EX. SEWER SEWER MAIN
l
PROPERTY LINE
i i i z
��-SPOOL
(LENGTH AS NEEDED)
i I i I I
3'-0" MIN
6" SEWER STUB
I I I O I
I I I ;;�
FUTURE 4" SIDE SEWER
I I I I
I I I I
2% 4" STUD MARKING POST PAINTED
C CAP WHITE WITH THE WORD "SEWER" STENCILED
SEWER MAIN TEE , 6" TEEi
i i i I
IN 3" HIGH BLACK LETTERS AND k6 WIRE
SIDEWALK i z
WRAPPED AROUND THE STUD AND
w\
I I I I
EXTENDED TO THE TOP OF THE STUD
COUPLING (TYP)
rl
L_J_L_________J Q
I;
I
6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER
0
I
(EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR
I �
APPROVED EQUAL, SPECIFY "SEWER" ON LID),
E
CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD
CONCRETE PAD TO BE WIN DEPTH
rT__-___-__
-----------------------,--� r-------
---J
BEND AS
8"
REQUIRED
EXISTING SANITARY
_
SEWER MAIN ..
s .,m SLOPE
-�
'6" SEWER STUB 6"X6"X6" WYE �-FUTURE 6"x a" REDUCER
`SEWER MAIN SIZE X 6" TEE
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN
A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL)
C PVC h C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE
(OR APPROVED EQUAL)
0. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL)
E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING
"STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
F HDPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER
G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE
SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL
NOTES.
i PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT
2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER
3 SIDE SEWERS SHALL HAVE A MINIMUM 2 X SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR
4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE
SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT
THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102
6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405
7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON
SIDE SEWER STUB p���u STD PLAN -406"1
PUBLIC WORKS APPROVED'-"
-� DEPARTMENT INSTALLATION Martin PaStUCl%@V26/202
(SEWER MAIN TO PROPERTY LINE) a¢B�swTDseea490 DATE
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
20"
24"
c1
2 1/2" DIA. HOLE
/ L
O
I
' o0000o I I
00�04�0�
O�O�O�O�O BOLT -DOWN SLOT DETAIL
�O�O O�OO L___ SEE NOTE I ___L
m 3"
TOP
ISOMETRIC
I
71 2"
L BOLT -DOWN SLOT,
314"
SEE DETAIL AND
NOTE 1 i 1 1/4" 1
1 518" 1
4 314" 1 112"
SECTION B
1 5/8" MAX.
3"
R39", SEE NOTE 2
SECTION A
126". SEE NOTE 2
1 12
5„
NOTES:
3/4"
i 5/8"
1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES,
GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED.
PROVIDE TWO HOLES IN THE FRAME THAT ARE
VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS.
THE FRAME SHALL ACCEPT THE 5/8"A 1 NC x 2" ALLEN
4"
HEAD CAP SCREW BY BEING TAPPED, OR OTHER
II` 3/4" DIA. HOLE
APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES
VARIES BY MANUFACTURER.
112"DIA. HANDLE
2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN
LIEU OF THE RIB DESIGN.
SECTION C
3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR
ADDITIONAL REQUIREMENTS.
4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD
PLAN 204.00.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 204.10
PUBLIC WORKS
�I` DEPARTMENT
RECTANGULAR SOLID
METAL COVER
9/28/2018
a
vublic Warks AdminbVat"r DATE
CONSTRUCTION RECORD
DRAWING:
AS -BUILT INFORMATION FOR
RECORD DRAWINGS PROVIDED
BY TERRANE, JULY 2023.
THIRD DAY DESIGN
CIVIL ENGINEERING
5918 WALLER RD E
TACOMA, WA 98443
(253) 256 1812
:45 AN
13%24" PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC,
INC. BCF SERIES MSBCF 1324-18 WITH 1.75" THICK DUCTILE
IRON DIAMOND PLATE COVER EQUAL TO MID -STATES PLASTICS,
INC. MSCBC-1324-R WITH READER LID AND 2" DRILLED HOLE
FOR TOUCHREAD PIT LID (SEE DETAIL A -A)
9" MIN
12" MAX
FINISH GRADE
�Qw
O
36" MIN COVER
N o
NEW DUCTILE
IRON
WATERMAIN
CITY
PIPING
z I
IN UNIMPROVED RIGHT OF z
J
WAY INSTALL METER BOX AT J
PROPERTY LINE WITH 12"
w
LONG COPPER TAILPIECE.
ofI
SIDEWALK a
TOUCHREAD WATER
METER TO BE
PRIVATE
PIPING
FSUPPLIED BY THE 12 E a
CITY � >
TYPE "K" SOFT ` o O
COPPER TUBING
IF SERVICE LINE TO HOUSE IS
TO BE INSTALLED IN THE FUTURE
INSTALL FORD C14-33 OR 44 FIPT
x COMPRESSION COUPLING
LOOP DOWN TO CENTERLINE
OF WATER MAIN TO
PROVIDE SLACK IN COPPER ZCOPPERSETTER FOR 5/8"x3/4" METER: FORD
SERVICE LINE TO METER. V5H72-15W-44-33G, OR McDONALD BRASS: 21-215WCQ033, OR
MUELLER: 3/4-8-2470-2 WITH ANGLE BALL VALVE ON INLET AND
SINGLE CHECK VALVE ON OUTLET
CORPORATION STOP WITH BALL VALVE. FORD COPPER SETTER FOR 1" METER: FORD VBH72-15W-44-44G, OR
TAPERED THREAD (CC). QUICK JOINT McDONALD BRASS: 21-415WCQQ44, OR MUELLER: 1-B-2470-2
(3/4" FB1000-3-Q) OR AY MCDONALD 4701B BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON
(1" FB1000-4-Q) OR AY MCDONALD 4701B INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET.
ALL FITTINGS SHALL BE WITH QUICK JOINT.
NOTE:
ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE
CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUSH BE INSTALLED ON
BOTH SIDES OF METER BOX.
A- DRILL 2" DIA. HOLE FOR AMR (AUTOMATIC
METER READ) TOUCHREAD DEVICE
L 2-1/2" MIN. FROM NEAREST
AND FRONT EDGE OF PIT LID
TYPICAL
RIB
I
3/4" OR 1"
GALVANIZED
PLUG
NOTE:
THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM
UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE
NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN
ONE RIB,
34" AND 1" WATER SERVICE STD. PLAN - 320.1
+ + PUBLIC WORKS
DEPARTMENT
NOVEMBER 2009
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
ISOMETRIC
Q
BOLT -DOWN SLOT, 112"
SEE DETAIL AND
NOTE 1
I � I
5/8"
I I [
I I
1
BOLT -DOWN SLOT DETAIL
L _ _ _ SEE NOTE 1
LETTERING
SECTION B
NOTES:
1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND
COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN
THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR
COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"A 1 NC x 2" ALLEN
HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED
MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY
MANUFACTURER.
2. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL
REQUIREMENTS.
3. FOR FRAME DETAILS, SEE STANDARD PLAN 204.00.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
RA STD. PLAN - 204.20
• PUBLIC WORKS PRO :
DEPARTMENT RECTANGULAR VANED GRATE GAZ 9/28/2018
P"brcw hAtlmimro„", DATE
WA P S 8/14/2023
pF Sh "I
44221
CEO/ STF
SSIONAL
NO.
REVISION
:45 AN
11" 2" 4", 6", 12", OR 24"
ONE #3 BAR HOOP FOR 6" HEIGHT
INCREMENT (SPACED EQUALLY),
SEE NOTE 1
RECTANGULAR ADJUSTMENT SECTION
d0•S�6
E�
26 5
�Q, C A
#3 BAR EACH CORNER 1
sFFh�,
�OTF�
#3 BAR EACH SIDE },).• Y�
e
#3 BAR EACH WAY
PRECAST BASE SECTION
#3 BAR HOOP
#3 BAR EACH
CORNER 18" MIN.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
Ar% PUBLIC WORKS
DEPARTMENT
%d
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR PLAIN
12"
CONCRETE
ALL METAL PIPE
15"
CPSSP`,
STD. SPEC. 9-05.20
12"
SOLID WALL PVC,
STD. SPEC. 9-05.12(1)
15"
PROFILE WALL PVC,
STD. SPEC. 9-05.12(2)
15"
`CORRUGATED POLYETHYLENE STORM
SEWER PIPE
NOTES:
1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN
IN THE PRECAST BASE SECTION, FIBERS (PLACED IN
ACCORDANCE WITH STANDARD SPECIFICATION
9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF
0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH
THE MINIMUM REQUIRED REBAR SHOWN IN THE
ALTERNATIVE PRECAST BASE SECTION. WIRE MESH
SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN
ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN
THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH
HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER
FOOT MAY BE USED.
2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER
THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS
OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5"
MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE
OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED,
FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-04.3.
3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO
THE LOWEST PIPE INVERT SHALL BE 5 FEET.
4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE
FLANGE DOWN.
5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED
FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF
1H:24V OR STEEPER.
6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE
PRECAST BASE SECTION.
7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE
INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR
NON -SHRINK APPLICATIONS IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-20.3(2).
8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN
MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE
AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND
FRAMES.
9. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 200.00
APPROVED
CATCH BASIN TYPE 1 GAZ 9/28/2018 1
rw"M: Aammi:n.wr DATE
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
CATCH BASIN FRAME AND VANED
GRATE PER STD. PLAN 204.00
RECTANGULAR OR CIRCULAR ADJUSTMENT
SECTION (TWO SECTIONS MAX.)
MORTAR, (TYP.), SEE NOTE 5
4" MIN.
28" MAX, 16" MAX. FLAT SLAB TOP
48", 54", 60", 72•, 84',
96", 120" OR 144" SEE NOTE 6, TYP.
15' MAX. FOR
MAINTENANCE STEPS OR
LADDER
L-
12^ RYp)
1" MIN.
2N 2.5" MAX.
"O" RING MIN, REINFORCING STEEL, (TYP.)
12" 12 MAX. GRAVEL BACKFILL FOR PIPE ZONE
12" BEDDING PER WSDOT STD.
SPECIFICATION SECTION 9-03.12(3)
6" 6"
SEPARATE BASE INTEGRAL BASE
PRECAST PRECAST WITH RISER
NOTES:
1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS.
2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE
SLOPED TO FACILITATE CLEANING.
3. THE RECTANGULAR FRAME AND GRATE MUST BE
INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE
CAST INTO THE ADJUSTMENT SECTION.
4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2"
MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP
BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE
PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH
JOINT MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3.
5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET
IN MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3.
6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE
CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE
ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO
AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF
THE SAME MATERIAL AS THE CONNECTING PIPE.
7. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION.
CATCH BASIN DIMENSIONS
CATCH BASIN
DIAMETER
MIN. WALL
THICKNESS
MIN. BASE
THICKNESS
MAXIMUM
KNOCKOUT SIZE
MINIMUM
DISTANCE
BETWEEN
KNOCKOUTS
48"
4"
6"
36"
8"
54"
4.5"
8"
42"
8"
60"
5"
8"
48"
8"
72"
1 6"1
8"1
60"
12"
84"
8"
12"
72"
12"
96"
8"
12"
84"
12"
120"
10"
12"
96"
1 12"
144"
12"
12"
1081,
12"
PIPE ALLOWANCES
CATCH BASIN
PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER
DIAMETER
CONCRETE
ALL METAL
CPSSP'
SOLID WALL
pVC x
PROFILE WALL
PVC,
48"
24"
30"
24"
30"
30"
54"
30"
36"
30"
36"
36"
60"
36"
42"
36"
42"
42"
72"
42"
54"
42"
48"
48"
84"
54"
60"
1 54"
48"
48'•
96"
60"
72"
1 60"
1 48"
48"
120"
66"
84"
1 60"
1 48"
48"
144"
78"
96"
1 60"
1 48"
1 48"
CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20)
z STD. SPEC. 9-05.12(1)
3 STD. SPEC. 9-05.12(2)
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 201.00
• PUBLIC WORKS CATCH BASIN TYPE 2 [PRUMVERD:
DEPARTMENT GAZ 9/28/2018 1
Public Warks AtlminisVat"r DATE
SURVEYED:
TERRANE
DESIGNED:
AE
DRAWN:
CHECKED:
AE
BY DATE APPR APPROVED:
AE
SCALE.
VERTICAL: NAVD 1988
NTSHORIZONTAL NAD 1983/1991
ONE INCH DATUM
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
:45 Al
:45 Al
Know what's below.
Call before you dig.
%R]
CITY OF
RENTON
VASOF
Planning/Building/Public Works Dept.
II..�
rLL
V
Ir-n
V /
0
z
M
R -419708
z
IN COMPLIANCE WITH CITY OF RENTON STANDARDS W
L
O
2
0^'
I�
of
DATE.
STRAIGHT ARROW HOMES N 32ND ST SFR 08/07/2023 =
OFFSITE IMPROVEMENTS FIELDBOOK: B Ur
PAGE: P C/'
DRAWING NO:
R2.03
SHEET
STANDARD DETAILS 8 OF:9
MO
\rn/
V
O
O
N
LIM
M/
O
O
0
N