HomeMy WebLinkAboutR-419805FACE OF CURB
6 12'�-
5 12' 1"
"R r 1"R 7:24
TOP OF
1/2" R. ROADWW
AY
1
1 - �
_ r
_ 1 6
CEMENT CONCRETE
TRAFFIC CURB AND GUTTER
FACE OF ADJACENT CURB
6 12"_, FLUSH WITH GUTTER
PAN AT SIDEWALK
RAMP ENTRANCE
1:12 1:24
TOP OF
12" R. ROADWAY
1
io
1
1 - 6"
DEPRESSED CURB SECTION
AT SIDEWALK RAMPS
PREMOLDED
JOINT FILLER
E FULL -DEPTH
EXPANSION JOINT
6" CEMENT CONCRETE
112" R.
1" R SIDEWALK RAMP
OR LANDING
VARIES
FROM 1
6"TOO
6"
t
318" PREMOLDED
JOINT FILLER
CEMENT CONCRETE
PEDESTRIAN CURB
AT SIDEWALK RAMPS AND LANDINGS
FACE OF ADJACENT CURB
6 1/2"
SEE DEPRESSED CURB DETAIL THIS SHEET
1:24
TOP OF
f - r 1' 12' R. ROADWAY
2-
1
DEPRESSED CURB SECTION
AT RESIDENTIAL DRIVEWAYS ONLY.
FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2
FACE OF ADJACENT CURB
GUTTER SURFACE
FACE OF CURB
6 12-
_512" 1"
12' R. i" R.
1 TOP OF
ROADWAY
'v I:v
1
8 1/4'
CEMENT CONCRETE
TRAFFIC CURB
DEPRESSED CURB DETAIL
AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS
GENERAL NOTES:
1. See standard plans 102 and 101.1 for curb expansion and contraction joint spacing.
2. Expansion joint shall be full depth, 3/8" (in.) premolded joint filler.
3. For Depressed Monolithic Driveway Curb & Gutter Section, see Standard Plan 104.2
STD. PLAN - 101
0 PUBLIC WORKS ,CEMENT CONCRETE CURBS
DEPARTMENT
ABBREVIATIONS:
AC
ACRE
APPROX
APPROXIMATELY
APWA
AMERICAN PUBLIC
WORKS ASSOCIATION
ARCH
ARCHITECTURAL
ASPH
ASPHALT
ASTM
AMERICAN SOCIETY FOR
TESTING AND MATERIALS
AVE
AVENUE
BLDG
BUILDING
BMP
BEST MANAGEMENT PRACTICE
BOM
BOTTOM OF PIPE
BW
BOTTOM OF WALL
C/COMM
COMMUNICATION
CL
CENTERLINE
CB
CATCH BASIN
CF
CUBIC FEET
CI
CAST IRON
CL
CLASS
CMP
CORRUGATED METAL PIPE
CO
CLEAN OUT
COB
CITY OF BELLEVUE
CONC
CONCRETE
CPEP
CORRUGATED POLYETHYLENE
PIPE
CR
CROWN OF PIPE
CSTC
CRUSHED SURFACING TOP
COURSE
CSBC
CRUSHED SURFACING BASE
COURSE
DEPT
DEPARTMENT
DI
DUCTILE IRON
E
EAST
EA
EACH
EC
EXTRUDED CURB
EG
EXISTING GRADE
ELEV
ELEVATION
EP
EDGE OF PAVEMENT
ESC
EROSION & SEDIMENT CONTROL
EXIST
EXISTING
FFE
FINISH FLOOR ELEVATION
FIG
FINISHED GRADE
FH
FIRE HYDRANT
FL
FLANGED
FT
FEET/FOOT
G
GRVL
GV
H
HDPE
HMA
HORIZ
ID
IE
IN
L
LAT
LF
LON
MAX
ME
MH
MIN
MISC
MJ
MON
N
NC
NO.
NTS
OC
OD
OFF
PC
PCC
PI
PL
PP
PRC
PROP
PT
PVC
PVMT
R
RCW
ROW
S
SCH
SD
CONSTRUCTION RECORD
DRAWING:
AS -BUILT INFORMATION FOR
RECORD DRAWINGS PROVIDED
BY TERRANE, JULY 2023.
o_
GAS
GRAVEL
GAS VALVE
HEIGHT
HIGH DENSITY POLYETHYLENE
HOT MIX ASPHALT
HORIZONTAL
INSIDE DIAMETER
INVERT ELEVATION
INCH
LENGTH, OR LEFT
LATITUDE
LINEAR FEET
LONGITUDE
MAXIMUM
MATCH EXISTING
MANHOLE
MINIMUM
MISCELLANEOUS
MECHANICALJOINT
MONUMENT
NORTH
NO CURB
NUMBER
NOT TO SCALE
ON CENTER
OUTSIDE DIAMTER
OFFSET
POINT OF CURVATURE
POINT OF COMPOUND CURVE
POINT OF INTERSECTION
PROPERTY LINE
POWER POLE
POINT OF REVERSE CURVE
PROPOSED
POINT OF TANGENCY
POLYVINYL CHLORIDE
PAVEMENT
RADIUS
REVISED CODE OF WASHINGTON
RIGHT-OF-WAY
SOUTH
SCHEDULE
STORM DRAIN
SDMH
STORM DRAIN MANHOLE
SDR
STANDARD DIMENSION RATIO
SF
SQUARE FEET
SPECS
SPECIFICATIONS
SQYD
SQUARE YARD
SS
SANITARY SEWER
SSCO
SANITARY SEWER CLEANOUT
ST
STREET
STA
STATION
STD
STANDARD
SWPPP
STORM WATER POLLUTION
PREVENTION PLAN
T
TELEPHONE
TIC
TOP OF CURB
TEMP
TEMPORARY
TESC
TEMPORARY EROSION &
SEDIMENT CONTROL
TP
TOP OF PAVEMENT
TOP
TOP OF PIPE
TW
TOP OF WALL
TYP
TYPICAL
UG
UNDERGROUND
UIC
UNDER GROUND INJECTION
CONTROL
UON
UNLESS OTHERWISE NOTED
UP
UTILITY POLE
V VERTICAL
W
WEST
W/
WITH
WAC
WASHINGTON ADMINISTRATIVE
CODE
WSDOT
WASHINGTON STATE
DEPARTMENT
OF TRANSPORTATION
WV
WATER VALVE
YD YARD DRAIN
THIRD DAY DESIGN
CIVIL ENGINEERING
5918 WALLER RD E
TACOMA, WA 98443
(253) 256-1812
C2RAISE0 EDGE DETAILLEVELDEWALK TRANSVERSE12'(IN)RINCLUDE RAISED EDGE
ROU OING
Z SEE RAISED EDGE
1'-P SIDEWALK DETAIL - THIS SHEET'
ALL CUT MIN.
-LOPES]
L/ 17 (IN) R. (TYP.)
FOR CURB DETAILS
SEE STD PLAN 101
oH�t1E¢ 7
SIDEWALK
3.8- (IN) PREI.'OLDCDJOINT FILLER
TYPICAL WHERE APRJCABLE
1 12' (IN) R. (NP.) FOR CURB DETAILS
_ 1.5% ZSEE STO PLAN 101
5 -;ems^�'+-r,- ,EXISTING ROADWAY
r - •,�CRUSHED ROCK BAS
LTYPICAL UNDER CRUSHED SURFACING TOP COURSE (CSTC)
SIDEWALKLK ACT TO 95% MODIFIED PROCTOR
WITH RAISED EDGE (UNLESS REQUIREMENT WANED BY
BASE, WHICHEVER IS GREATER IT-. FOR
ALL CURB 8 GUTTER).
FINISHED GRADE I'(IN) BELOW
TOP OF CONCRETE SURFACE
Z-0•• I SIDEWALK
ADJACENT TO CURB MIN.
1•-0• r-o•
12' (IN) R. (rYP.)
ROU DING FOR CURB DETAILS
2.0% 1 _ 1.5% SEE STD PLAN 101
BRIDGE OR PEDESTRIAN ��N^` , •`�•1'! �-� 2
RAILING
FOR CURB DETAILS ADJACENT TO CURB
BARRIER -SEE
SIDEWALK SEE STD PLAN 101. (STEEP FILL SLOPES)
CONTRACT PLANS rWALL OR BARRIER
I I 12- (IN) R. (TYP.) J--
1 I SIDEWALK
FLUSH 1 •� 1.5%
•-� •' 2-.'r��.`•y'(�� Y ..r 12• N) R.
VERTICAL WALL ^ ,W .._ /, - -. _ -. ,\•1'.,j..'✓' ;w} :. •�(IN)
SEEDETAJLO!a'(1N)PREMOLOEOJOINT FILLERADJACENT TO CURB AND RAILING OR WALL EMO
PREMOLDED
JOINT FILLER
FOR SIDE BUFFER STRIP
TREATMENT SIDEWALK SIDEWALK ADJACENT TO WALL DETAIL
�E (SEE NOTE 10)
SIDEWALK 1, (IN)R.
SECTIONS �1 vl (TYP.) FOR CURB DETAILS
,
1,5%MIN SEE STD PLAN 101
FINISHED GRADE 1- (IN) BELOW TOP OF CONCRETE
SURFACE FOR PLANTING - FLUSH IF PAVED -
ADJACENT TO BUFFER STRIP
GROOMED FINISH
OR MATCH EXISTING
4•'MDE. SMOOTH
TROWELED PERIMETER
CEMENT CONCRETE CURB
(CURB AND GUTTER SHOWN)
FOR CURB DETAILS
SEE STD PLAN 1D7
Z 118'T0114'
NOTES-
1. Four feet of the sidewalk width shall , �-
be the minimum pedestrian
accessible route tstru free vertical
and horizontal obstructions.
Gratings,
Access Covers, Junction Boxes,
Cable Vaults, Pull Boxes and other
appurtenances within the sidewalk
must be flush with surface, and match
grade of the sidewalk. -
2. Monolithic Cement Concrete Curb and
Sidewalk Is not permitted In new For other referenced NOTES see
construction. When replacement work STD PLAN 104.2.
necessitates a Monolithic Cement
Concrete Curb build per WSDOT
Standard Plan F-30.10-03. Paved surfaces must comply with
3. Concrete to be 4,000 P51. STD PLAN 102.1 as applicable.
�i
CONTRAcnONJOINT
IN SIDEWALK ONLY
••,!•r TO •r
R
�• •�
FULL -DEPTH
EXPANSION JOINT IN BOTH
'
CURB AND SIDEWALK
(SEE Sm PUN COL. t)
JOINT AND FINISH
011 - e•
II�'ll
C CONTRACTION JOINT
DETAIL
JOINT FILLER
E FULL -DEPTH
EXPANSION JOINT
-
PUBLIC WORKS CEMENT CONCRETE STD. PLAN
EI'
DEPARTMENT SIDEWALK �Yr r I
GENERAL NOTES:
1. CONTRACTOR SHALL REVIEW EXISTING SITE CONDITIONS AND BRING ANY DISCREPANCIES TO THE ATTENTION OF THE
ENGINEER PRIOR TO CONSTRUCTION.
2. ANY DISCREPANCY IN THESE DRAWINGS, SPECIFICATIONS, AND/OR THE SITE CONDITIONS SHALL BE REPORTED TO THE
ENGINEER, WHO SHALL ADDRESS SUCH DISCREPANCY IN WRITING AFTER REVIEWING ANY CHANGES. ANY WORK
DONE BY THE CONTRACTOR AFTER THE DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S
RISK. VERIFY AND COORDINATE THE DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK.
3. THE LOCATION OF EXISTING UTILITIES SHOWN MAY DIFFER FROM ACTUAL LOCATION. CONTRACTOR SHOULD NOT
ASSUME UTILITIES SHOWN WILL BE THE ONLY UTILITIES/OBSTACLES THAT MAY BE PRESENT ON THE SITE. VERIFY
EXISTING CONDITIONS AND PROCEED WITH CAUTION AROUND ANY ANTICIPATED FEATURES. GIVE NOTICE TO UTILITY
PURVEYORS REGARDING DEMOLITION AND REMOVAL OF SERVICE LINES AND CAP LINES BEFORE PROCEEDING WITH
FURTHER WORK.
4. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DEVELOPING, EXECUTING AND ENFORCING A SAFETY PLAN TO
PROTECT WORKERS AND THE PUBLIC FROM INJURY OR HARM. THE PLAN SHALL CONFORM TO ALL LOCAL, STATE AND
FEDERAL REGULATIONS AND INCLUDE THE FOLLOWING:
4.1. CONTRACTOR SHALL CONSULT WITH THEIR OWN GEOTECHNICAL ENGINEERING EXPERT FOR DETERMINING SOIL
CLASSIFICATION RELATIVE TO SAFE SLOPING OF SOILS.
4.2. CONTRACTOR SHALL DETERMINE SAFE EXCAVATION AND DEWATERING METHODS, MONITOR EXCAVATIONS AND
EARTHWORK OPERATIONS FOR SAFETY CONCERNS AND PROVIDE SHORING AND OTHER PROTECTION AS
REQUIRED TO PROTECT WORKERS.
4.3. IT IS NOT THE INTENT OF THE CONSTRUCTION DOCUMENTS TO DICTATE ANY UNSAFE CONSTRUCTION MEANS OR
METHODS; CONTRACTOR SHALL DETERMINE MEANS AND METHODS OF CONSTRUCTION CONFORMING TO THEIR
SAFETY PLAN AS REQUIRED TO CONSTRUCT WORK SHOWN ON THE CONTRACT DOCUMENTS.
5. PROTECT THE PUBLIC AT ALL TIMES WITH FENCING, BARRICADES, ENCLOSURES, AND/OR OTHER APPROPRIATE BEST
MANAGEMENT PRACTICES; COORDINATE MEASURES WITH OWNER AND CITY OF RENTON.
TEMPORARY EROSION AND SEDIMENT CONTROL NOTES:
1. EROSION AND SEDIMENT CONTROL (ESC) MEASURES SHALL BE IN PLACE PRIOR TO THE BEGINNING OF GROUND
DISTURBING ACTIVITY.
2. ESC MEASURES ARE NOT LIMITED TO THE ITEMS SHOWN ON THESE PLANS. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR THE INSTALLATION AND MAINTENANCE OF ALL ESC MEASURES. SILTATION OF EXISTING OR PROPOSED DRAINAGE
FACILITIES SHALL NOT BE ALLOWED.
3. THE CONTRACTOR SHALL MAKE A DAILY SURVEILLANCE OF ALL ESC MEASURES AS REQUIRED. THE CONTRACTOR
SHALL PROVIDE ADDITIONAL ESC MEASURES AS DETERMINED NECESSARY BY THE PROJECT ENGINEER, OWNER OR
INSPECTOR. FAILURE TO COMPLY WITH ALL LOCAL AND STATE ESC REQUIREMENTS MAY RESULT IN CIVIL PENALTIES
BEING LEVIED AGAINST THE CONTRACTOR.
4. DURING THE WET SEASON (OCTOBER 1ST THROUGH APRIL 30TH), ALL DISTURBED SOILS SHALL BE STABILIZED WITHIN
48 HOURS AFTER STOP OF WORK. DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH), ALL SOILS THAT
WILL BE UNCOVERED OR UNWORKED FOR 7 DAYS SHALL BE COVERED OR STABILIZED. STABILIZATION MEASURES
SHALL INCLUDE BUT ARE NOT LIMITED TO: COVERING THE AFFECTED AREA (INCLUDING SPOIL PILES) WITH PLASTIC
SHEETING, STRAW MATTING, JUTE MATTING, STRAW MULCH OR WOOD CHIPS. SEEDING OF THE DISTURBED AREAS
SHALL TAKE PLACE AS WEATHER PERMITS.
5. TRENCH DEWATERING DEVICES SHALL BE DISCHARGED IN A MANNER THAT WILL NOT ADVERSELY AFFECT STREAMS,
DRAINAGE SYSTEMS, OR OFFSITE PROPERTIES.
6. CATCH BASINS/INLETS RECEIVING RUNOFF FROM THE PROJECT DURING CONSTRUCTION SHALL BE PROTECTED SO
8/14/2023
IL
�p 44221
�FG / S T E?, 1�
SIs,
IUNAL
NO.
REVISION
BY I DATE
NOTES
1. Not used.
2. All ramp and landing edges shall be separately formed.
3. Utilities structures that must remain are to be made non -slip or non-skid.
4. Utilities structures such as vaults and junction boxes shall not be located in the Pedestrian Access Route (PAR) of the
Pedestrian Circulation Route.
5. Drainage appurtenances, such as manholes, catch basins, etc. shall not be located in the PAR. These should be located
in the street or the buffer strip.
6. Accessible pedestrian access shall be provided for during construction.
Y o STD. PLAN - 102.1
PUBLIC WORKS UTILITY PLACEMENT IN PI,R oyI D
DEPARTMENT CEMENT CONCRETE SIDEWALK
( �FNTO
Grelt6 Ammerman, Pub,c WofW Adr., Wfator
THAT SEDIMENT -LADEN WATER WILL BE FILTERED BEFORE ENTERING THE CONVEYANCE SYSTEM.
7. PROVIDE SOIL AMENDMENT PER STD. PLAN 264.00 FOR DISTURBED AREAS (THAT WILL NOT BE IMPERVIOUS IN THE
DEVELOPED CONDITION) AND STABILIZE.
DEMOLITION NOTES:
1. THE DEMOLITION SHOWN ON THE CONSTRUCTION PLAN IS NOT INTENDED TO BE AN EXHAUSTIVE LIST OF ITEMS TO
BE DEMOLISHED. DEMOLITION NOTES ARE FOR CLARIFICATION ONLY AND ARE SHOWN FOR THE CONTRACTOR'S
BENEFIT. DEMOLISH, REMOVE AND LEGALLY DISPOSE OF ALL EXISTING IMPROVEMENTS NECESSARY TO
ACCOMMODATE CONSTRUCTION OF THE PROPOSED IMPROVEMENTS. OBTAIN ALL PERMITS REQUIRED FOR
DEMOLITION AND DISPOSAL.
2. ALL CONSTRUCTION MATERIALS SHALL BE NEW EXCEPT FOR THOSE IDENTIFIED TO BE RELOCATED ON THE PLANS.
RESTORE ANY ITEMS DAMAGED DURING CONSTRUCTION TO THE PRECONSTRUCTION CONDITION.
3. LIMITS OF DISTURBANCE ARE SHOWN PAST THE PROPERTY LINE FOR CLARITY. LAND DISTURBING ACTIVITY SHOULD
NOT EXTEND ONTO ADJACENT PROPERTIES UNLESS OTHERWISE NOTED.
4. THE CONTRACTOR IS RESPONSIBLE FOR THE DEMOLITION, REMOVAL, AND DISPOSAL (IN A LOCATION APPROVED BY
ALL GOVERNING AUTHORITIES) OF ALL STRUCTURES, PADS, WALLS, FLUMES, FOUNDATIONS, PARKING LOTS, DRIVES,
DRAINAGE, STRUCTURES, UTILITIES, ETC., SUCH THAT THE IMPROVEMENTS SHOWN ON THE REMAINING PLANS CAN
BE CONSTRUCTED. ALL FACILITIES TO BE REMOVED SHALL BE UNDERCUT TO SUITABLE MATERIAL AND BROUGHT TO
GRADE WITH SUITABLE COMPACTED FILL MATERIAL PER SPECIFICATIONS ON THE DRAWINGS OR WITHIN THE
GEOTECH REPORT, WHICHEVER IS MORE STRINGENT.
5. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL DEBRIS FROM THE SITE AND DISPOSING THE DEBRIS IN A
LAWFUL MANNER. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS REQUIRED FOR DEMOLITION AND
DISPOSAL.
6. THE CONTRACTOR SHALL COORDINATE WITH RESPECTIVE UTILITY COMPANIES PRIOR TO THE REMOVAL AND/OR
RELOCATION OF UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH THE UTILITY COMPANY CONCERNING
PORTIONS OF WORK WHICH MAY BE PERFORMED BY THE UTILITY COMPANY'S FORCES.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISCONNECTION OF ALL UTILITY SERVICES TO EXISTING BUILDINGS
PRIOR TO DEMOLITION OF THE BUILDINGS. WHERE SHOWN, THE LOCATIONS OF EXISTING UTILITIES SHOWN ON THIS
PLAN HAVE BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND ARE GIVEN FOR THE CONVENIENCE OF
THE CONTRACTOR. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THEIR ACCURACY. PRIOR TO THE START OF ANY
DEMOLITION ACTIVITY, THE CONTRACTOR SHALL NOTIFY THE UTILITY COMPANIES FOR ONSITE LOCATIONS OF
EXISTING UTILITIES.
8. ELECTRICAL, TELEPHONE, CABLE, WATER, FIBER OPTIC CABLE AND/OR GAS LINES NEEDING TO BE REMOVED OR
RELOCATED SHALL BE COORDINATED WITH THE AFFECTED UTILITY COMPANY.
9. STRIP ALL EXISTING VEGETATION AND TOPSOIL WHERE GRADING WORK IS TO OCCUR, UNLESS OTHERWISE NOTED.
GRADING NOTES:
1. ADA COMPLIANCE:
•a. SHALL BE IN ACCORDANCE WITH CFR 28, PART 35;
•b. FOR WORK IN THE RIGHT-OF-WAY, CFR 28, PART 35 SHALL BE SUPPLEMENTED BY THE PUBLIC WORKS RIGHTS OF
WAY ACCESSIBILITY GUIDELINES (PROWAG);
•c. ALL SITE IMPROVEMENTS SUBJECT TO THE AMERICAN WITH DISABILITIES ACT (ADA) STANDARDS FOR ACCESSIBLE
DESIGN SHALL MEET THE FOLLOWING MAXIMUM SLOPES. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR
TO REMOVE AND REPLACE IMPROVEMENTS OUT OF COMPLIANCE WITH THE ADA STANDARDS.
2. THE FOLLOWING MAXIMUM SLOPES SHALL NOT BE EXCEEDED UNLESS NOTED ON THE PLAN AS A "MAXIMUM EXTENT
EXISTING ASPHALT _ 2.0' MIN. NEW CURB
PAVEMENT & GUTTER
(SEE NOTE 2)
SAWCUT
(SEE NOTE 2)
RTERIAL STREET MINIMU
7" HMA (or ACP Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
RESIDENTIAL STREET MINIMUM I
4" HMA (or ACID Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
NOTES:
1. MUST MATCH EXISTING THICKNESS IF GREATER.
2. SAWCUT SHALL BE POSITIONED V 0" BEYOND EDGE OF
DAMAGED PAVEMENT.
3• THE INTENT OF THIS DESIGN IS TO DESCRIBE PAVEMENT
PLACEMENT AT 'THE GUTTER FACE. SEE STANDARD PLAN
FOR CEMENT CONCRETE CURBS.
SM. PLAN - 103
n� + PUBLIC WORKS CURB AND GUTTER \ PPRO D:
�, DEPARTMENT REPLACEMENT DETAIL Z
et'o are
FEASIBLE" (MEF) LOCATION:
a. LONGITUDINAL/RUNNING SLOPE OF WALKWAYS AND CROSSWALKS: 5.00%
b. CROSS SLOPE OF SIDEWALK: 2.00%
c. LONGITUDINAL/RUNNING SLOPE OF RAMP: 8.33%
d. CROSS SLOPE OF RAMP: 2.00%
e. LONGITUDINAL/RUNNING SLOPE OF LANDING: 2.00%
f. CROSS SLOPE OF LANDING: 2.00%
g. TOP OF CURB SLOPE AT RAMP FLARE: 10.00%
h. FLOW LINE SLOPE AT PEDESTRIAN CROSSING: 2.00%
3. REFER TO SOILS REPORT FOR PROJECT FOR INFORMATION ON EXISTING SITE CONDITIONS.
4. THE SPOT ELEVATIONS INDICATED ON THIS PLAN REPRESENT THE DESIGN TOP OF PAVEMENT UNLESS OTHERWISE
NOTED.
5. PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS AND GRADE ALL AREAS
TO PRECLUDE PONDING OF WATER,
6. ADJUST ALL EXISTING MANHOLE RIMS, DRAINAGE STRUCTURES, VALVE BOXES, VAULT LIDS AND UTILITY ACCESS
STRUCTURES THAT WILL BE PRESERVED TO FINISHED GRADE WITHIN AREAS AFFECTED BY CONSTRUCTION.
7. THE EXISTING SITE SOILS REQUIRE PROPER COMPACTION PRIOR TO PLACEMENT OF BUILDING, PAVING, AND UTILITY
IMPROVEMENTS.
8. PROVIDE SOIL AMENDMENT PER STD. PLAN 264.00 FOR DISTURBED AREAS (THAT WILL NOT BE IMPERVIOUS IN THE
DEVELOPED CONDITION) AND STABILIZE.
STORM DRAINAGE NOTES:
1. STATION AND OFFSET CALLOUTS FOR STORM (IF PROVIDED) ARE TO CENTER OF STRUCTURE.
2. PIPE LENGTHS NOTED ON THE PLANS ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE.
3. REMOVE ALL SILT AND DEBRIS FROM EXISTING DRAINAGE PIPES AFTER CONTRIBUTING BASIN AREAS HAVE BEEN
PERMANENTLY STABILIZED.
Know what's below.
Call before you dig.
SURVEYED:
TERRAN E
SCALE.
NTVC
VERTICAL: NAVD 1988
HORIZONTAL: NAD 198311991
DATUM
CITY OF
%R]
RENTON
ENTON
Planning/Building/Public Works Dept.
DESIGNED:
AE
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
CHECKED:
AE
APPR
APPROVED:
AE
R-419805
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
STRAIGHT ARROW HOMES 910 N 31 ST ST SFR 8/14/2023
OFFSITE IMPROVEMENTS FIELDBOOK: B
PAGE: P
DRAWING NO:
R2.01
CIVIL NOTES, ABBREVIATIONS AND STANDARD DETAILS SHEET 5 OF:
LL
U)
r
co
Z
0
r
CO
UJ
2
0
O
Of
Q
2
cn
co
V
O
O
N