CONSTRUCTION RECORD
DRAWING:
AS -BUILT INFORMATION FOR
RECORD DRAWINGS PROVIDED
BY TERRANE, JULY 2023.
THIRD DAY DESIGN
CIVIL ENGINEERING
5918 WALLER RD E
TACOMA, WA 98443
(253) 256-1812
13"x24" PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC,
INC. BCF SERIES MSBCF 1324-18 WITH 1.75" THICK DUCTILE
IRON DIAMOND PLATE COVER EQUAL TO MID -STATES PLASTICS,
NC. MSCBC-1324-R WITH READER LID AND 2" DRILLED HOLE
FOR TOUCHREAD PIT LID (SEE DETAIL A -A)
36" MIN COVER
NEW DUCTILE
IRON
WATERMAIN
CITY
PIPING
z f-IN UNIMPROVED RIGHT OF z
PRIVATE
PIPING
FINISH GRADE
9° MIN
12" MAX
I--
w
01
PROPERTY LINE WITH 12"
LONG COPPER TAILPIECE.
SIDEWALK
1}-
w
a
? ¢
TOUCHREAD WATER
:2x
j
METER TO BE
_- O
SUPPLIED BY THE
12 z_ x
\ _
CITY
TYPE
COPPER TUBING
SOFT
:2 >
'0/
22-1 /2°
IF SERVICE LINE TO HOUSE IS
3/4" OR 1"
TO BE INSTALLED IN THE FUTURE
GALVANIZED
INSTALL FORD C14-33 OR 44 FIPT
PLUG
x COMPRESSION COUPLING
I -LOOP DOWN TO CENTERLINE
OF WATER MAIN TO
PROVIDE SLACK IN COPPER ZL COPPERSETTER FOR 5/8"x3/4" METER: FORD
SERVICE LINE TO METER. VBH72-15W-44-33G, OR McDONALD BRASS: 21-215WCQQ33, OR
MUELLER: 3/4-B-2470-2 WITH ANGLE BALL VALVE ON INLET AND
SINGLE CHECK VALVE ON OUTLET
CORPORATION STOP WITH BALL VALVE. FORD COPPERSETTER FOR 1" METER: FORD VBH72-15W-44-44G, OR
TAPERED THREAD (CC). QUICK JOINT McDONALD BRASS: 21-415WCQQ44, OR MUELLER: 1-B-2470-2
(3/4" FB1000-3-Q) OR AY MCDONALD 4701B BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON
(1" FB1000-4-Q) OR AY MCDONALD 4701E INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET.
ALL FITTINGS SHALL BE WITH QUICK JOINT.
N OTE:
ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE
CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUSH BE INSTALLED ON
BOTH SIDES OF METER BOX.
A- A DRILL 2" DIA. HOLE FOR AMR (AUTOMATIC
METER READ) TOUCHREAD DEVICE
L 2-1/2" MIN. FROM NEAREST
AND FRONT EDGE OF PIT LID
TYPICAL
RIB
NOTE:
THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM
UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE
NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN
ONE RIB.
`C Y
i.►j� PUBLIC WORKS
3/4" AND 1" WATER SERVICE STD. PLAN - 320.1
DEPARTMENT
NOVEMBER 2009
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
r,� r--I-r----------,
----------
:,EX. SEWER MAIN I I I I '
I I I I
PROPERTY LINE
SPOOL I I I Z
(LENGTH AS NEEDED) I 1 1 I 3'-0" MIN
6" SEWER STUB I i i M t" FUTURE 4" SIDE SEWER
( DC----------�
I I 1
I I I 2"x 4" STUD MARKING POST PAINTED
!\ 6" CAP WHITE WITH THE WORD "SEWER' STENCILED
`SEWER MAIN TEE X 6" TEE 1 j i I IN 3" HIGH BLACK LETTERS AND #6 WIRE
SIDEWALK i = WRAPPED AROUND THE STUD AND
I I I I I EXTENDED TO THE TOP OF THE STUD
� COUPLING (TYP)
C» I3
I 6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER
O (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR
APPROVED EQUAL, SPECIFY "SEWER" ON LID),
CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD
CONCRETE PAD TO BE 8" IN DEPTH
--------------------------
r -
L---J T
BEND AS
REQUIRED
EXISTING SANITARY
SEWER MAIN _2 0% MIN SLOPE \\�
\\ !\\ ` FUTURE 4" SIDE SEWER
\\-6" SEWER STUB 6"X6"X6" WYE FUTURE 6"x 4" REDUCER
SEWER MAIN SIZE X 6" TEE
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN
A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL)
C PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE
(OR APPROVED EQUAL)
0. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL)
E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC). CUT IN A NEW PVC "TEE" USING
"STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
F HOPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER
G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE
SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL
NOTE.
I PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT
2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER
3 SIDE SEWERS SHALL HAVE A MINIMUM 2 X SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR
4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE
SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT
THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102
6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405
7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON
SIDE SEWER STUB p(1����y��ppSTD. PLAN -406.1
APPROVED'-n•dby,
• PUBLIC WORKS INSTALLATION
DEPARTMENT Martin Pastucfi@1/26/202
(SEWER MAIN TO PROPERTY LINE) 8B8S8]FD988449D
o"m. w",r,.nmw.nnw DATE
WA P 8/14/2023
� h �
44221
�EOISTER�� vow
S&JONAL
1 12:
', 4", 6", 12", OR 24"
ONE #3 BAR HOOP FOR 6" HEIGHT
INCREMENT (SPACED EQUALLY),
SEE NOTE 1
RECTANGULAR ADJUSTMENT SECTION
E�
16 S
`AyP l A
#3 BAR EACH CORNER
�T
#3 BAR EACH SIDE
sFF�z,
�OrF�
#3 BAR EACH WAY J
PRECAST BASE SECTION
#3 BAR HOOP
#3 BAR EACH
CORNER 18" MIN.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
o PUBLIC WORKS
`DII DEPARTMENT
VAMIV
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR PLAIN
12"
CONCRETE
ALL METAL PIPE
15"
CPSSP',
12"
STD. SPEC. 9-05.20
SOLID WALL PVC,
STD. SPEC. 9-05.12(1)
15"
PROFILE WALL PVC,
STD. SPEC. 9-05.12(2)
15
' CORRUGATED POLYETHYLENE STORM
SEWER PIPE
NOTES:
1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN
IN THE PRECAST BASE SECTION, FIBERS (PLACED IN
ACCORDANCE WITH STANDARD SPECIFICATION
9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF
0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH
THE MINIMUM REQUIRED REBAR SHOWN IN THE
ALTERNATIVE PRECAST BASE SECTION. WIRE MESH
SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN
ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN
THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH
HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER
FOOT MAY BE USED.
2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER
THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS
OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5"
MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE
OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED,
FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-04.3.
3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO
THE LOWEST PIPE INVERT SHALL BE 5 FEET.
4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE
FLANGE DOWN.
5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED
FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF
1 H:24V OR STEEPER.
& THE OPENING SHALL BE MEASURED AT THE TOP OF THE
PRECAST BASE SECTION.
7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE
INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR
NON -SHRINK APPLICATIONS IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-20.3(2).
8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN
MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE
AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND
FRAMES.
9. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION.
UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS)
STD. PLAN - 200.00
APPR ED:
CATCH BASIN TYPE 1 GAZ 9/28/2018 1 _
-1., W" Ad---, DATE
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
za" '
c1
BOLT -DOWN SLOT
SEE DETAIL AND
2 1/2" DIA. HOLE NOTE 1
zo•'
O�
�O�ODO
O�O�O�O
O�O�0�0�0
TOP
ISOMETRIC
r4 3/4" 1 112" T
1 5/8" MAX.t
lti
139", SEE NOTE 2
SECTION A
PUBLIC WORKS
II PDEPARTMENT
1/2"
3I4"
1 it/4"
A
TI
BOLT -DOWN SLOT DETAIL
SEE NOTE 1
R26". SEE NOTE 2
'2"
SECTION B
NOTES:
1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES,
GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED.
PROVIDE TWO HOLES IN THE FRAME THAT ARE
VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS.
THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN
HEAD CAP SCREW BY BEING TAPPED, OR OTHER
APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES
VARIES BY MANUFACTURER.
2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN
LIEU OF THE RIB DESIGN.
3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR
ADDITIONAL REQUIREMENTS.
4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD
PLAN 204.00.
UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS)
STD. PLAN - 204.10
D:
RECTANGULAR SOLID METAL COVER GAZ 9/28/2018
v"nnwo,u: Aam�m,vaw, DATE
:45 AI
:45 AN
Know what's below.
Call before you dig.
R-419807
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURVEYED:
TERRINE
SCALE:
N T C V
VERTICALNAVD,986
HORIZONTAL NAD 1983/1991
DATUM
� Y OF
10)
RENTON
•
Planning/Building/Public Works Dept.
STRAIGHT ARROW HOMES 910 N 31 ST ST SFR
OFFSITE IMPROVEMENTS
STANDARD DETAILS
ur.' �.
8/14/2023
DESIGNED:
AE
FIELD
PAGE: : B
PAGEBOOK
P
DRAWN:
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
DRAWING NO:
R2.03
CHECKED:
AE
NO.
REVISION
BY
DATE
APPR
APPROVED:
AE
SHEET: OF:
7 7