER TO VAULT SCHEDULE ON THIS SHEET FOR VAULT AND HANDHOLE TYPES. FLAG NOTES: PROVIDE (4) 4" SCHEDULE-40 PVC CONDUITS WITH MULE TAPE TO THE MDF AT 36" BELOW GRADE SERVICE ENTRANCE CONDUITS ARE AS FOLLOWS' (1)4"CTELEPHONE (1)4'C CATV (1)4"C WAN (1)4'C SPARE PROVIDE 10'.0" GALVANIZED RIGID STEEL SERVICE ENTRANCE RISER CONDUITS ON (E) UTILITY POLE WITH STANDOFF BRACKETS AND CAP. SERVICE ENTRANCE CONDUITS ARE AS FOLLOWS: (1)4"C TELEPHONE (1)4"C CATV (1)4'C WAN (1)4"C SPARE D�> PROVIDE THE FOLLOWING SCHEDULE 40 PVC CONDUITS WITH MULE TAPE AT 36" BELOW GRADE (1)4"C TELECOMMUN ICATIONS W/ (3) 1" IN NERDUCTS (1)4"C INTERCOM I CLOCK (1)4"C SECURITY (1)4"C SPARE PROVIDE PENCELL PEMI GRADE LEVEL BURIED HANDHOLE WITH MINIMUM 6"GRAVEL BASE. INSTALL PER MANUFACTURER RECOMMENDATIONS. PROVIDE THE FOLLOWING SCHEDULE 40 PVC CONDUITS WITH MULE TAPE AT 36" BELOW GRADE: (2)2"C TELECOMMUN ICATIONS FROM DIE THE FOLLOWING SCHEDULE 40 PVC CONDUITS WITH MULE TAPE AT 36" BELOW GRADE: (1)2"C TELECOMMUN ICATIONS PROVIDE (1)1-C TO LIGHT POLE FOR FUTURE IF CAMERA. COORDINATE LIGHT POLE TYPE AND LOCATION WITH ELECTRICAL DRAWINGS. VAULTSCHEDULE VAULT DIMENSIONS VAULT TYPE MANUFACTURER VAULT MODEL COVER MODEL COVER RATING COVER LABEL RISERS NOTES L X W X D) Tl OLDCASTLE �-332P MEDIUM DUTY: H-20 OFF STREET CENTURYLINK 3X2'X3' T2 OLDCASTLE 444-LA 44-332P MEDIUM DUTY: H-20 OFF STREET COMCAST N? �X T3 OLDCASTLE 44-332P MEDIUM DUTY: H-20 OFF STREET WAN 3' X 2� T4 OLDCASTLE 233-LA 23-2436P MEDIUM DUTY H-20 OFF STREET COMMUNICATIOW SIX ZX 3' NOTES 1. PROVIDE CABLE RACKING 2. 3. I I �111� wn 'm i lmlwl� 1" 40'-0" H OL lqaVlwl VR vl� I DATUM �01 1 1 VR IF NCYF � 1� NO, REVISION BY DATE APPR vP�D .� CITY OF RENTON Planning/Building/Public Works Dept. T-419211 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NEW ELEMENTARY NO. 16 04 MAR 2022 CHELAN AVE NE OIIs�E RENTON, WA 98059 :Z� TELECOM SITE PLAN I I E 88 147 C) -9 7 IN 0) DO N ,It c:) CID c/) z LL] 0 0 F— W� 79 Tr III