Loading...
HomeMy WebLinkAboutR-419807Vim, DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 1 1 0 W l- I` CONSTRUCTION RECORD DRAWING: AS -BUILT INFORMATION FOR RECORD DRAWINGS PROVIDED BY TERRANE, JULY 2023. THIRD DAY DESIGN CIVIL ENGINEERING 5918 WALLER RD E TACOMA, WA 98443 (253) 256-1812 13"x24" PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC, INC. BCF SERIES MSBCF 1324-18 WITH 1.75" THICK DUCTILE IRON DIAMOND PLATE COVER EQUAL TO MID -STATES PLASTICS, NC. MSCBC-1324-R WITH READER LID AND 2" DRILLED HOLE FOR TOUCHREAD PIT LID (SEE DETAIL A -A) 36" MIN COVER NEW DUCTILE IRON WATERMAIN CITY PIPING z f-IN UNIMPROVED RIGHT OF z PRIVATE PIPING FINISH GRADE 9° MIN 12" MAX I-- w 01 PROPERTY LINE WITH 12" LONG COPPER TAILPIECE. SIDEWALK 1}- w a ? ¢ TOUCHREAD WATER :2x j METER TO BE _- O SUPPLIED BY THE 12 z_ x \ _ CITY TYPE COPPER TUBING SOFT :2 > '0/ 22-1 /2° IF SERVICE LINE TO HOUSE IS 3/4" OR 1" TO BE INSTALLED IN THE FUTURE GALVANIZED INSTALL FORD C14-33 OR 44 FIPT PLUG x COMPRESSION COUPLING I -LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN COPPER ZL COPPERSETTER FOR 5/8"x3/4" METER: FORD SERVICE LINE TO METER. VBH72-15W-44-33G, OR McDONALD BRASS: 21-215WCQQ33, OR MUELLER: 3/4-B-2470-2 WITH ANGLE BALL VALVE ON INLET AND SINGLE CHECK VALVE ON OUTLET CORPORATION STOP WITH BALL VALVE. FORD COPPERSETTER FOR 1" METER: FORD VBH72-15W-44-44G, OR TAPERED THREAD (CC). QUICK JOINT McDONALD BRASS: 21-415WCQQ44, OR MUELLER: 1-B-2470-2 (3/4" FB1000-3-Q) OR AY MCDONALD 4701B BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON (1" FB1000-4-Q) OR AY MCDONALD 4701E INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET. ALL FITTINGS SHALL BE WITH QUICK JOINT. N OTE: ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUSH BE INSTALLED ON BOTH SIDES OF METER BOX. A- A DRILL 2" DIA. HOLE FOR AMR (AUTOMATIC METER READ) TOUCHREAD DEVICE L 2-1/2" MIN. FROM NEAREST AND FRONT EDGE OF PIT LID TYPICAL RIB NOTE: THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE RIB. `C Y i.►j� PUBLIC WORKS 3/4" AND 1" WATER SERVICE STD. PLAN - 320.1 DEPARTMENT NOVEMBER 2009 DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 r,� r--I-r----------, ---------- :,EX. SEWER MAIN I I I I ' I I I I PROPERTY LINE SPOOL I I I Z (LENGTH AS NEEDED) I 1 1 I 3'-0" MIN 6" SEWER STUB I i i M t" FUTURE 4" SIDE SEWER ( DC----------� I I 1 I I I 2"x 4" STUD MARKING POST PAINTED !\ 6" CAP WHITE WITH THE WORD "SEWER' STENCILED `SEWER MAIN TEE X 6" TEE 1 j i I IN 3" HIGH BLACK LETTERS AND #6 WIRE SIDEWALK i = WRAPPED AROUND THE STUD AND I I I I I EXTENDED TO THE TOP OF THE STUD � COUPLING (TYP) C» I3 I 6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER O (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID), CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD CONCRETE PAD TO BE 8" IN DEPTH -------------------------- r - L---J T BEND AS REQUIRED EXISTING SANITARY SEWER MAIN _2 0% MIN SLOPE \\� \\ !\\ ` FUTURE 4" SIDE SEWER \\-6" SEWER STUB 6"X6"X6" WYE FUTURE 6"x 4" REDUCER SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL) C PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) 0. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC). CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F HOPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL NOTE. I PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHALL HAVE A MINIMUM 2 X SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102 6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405 7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON SIDE SEWER STUB p(1����y��ppSTD. PLAN -406.1 APPROVED'-n•dby, • PUBLIC WORKS INSTALLATION DEPARTMENT Martin Pastucfi@1/26/202 (SEWER MAIN TO PROPERTY LINE) 8B8S8]FD988449D o"m. w",r,.nmw.nnw DATE WA P 8/14/2023 � h � 44221 �EOISTER�� vow S&JONAL 1 12: ', 4", 6", 12", OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION E� 16 S `AyP l A #3 BAR EACH CORNER �T #3 BAR EACH SIDE sFF�z, �OrF� #3 BAR EACH WAY J PRECAST BASE SECTION #3 BAR HOOP #3 BAR EACH CORNER 18" MIN. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION o PUBLIC WORKS `DII DEPARTMENT VAMIV PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 12" CONCRETE ALL METAL PIPE 15" CPSSP', 12" STD. SPEC. 9-05.20 SOLID WALL PVC, STD. SPEC. 9-05.12(1) 15" PROFILE WALL PVC, STD. SPEC. 9-05.12(2) 15 ' CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H:24V OR STEEPER. & THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 200.00 APPR ED: CATCH BASIN TYPE 1 GAZ 9/28/2018 1 _ -1., W" Ad---, DATE DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 za" ' c1 BOLT -DOWN SLOT SEE DETAIL AND 2 1/2" DIA. HOLE NOTE 1 zo•' O� �O�ODO O�O�O�O O�O�0�0�0 TOP ISOMETRIC r4 3/4" 1 112" T 1 5/8" MAX.t lti 139", SEE NOTE 2 SECTION A PUBLIC WORKS II PDEPARTMENT 1/2" 3I4" 1 it/4" A TI BOLT -DOWN SLOT DETAIL SEE NOTE 1 R26". SEE NOTE 2 '2" SECTION B NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN LIEU OF THE RIB DESIGN. 3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 204.10 D: RECTANGULAR SOLID METAL COVER GAZ 9/28/2018 v"nnwo,u: Aam�m,vaw, DATE :45 AI :45 AN Know what's below. Call before you dig. R-419807 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURVEYED: TERRINE SCALE: N T C V VERTICALNAVD,986 HORIZONTAL NAD 1983/1991 DATUM � Y OF 10) RENTON • Planning/Building/Public Works Dept. STRAIGHT ARROW HOMES 910 N 31 ST ST SFR OFFSITE IMPROVEMENTS STANDARD DETAILS ur.' �. 8/14/2023 DESIGNED: AE FIELD PAGE: : B PAGEBOOK P DRAWN: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY DRAWING NO: R2.03 CHECKED: AE NO. REVISION BY DATE APPR APPROVED: AE SHEET: OF: 7 7 �rn VM/ 0 0 0 T_ N